Manuel d’utilisation Vermont Casting UE241N

14 pages 0.17 mb
Télécharger

Aller à la page of 14

Summary
  • Vermont Casting UE241N - page 1

    Decorative Gas Appliance For Installation In Solid Fuel Burning Fireplaces 331 1243 7/04 Rev . 1 Certified to ANSI Z21.1 1.2A Standard D E S I G N C E R T I F I E D W ARNING If the information in this manual is not followed exactly , a fire or explosion may result causing property damage, personal injury or loss of life. Installation and Operating ...

  • Vermont Casting UE241N - page 2

    2 331 1243 A TTENTION This unvented gas log heater has been certified by CSA and tested to conform to ANSI Z21.1 1.2 Gas Fired Room Heaters. Check local codes before installing this log heater . In some areas of the country , unvented gas log heaters are restricted. The installation and provision for combustion and ventilation air must conform with ...

  • Vermont Casting UE241N - page 3

    3 331 1243 CARBON MONOXIDE POISONING MA Y LEAD TO DEA TH When used without fresh air , vent free gas logs may give off carbon monoxide, an odorless, poisonous gas. Some people such as pregnant women, people with heart or lung disease and persons at high altitudes are more affected by carbon monoxide than others. Early signs of carbon monoxide poiso ...

  • Vermont Casting UE241N - page 4

    4 331 1243 Provisions for Adequate Combustion and V entilation Air This heater shall not be installed in a “ CONFINED SP ACE” or unusually tight construction unless provi- sions are provided for adequate combustion and ventilation air . The NA TIONAL FUEL GAS CODE, ANSI Z223.1/NFP A 54 defines a “CONFINED SP ACE” as a space whose volume is ...

  • Vermont Casting UE241N - page 5

    5 331 1243 Fireplace Spacing Requirements The illustration in Figure 2 shows spacing requirements for your room with a hood installed (not included). W ithout a hood, you must maintain a minimum of 32” between the top opening of the firebox and the bottom of a mantel which protrudes out 12”. If you do not have at least 32” between the two, a ...

  • Vermont Casting UE241N - page 6

    6 331 1243 A TTENTION: This heater is clean burning. It requires no outside venting. There is no heat loss out a vent or up a chimney . Heat is generated by realistic flames. This heater is designed for vent-free operation with flue damper closed. State and local codes in some areas prohibit the use of vent-free heaters. NOTE: Where listed vented d ...

  • Vermont Casting UE241N - page 7

    7 331 1243 • If the fireplace has glass doors, remove the glass doors and frame assembly or the upper door track. • If the upper door track has been removed, follow the instructions for Figure 3. If the upper door track remains, skip Figure 3 and follow the instructions for Figure 4. 2. If the upper door track has been removed, hold the adjusta ...

  • Vermont Casting UE241N - page 8

    8 331 1243 Connection to Gas Supply 1. Place the burner assembly (grate and control package) in the fireplace. Center the assembly front to back and side to side. 2. Install the gas supply fitting to the gas supply pipe. Use pipe thread sealing compound, or T eflon tape, on the iron pipe threads only . Do not use on flared threads. 3. Connect the b ...

  • Vermont Casting UE241N - page 9

    9 331 1243 Guidelines After your installer does the test burn, the log set should be operated either with the chimney open or , in the absence of a chimney , with a window open approxi- mately 1-2 inches. This operation should last for about 2-3 hours to cure the logs and dissipate any residual fumes from the new unit. This unvented gas log heater ...

  • Vermont Casting UE241N - page 10

    10 331 1243 Thermostatic Control The thermostat control knob can be set to any comfort level between “HI” and “LO”. The thermostat will gradually modulate the heat output and flame height from higher to lower settings in order to maintain the comfort level you select. The ideal comfort setting will vary by household depending upon the amoun ...

  • Vermont Casting UE241N - page 11

    11 331 1243 Oxygen Depletion System For your safety , this appliance is equipped with an oxygen depletion system. This system senses the oxygen in the firebox and switches off the gas supply before the amount of oxygen falls below safe levels. (Fig. 12) Pilot ODS Sensor Flame Thermocouple Piezo Ignitor FP1505 Fig. 12 Pilot. Maintenance To clean the ...

  • Vermont Casting UE241N - page 12

    12 331 1243 UC/UE181, UC/UE241 Series Unvented Gas Log Heaters Ref. Description UC/UE181 UC/UE241 1a. Log Assembly - 2 Larger Bottom Logs 4312759 4312760 1b. Log Åssembly - 3 Smaller T op Logs 4312761 4312762 2. Bag of Lava Rock (2 lbs.) (2 per Heater) 20000198 20000198 3. Flexline Gas Connector 3304177 3304177 4. Damper Clamp Assembly 7540310 754 ...

  • Vermont Casting UE241N - page 13

    13 331 1243 Failure to follow all instructions in this owner ’s manual will also void this warranty . CFM Home Products will not be liable for incidental or consequential damages. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above exclusion or limitation may not apply to you. This warranty gi ...

  • Vermont Casting UE241N - page 14

    2695 Meadowvale Blvd. • Mississauga, Ontario, Canada L5N 8A3 800-668-5323 CFM Home Products ...

Fabricant Vermont Casting Catégorie Fan

Les documents que nous recevons du fabricant de l'appareilVermont Casting UE241N peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Vermont Casting
- manuels d’utilisations UE241N
- fiches produit Vermont Casting
- dépliants
- ou étiquettes-énergie Vermont Casting UE241N
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Vermont Casting UE241N.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Vermont Casting UE241N, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Vermont Casting UE241N. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Vermont Casting UE241N.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Vermont Casting UE241N, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Vermont Casting UE241N par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Vermont Casting UE241N.

Le manuel d’utilisation complet Vermont Casting, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Vermont Casting UE241N - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Vermont Casting UE241N, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lVermont Casting UE241N qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Vermont Casting UE241N - qui devraient nous aider dans les premières étapes lors de l'utilisation Vermont Casting UE241N
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Vermont Casting UE241N
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Vermont Casting UE241N dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Vermont Casting UE241N?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Vermont Casting UE241N, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Vermont Casting UE241N il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)