Fisher & Paykel DEGX1US - page 1
Installation instruc tions DEGX1US Electric Dr yer ...
-
Fisher & Paykel DEGX1US - page 2
I mpor tant safety instruc tions W ARNING T o reduce the risk of fire, elec tric shock, or injur y to persons when using your appliance, follow basic precautions, including the following: 1. Read all instructions befor e using the appliance. 2. I nstallation and ser vice must be per formed by a qualified installer or ser vice agenc y . 3. Mak e sur ...
-
Fisher & Paykel DEGX1US - page 3
Read this befor e you star t installing your dr yer This is the safety aler t symbol. This symbol alerts you to hazards that can kill or hurt you and others. The safety aler t symbol and the word DANGER or W ARNING will precede all safety messages. These words mean: Y ou can be k illed or seriously injured if you don’ t immediately follow instruc ...
-
Fisher & Paykel DEGX1US - page 4
T o the installer The correct installation of the dr yer is your responsibility. Be sure you read the following instructions carefully before you start to install the dr yer . These instructions should be left with the home owner for future ref erence. It is your responsibility to: Obser ve all governing codes and ordinances. Check code req ...
-
Fisher & Paykel DEGX1US - page 5
The area in which the dr yer is located must be kept clear and free from combustible materials, gasoline and other flammable vapours and liquids. A dr yer produces combustible lint so the area around the dr yer must be cleaned regularly to keep it free of lint. This dr yer can only be vented from the rear and must be exhausted to the outdoors. Alco ...
-
Fisher & Paykel DEGX1US - page 6
Dimensions Lid clearance Check that there is enough clearance for the lid to fully open. ...
-
Fisher & Paykel DEGX1US - page 7
Mobile home installation The installation of the dr yer in a mobile home must conform to the Manufac tured Home Construction and Safety Standard Title 24 CFR, Part 32-80 {formerly the F ederal Standard for Mobile Home Construction and Safety , Title 24 HUD (Part 280), 1975} for the United States. When installing a dryer in a mobile home, provisions ...
-
Fisher & Paykel DEGX1US - page 8
Exhausting The dr yer must be exhausted to the outdoors. This will prevent the build up of lint and moisture in the room in which it is located and reduce the risk of fire. W ARNING Fir e Hazard The dr yer must be vented to the outdoors. Use rigid or thick wall flexible metal exhaust duc t. Do not use a plastic exhaust duc t. Do not use a metal foi ...
-
Fisher & Paykel DEGX1US - page 9
T o reduce condensation, insulate any ducting which passes through unheated areas. Slope the duct gently downwar ds to the hood, to drain condensation and reduce lint build up. Avoid sag or loops in the duct as the y may collect and store water and accumulate lint. Before using an existing exhaust duct system for a dr yer ensure that: No plasti ...
-
Fisher & Paykel DEGX1US - page 10
Choose a route that will provide the straightest and most direct path outdoors. Plan the installation to use the fewest number of elbows and turns. When using elbows (r igid duct) or making turns (thick wall flexible metal duct), allow as much room as possible. W ith thick wall flexible metal duct bend duc t gradually to avoid k ink ing and avoid 9 ...
-
Fisher & Paykel DEGX1US - page 11
Preferre d 4” Ho ods When you have a 4” (10cm) Hood Maximum length of 4” diameter metal duc t. Number of 90˚ elbows/bends Rigid Thick W all Flexible Metal (fully ex tended) 0 64ft 19.5m 36ft 10.9m 1 54ft 16.5m 31ft 9.4m 2 44ft 13.4m 27ft 8.2m 3 35ft 10.6m 25ft 7.6m 4 27ft 8.2m 23ft 7.0m Acceptable 2 ”Hood When you have a 2 ” (6cm) ...
-
Fisher & Paykel DEGX1US - page 12
Alternative installation f or close clearances Venting systems come in many varieties. Selec t the type best for your installation. A close - clearance installation is shown. swivel collar sections separate, fittings can face same or opposite beveled edges allow corne r installations swivel collar wall connection telescoping sections Extra long ban ...
-
Fisher & Paykel DEGX1US - page 13
Exhaust venting W ARNING Fir e Hazard Use heavy metal exhaust duct. Do not use a plastic exhaust duc t. Do not use thin metal foil exhaust duc t. F ailure to do so can result in death or fire. 1. Read the exhaust sec tion (page 8–12) before installing the exhaust system to determine the maximum allowable exhaust duc t length. Do not use sheet met ...
-
Fisher & Paykel DEGX1US - page 14
I nstallation P ar ts and literature are pack aged inside the dr yer drum. W ARNING Ex cess W eight Hazard Use two or more people to move and install the dr yer . F ailure to do so can result in back or other injury . Only remove the pack aging at the customer ’ s premises. This will ensure the appliance ar rives in pristine condition and reduces ...
-
Fisher & Paykel DEGX1US - page 15
F itting the front feet Note: Dr yer is usually supplied with feet fitted and protruding the correct distance. 1. T ilt the dr yer back using a hand trolley and mak ing sure the trolley and dr yer are secure. 2. Fit a rubber inser t to each plastic foot as shown. 3. Screw the feet into the foot retainers on the left hand and right hand sides as sho ...
-
Fisher & Paykel DEGX1US - page 16
Electr ical requir ements W ARNING Electric Shock Hazard Use a new UL approv ed 30-ampere power cord or direct wire cable. Use a UL approved strain relief. Disconnect pow er before mak ing elec trical connec tions. Connect neutral wire (white or center wire) to center terminal. On all four wire installations remove the grounding link and connect th ...
-
Fisher & Paykel DEGX1US - page 17
W ARNING Electric al Shock Hazard Make sure appliance is wired or plugged into a grounded outlet. Do not use an adaptor . Do not use an extension cord . F ailure to follow these instructions can result in death, fire, or elec trical shock . Grounding instruc tions W ARNING Electric al Shock Hazard Check with a qualified elec trician or serviceperso ...
-
Fisher & Paykel DEGX1US - page 18
P ower supply cord requirements for U .S.A Only a UL listed power-supply cord k it at least 6ft (1.8m) long and rated 120/240 V min, 30 A and marked with use for clothes dr yers shall be used. This shall have ring terminals to connect to the dr yer . The UL -rated strain relief included with it shall be suitable for a 1 1 / 8 ” (28.5m ...
-
Fisher & Paykel DEGX1US - page 19
Electr ical connections Please read Electrical requiremen ts and grounding instruc tions on pages 16–18 first. The DEGX1 electric model of the Smar tLoad™ dr yer is manufactured for a 3-wire connection system. T he dr yer frame is grounded by a link to the neutral conduc tor on the dr yer terminal block. If local codes do not per mit grounding ...
-
Fisher & Paykel DEGX1US - page 20
3-wir e connections F or use where local codes permit grounding through the Neutral wire . Use appro ved 3-wir e P ower Supply Cord or a 3-w ire Cable fo r Direct W iring as described on page 18. 1. Remove the terminal block cover plate. 2. I nsert the power cord with a UL listed strain relief through the hole provided in the cabinet near the termi ...
-
Fisher & Paykel DEGX1US - page 21
3-wir e connec tions plus separate grounding connector F or use where local codes do not permit grounding through the Neutral wire. Use appro ved 3-wir e P ower Supply Cord or a 3-w ire Cable fo r Direct W iring as described on page 18. A separate 10A WG copper grounding wire is required . 1. Remove the terminal block cover plate. 2. I nsert the po ...
-
Fisher & Paykel DEGX1US - page 22
4-wir e connections Use approved 4-wire Power Supply Cord or a 4-wire Cable for Direct Wiring as described on page 18. 1. Remove the terminal block cover plate. 2. I nsert the power supply cable with a UL listed strain relief through the hole provided in the cabinet near the terminal block. Do not tighten strain relief screw until wiring connection ...
-
Fisher & Paykel DEGX1US - page 23
L evel machine Check the dr yer is level, and make necessar y adjustments to the front levelling feet. The rear levelling feet are self adjusting. F inal installation check list Check that: No plastic or flexible metal foil is used in the exhaust ducting. Exhaust is rigid ducting or thick wall flexible metal ducting. All joints in the d ...
-
Fisher & Paykel DEGX1US - page 24
Copyright Reser ved © F isher & Pa ykel 2004. The product specifications in this book let apply to the specific products and models described at the date of issue. Under our polic y of continuous product improvement, these specifications may change at any time. Y ou should therefor e check with your Customer Care Center to ensure this booklet ...
Avez-vous une question à propos de Fisher & Paykel DEGX1US?
Utiliser le formulaire ci-dessous
Si vous n’avez pas résolu votre problème avec Fisher & Paykel DEGX1US, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Fisher & Paykel DEGX1US il est probable qu’il a envie de partager la façon de le résoudre.