    PRODUCT DAT A Put Bar Code Here 68-0282-07 Y8150 Fresh Air V entilation System, W8150 Fresh Air V entilation Control APPLICATION The Y8150 Fresh Air V entilation System, W8150 Fresh Air V entilation Control provide fres h air to a home. The control operates a fresh air intake damper and, when necessary , activates the main HV AC blower to efficient ...

  • Honeywell Y8150 - page 2

    Y8150 FRESH AIR V ENTILATION SYSTEM, W8 150 FRESH AIR V ENT ILATION CONTROL 68-0282—0 7 2 SPECIFICATIONS Y8150 includes: W8150A Fresh Air V entil ation Control. EARD6 Fresh Air Damper . A T120B T ransformer . Mounting hardware for control. Homeowner information label. W8150 includes: W8150 Fresh Air V entil ation Control. Mounting hardware for co ...

  • Honeywell Y8150 - page 3

    Y8150 FRESH AIR V ENTILATION SYSTEM, W8 150 FRESH AIR VENTILATION CONTROL 3 68-0282—07 W8150 QUICK GUIDE No. Name Description Function 1G F Equipment fan Allows W8150 to pass thermost at calls and, when necessary , turn on system fan for ventilation. This should be the only connecti on to G on the HV AC equipment. 2R C 24 V ac cooling system powe ...

  • Honeywell Y8150 - page 4

    Y8150 FRESH AIR V ENTILATION SYSTEM, W8 150 FRESH AIR V ENT ILATION CONTROL 68-0282—0 7 4 INST ALLATION A fresh air duct and damper must be installed between the outdoors and the return side of the HV AC equipment. The W8150 control will be mounted near th e HV AC system and wired between the thermost at and the fan control. Y ou will need… • ...

  • Honeywell Y8150 - page 5

    Y8150 FRESH AIR V ENTILATION SYSTEM, W8 150 FRESH AIR VENTILATION CONTROL 5 68-0282—07 Inst alling fresh ai r damper , ducting, and control… 1. Disconnect power from HV AC system. 2. Install the weather hood, du cting, and damper followi ng local practices. Be sure al l duct and insulation seams are tightly sealed. 3. Mount the transformer and ...

  • Honeywell Y8150 - page 6

    Y8150 FRESH AIR V ENTILATION SYSTEM, W8 150 FRESH AIR V ENT ILATION CONTROL 68-0282—0 7 6 Measuring airflow… 1. Make sure all HV AC system air filters are clean and installed. 2. Push T est button: • Control opens damper and turns on HV AC fan for three minutes. • A red or green light is flashing; you can now me asure airflow . 3. Follow in ...

  • Honeywell Y8150 - page 7

    Y8150 FRESH AIR V ENTILATION SYSTEM, W8 150 FRESH AIR VENTILATION CONTROL 7 68-0282—07 Setting the control... 1. Be sure power is turned on. 2. Set the V entilation S tandard on the con trol. 3. Set the bedrooms dial. 4. Set the area (sq f t) dial. 5. Set the airflow (cfm) dial. 6. Press the test button and observe the lights: Green light is flas ...

  • Honeywell Y8150 - page 8

    Y8150 FRESH AIR V ENTILATION SYSTEM, W8 150 FRESH AIR V ENT ILATION CONTROL 68-0282—0 7 8 CHECKOUT In this section, make sure the ventilation system is operating correctly . 1. On thermostat, set Fan swit ch to Auto and System switch to Off . 2. Set any remote swi tches throughout the house in the Off position. 3. On the W8150, set the control sw ...

  • Honeywell Y8150 - page 9

    Y8150 FRESH AIR V ENTILATION SYSTEM, W8 150 FRESH AIR VENTILATION CONTROL 9 68-0282—07 HV AC fan is running all the time Device is set to override • Move switch to On position to allow for automatic opera tion. Remote switch is on • Adjust remote switch to desired position. Thermostat Fan switch is in On position • Normal ope ration. HV AC ...

  • Honeywell Y8150 - page 10

    Y8150 FRESH AIR V ENTILATION SYSTEM, W8 150 FRESH AIR V ENT ILATION CONTROL 68-0282—0 7 10 WIRING DIAGRAMS Consult thermo stat Installation Instructions for alternate terminal designations. Fig. 1. Single transformer , conventiona l system. Fig. 2. Dual tran sforme r , conventional system. Fig. 3. Multi-st age conventional sys tem. Fig. 4. Wiring ...

  • Honeywell Y8150 - page 11

    Y8150 FRESH AIR V ENTILATION SYSTEM, W8 150 FRESH AIR VENTILATION CONTROL 11 68-0282—07 Fig. 5. Wiring hea t pump with emergency heat. Fig. 6. Wiri ng with a PC8900. Fig. 7. Using a remote switch or timer . Fig. 8. W iring to an HR V/ERV . Fig. 9. Wiring an exhaust fan. Wake Room System Fan Heat Auto AM DST Tue Y C RW 2 E G O Y 1 W 1 C RW 2 E G O ...

  • Honeywell Y8150 - page 12

    Y8150 FRESH AIR V ENTILATION SYSTEM, W8 150 FRESH AIR V ENT ILATION CONTROL Automation and Co ntrol Solutions Honeywell Internationa l Inc. 1985 Douglas Drive North Golden Valley, MN 55422 Honeywell Limited-Honeywell Limitée 35 Dynamic Drive Toronto, Ontario M1V 4Z9 customer.honeywell.com ® U.S. Regi stered T rademark © 201 1 Honeywell Inte rnat ...

Fabricant Honeywell Catégorie Ventilation Hood

Les documents que nous recevons du fabricant de l'appareilHoneywell Y8150 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Honeywell
- manuels d’utilisations Y8150
- fiches produit Honeywell
- dépliants
- ou étiquettes-énergie Honeywell Y8150
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Honeywell Y8150.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Honeywell Y8150, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Honeywell Y8150. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Honeywell Y8150.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Honeywell Y8150, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Honeywell Y8150 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Honeywell Y8150.

Le manuel d’utilisation complet Honeywell, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Honeywell Y8150 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Honeywell Y8150, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lHoneywell Y8150 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Honeywell Y8150 - qui devraient nous aider dans les premières étapes lors de l'utilisation Honeywell Y8150
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Honeywell Y8150
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Honeywell Y8150 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Honeywell Y8150?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Honeywell Y8150, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Honeywell Y8150 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)