Homelite UT08934B - page 1
OPERA T OR'S MANUAL V ac Att ack II Blower / V acuum UT08932, UT08934 and UT08934B SA VE THIS MANUAL FOR FUTURE REFERENCE Y our new blower has been engineered and manufactured to Homelite’s high st andard for dependability , ease of operation, and operator safety . Properly cared for , it will give you years of rugged, trouble-free performan ...
-
Homelite UT08934B - page 2
Page 2 ■ ■ ■ ■ ■ Introduction ................................................................................................................................................................... 2 ■ ■ ■ ■ ■ General Safety Rules ....................................................................................................... ...
-
Homelite UT08934B - page 3
Page 3 GENERAL SAFETY RULES W ARNING: Read and understand all instructions. Failure to follow all instructions listed below may result in electric shock, fire and/or serious personal injury. ■ ■ ■ ■ ■ Do not allow children or untrained individuals to use this unit. ■ ■ ■ ■ ■ Never start or run the engine inside a closed area; br ...
-
Homelite UT08934B - page 4
Page 4 ■ ■ ■ ■ ■ Do not operate vacuum without vacuum bag installed; flying debris could cause serious injury. Always close vacuum bag completely before operating. ■ ■ ■ ■ ■ Always hold the blower in your right hand, refer to the “Op- eration Instructions,” later in this manual for additional in- formation. ■ ■ ■ ■ ? ...
-
Homelite UT08934B - page 5
Page 5 SYMBOLS Some of the following symbols may be used on this tool. Please study them and learn their meaning for safe operation of this product. SYMBOL NAME EXPLANATION Safety Alert Symbol Precautions that involve your safety. . Read the Operator’s Manual To reduce the risk of injury, user must read and understand operator’s manual before u ...
-
Homelite UT08934B - page 6
Page 6 The following signal words and meanings are intended to explain the levels of risk associated with this product. SYMBOL SIGNAL MEANING DANGER: Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. WARNING: Indicates a potentially hazardous situation which, if not avoided, could result in d ...
-
Homelite UT08934B - page 7
Page 7 SPECIFICATIONS Weight ............................................................................................................................... ...................... 10.4 lbs. (4.7 kg.) Engine displacement ............................................................................................................ ..................... ...
-
Homelite UT08934B - page 8
Page 8 FEA TURES INSTRUCTIONS When unpacking the blower: ■ Carefully remo ve the b lower and accessories from the bo x . ■ Make sure that all items listed in the packing list are in- cluded. ■ Inspect the blower carefully to make sure no breakage or damage occurred during shipping. ■ Do not discard the packing material until you have care- ...
-
Homelite UT08934B - page 9
Page 9 W ARNING: Stop the engine and disconnect the spark plug wire before installing parts, making adjustments, cleaning, or when not in use. Failure to do so could result in possible serious personal injury. ASSEMBLING THE BLOWER TUBES See Figure 2. 1. Screw the nozzle onto the upper blower tube and tighten securely. Check tightness after initial ...
-
Homelite UT08934B - page 10
Page 10 ASSEMBL Y INLET COVER DOOR DOOR KNOB W ARNING: Stop the engine and disconnect the spark plug wire before installing par ts, making adjustments, cleaning, or when not in use. F ailure to do so could result in possible serious personal injury . INSTALLING THE VACUUM TUBES See Figures 5 and 6. To install the vacuum tubes: 1. Screw the upper an ...
-
Homelite UT08934B - page 11
Page 11 OPERA TION PREMIUM EXACT MIX™ (50:1) GASOLINE OIL 1 gallon (US) 2.6 oz. 1 Liter 20 cc (20 ml) FILLING THE TANK W ARNING: Always stop the engine before filling the fuel tank. Never add fuel to a machine with a running or hot engine. Move at least 30 ft. (9 m) from the refueling area before starting engine. Do not smoke while filling the ta ...
-
Homelite UT08934B - page 12
Page 12 OPERA TION STARTING AND STOPPING See Figure 7. Star ting the product differs depending on whether the engine is cold or warm. Refer to the label on the air filter base for choke positions A , B , and C . TO START A COLD ENGINE: 1. Place the blower on a flat, bare surface. 2. Push the primer bulb, slowly, 5 times. 3 . Move the choke lever to ...
-
Homelite UT08934B - page 13
Page 13 ■ Operate blower at the lowest possible throttle speed to do the job. ■ Check your equipment before operation, especially the muffler, air intakes and air filters. ■ Use rakes and brooms to loosen debris before blowing. ■ In dusty conditions, slightly dampen surfaces when water is available. ■ Conserve water by using power blowers ...
-
Homelite UT08934B - page 14
Page 14 MAINTENANCE W ARNING: Use only original manufacturer's replacement parts, accessories and attachments. Failure to do so can cause possible injury, poor performance and may void your warranty. REPLACING AND CLEANING THE AIR FIL- TER See Figure 13. For proper performance and long life, keep air filter clean. 1. Push down on the latch of ...
-
Homelite UT08934B - page 15
Page 15 FUEL CAP W ARNING: A leaking fuel cap is a fire hazard and must be replaced immediately. The fuel cap contains a non-serviceable filter and a check valve. A clogged fuel filter will cause poor engine perfor- mance. If performance improves when the fuel cap is loosened, the check valve may be faulty or filter clogged. Replace the fuel cap if ...
-
Homelite UT08934B - page 16
Page 16 PROBLEM POS SIBLE CAUSE SOLUTION IF THESE SOLUTIONS DO NO T SOL VE THE PR OBLEM CONT A CT Y OUR A UTHORIZED SER VICING DEALER. Engine will not star t: Engine star ts but will not accel- erate: Engine star ts but will only run at high speed at half choke: Engine does not reach full speed and emits excessive smoke: Engine star ts, runs, and a ...
-
Homelite UT08934B - page 17
Page 17 W ARRANTY LIMITED WARRANTY STATEMENT Homelite Consumer Product, Inc. warrants to the original retail purchaser that this HOMELITE product is free from defect in material and workmanship and agrees to repair or replace, at Homelite Consumer Products, Inc.’s discretion, any defective product free of charge within these time periods from the ...
-
Homelite UT08934B - page 18
Page 18 HOMELITE CONSUMER PRODUCTS, INC. LIMITED W ARRANTY FEDERAL AND CALIFOR- NIA EMISSION CONTR OL SYSTEMS NONRO AD AND SMALL OFF-RO AD ENGINES The U .S. Environmental Protection Agency (EP A), the Califor nia Air Resources Board (CARB), and Homelite Consumer Products , Inc. are pleased to explain the Emission Control System Warranty on your non ...
-
Homelite UT08934B - page 19
Page 19 W ARRANTY EMISSIONS MAINTENANCE SCHEDULE AND WARRANTED PARTS LIST Emissions Parts Inspect Before Clean Every Replace Every Clean Every Each Use 5 Hours 25 Hours or Yearly 25 Hours or Yearly AIR FILTER ASSY INCLUDES: FILTER .............................................................................. X ...................................... ...
-
Homelite UT08934B - page 20
983000-257 HOMELITE CONSUMER PRODUCTS, INC. 1428 Pearman Dairy Road Anderson, SC 29625 Post Office Box 1207, Anderson, SC 29622 Phone 1-800-242-4672 www.homelite.com W ARNING: The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects or other reproductive harm CALIFORNIA PROPOSITION 65 S ...
Avez-vous une question à propos de Homelite UT08934B?
Utiliser le formulaire ci-dessous
Si vous n’avez pas résolu votre problème avec Homelite UT08934B, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Homelite UT08934B il est probable qu’il a envie de partager la façon de le résoudre.