Manuel d’utilisation StreamLight CPMC-1553R

22 pages 0.14 mb
Télécharger

Aller à la page of 22

Summary
  • StreamLight CPMC-1553R - page 1

    CPMC-1553R User’s Guide ...

  • StreamLight CPMC-1553R - page 2

    CA.DT.356-0e MARCH, 2002 CPMC- 1553R User’s Guide ...

  • StreamLight CPMC-1553R - page 3

    Corporate Headquarters 150, rue Marcellin Berthelot ZI Toulon -Es t BP 244 83078 TOUL ON C edex 9 France Tel : +33 - (0) 4 94 16 34 00 Fax : +33 - (0) 4 94 16 34 01 USA Headquarters 1203 New Hope Road Ralei gh - NC 27610 USA Tel : +1 - (800) 848 23 30 Tel : +1 - (919) 231 80 00 Fax : +1 - (919) 231 8 001 International Sales Department 67, rue du C ...

  • StreamLight CPMC-1553R - page 4

    Thales C om puters - i - CPMC- 1553R U ser’s Guide , CA.D T.35 6-0e Table of C ontent s Chapter 1 Introduction .......................................................................................................... ...................... 1-1 1.1 Manual Overview.................................................................................... ...

  • StreamLight CPMC-1553R - page 5

    Thales C om puters 1-1 CPMC- 1553R U ser’s Guide , CA.D T.3 56-0e Chapter 1 − − − − Introduction 1.1 Manual Overview This manu al describes the CPMC-1553R board from Thales Com puters. Chapter 1 summarizes the board’s features and provides installation instructions. Chapter 2 describes its functional characteristics. Appendix A is a lis ...

  • StreamLight CPMC-1553R - page 6

    Thales C om puters 1-2 CPMC- 1553R U ser’s Guide , CA.D T.3 56-0e 1.2 CPMC-1553R Feature s The CPMC-1553R is a si ngle, con duction-cooled, PMC card w ith two du al-redundan t MIL-STD-1553 Buses. The card has th e following features: • Two ILC- DDC BU-61688 Mini- ACE MIL-S TD-1553 interface devi ces (single version available) - 64kBx 16 shared ...

  • StreamLight CPMC-1553R - page 7

    Thales C om puters 1-3 CPMC- 1553R U ser’s Guide , CA.D T.3 56-0e 1.3 CPMC-1553R Op tions Figure 2 s hows the s tandard options availa ble for the CPMC- 1553R. CPMC- 1553R- __ __        Environm ent        Industrial/-SA ............................................................................... ...

  • StreamLight CPMC-1553R - page 8

    Thales C om puters 2-1 CPMC- 1553R User’s Guide , CA.D T.3 56-0 e Chapter 2 − − − − Operation 2.1 Functional Descrip tion The CPMC-1553R is a PMC card w ith one or two, du al-redun dant MIL-STD-1553B bu ses, eigh t user inputs, and eigh t user outputs. The board interf aces to the us er I/O through the PMC conn ector Pn4. T w o PMC connec ...

  • StreamLight CPMC-1553R - page 9

    Thales C om puters 2-2 CPMC- 1553R User’s Guide , CA.D T.3 56-0 e 2.2 PCI Bus Inter face An Altera FLEX10 PLD provides the interface betw een the PCI Bus and the ILC- DDC Mini-ACE device. The FLEX10 operat es at 33MHz, is pow ered by 5V or 3.3V , has a 32- bit data path, and is compli ant with the PCI L ocal Bus Specification, R evision 2.1. The ...

  • StreamLight CPMC-1553R - page 10

    Thales C om puters 2-3 CPMC- 1553R User’s Guide , CA.D T.3 56-0 e Table 3. Su mmary o f Implemented P CI Co nfigurat io n Registers Regist er Name Address (0x) Read/Write Def ault Value (0x) Vendor ID 00 Read 151E Device I D 02 Read 0001 Comm and Register 04 Read/Write 0000 Status Regis ter 06 Read/Write 0400 Revision I D 08 Read 03 or higher Cla ...

  • StreamLight CPMC-1553R - page 11

    Thales C om puters 2-4 CPMC- 1553R User’s Guide , CA.D T.3 56-0 e 2.2.1.4 Sta tus Regi ster The Statu s Register is a 16-bit read/w rite register that prov ides the status of bus- related even ts. Read transactions tell you the current status of the bits. The Status Register is cleared by writing a logic on e to that bit. Writing a logic zero has ...

  • StreamLight CPMC-1553R - page 12

    Thales C om puters 2-5 CPMC- 1553R User’s Guide , CA.D T.3 56-0 e 2.2.1.8 Latency Tim er Register The L aten cy Timer regi ster is n ot supported. 2.2.1.9 He ader Type R egister The Header Ty pe register is an 8-bit, read-only regist er that identifies the CPMC-1553R board as a sin gle funct ion device. This reg ister returns a value of 0x 00 whe ...

  • StreamLight CPMC-1553R - page 13

    Thales C om puters 2-6 CPMC- 1553R User’s Guide , CA.D T.3 56-0 e 2.2.1.15 Ex pansi on ROM Base Addres s Regis ter The Expansion RO M Ba se Add ress Re gister is no t support ed. 2.2.1.16 In terrupt Lin e Register The Interru pt Line Register is an 8-bit, read/w rite register that defines which sy stem interru pt reques t line (on the system inte ...

  • StreamLight CPMC-1553R - page 14

    Thales C om puters 2-7 CPMC- 1553R User’s Guide , CA.D T.3 56-0 e Table 7. Mapping of PCI Memory Space to ACE Internal Regis ters PCI Address (AD15..AD0) ACE Addres s (ADDR15..ADDR0) Read/Write Description 0000 0000 Read/Write AC E#1 – Interru pt Mask Register 0002 0001 Read/Write AC E#1 – Conf iguration Register #1 0004 0002 Read/Write AC E# ...

  • StreamLight CPMC-1553R - page 15

    Thales C om puters 2-8 CPMC- 1553R User’s Guide , CA.D T.3 56-0 e Table 7. Ma pping of PCI M emory Space to ACE Interna l Reg isters - Continue d PCI Address (AD15..AD0) ACE Addres s (ADDR15..ADDR0) Read/Write Description 0080 0000 Read/Write AC E#2 – Interru pt Mask Register 0082 0001 Read/Write AC E#2 – Conf iguration Register #1 0084 0002 ...

  • StreamLight CPMC-1553R - page 16

    Thales C om puters 2-9 CPMC- 1553R User’s Guide , CA.D T.3 56-0 e 2.2.2.2 ACE Configuration and User I/O Register T he A CE conf iguration used on th e board can be read via PCI I/O space def ined in BAR1, w ith an address offs et of 0x0800. In addition, this register also provides the m eans for s oftware to read the eight input bits an d contro ...

  • StreamLight CPMC-1553R - page 17

    Thale s Computers 2-10 CPMC-1553 R User’s Gui de, CA.DT .356-0e 2.2.2.4 ACE Reset Regi ster This read/w rite register is accessible at 0x 0808, BAR 1. On ly bit 0 is used. After a PC I reset th e register reads 0x00000001. To gene rate a reset t o both A CE chips wri te a 0 to bit 0. A 0 holds both ACEs in reset. Write a 1 to bit D0 to unreset bo ...

  • StreamLight CPMC-1553R - page 18

    Thale s Computers 2-11 CPMC-1553 R User’s Gui de, CA.DT .356-0e 2.2.3 PCI I /O Space The PCI I/O space is not utilized by th e CPMC-1553R board. 2.2.4 Interru pt A (INT A*) The CPMC- 1553R board g enerates INTA* on the PC I Bus w hen either of th e Mini-A CE devices generates an in terrupt or an in terrupt occurs f rom one of the user-defined inp ...

  • StreamLight CPMC-1553R - page 19

    Thale s Computers 2-12 CPMC-1553 R User’s Gui de, CA.DT .356-0e Table 11. Pn 4 Signal De finition s Pin Signal Pin Signal 1 TX/RX-A _1_DIRECT 2 RTAD0_1 3 TX/RX-A _1*_DIRECT 4 T X/RX-A _1_TRAN S 5 RTAD1_1 6 T X/RX-A_1*_TRANS 7 TX/RX- B_1_DIRECT 8 R TAD2_1 9 TX/RX- B_1*_D IRECT 10 TX/ R X- B_ 1_ TRA NS 11 RTAD3_1 12 TX/RX- B_1* _TRANS 13 TX/RX-A _2 ...

  • StreamLight CPMC-1553R - page 20

    Thale s Computers 2-13 CPMC-1553 R User’s Gui de, CA.DT .356-0e 2.4 Power Requ irements The CPMC- 1553R uses 3.3 v olts and 5 v olts pow er. VIO, +12 vol ts, and –12 v olts are n ot used. The 3.3 volt supply pow ers the PCI interface and the 5 volt s upply pow ers each of the ACEs. Typical cu rrent draw is at 25 ° C at the “T ypical” power ...

  • StreamLight CPMC-1553R - page 21

    Thales C om puters A-1 C PMC-15 53R Us er’s Gu ide, C A.DT .35 6-0e Appendix A − − − − List of Abbrevia tions ACE Advanced Commun ication Engine BAR Base Address Register BC Bus Controll er BIST Built-In Self-T est Register BIT Built-In-T est CIS Card Information Structure MT Monitor Termin al IEEE Institute of Electrical and Electronic E ...

  • StreamLight CPMC-1553R - page 22

    Vos rema rques su r ce document / Your commen ts on this docum ent Titre / Title: CPMC-1553R User’s G uide No de référence / R eference No: CA.DT .356-0e ID producti on / Pr oduct ID: 990 3 ERREURS DETE CT EES / ERRORS FOUND IN T HIS DOCUMENT AMELIORATIONS SUGGEREE S / SUGGEST IONS FOR IMPROVEMENT T O THIS DOCUMENT ■ Vos rema rques et sugg es ...

Fabricant StreamLight Catégorie Personal Computer

Les documents que nous recevons du fabricant de l'appareilStreamLight CPMC-1553R peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques StreamLight
- manuels d’utilisations CPMC-1553R
- fiches produit StreamLight
- dépliants
- ou étiquettes-énergie StreamLight CPMC-1553R
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation StreamLight CPMC-1553R.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation StreamLight CPMC-1553R, manuels d’entretien, brefs manuels ou manuels de l’utilisateur StreamLight CPMC-1553R. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit StreamLight CPMC-1553R.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil StreamLight CPMC-1553R, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser StreamLight CPMC-1553R par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs StreamLight CPMC-1553R.

Le manuel d’utilisation complet StreamLight, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel StreamLight CPMC-1553R - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières StreamLight CPMC-1553R, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lStreamLight CPMC-1553R qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil StreamLight CPMC-1553R - qui devraient nous aider dans les premières étapes lors de l'utilisation StreamLight CPMC-1553R
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de StreamLight CPMC-1553R
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service StreamLight CPMC-1553R dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de StreamLight CPMC-1553R?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec StreamLight CPMC-1553R, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec StreamLight CPMC-1553R il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)