Manuel d’utilisation MPI Technologies D60425-06

33 pages 0.46 mb
Télécharger

Aller à la page of 33

Summary
  • MPI Technologies D60425-06 - page 1

    Host Print Set-up Guide D60425-0 6 November 2007 MPI Tech A/S Vadstrupvej 35 2880 Bagsvaerd Denmark Tel: +45 44 36 60 00 Fax: +45 44 36 61 11 www.mpitech.com ...

  • MPI Technologies D60425-06 - page 2

    Table of contents 1 PSF/MVS AFP Printing Using TCP/IP .................................................. 3 1.1 PSF/MVS direct attachment .............................................................. 3 1.2 PSF/MVS start-up proc edure ............................................................. 3 2 z/OS SCS Printing Using TN3270e .................. ...

  • MPI Technologies D60425-06 - page 3

    1 PSF/MVS AFP Printing Using TCP/IP This chapter provides information on h ow to create MVS definitions for printing from PSF/MVS via TCP/IP. T he fo llowing topics are addressed: JES printer statements PSF Start-up procedure Once these parameters have been configur ed, and the basic TCP/IP installation of the PrintServer with IPDS has been comple ...

  • MPI Technologies D60425-06 - page 4

    //PRT420 CNTL //PRT420 PRINTDEV FONTDD=*.FONT01, /* FONT LIBRARY DD */ // OVLYDD=*.OLAY01, /* OVERLAY LIBRARY DD */ // PSEGDD=*.PSEG01, /* SEGMENT LIBRARY DD */ // PDEFDD=*.PDEF01, /* PAGEDEF LIBRARY DD */ // FDEFDD=*.FDEF01, /* FORMDEF LIBRARY DD */ // JOBHDR=*.JOBHDR, /* JOB HEADER SEPARATOR OUTPUT */ // JOBTRLR=*.JOBTLR, /* JOB TRAILER SEPARATOR ...

  • MPI Technologies D60425-06 - page 5

    2 z/OS SCS Printing Using TN3270e This chapter provides examples of ho w to set up SCS printing using TN3270e. 2.1 TN3270E Setup using z/OS Communication Server The IBM z/OS is capable of supporting TN32 70e sessions comm unic ating directly. The following describes the requi red mainframe definitions for a Lin kCom or DocOut. It is assumed that th ...

  • MPI Technologies D60425-06 - page 6

    3 Mainframe Printing Using SNA This chapter provides: Note: The descriptions below ap pear in Et hernet and Toke n Ring versions respectively, and the sections are marked accordingl y. Be sure to select the right section . • sample LU1 printer logmode definitions: 3.1 Logmode • sample definitions for installat ion i n association with a locally ...

  • MPI Technologies D60425-06 - page 7

    3.2 Ethernet - PS PU definition for 3174 Sample definition for installation in association with a lo cally attached 3174. 3174 VTAM definiti on V1SNA1C2 VBUILD TYPE=LOCAL * * LOCAL SNA 3174 * V1LS1C2 PU CUADDR=3C3, X DLOGMOD=D4A32782, X PACING=3, X VPACING=3, X MAXBFRU=10, X SSCPFM=USSSCS, X USSTAB=VUSSTAB, X LOGTAB=VMODETAB, X MODETAB=VMODETAB * * ...

  • MPI Technologies D60425-06 - page 8

    PrintServer Definition file extract &&??##N1,0# ; Start of file - Don't remove this ! ;------------------------------------------------------------------------ ; Configuration for the Ethernet PrintServer ; (This is an example. Please modify the parameters to match ; your configuration). ; 00824001 ;------------------------------------ ...

  • MPI Technologies D60425-06 - page 9

    PU/LU Definitions SPPRKEN VBUILD TYPE=SWNET, SWITCHED MAJOR NODE MAXNO=1, MAXGRP=1 * STATOPT=‘NN PRINTER’ PA01B91 PU ADDR=C1, IDBLK=017, IDNUM=E2961, DISCNT=NO, MAXOUT=1, MAXDATA=1033, MODETAB=MTABPS, PACING=3, VPACING=3, MAXPATH=1, PUTYPE=2, DLOGMOD=MODPS * PATH B91PATH DIALNO=020400036E0035C9,GRPNM=ZTOKEN,GID=1,PID=1 * TA01B911 LU LOCADDR=2,D ...

  • MPI Technologies D60425-06 - page 10

    3.4 Token Ring - PS PU definition for 3174 Sample definition for installation in association with a lo cally attached 3174. 3174 VTAM definiti on V1SNA1C2 VBUILD TYPE=LOCAL * * LOCAL SNA 3174 * V1LS1C2 PU CUADDR=3C3, X DLOGMOD=D4A32782, X PACING=3, X VPACING=3, X MAXBFRU=10, X SSCPFM=USSSCS, X USSTAB=VUSSTAB, X LOGTAB=VMODETAB, X MODETAB=VMODETAB * ...

  • MPI Technologies D60425-06 - page 11

    PrintServer Definition file extract &&??##N1,0# ; Start of file - Don't remove this ! ;------------------------------------------------------------------------ ; Configuration for the Token Ring PrintServer ; (This is an example. Please modify the parameters to match ; your configuration). ; 00824001 ;---------------------------------- ...

  • MPI Technologies D60425-06 - page 12

    PU/LU Definitions SPPRKEN VBUILD TYPE=SWNET, SWITCHED MAJOR NODE MAXNO=1, MAXGRP=1 * STATOPT=‘NN PRINTER’ PA01B91 PU ADDR=C1, IDBLK=017, IDNUM=E2961, DISCNT=NO, MAXOUT=1, MAXDATA=1033, MODETAB=MTABPS, PACING=3, VPACING=3, MAXPATH=1, PUTYPE=2, DLOGMOD=MODPS * PATH B91PATH DIALNO=020400036E0035C9,GRPNM=ZTOKEN,GID=1,PID=1 * TA01B911 LU LOCADDR=2,D ...

  • MPI Technologies D60425-06 - page 13

    4 Configuration of MS SNA/ HIS Server This chapter provides examples of ho w to set up SCS printing using TN3270e. 4.1 General setup 4.1.1 Adding DLC 802.2 protocol to your Windows Server / Workstation In order to communicate vi a Token ring or Ether net over SNA, you must add the DLC protocol to your Window s Server or Workstation running SNA Serv ...

  • MPI Technologies D60425-06 - page 14

    4.1.2 SNA Server confi guration – Create a link You must define the Server LAN card to be used to communicate wi th the host. - Folder Link Services , make a right cli ck and select Link Service. Select DL C 802.2 Link Service from the list. - In the DLC 802.2 Link Service Prop erties windo w, select the LA N card you want to use. 4.1.3 SNA Serve ...

  • MPI Technologies D60425-06 - page 15

    Connections : General Connections : Address Note : Remote Network Address must match the Ho st MAC Address (TIC) 15 ...

  • MPI Technologies D60425-06 - page 16

    Connections : System Identification Note : local Node ID must match the ID_NUM and ID_BLOCK parameters of the VTAM PU Definition Connections : System Identification Note : MAX BTU Le ngth must match the MAX_DATAD parameter of the VTAM PU Definition 16 ...

  • MPI Technologies D60425-06 - page 17

    4.2 SNA Server configuration – Create a Printer LU Attached to the connection, you must create yo ur pri nter LU. In order to run with MPI Router, you must define a LUA LU. - Make a right click on your conne ction a nd select Application LU (LUA). - This new windo w app ears: Note : The number specified for LU must match the LOCADDR parameter of ...

  • MPI Technologies D60425-06 - page 18

    4.3 Configuring BlueServer for SNA communication 4.3.1 Setup Connection tab Notes: - The other tabs “IPDS Settings”, “Paper C ontrols”, are not used in t his case. - The SCS Settings tab is only used only for SCS printout. 18 ...

  • MPI Technologies D60425-06 - page 19

    4.4 Loading the Router Mainframe and Parser 4.4.1 Microsoft SNA/HI S status indication The PSNA201 is SSCP 4.4.2 Blue Server status indication With this configuration, you are now able to p rint SCS or IPDS jobs from your Mainframe IBM host. 19 ...

  • MPI Technologies D60425-06 - page 20

    4.5 Configuring DocOut for SNA communication 4.5.1 Setup LUA(LU1) tab Select AFP/IPDS (PSF) using SNA (LU1/LUA) or SCS (S/390) using SNA (LU1/LUA) Check Confi guration: Select: Save Configurat ion 20 ...

  • MPI Technologies D60425-06 - page 21

    4.5.2 Microsoft SNA/HI S status indication The PSNA201 is SSCP 4.5.3 DocOut status indication With this configuratio n, you are now able to print SCS or I PDS jobs from your Mainframe IBM host. 21 ...

  • MPI Technologies D60425-06 - page 22

    5 PSF/AIX IPDS Printing Using TCP/IP This chapter provides details on: Adding a TCP/IP attached printer Set up of the KEEPA LIVE TCP/IP fe ature The basic TCP/IP installation of the Prin tServer (IPDS) must be completed before direct AFP / IPDS from PS F/AIX will be possible. 5.1 Adding TCP/IP attached printer The port number is defined in the PSF/ ...

  • MPI Technologies D60425-06 - page 23

    5.3 AIX KEEPALIVE support The no (network options) command can be used by the root user to configure KEEPALIVE frequencies. no -o tcp_keepid le=nnn no -o tcp_keepintvl=nnn when nnn is in half- s econ ds. The command tcp_keepidle speci fies the interval of i nactivity causing the TCP to generate a KEEPALIVE transmission for an application that reque ...

  • MPI Technologies D60425-06 - page 24

    6 PSF/400 AFP Printing Using TCP/IP This chapter provides configuration gu idelines for AS/400 IPDS Printing over TCI/IP. These guidelines ar e applicable for OS/400 version 3.7, 4.X and 5.X. The examples of completed screens given are for OS/400 version 4.X and 5.X and may contain some additional parameters not seen in version 3.7, these may be ig ...

  • MPI Technologies D60425-06 - page 25

    A completed PSF Configur at ion looks like this: PSF Configuration Information Page 1 PSF configuration: NETWRKPRT Library: AFP User resource library . . . . . . . . . . . . . : *JOBLIBL IPDS pass through . . . . . . . . . . . . . . . : *YES Activate release timer. . . . . . . . . . . . . : *NORDYF Release timer . . . . . . . . . . . . . . . . . : ...

  • MPI Technologies D60425-06 - page 26

    Display Device Description Page 1 5716SS1 V4R4M0 981108 BLDRB1 09/11/98 12:02:59 Device description . . . . . . . . : DEVD < DeviceName > Option . . . . . . . . . . . . . . : OPTION *ALL Category of device . . . . . . . . : *PRT Device class . . . . . . . . . . . : DEVCLS *LAN Device type. . . . . . . . . . . . : TYPE *IPDS Device model . . . ...

  • MPI Technologies D60425-06 - page 27

    7 SCS/DCA Printing Using TN5250e To set up TN5250, configure your PrintS erver using PrintGuide (see the manual Getting Started with PrintGuide , doc. no. 60364 on the Utility Pack). Start PrintGuide, select Telnet Pri nt Settings (Figure 7), select TN5250e as Connection Type and enter the Device N ame for your <Pri ntServer>. On many AS/400 ...

  • MPI Technologies D60425-06 - page 28

    Prerequisites: • AS/400 is configured and running TCP/IP • Firmware level* on the inte rface is at least S80 xxx.360 • Release of PrintGuide* being used is at least S42 065.100 * Latest versions can be obtain ed from the MPI Tech web page 1. Install the Prin t Server using Print Guide. Define the IP Address, SubnetMask and Gate way values in ...

  • MPI Technologies D60425-06 - page 29

    3. Double-click on the highlighted session. 29 ...

  • MPI Technologies D60425-06 - page 30

    Type in the Device N ame . This must be a unique name o n the AS/400 that you wish to connect to . It can have up to 10 characters. Type in the Host IP Address of the AS/400 you wi sh to connect to. The standard Telnet port 23 is used for the Host Port and is predefined. Click OK and then downlooad the setti ngs to the PrintServer, sel ecting the o ...

  • MPI Technologies D60425-06 - page 31

    The value of CTL should match the virtual controller on the system (Normally QVIRCD0001) The value for TEXT is optional. Create Device Desc (Printer) (CRTDEVPRT) Type choices, press Enter. Device description . . . . . . . DEVD > DEVXXXX Device class . . . . . . . . . . DEVCLS > *VRT Device type . . . . . . . . . . TYPE > 3812 Device model ...

  • MPI Technologies D60425-06 - page 32

    8 AS/400 Printing using TCP/IP LPR/LPD This chapter provides: AS/400 definitions Once these parameters have been configur ed, and the basic TCP/IP installation of the PrintServer ha s been complet ed, printing from AS/400 will be possible. This will use the AS/400 Host Print Transform to format and tra nslate EBCDIC data to the printer language sel ...

  • MPI Technologies D60425-06 - page 33

    The value *IP must be used for CNNTYPE The value *OTHER must be used for DESTTYPE The value *YES must be used for TRANSFORM The value used for MRFTYPMDL will depend on the attached printer. Use the ‘F4’ to obtain a list of the possible choices The value used for INTNETADR must be th e sa me as the IP address of your PrintServer. 8.2 AS/400 prin ...

Fabricant MPI Technologies Catégorie Printer

Les documents que nous recevons du fabricant de l'appareilMPI Technologies D60425-06 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques MPI Technologies
- manuels d’utilisations D60425-06
- fiches produit MPI Technologies
- dépliants
- ou étiquettes-énergie MPI Technologies D60425-06
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation MPI Technologies D60425-06.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation MPI Technologies D60425-06, manuels d’entretien, brefs manuels ou manuels de l’utilisateur MPI Technologies D60425-06. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit MPI Technologies D60425-06.

Manuel d’utilisation complet de l’appareil MPI Technologies D60425-06, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser MPI Technologies D60425-06 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs MPI Technologies D60425-06.

Le manuel d’utilisation complet MPI Technologies, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel MPI Technologies D60425-06 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières MPI Technologies D60425-06, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lMPI Technologies D60425-06 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil MPI Technologies D60425-06 - qui devraient nous aider dans les premières étapes lors de l'utilisation MPI Technologies D60425-06
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de MPI Technologies D60425-06
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service MPI Technologies D60425-06 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de MPI Technologies D60425-06?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec MPI Technologies D60425-06, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec MPI Technologies D60425-06 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)