  • Mitsubishi Electronics FR-A800 - page 1

    INVERTER FR-A800/F800 Safety S top Function Instruction Manual CONTENTS 1. GENERAL DESCRIPTION .. .......................................... 2 2. INSTALLATION AND WIRING ...................................... 3 3. EXAMPLE OF SAFETY SYSTEM CONFIGURATION .... 7 4. TEST AND CHECKING FAILURE ............................... 10 5. SAFETY PARAMETERS OF FR ...

  • Mitsubishi Electronics FR-A800 - page 2

    1 Compliance with the EU Machin ery Directive – Functional Safety WA R N I N G  Any misuse of saf ety function could lead to per sonal injury or death, proper ty damage, or economic loss. T o ensure that the system complies fully with requirement of safety , make a system-level risk assessment. Mit subishi Electric Co. cannot assume responsibi ...

  • Mitsubishi Electronics FR-A800 - page 3

    2 GENERAL DESCRIP TION 1 GENERAL DESCRIPTION Features Mitsubishi FR-A800/F800 safety stop function prevents a dr ive fr om supplying rotatio nal energy to motor s. Dual safety channels ‘S1’ and ‘S2’ cut o ff th e gate-drive powe r for IGBT to turn off. Fig.1 FR-A800 /F800 safety stop functio n diagram Standards Mitsubishi FR-A800/F800 safet ...

  • Mitsubishi Electronics FR-A800 - page 4

    INSTALLATION AND WIRING 3 2 INST ALLA TION AND WIRING Installation Mitsubishi FR-A800/F8 00 safety stop function shoul d be used under following cond ition and environment. T able.1 The condition and envir onment for using safety stop functi on  The ND and HD ratings can be selecte d only for the FR-A800.  T emperature applicable for a ...

  • Mitsubishi Electronics FR-A800 - page 5

    4 INSTALLATION AND WIRING ● Wiring The safety related terminals are de scribed in T a ble.2 and T abl e.3 T able.2 The safety relate d terminals  S pecifications for conforming safety standards.  ON: The transistor is conducted. OF F: The transistor is not conducted. CAUTION  In order to meet safety stop, an approved safety relay u ...

  • Mitsubishi Electronics FR-A800 - page 6

    INSTALLATION AND WIRING 5 T able.3 T ruth t able of safety relat ed signals  ON: The transistor is conducted. OFF: The transistor is not conducted.  When not using the safety stop function, short across terminals S1 and PC, S2 and PC, a nd SIC and SD to use the inverter . (In the initial status, terminals S1 and PC, S2 and PC, and SIC a ...

  • Mitsubishi Electronics FR-A800 - page 7

    6 INSTALLATION AND WIRING ● Wire and ferrule specification T able.4 Wire and ferrule spec ification  Ferrules and tools are distributed by Phoenix Contact. ● Jumper cable The jumper cable between S1,S2 and PC termin al between SIC and SD terminal has been inst alled in the factory as shown in Fig.2. Fig.2. Short wire Before conne cting sa ...

  • Mitsubishi Electronics FR-A800 - page 8

    EXAMPLE OF SAFETY SYSTEM CONFIGURATION 7 3 EXAMPLE OF SAFETY SY STEM CONFIGURA TION ● FR-A800/F800 configuration exa mple  If the control logic is SINK logic, the common terminal is terminal SD. Fig.3 Safety system example with FR- A800/F800 NOTE • When starting up the system’ s operation, press the RESET switch to reset the safety stop ...

  • Mitsubishi Electronics FR-A800 - page 9

    8 EXAMPLE OF SAFETY SYSTEM CONFIGURATION ● Multiple inverter configuration exam ple Fig.4 When using multiple safety stop func tion inverters (FR-A800/F800) NOTE • Some models cannot be used together because thei r control logics are different. Refer to the SAFETY STOP FUNCTION MANUAL of each model. S 1 S 2 PC FR-A800/F800 SO R/L1 S/L2 T/L3 IGB ...

  • Mitsubishi Electronics FR-A800 - page 10

    EXAMPLE OF SAFETY SYSTEM CONFIGURATION 9 ● Safety controller configuration exa mple Fig.5 Safety system example with FR- A800/F800 NOTE • When starting up the system’ s operation, press the RESET switch to reset the safety stop function first. • In the above configuration, af ter reset of emergency stop button, drive will be in safe-state u ...

  • Mitsubishi Electronics FR-A800 - page 11

    10 TEST AND CHECKING FAILURE 4 TEST AND CHECKING F AIL URE I/O status and failure FR-A800/F800 safety re lated I/O status obeys the following truth t able. T able.5 T ruth t able of safety related signals  ON: The transistor is conducted. OF F: The transistor is not conducted.  When not using the safety stop function, short across termi ...

  • Mitsubishi Electronics FR-A800 - page 12

    SAFETY PARAMETERS OF FR-A800/F800 11 Diagnostic If the failure detected, FR-A800/F800 output ala rm signal and i ndicate ‘E.SAF’ at the display . In case of FR-A800/F800 output the alar m, please take following action. 1) Check the S1-SIC and S2-SIC input sign al logic is the same. If these are differe nt lo gic, collect the input signal and re ...

  • Mitsubishi Electronics FR-A800 - page 13

    12 REVISIONS Print Date Manual Number Revision Apr . 2013 BCN-A23228-001(E) First edition Jun. 2013 BCN-A23228-001-A(E) ● Multiple inverter configuration example Jul. 2014 BCN-A23228-001-B(E) Compatibility with the FR-F800 series Modification BCN-A23228-001-B(E) ...

  • Mitsubishi Electronics FR-A800 - page 14

    HEAD OFFICE: TOKYO BUILDING 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAP AN MITSUBISHI ELECTRIC EUROP E EUROPE B.V . German Branch Gothaer S traße 8 D-40880 Ratingen Phone: +49 (0) 21 02 / 486-0 Hotline: +49 2102 1805 000-76 5 /-766 Fax: +49 (0) 21 02 / 4 86-1 12 0 e mail: megfa-ma il@meg.mee.com www .mitsubishi-automatio n.com MITSUBISHI EL ...

Fabricant Mitsubishi Electronics Catégorie Electric Pet Fence

Les documents que nous recevons du fabricant de l'appareilMitsubishi Electronics FR-A800 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Mitsubishi Electronics
- manuels d’utilisations FR-A800
- fiches produit Mitsubishi Electronics
- dépliants
- ou étiquettes-énergie Mitsubishi Electronics FR-A800
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Mitsubishi Electronics FR-A800.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Mitsubishi Electronics FR-A800, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Mitsubishi Electronics FR-A800. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Mitsubishi Electronics FR-A800.

Manuel d’utilisation complet de l’appareil Mitsubishi Electronics FR-A800, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Mitsubishi Electronics FR-A800 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Mitsubishi Electronics FR-A800.

Le manuel d’utilisation complet Mitsubishi Electronics, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Mitsubishi Electronics FR-A800 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Mitsubishi Electronics FR-A800, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lMitsubishi Electronics FR-A800 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Mitsubishi Electronics FR-A800 - qui devraient nous aider dans les premières étapes lors de l'utilisation Mitsubishi Electronics FR-A800
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Mitsubishi Electronics FR-A800
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Mitsubishi Electronics FR-A800 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Mitsubishi Electronics FR-A800?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Mitsubishi Electronics FR-A800, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Mitsubishi Electronics FR-A800 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)