    D VS In s ert EF II Own e r's M an ual Featuring the Burner Tested and Listed by OMNI-Test Laboratories, Inc. Beaverton, Oregon Report # 028-F-73-5 ANSI Z21.88 • Direct Vent Fireplace Insert • Masonry or Factory Built (Metal) Wood-Burning Fireplace • Residential or Mobile Home WARNING: If the information in these instructions is not foll ...

  • Travis Industries DVS Insert EF II - page 2

    2 Introduction © Travis Industries 4060111 100-01175 Introduction We welcome you as a new owner of a DVS Insert. In purchasing this fireplace insert you have joined the growing ranks of concerned individuals whose selection of an energy system reflects both a concern for the environment and aesthetics. It is one of the finest home heaters the worl ...

  • Travis Industries DVS Insert EF II - page 3

    Table of Contents 3 © Travis Industries 4060111 100-01175 Introduction and Important Information Introduction ......................................................2 Safety Precautions Safety Precautions ............................................4 Features & Specifications Features ..........................................................6 ...

  • Travis Industries DVS Insert EF II - page 4

    4 Safety Precautions © Travis Industries 4060111 100-01175 IF YOU SMELL GAS: * Do not light any appliance * Extinguish any open flame * Do not touch any electrical switch or plug or unplug anything * Open windows and vacate building * Call gas supplier from neighbor's house, if not reached, call fire department This unit must be installed b y ...

  • Travis Industries DVS Insert EF II - page 5

    Safety Precautions 5 © Travis Industries 4060111 100-01175 Do not place clothin g or other flammable items on or near the heater. Because this heater can be controlled by a thermostat there is a possibility of the heater turning on and igniting any items placed on or near it. Li g ht the heater usin g the built- in piezo igniter. Do not use matche ...

  • Travis Industries DVS Insert EF II - page 6

    6 Features and Specifications © Travis Industries 4060111 100-01175 Features • Works During Power Outages (millivolt system) • High Efficiency • Optional Thermostat or Remote Control • Ember Fyre™ Burner for "Wood Fire" Look • Quiet Blower for Effective Heat Distribution • Convenient Operating Controls • Variable-Rate Hea ...

  • Travis Industries DVS Insert EF II - page 7

    Installation (for qualified installers only) 7 © Travis Industries 4060111 100-01175 Installation Warnings • Failure to follow all of the requirements may result in property damage, bodily injury, or even death. • This heater must be installed by a qualified installer who has gone through a training program for the installation of direct vent ...

  • Travis Industries DVS Insert EF II - page 8

    8 Installation (for qualified installers only) © Travis Industries 4060111 100-01175 Top Convection Deflector Install the top convection deflector as shown to the right. The deflector is shipped on top of the insert. The screws are shipped inside the owner's pack. Fireplace Requirements • Insert must be placed within a code-conforming mason ...

  • Travis Industries DVS Insert EF II - page 9

    Installation (for qualified installers only) 9 © Travis Industries 4060111 100-01175 Factory-Built (Metal) Wood-Burning Fireplace Requirements The damper (" A ") and grate (with log set) (" B ") must be removed (see the illustration below) The smoke shelf (" C "), internal baffles (" D "), screen (" E & ...

  • Travis Industries DVS Insert EF II - page 10

    10 Installation (for qualified installers only) © Travis Industries 4060111 100-01175 Clearances Due to the high temperature of the heater, it should be located out of traffic and away from furniture and draperies. Side Wall Combustible or Non-Combustible Mantel Combustible Top Facing Non-Combustible Facing Minimum Clearances k l m n x Sidewall to ...

  • Travis Industries DVS Insert EF II - page 11

    Installation (for qualified installers only) 11 © Travis Industries 4060111 100-01175 Face Sizing Face Height Width Notes Rawhide 22-1/2” 32” Victorian 22-1/2” 32” Rosario 21-9/16” 32” Cambridge 21-1/2” 33” Craftsman 21-1/2” 32” Classic Arched, Artisan 22 ” 30 ” Side begins arch 3-1/2” below top - 34” radius Metropolita ...

  • Travis Industries DVS Insert EF II - page 12

    12 Installation (for qualified installers only) © Travis Industries 4060111 100-01175 Face Mounting Brackets -- Arched, Metropolitan, Artisan Vict. Lace Faces Some Arched, Artisan, Metropolitan, and Victorian Lace Faces include old brackets that will not mount to the heater (see illustration below). For these faces, make sure to use the new mounti ...

  • Travis Industries DVS Insert EF II - page 13

    Installation (for qualified installers only) 13 © Travis Industries 4060111 100-01175 Gas Line Requirements MASSACHUSETTS INSTALLATIONS - WARNING: THIS PRODUCT MUST BE INSTALLED BY A LICENSED PLUMBER OR GAS FITTER WHEN INSTALLED WITHIN THE COMMONWEALTH OF MASSACHUSETTS. OTHER MASSACHUSETTS CODE REQUIREMENTS: • Flexible connector must not be long ...

  • Travis Industries DVS Insert EF II - page 14

    14 Installation (for qualified installers only) © Travis Industries 4060111 100-01175 Vent Requirements • The gas appliance and vent system must be vented directly to the outside of the building, and never be attached to a chimney serving a separate solid fuel or gas-burning appliance. Each direct vent gas appliance must use it's own separa ...

  • Travis Industries DVS Insert EF II - page 15

    Installation (for qualified installers only) 15 © Travis Industries 4060111 100-01175 Vent Restrictor WARNING : Restrictor adjustment should only be done by a qualified installer. Only those installations determined to be over-drafting require this adjustment. The best indication of over-drafting is a hyper-active flame pattern (flames that move t ...

  • Travis Industries DVS Insert EF II - page 16

    16 Installation (for qualified installers only) © Travis Industries 4060111 100-01175 Vent Location • A vent restrictor is built into the appliance to adjust the flow rate of exhaust gases. This ensures proper combustion for all vent configurations. Depending upon the vent configuration, you may be required to adjust the restrictor position. The ...

  • Travis Industries DVS Insert EF II - page 17

    Installation (for qualified installers only) 17 © Travis Industries 4060111 100-01175 Vent Connector Removal and Installation • The vent connector is shipped attached to the insert, but may be removed to facilitate tight installations. See the directions below for installation. 1. Route the flex vent through the chimney from above (leave an extr ...

  • Travis Industries DVS Insert EF II - page 18

    18 Installation (for qualified installers only) © Travis Industries 4060111 100-01175 Vent Connector Removal and Installation (continued) Vent Connector Removal Slide the connector to the rear. It will "snap" out. Pull the vent connector rod forward. Vent Connector Installation Attach the flex vent to the vent connector. Slide the insert ...

  • Travis Industries DVS Insert EF II - page 19

    Installation (for qualified installers only) 19 © Travis Industries 4060111 100-01175 Surround Panel Installation PANEL SIZE W IDTH HEIGHT PART # 8" x 10" Rectangular 40 -3/8" 28-7/8" 98500610 Arched (8” x 10”) 4 0 -3/8" 28-7/8" 98500622 10” x 13” Rectangular 44-3/8" 31-7/8" 98500611 1 Follow the dir ...

  • Travis Industries DVS Insert EF II - page 20

    20 Installation (for qualified installers only) © Travis Industries 4060111 100-01175 Installation of the On/Off Switch and Rheostat The on/off switch and rheostat may be installed in either the surround panels or control panel. See the illustration below for installation details. c a Disconnect the red and brown wires leading to the on/off switch ...

  • Travis Industries DVS Insert EF II - page 21

    Finalizing the Installation 21 © Travis Industries 4060111 100-01175 Glass Frame Removal and Installation Warning: The appliance must be completely cool before removing the glass. Warning: Do not strike or slam the glass. Open the four latches holding the glass frame in place (start with the two below the glass) - follow the directions shown to th ...

  • Travis Industries DVS Insert EF II - page 22

    22 Finalizing the Installation © Travis Industries 4060111 100-01175 Glass Frame Removal and Installation (continued) The spring pin can come loose from the latch assembly. This occurs when it is turned 1/4 turn when it is disengaged. Follow the directions below to re-install the spring pin if it becomes loose. To re-install the spring pin, first ...

  • Travis Industries DVS Insert EF II - page 23

    Finalizing the Installation 23 © Travis Industries 4060111 100-01175 Log Set Installation Install the rear log. The two pins install into holes on the log. Install the left log. This pin & bolt insert into holes in the bottom of the log. The right log installs the same way. When in place, the logs look like this. ...

  • Travis Industries DVS Insert EF II - page 24

    24 Finalizing the Installation © Travis Industries 4060111 100-01175 These 2 pins install into holes in the bottom of the left twig. The right twig installs over this pin. When in place, the log set should look like the pictures above. Use a kibble to cover any exposed screws. You may wish to flatten the kibble to provide better coverage. Place ot ...

  • Travis Industries DVS Insert EF II - page 25

    Finalizing the Installation 25 © Travis Industries 4060111 100-01175 Steps for Finalizing the Installation 1. Remove the glass (see page 21). NOTE: If using propane (LP) convert the appliance prior to installing the logs. 2. We recommend you purge the gas line at this time (with the glass removed). This allows gas to be detected once it enters the ...

  • Travis Industries DVS Insert EF II - page 26

    26 Finalizing the Installation © Travis Industries 4060111 100-01175 FINE TUNING THE EMBER-FYRE™ BURNER Each installation is affected by altitude, vent configuration, and fuel quality. Because of this, the restrictor and air shutter may need to be fine tuned to each installation. Follow the hints below to fine- tune the burner for optimum perfor ...

  • Travis Industries DVS Insert EF II - page 27

    Operation 2 7 © Travis Industries 4060111 100-01175 Before You Begin • Read this entire manual before you use your new heater (especially the section "Safety Precautions" on pages 4 & 5). Failure to follow the instructions may result in property damage, bodily injury, or even death. Location of Controls Open the access door to view ...

  • Travis Industries DVS Insert EF II - page 28

    2 8 Operation © Travis Industries 4060111 100-01175 Starting The Pilot Flame The pilot flame is required to ignite the main burners (it also plays a safety role). It should be left on once lit. It will stay lit unless the gas control valve is turned to "OFF". However, the pilot will go out if the gas is shut off, the propane tank runs ou ...

  • Travis Industries DVS Insert EF II - page 29

    Operation 2 9 © Travis Industries 4060111 100-01175 Starting the Heater for the First Time • Burn the heater at a high setting with the blower off for an extended period (up to 48 hours). This will cure the painted surfaces. Fumes from the paint curing and oil burning off the steel will occur. This is normal. We recommend opening a window to ven ...

  • Travis Industries DVS Insert EF II - page 30

    3 0 Operation © Travis Industries 4060111 100-01175 Adjusting the Blower Speed The blower helps transfer heat from the heater into the room. It will not turn on until the heater is up to temperature (approximately 10 minutes after starting). See the illustration below for instructions on adjusting the blower speed. OFF Turn the dial all the way co ...

  • Travis Industries DVS Insert EF II - page 31

    Maintenance 31 © Travis Industries 4060111 100-01175 Maintaining Your Heater's Appearance Fingerprints or other marks left on the optional plated surface may become etched in place if they are not wiped clean prior to turning the heater on. Clean the plated surfaces with denatured alcohol and a soft cloth (with the heater cool). Other cleaner ...

  • Travis Industries DVS Insert EF II - page 32

    32 Maintenance © Travis Industries 4060111 100-01175 Troubleshooting Table Problem: Possible Cause: Don't Call for Service Until You: Pilot Will Not Light A gas shut off valve is turned off The gas control knob isn't turned to "PILOT" The valve control knob isn't pushed in The igniter wasn't pressed repeatedly No Prop ...

  • Travis Industries DVS Insert EF II - page 33

    Maintenance 33 © Travis Industries 4060111 100-01175 How this Heater Works This heater was designed with safety as the primary concern. Many of the components inside this heater are for safety purposes. Therefore, only certified gas service technicians should service this heater. What Turns the Main Burners On and Off This heater uses a millivolt ...

  • Travis Industries DVS Insert EF II - page 34

    34 Maintenance © Travis Industries 4060111 100-01175 Wiring Diagram Orange White Piezo Igniter Thermopile Red Thermocouple Copper Co-Axial Wire Red Spark Electrode Pilot Hood On/Off Switch Brown Green Hot (black) Common (white) Ground (green) Power In Molex Connector Ground (attached to stove) White Black Rheostat Black Black White Black Snap Disk ...

  • Travis Industries DVS Insert EF II - page 35

    Safety Label 35 © Travis Industries 4060111 100-01175 Safety Label The safety (listing) label is attached to the operating tag (chained to the heater near the gas control valve). A copy is shown below ...

  • Travis Industries DVS Insert EF II - page 36

    3 6 Limted 7 Year Warranty © Travis Industries 4060111 100-01175 To register your TRAVIS INDUSTRIES, INC. 7 Year Warranty, complete the enclosed Warranty card and mail it within ten (10) days of the appliance purchase date to: TRAVIS INDUSTRIES, INC., 4800 Harbour Pointe Blvd. SW, Mukilteo, WA 98275. TRAVIS INDUSTRIES, INC. warrants this gas appli ...

  • Travis Industries DVS Insert EF II - page 37

    Optional Equipment (for qualified installers only) 37 © Travis Industries 4060111 100-01175 LP Conversion Instructions Install the conversion kit prior to installing the gas line to ensure proper gas use. 1 Remove the glass (see page 21). Remove the logs and coals (if installed - page 23) 2 Remove the burner (see illustration below). WARNING : Do ...

  • Travis Industries DVS Insert EF II - page 38

    38 Optional Equipment (for qualified installers only) © Travis Industries 4060111 100-01175 3 Follow the directions below to replace the orifices. Look here for the orifice identification Apply thread sealant to the LP orifices prior to installation. Use the chart below to identify the correct orifices. LP .0625 NG #37 c Orifice Manifold 1/2" ...

  • Travis Industries DVS Insert EF II - page 39

    Optional Equipment (for qualified installers only) 39 © Travis Industries 4060111 100-01175 5 Install the logs and embers. 6 Replace glass and face. 7 Remove the regulator from the front of the gas control valve. Replace with the propane regulator, using the new gasket and screws included with the regulator. NOTE: Leak test this area after the hea ...

  • Travis Industries DVS Insert EF II - page 40

    40 Optional Equipment (for qualified installers only) © Travis Industries 4060111 100-01175 Firebacks Slide the top of the rear fireback behind the baffle on top of the firebox and pivot it back into place. It rests on the shelf at the back of the firebox. Hold the side firebacks at a slight angle and place them into position (both sides). Remove ...

  • Travis Industries DVS Insert EF II - page 41

    Optional Equipment (for qualified installers only) 41 © Travis Industries 4060111 100-01175 Lower Surround Panel The older lower surround panel (sku 98500619 and 98500628) are installed in a different fashion than illustrated in the instruction sheet included with the panel. Follow the directions below. 1 Prepare the panel following the directions ...

  • Travis Industries DVS Insert EF II - page 42

    42 Index © Travis Industries 4060111 100-01175 Additional Items Required ....................................7 Adjusting the Blower Speed ..................................3 0 Adjusting the Flame Height ..................................2 9 Air Shutter Adjustment ........................................2 5 Altitude Considerations ................. ...

Fabricant Travis Industries Catégorie Indoor Fireplace

Les documents que nous recevons du fabricant de l'appareilTravis Industries DVS Insert EF II peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Travis Industries
- manuels d’utilisations DVS Insert EF II
- fiches produit Travis Industries
- dépliants
- ou étiquettes-énergie Travis Industries DVS Insert EF II
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Travis Industries DVS Insert EF II.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Travis Industries DVS Insert EF II, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Travis Industries DVS Insert EF II. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Travis Industries DVS Insert EF II.

Manuel d’utilisation complet de l’appareil Travis Industries DVS Insert EF II, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Travis Industries DVS Insert EF II par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Travis Industries DVS Insert EF II.

Le manuel d’utilisation complet Travis Industries, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Travis Industries DVS Insert EF II - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Travis Industries DVS Insert EF II, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lTravis Industries DVS Insert EF II qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Travis Industries DVS Insert EF II - qui devraient nous aider dans les premières étapes lors de l'utilisation Travis Industries DVS Insert EF II
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Travis Industries DVS Insert EF II
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Travis Industries DVS Insert EF II dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Travis Industries DVS Insert EF II?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Travis Industries DVS Insert EF II, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Travis Industries DVS Insert EF II il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)