Manuel d’utilisation Westinghouse UL-ES-Parkway-WH10

24 pages 1.12 mb
Télécharger

Aller à la page of 24

Summary
  • Westinghouse UL-ES-Parkway-WH10 - page 1

    UL -ES-Parkwa y-WH10 OWNER' S MANUAL MANUAL DEL USUARIO Please write model number here for future reference: / Por fav or , incluya el número del modelo aquí para futura referencia: Net Weight: 14.08 LBS P es o N et o : 6. 39 K GS P arkw a y ...

  • Westinghouse UL-ES-Parkway-WH10 - page 2

    2 UL -ES-Parkwa y-WH10 1. Installation work and elec trical wiring must be done by qualified person(s) in accordance with all applicable codes and standards (ANSI/NFP A 70-1999), including fire-rated construction. 2. Use this unit only in the manner intended by the manufacturer . If you have any questions contact the manufacturer . 3. After making ...

  • Westinghouse UL-ES-Parkway-WH10 - page 3

    3 UL -ES-Parkwa y-WH10 1. El trabajo de instalación y el cableado eléctrico los deben efec tuar personas calificadas cumpliendo con todos los códigos y las normas aplicables (ANSI/NFP A 70-1999), incluyendo las de incendio. 2. Use esta unidad sólo de la manera en que el fabricante quiere que se haga. Si tiene dudas, llame al fabricante. 3. Desp ...

  • Westinghouse UL-ES-Parkway-WH10 - page 4

    4 UL -ES-Parkwa y-WH10 FEA TURES C ARA C TERÍSTICAS DOWNROD INST ALLA TION INST ALACIÓN CON V ARILLA VERTICAL For normal ceilings Para cielorrasos normales V AUL TED CEILING INST ALLA TION INST ALACIÓN P ARA CIEL ORRASOS ABOVEDADOS May require a longer downrod (sold separately) Podría requerir una varilla vertical más larga (se vende por separ ...

  • Westinghouse UL-ES-Parkway-WH10 - page 5

    5 UL -ES-Parkwa y-WH10 COMBO-BLADE Combo-Blades feature two high quality finishes on one blade. Select the one that best complements your decor , or change the style with just a flip of the blade. NOTE: Combo-Blade finishes var y , depending upon model. ASP AS DE DOBLE CARA Las aspas del rotor de doble cara presentan dos super ficies con un acabado ...

  • Westinghouse UL-ES-Parkway-WH10 - page 6

    6 UL -ES-Parkwa y-WH10 6 Unpack and inspect fan carefully to be certain all conten ts are included. T urn off power at fuse box to avoid possible elec trical shock. 1 Use metal outlet box suitable for fan suppor t (must support 35 lbs). Before attaching fan to outlet box, ensure the outlet box is securely fastened by at least two points to a struct ...

  • Westinghouse UL-ES-Parkway-WH10 - page 7

    7 UL -ES-Parkwa y-WH10 Remove the screws and star washers from the two mating holes (1) on the canopy . Loosen (do not remov e) the screws in the mating slots (2) on the canopy . Rotate the mounting bracket and remove from the canopy . Quite los tornillos y las dos arandelas en estrella de los dos orificios coinciden tes (1) del dosel. Afloje (no q ...

  • Westinghouse UL-ES-Parkway-WH10 - page 8

    8 UL -ES-Parkwa y-WH10 MOUNTING BRA CKET INST ALLA TION INST ALACIÓN CON SOPORTE DE MONT A JE Install mounting brack et to outlet box in ceiling using the screws and washers provided with the outlet box. Instale el soporte de montaje a la caja de embutir del cielorraso con la tornillería suministrada con la caja de embutir . 4 5 MOUNTING OPTIONS ...

  • Westinghouse UL-ES-Parkway-WH10 - page 9

    9 UL -ES-Parkwa y-WH10 FL USH MOUNT OPTION OPCIÓN DE INST AL A CIÓN AL RAS 6 G ui de m ot o r wi r es t h ro u gh t he b as e of t h e c a no p y a s sh o w n a n d a t ta c h ca no p y directly to top of motor housing with flush mount screws and lock washers provided . Tigh ten screws sec ur ely . De s li c e l o s c a bl es d e l m o to r a tr ...

  • Westinghouse UL-ES-Parkway-WH10 - page 10

    10 UL -ES-Parkwa y-WH10 9 Loosen downrod ball (1) fr om downr od (2) by removing set scr ew (3). Afloje la esfera de la varilla vertical (1) de la varilla vertical (2) quitando el tornillo (3). 2 3 1 EX TENDED DOWNROD OPTION OPCIÓN C ON VARILLA VERTIC AL MÁS L ARGA NORMAL DOWNROD OPTION OPCIÓN C ON VARILLA VERTIC AL P ARA CIEL ORRASO NORMAL 8 2 ...

  • Westinghouse UL-ES-Parkway-WH10 - page 11

    11 UL -ES-Parkwa y-WH10 EX TENDED DOWNROD OPTION OPCIÓN C ON VARILLA VERTIC AL MÁS LARGA 10 S li de d o wn r od b al l (1 ) o ff o f d o wn r o d a n d re m ov e p i n ( 2 ). De s li c e l a es f er a de l a v ar il l a v ert ic a l ( 1 ) h a st a se p ar a rl a de l a v ar i ll a v ert ic a l y q u it e el p as a do r (2 ) . 2 1 11 Re-install pi ...

  • Westinghouse UL-ES-Parkway-WH10 - page 12

    12 UL -ES-Parkwa y-WH10 Feed motor lead wires through downrod/canopy assembly and inser t downrod into downrod yok e. Make sure to align hole in downrod with the hole in downrod yoke. Install yoke cross pin (1) through yok e and downrod . Inser t clamp pin (2) into cross pin until it snaps into place. Tigh ten set screws (3) in yok e. P ase los hil ...

  • Westinghouse UL-ES-Parkway-WH10 - page 13

    13 UL -ES-Parkwa y-WH10 MOUNTING MONT A JE 14 W i th b r ac k et h ol d in g fa n as s em bl y , ma k e el ec tr i ca l co n ne ct io n s u s in g th e following step for wiring instruc tions . C o n l a pi e za d e mo n ta j e s u je ta n do e l co n ju n to d el v e n ti la d or , h ag a l as c on e xi on e s el éc tr ic a s de a cu er do a la s ...

  • Westinghouse UL-ES-Parkway-WH10 - page 14

    14 UL -ES-Parkwa y-WH10 WIRING OPTIONS OPCIÓN DE CABLEADO 16 Follo w diagram above to make wiring connec tions for wall contr ol operation. 15 Follo w diagram above to make wiring connec tions for fan pull chain contr ol. PULL CHAIN WIRING OPTION WALL CONTROL WIRING OPTION Sig a las i nstr ucci ones del di agra ma an ter ior pa ra ha cer las co ne ...

  • Westinghouse UL-ES-Parkway-WH10 - page 15

    15 UL -ES-Parkwa y-WH10 SECURE TO CEILING ASEGURE EL VENTILADOR AL CIEL ORRASO 17 1 3 2 The canopy has two mating slots (1) and t wo mating holes (2). P osition both slots on canopy directly under and in line with t wo screws in the mounting bracket (3). Lift the canopy , allowing the two screws and star wahers to slide into the mating slots. Rotat ...

  • Westinghouse UL-ES-Parkway-WH10 - page 16

    16 UL -ES-Parkwa y-WH10 Check the motor for plastic shipping stabilizer tabs (1), and remove them if they are present. Attach blade assembly to motor using the noise -dampening motor gaskets (2) and motor screws provided. Tighten screws securely . NOTE: Some models do not utilize motor gaskets , washers , or stabilizer tabs. V er if iq u e si h ay ...

  • Westinghouse UL-ES-Parkway-WH10 - page 17

    17 UL -ES-Parkwa y-WH10 Attach the switch housing cap using three small screws provided. Conecte la tapa del alojamiento del interrupt or con los tres tornillos pequeños incluidos. Connect the wire plugs from the motor (1) to the wire plugs from the light kit (2), white to white, and black to black. Attach light kit to the switch housing using thr ...

  • Westinghouse UL-ES-Parkway-WH10 - page 18

    18 UL -ES-Parkwa y-WH10 23 6 1 2 3 4 5 Install glass (1) onto light kit and tighten rubber/ metal washer (2) (rubber side facing the glass), and nut (3) onto bottom of glass. Make sure ceiling fan pull chain is threaded through the side hole in the bottom of the glass. Place decorative cap (4) ov er bottom of glass and secure by tightening decorati ...

  • Westinghouse UL-ES-Parkway-WH10 - page 19

    19 UL -ES-Parkwa y-WH10 24 Assemble decorative fob and extension chains from har dware bag to fan pull chains by inser ting end of chain into chain coupling. Confirm chains are held by lightly pulling both chains in coupling . Sujetar las cadenas largas de tiro con las piezas finales correspondien tes, a las cadenas del ventilador , introduciendo e ...

  • Westinghouse UL-ES-Parkway-WH10 - page 20

    20 UL -ES-Parkwa y-WH10 Operation T urn on the power and check operation of fan. T he pull chain controls the fan speeds as follows: 1 pull - high; 2 pulls - medium; 3 pulls - low; 4 pulls - off. Speed settings for warm or cool wea ther depend on factors such as room size, ceiling height, number of fans and so on. The slide switch controls directio ...

  • Westinghouse UL-ES-Parkway-WH10 - page 21

    21 UL -ES-Parkwa y-WH10 Operación Encienda el ventilador y verifique su funcionamiento . La cadenilla de tiro contr ola las velocidades del ventilador de la siguiente manera: 1 jalón – rápida; 2 jalones - mediana; 3 jalones - lenta; 4 jalones - apagado . Las velocidades para clima cálido o frío dependen de fac tores como el tamaño de la hab ...

  • Westinghouse UL-ES-Parkway-WH10 - page 22

    22 UL -ES-Parkwa y-WH10 TROUBLESHOOTING GUIDE If you have difficulty operating your new ceiling fan, it may be the result of incorrect assembly, installation, or wiring. In some cases, these installation errors may be mistaken for defects. If you experience any faults, please check this T rouble Shooting Chart. If a problem cannot be remedied, plea ...

  • Westinghouse UL-ES-Parkway-WH10 - page 23

    23 UL -ES-Parkwa y-WH10 GUÍA P ARA SOLUCIONAR PROBLEMAS Si tiene dificultades para hacer funcionar su nuevo ventilador , podría ser a causa del armado , instalación o cableado incorrectos. En algunos casos, estos errores de instalación podrían ser confundidos con defectos. Si experimenta alguna falla, consulte esta guía para solucionar proble ...

  • Westinghouse UL-ES-Parkway-WH10 - page 24

    UL -ES-Parkwa y-WH10 W estinghouse Lighting Corporation 12401 McNult y Road Philadelphia, P A 19154 U.S.A. W estinghouse Lighting Corporation, a W estinghouse Elec tric Corporation licensee is a register ed trademark of W estinghouse Electric Corporation Made in China © 2010 Westinghouse Lighting Corporation W estinghouse Lighting Corporation 1240 ...

Fabricant Westinghouse Catégorie Fan

Les documents que nous recevons du fabricant de l'appareilWestinghouse UL-ES-Parkway-WH10 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Westinghouse
- manuels d’utilisations UL-ES-Parkway-WH10
- fiches produit Westinghouse
- dépliants
- ou étiquettes-énergie Westinghouse UL-ES-Parkway-WH10
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Westinghouse UL-ES-Parkway-WH10.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Westinghouse UL-ES-Parkway-WH10, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Westinghouse UL-ES-Parkway-WH10. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Westinghouse UL-ES-Parkway-WH10.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Westinghouse UL-ES-Parkway-WH10, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Westinghouse UL-ES-Parkway-WH10 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Westinghouse UL-ES-Parkway-WH10.

Le manuel d’utilisation complet Westinghouse, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Westinghouse UL-ES-Parkway-WH10 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Westinghouse UL-ES-Parkway-WH10, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lWestinghouse UL-ES-Parkway-WH10 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Westinghouse UL-ES-Parkway-WH10 - qui devraient nous aider dans les premières étapes lors de l'utilisation Westinghouse UL-ES-Parkway-WH10
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Westinghouse UL-ES-Parkway-WH10
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Westinghouse UL-ES-Parkway-WH10 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Westinghouse UL-ES-Parkway-WH10?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Westinghouse UL-ES-Parkway-WH10, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Westinghouse UL-ES-Parkway-WH10 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)