Manuel d’utilisation Vector VEC024

16 pages 0.19 mb
Télécharger

Aller à la page of 16

Summary
  • Vector VEC024 - page 1

    VEC024 OWNER’S MANUAL & W ARRANTY INFORMA TION THIS MANUAL CONT AINS IMPORT ANT INFORMA TION REGARDING SAFETY , OPERA TION, MAINTENANCE AND STORAGE OF THIS PRODUCT . BEFORE USE, READ AND UNDERST AND ALL CAUTIONS, W ARNINGS, INSTRUCTIONS AND PRODUCT LABELS, PLUS YOUR VEHICLE’S BA TTERY MANUF ACTURER GUIDELINES. F AILURE TO DO SO COULD RESULT ...

  • Vector VEC024 - page 2

    2 2 IMPOR T ANT SAFETY INSTRUCTIONS To ensure reliable ser vice, your power inverter must be installed and used properly . Please read the installation and operating instructions thoroughly prior to installation and use. Pay particular attention to the W ARNING and CAUTION statements in this manual. The CAUTION statements advise against certain con ...

  • Vector VEC024 - page 3

    3 CONTENTS 1. INTRODUCTION ..........................................................4 2. CONTROLS, INDICA TORS AND CONNECTORS ..................4,5 3. HOW YOUR INVERTER WORKS ..............................................5 3.1 Principal of Operation ......................................................5 3.2 The MaxxSST 400 Output W aveform ...... ...

  • Vector VEC024 - page 4

    4 4 1. INTRODUCTION Y our new V ector MAXX 400 SST inver ter is one in a series of the mostadvanced DC to AC inverters available today . With proper careandappropriate usage, it will give you years of dependable ser vice in your car , truck, RV or boat. The MAXX 400 SST supplies 400 watts of continuous power , with a 800 watt peak, in the form of t ...

  • Vector VEC024 - page 5

    5 FIGURE 1 FIGURE 2 3. HOW YOUR VECTOR INVER TER WORKS The inverter conver ts low voltage DC (direct current) from a batter y or other power source to standard 110 volt AC (alternating current) household power . 3.1 PRINCIPLE OF OPERA TION The inverter conver ts power in two stages. The first stage is a DC-to-DC conversion process that raises the l ...

  • Vector VEC024 - page 6

    3.2 THE MAXX SST 400 W A TT OUTPUT W A VEFORM The AC output waveform of the MAXX 400 SST is known as “modified sine wave”. It is a waveform that has characteristics similar to the sine wave shape of utility power . This type of waveform is suitable for most AC loads, including linear and switching power supplies used in electronic equipment, tr ...

  • Vector VEC024 - page 7

    7 Example: If a load is rated at 400 watts AC, the power source must be able to deliver: 400 divided by 10 = 40 amperes CAUTION: The MAXX 400 SST must be connected only to batteries with a nominal output voltage of 12 volts. The unit will not operate from a 6 volt batter y and will sustain permanent damage if connected to a 24 volt batter y . 4.2 C ...

  • Vector VEC024 - page 8

    8 8 3. Connect the red cable to the red post marked “(+)” on the back of the inverter . Connect the batter y clip to the positive terminal of the batter y . 4. Check to be sure that all connections between batter y clips and terminals are secure. Direct Hardwiring to Power Source: Use #10 A WG wire if the inverter to power source connection is ...

  • Vector VEC024 - page 9

    9 4.3 CONNECTION TO LOAD The MAXX 400 SST is equipped with dual standard North American AC power receptacles. Plug the cord from the equipment you wish to operate into the AC receptacle(s). The green LED indicator lights to indicate that the inverter is functioning. Make sure the combined load requirement of your equipment does not exceed 400 SST w ...

  • Vector VEC024 - page 10

    10 10 air circulation around the unit. Do not place items on or over the inverter during operation. A fan is helpful if the inverter is operating at maximum power outputs for extended periods of time. The unit will shut down if the internal temperature exceeds operating temperatures. The unit will restart after it cools. SAFE - Do not use the inver ...

  • Vector VEC024 - page 11

    11 ever y 2 to 3 hours to recharge the batter y system. This will guard against any unexpected shut-down of the equipment and will ensure that there is always sufficient batter y capacity to star t the vehicle’ s engine. The inverter will sound it’ s alarm when DC voltage drops to 10.6 volt. The inverter may be used whether or not the vehicle? ...

  • Vector VEC024 - page 12

    12 12 recharged. The user should stop operation of the electronic device at this time since the inverter will shut down automatically shor tly thereafter , when the batter y voltage drops to 10 volts. Start your engine to recharge the batter y . If the low voltage alarm sounds when the batter y is fully charged, follow the steps for solving lack of ...

  • Vector VEC024 - page 13

    13 8. TROUBLESHOOTING GUIDE: T ABLE 1 - INVERTER POWER SWITCH TURNED ON TROUBLE/ INDICA TION POSSIBLE CAUSE SUGGESTED REMEDY No AC output – DC input below 10 volts Recharge or replace red LED lit batter y No AC output – Excessive appliance Reduce load-wait for red LED lit load-thermal shutdown inver ter to cool. T urn OFF, then turn ON No AC ou ...

  • Vector VEC024 - page 14

    14 14 9. FUSE REPLACEMENT If external fuses blow , (or breakers trip), then there is a shor t or overload in the DC wiring. Find and fix the problem before replacing the fuses (or resetting the breaker). After fuse replacement, reconnect the inverter . This power inverter is equipped with multiple internal fuses. Nor mally , these fuses will not bl ...

  • Vector VEC024 - page 15

    15 purchaser only , to be free of defects in materials and workmanship for two years from the date of purchase without additional charge. The warranty does not extend to subsequent purchasers or users. V ector Manufacturing, Ltd. will not be responsible for any amount of damage in excess of the retail purchase price of the product under any circums ...

  • Vector VEC024 - page 16

    © 2004 VECTOR MANUF ACTURING, Ltd. FT . LAUDERDALE, FL 33312 MADE IN CHINA VECTOR MANUF ACTURING, LTD ...

Fabricant Vector Catégorie Marine Battery

Les documents que nous recevons du fabricant de l'appareilVector VEC024 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Vector
- manuels d’utilisations VEC024
- fiches produit Vector
- dépliants
- ou étiquettes-énergie Vector VEC024
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Vector VEC024.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Vector VEC024, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Vector VEC024. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Vector VEC024.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Vector VEC024, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Vector VEC024 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Vector VEC024.

Le manuel d’utilisation complet Vector, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Vector VEC024 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Vector VEC024, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lVector VEC024 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Vector VEC024 - qui devraient nous aider dans les premières étapes lors de l'utilisation Vector VEC024
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Vector VEC024
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Vector VEC024 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Vector VEC024?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Vector VEC024, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Vector VEC024 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)