Manuel d’utilisation Broan HRV90H

26 pages 2.85 mb
Télécharger

Aller à la page of 26

Summary
  • Broan HRV90H - page 1

    INST ALLA TION INSTR UCTIONS HR V90H AND ER V90HC RESIDENTIAL USE ONL Y READ AND SA VE THESE INSTR UCTIONS 06010C re v . E Model no.: HR V90HT (HR V with por ts on top) Model no.: HR V90HS (HR V with por ts on sides) Model no.: ER V90HCT (ER V with por ts on top) Model no.: ER V90HCS (ER V with por ts on sides) VB0082 VB0080 VB0079 VB0081 ...

  • Broan HRV90H - page 2

    ABOUT THIS MANU AL Because of the large amount of models cov ered by this pub lication, the illustrations are typical ones. Some details of y our unit may be slightly diff erent than the ones shown. Please take note that this man ual uses the follo wing symbols to emphasize par ticular information: NO TE: Indicates supplementary information needed ...

  • Broan HRV90H - page 3

    1.0 T ECHNICAL D ATA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-6 1.1 A IR D ISTRIBUTION (N ORMAL O PERA TION ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 1.2 A IR D ISTRIBUTION (R ECIRCULA TION OR D EFROST M ODE ...

  • Broan HRV90H - page 4

    HR V ER V 1. TECHNICAL D A T A 1.1 A IR D ISTRIBUTION (N ORMAL O PERA TION ) VF0039 VF0038 HR V ER V 1.2 A IR D ISTRIBUTION (R ECIRCULA TION OR D EFROST M ODE ) VF0036 VF0037 Celcius (°C) -5 to -27 -27 and less F ahrenheit (°F) 23 to -17 -17 and less Defrosting (min.) 9 10 Operation time (min.) between each defrost cycle 23 22 Outside T emperatur ...

  • Broan HRV90H - page 5

    1.4.1 HR V U NITS 1. TECHNICAL D A T A (CONT’D) 1.4 P ERFORMANCE C HARTS V entilation Performance NO TE: A LL SPECIFICA TIONS ARE SUBJECT T O CHANGE WITHOUT NO TICE . SUPPL Y POWER SENSIBLE APP ARENT LA TENT RECOVER Y/ TEMPERA TURE NET AIR FLOW CONSUMED RECOVERY SENSIBLE MOISTURE WATT S EFFICIENCY EFFECTIVENESS TRANSFER 68 82 11 6 11 0 66 65 59 5 ...

  • Broan HRV90H - page 6

    1. TECHNICAL D A T A (CONT’D) 1.5 D IMENSIONS 1.5.1 D IMENSIONS FOR P ORTS ON S IDES U NITS 2½” (64 mm) 12 16 ” (310 mm) 16 ¼” (413 mm) 3 4’ ’ (102 mm) 6’ ’ (152 mm) 22 16 ” (574 mm) 23 ¾” (603 mm) 9 VK0056 19 16 ” (503 mm) 13 4’ ’ (102 mm) 6’ ’ (152 mm) 2” (51 mm) 13¾” (349 mm) 22 16 ” (574 mm) 9 27 16 ” ( ...

  • Broan HRV90H - page 7

    2.3 S IMPLIFIED I NST ALLA TION (C ONNECTION T O A FORCED AIR SYSTEM ) 2. TYPICAL INST ALLA TIONS Installations ma y vary according to the type of unit and the por ts configuration (top or sides). Use the f ollowing illustrations as guidelines to help you decide on ho w the unit will be installed. All the units should be hung from the joists. In e ...

  • Broan HRV90H - page 8

    2. TYPICAL INST ALLA TIONS (CONT’D) The ER V units are created to meet specific requirements related to geographical locations . T ake a look at the map below; the shaded area shows the limits where the ER V unit can be installed. Howe ver , there is no geographical limitation f or installing an HR V unit. NO TE: The ER V unit is designed to assi ...

  • Broan HRV90H - page 9

    - 9 - 3. INST ALLA TION 3 .1 I NSPECT THE C ONTENTS OF THE B OX • Inspect the e xter ior of the unit f or shipping damage. Ensure that there is no damage to the door , door latches, power cord, etc . • Remov e and discard the 2 transpor t brac kets ( A ) and open the door . Discard the styrofoam fillers (ER V units only) and remov e the hardwar ...

  • Broan HRV90H - page 10

    - 10 - 3. INST ALLA TION (CONT’D) 3.5 P LANNING OF THE D UCTWORK • K eep it simple. Plan f or a minimum of bends and joints. • K eep the length of insulated ducts to a minimum. • Do not ventilate cr awl spaces or cold rooms. Do not attempt to recov er the exhaust air from a dryer or a range hood. This would cause clogging of the filters and ...

  • Broan HRV90H - page 11

    3. INST ALLA TION (CONT’D) 3.6 I NST ALLING THE D UCTW ORK AND R EGISTERS ( CONT ’ D ) 3.6.2 C ENTRAL D RA W P OINT S YSTEM ( AS ILLUSTRA TED IN S ECTION 2.2) Stale air exhaust ductw ork Same as f or Fully Ducted System, descr ibed on point 3.6.1. Fresh air distribution ductw ork There are 2 methods f or connecting the unit to the fur nace/air ...

  • Broan HRV90H - page 12

    3.6 I NST ALLING THE D UCTW ORK AND R EGISTERS ( CONT ’ D ) 3.6.3 S IMPLIFIED I NST ALLA TION ( AS ILLUSTRA TED IN S ECTION 2.3) There are 2 methods f or connecting the unit to the fur nace/air handler : Method 1: Supply-return connection Method 2A: Return-return without Method 2B: Return-return with A utomatic fresh air bypass A utomatic fresh a ...

  • Broan HRV90H - page 13

    Rigid ducts Use a small length of fle xible duct to connect the rigid duct to the por ts in order to av oid vibration transmissions. Use tie-wraps to perf or m connections. 3.7 C ONNECTING THE DUCTS TO THE UNIT Insulated flexible ducts Use the f ollowing procedure f or connecting the insulated flexib le ducts to the por t of the unit ( Exhaust air ...

  • Broan HRV90H - page 14

    3.8 I NST ALLING THE T ANDEM ® T RANSITION K IT ( CONT ’ D ) 3.8.1 C ONNECTION T O T ANDEM ® TRANSITION 1. F or each duct, pull back the insulation to e xpose the interior flexible duct. 2. Connect the interior flexib le duct to the smaller par t of the T andem® transition (5’ ’ ov al) using a tie wrap . 3. Pull the insulation ov er the jo ...

  • Broan HRV90H - page 15

    3.8 I NST ALLING THE T ANDEM ® T RANSITION K IT ( CONT ’ D ) 3.8.4 C ONNECTING T ANDEM ® TRANSITION TO THE D UAL EXTERIOR H OOD ( CONT ’ D ) 2. Join the end of the T andem® transition to the rear of the exterior backplate . Secure with 2 Xmas tree pins and seal properly with duct tape. 3. Using 4 #8 x 1 1 ¼ 2 ” screws , mount the the exte ...

  • Broan HRV90H - page 16

    3. INST ALLA TION (CONT’D) 3.9 I NST ALLING 2 E XTERIOR H OODS Choose an appropriate location to install the exterior hoods: • There must be a minimum distance of 6 f eet (1.8 m) between the hoods to a void cross-contamination • There must be a minimum distance of 18 inches (457 mm) from the g round Make sure the intak e hood is at least 6 fe ...

  • Broan HRV90H - page 17

    4. CONTROLS 4.1 I NTEGRA TED C ONTROL All units are equipped with an integrated control, located under the unit, in front of the electrical compar tment. Use the push button ( 1 ) to control the unit. The LED ( 2 ) will then shows on which mode the unit is in. W ARNING Risk of electric shock. Before perf orming any maintenance or servicing, always ...

  • Broan HRV90H - page 18

    4. CONTROLS (CONT’D) 4.2.1 E LECTRICAL C ONNECTION T O VT4W M AIN W ALL C ONTROL NO C NC I OC OL Y R G B B G OC MAIN WALL CONTROL LITE-TOUCH BRONZE and SIMPLE TOUCH BRONZE REAR VIEW G B Y VE0101A M AIN W ALL CONTROL VT4W REAR VIEW 4.2 E LECTRICAL C ONNECTION T O O PTIONAL W ALL C ONTROLS ( CONT ’ D ) 4.2.2 E LECTRICAL C ONNECTION T O O PTIONAL ...

  • Broan HRV90H - page 19

    4. CONTROLS (CONT’D) 4.4 O PTIONAL A UXILIAR Y W ALL C ONTROLS O PERA TION 4.4.1 20-M INUTE L IGHTED P USH -B UTT ON T IMER Set the push-button timer to ON. The fan motors will then operate at high speed f or 20 minutes and the indicator will light up . T o stop activ ation, push one time; the unit will then get back to previous selection. 4.4.2 ...

  • Broan HRV90H - page 20

    6. WIRING DIA GRAM W ARNING Risk of electrical shocks. Before performing an y maintenance or servicing, al ways disconnect the unit fr om its power source. ! Field wiring remote control (see notes 3 & 4) 120 V, 60 Hz W1 J5 J7 J6 J4 ELECTRONIC ASSEMBLY 1 2 3 1 2 1 2 1 2 3 1 2 3 4 1 2 1 2 3 4 5 1 2 3 4 5 J8 J9 J11 J10 1 2 J12 J13 J14 10 9 8 7 6 5 ...

  • Broan HRV90H - page 21

    7.1 W HA T Y OU N EED T O B ALANCE THE U NIT • A magnehelic gauge capable of measuring 0 to 0.5 inch of water (0 to 125 P a) and 2 plastic tubes. • The balancing char t located on the unit door . 7.2 P RELIMINAR Y S T AGES T O B ALANCE THE U NIT • Seal all the unit ductwork with tape. Close all windows and doors . • T urn off all exhaust de ...

  • Broan HRV90H - page 22

    8. CONNECTING THE DRAIN (HR V UNITS ONL Y) VO0091 VO0093 VO0092 T o drain In order to keep the dr ain pan intact, hand tighten the 2 plastic drain fittings to the unit door using the gaskets and n uts as shown. Cut 2 sections of plastic tubing, about 12” (305 mm) long and attach them to each drain fitting. Join the 2 shor t sections to the «T» ...

  • Broan HRV90H - page 23

    3. Lift both f oam filters brack et ( 1 ) and remov e the f oam filters from the core. While holding the core, rotate the 2 core retainers ( 2 ) and slide out the core from the unit. 2. Unlatch the door and open it. Clean the inner side of the door with a damp cloth, then wipe with a dr y one. Disengage the door from its hinge by sliding it from le ...

  • Broan HRV90H - page 24

    9. MAINTENANCE (CONT’D) 9.1 S EMI -A NNU AL M AINTENANCE ( CONT ’ D ) 4. Clean the inside walls of the unit with a clean damp cloth, then wipe with a clean dry one. 5. W ash the 2 core filters under hot water with mild soap . Rinse thoroughly and let dr y completely bef ore reinstalling on the core. 6. Remov e the dust on the core using a vacuu ...

  • Broan HRV90H - page 25

    - 25 - VL0019 10. SER VICE P ARTS I TEM D ESCRIPTION P ART N UMBER HR V90HS HR V90HT ER V90HCS ER V90HCT ( PORTS ON SIDES )( PORTS ON TOP )( PORTS ON SIDES )( PORTS ON T OP ) 1O V AL PORT ( FITS 5” DIAMETER DUCTS ) 16040 1 1 1 1 2D OOR LA TCH WITH SCREWS 16035 2 2 2 2 3O V AL PORT WITH INTEGRA TED BALANCING DAMPER 16041 2 2 2 2 4M OTO R & WHE ...

  • Broan HRV90H - page 26

    11. TROUBLESHOO TING Prob lems P ossible causes Y ou should try this 1. Unit does not work. • The circuit board may be def ective. • Unplug the unit. Disconnect the main control and the auxiliary control(s) (if need be). Jump G and B terminals. Plug the unit b a c k and w ait about 10 seconds. If the motors r un on high speed and the damper ope ...

Fabricant Broan Catégorie Air Cleaner

Les documents que nous recevons du fabricant de l'appareilBroan HRV90H peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Broan
- manuels d’utilisations HRV90H
- fiches produit Broan
- dépliants
- ou étiquettes-énergie Broan HRV90H
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Broan HRV90H.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Broan HRV90H, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Broan HRV90H. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Broan HRV90H.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Broan HRV90H, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Broan HRV90H par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Broan HRV90H.

Le manuel d’utilisation complet Broan, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Broan HRV90H - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Broan HRV90H, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lBroan HRV90H qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Broan HRV90H - qui devraient nous aider dans les premières étapes lors de l'utilisation Broan HRV90H
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Broan HRV90H
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Broan HRV90H dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Broan HRV90H?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Broan HRV90H, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Broan HRV90H il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)