    R e v e r e Fireplace Insert Owner's Manual • Masonry Fireplace Insert • Zero-Clearance (Metal) Fireplace Insert Save these instructions for future reference S A FE TY N OTIC E : If thi s appl i anc e is not properly ins tal l ed, a house fi re may re sult. For y our s afe ty, fol low the i nstall ation d i r ecti on s. C ontac t l ocal bu ...

  • Lopi Revere - page 2

    2 Introduction © Travis Industries 100-01165 4040806 Introduction We welcome you as a new owner of a Lopi Revere wood-burning fireplace insert. In purchasing a Lopi Revere you have joined the growing ranks of concerned individuals whose selection of an energy system reflects both a concern for the environment and aesthetics. The Lopi Revere is one ...

  • Lopi Revere - page 3

    Table of Contents 3 © Travis Industries 100-01165 4040806 General Information Introduction ...................................................... 2 Important Information ......................................... 2 Safety Precautions ............................................. 4 Features & Specifications .................................... 6 ...

  • Lopi Revere - page 4

    4 Safety Precautions © Travis Industries 100-01165 4040806 The viewing door must be closed and latched during operation. Never block free airflow through the air vents on this appliance. Gas Gasoline or other flammable liquids must never be used to start the fire or "Freshen Up" the fire. Do not store or use gasoline or other flammable l ...

  • Lopi Revere - page 5

    Safety Precautions 5 © Travis Industries 100-01165 4040806 Mobile Home When installed in a mobile home, this appliance must be bolted to the floor, have outside air, and not be installed in the bedroom (Per H.U.D. requirements). Check with local building officials. Do not place clothing or other flammable items on or near this appliance. Never try ...

  • Lopi Revere - page 6

    6 Fe atures & Specifications © Travis Industries 100-01165 4040806 Installation Options: • Masonry Fireplace Insert • Zero-Clearance (Metal) Fireplace Insert Features: • EPA Phase II Approved • 2.2 Cubic Foot Firebox Volume • Single Operating Control • Accepts Logs Up to 18" Long • Steel Plate Construction (5/16" & ...

  • Lopi Revere - page 7

    Stove Installation (for qualified installers only) 7 © Travis Industries 100-01165 4040806 SAFETY NOTICE: P lease r ead th is en tir e m an u al b efo r e you inst all an d u se yo ur n ew r o o m h eater . F ailu r e to f o llo w in st r u c tio n s m ay r es u lt in p r o p e r t y d am ag e, bo d il y inju r y, o r even death . C ontac t l oca ...

  • Lopi Revere - page 8

    8 Stove Installation (for qualified installers only) © Travis Industries 100-01165 4040806 Fireplace Requirements Figure 2 shows the minimum size requirements for the type of fireplace used. a c e f Masonry Fireplace Z.C. (Metal) Fireplace Minimum Fireplace Size a b c d e f g h i j Height (front) Height (rear) Width (front) Width (rear) Depth Hear ...

  • Lopi Revere - page 9

    Stove Installation (for qualified installers only) 9 © Travis Industries 100-01165 4040806 Insert Placement Requirements • The insert must be placed so that no combustibles are within, or can swing within (e.g. drapes, doors), 36" of the front of the insert • Insert and hearth must be installed on a level, secure floor • The minimum cle ...

  • Lopi Revere - page 10

    10 Stove Installation (for qualified installers only) © Travis Industries 100-01165 4040806 Zero-Clearance (Metal) Fireplace Requirements • Must utilize a positive (full reline) or direct connection (block-off plate) • Must be manufactured by one of the following manufacturers: • Marco • Majestic • Heatilator • Preway • Tempco • Su ...

  • Lopi Revere - page 11

    Stove Installation (for qualified installers only) 11 © Travis Industries 100-01165 4040806 Block-Off Plate Installation Whenever this appliance is installed with a direct connection a block-off plate, or other non-combustible seal-off device (e.g. damper adapter), will need to be installed. This device is used to seal the chimney, insuring no smo ...

  • Lopi Revere - page 12

    12 Stove Installation (for qualified installers only) © Travis Industries 100-01165 4040806 Insert with Positive Connection NOTE : Most factory-built chimney manufacturers make stainless steel chimney liners, either flexible or rigid. This provides a wide variety of installation options. Make sure to follow the manufacturer's instructions for ...

  • Lopi Revere - page 13

    Stove Installation (for qualified installers only) 13 © Travis Industries 100-01165 4040806 Insert with Direct Connection (Z.C. Fireplace) NOTE : Direct connections require installation of an airtight block-off plate or damper adapter (see "Block-off Plate Installation" on page 11). Block-off plate or damper adapter Stainless steel chimn ...

  • Lopi Revere - page 14

    14 Operating Your Appliance © Travis Industries 100-01165 4040806 Safety Notice: If this appliance is not properly installed, a house fire may result. For your safety, follow the installation directions. Contact local building or fire officials about restrictions and installation inspection requirements in your area. Read and follow all of the war ...

  • Lopi Revere - page 15

    Operating Your Appliance 15 © Travis Industries 100-01165 4040806 Bypass Operation The bypass controls the flow of smoke inside the heater. When pulled out, smoke goes directly up the flue, creating more draft. When pushed in, the smoke goes around the baffle, utilizing the secondary combustion and making the heater more efficient. • When starti ...

  • Lopi Revere - page 16

    16 Operating Your Appliance © Travis Industries 100-01165 4040806 Starting a Fire Since the dawn of time man has debated the best way to start a fire. Some use the boy-scout "tee-pee", some prefer the "tic-tac-toe" stack. Either way, review the hints and warnings below to ensure proper fire starting. • Make sure the air contr ...

  • Lopi Revere - page 17

    Operating Your Appliance 17 © Travis Industries 100-01165 4040806 Adjusting the Burn Rate Use the air control slider to control the burn rate of the stove. See the illustration below for details. Low Burn (air control closed) High Burn (air control open) Use the air control to change the burn rate. Approximate Air Control Settings: Overnight Burn ...

  • Lopi Revere - page 18

    18 Operating Your Appliance © Travis Industries 100-01165 4040806 Optional Blower Operation The blower will turn on once the stove is up to temperature. This is typically 15 to 30 minutes after starting the fire. Follow the directions below to alter the blower speed. OFF Turn the dial all the way counter- clockwise until it clicks off. BLOWER CONT ...

  • Lopi Revere - page 19

    Operating Your Appliance 19 © Travis Industries 100-01165 4040806 Hints for Burning • Get the appliance hot before adjusting to low burn • Use smaller pieces of wood during start-up and high burns to increase temperature • Use larger pieces of wood for overnight or sustained burns • Stack the wood tightly together to establish a longer bur ...

  • Lopi Revere - page 20

    20 Operating Your Appliance © Travis Industries 100-01165 4040806 Troubleshooting Problem Possible Cause Smoke Enters Room During Start-Up • Open the bypass (pg. 15). • Open the air control (pg. 17). • Cold Air Blockage - burn a piece of newspaper to establish a draft. • If the flame is not getting enough air, a small crack in the door is ...

  • Lopi Revere - page 21

    Maintaining Your Appliance 21 © Travis Industries 100-01165 4040806 Failure to properly maintain and inspect your appliance may reduce the performance and life of the appliance, void your warranty, and create a fire hazard. Daily Maintenance (while stove is in use) Remove Ash (if necessary) • Ash removal is not required once it builds up. 1/2&qu ...

  • Lopi Revere - page 22

    22 Maintaining Your Appliance © Travis Industries 100-01165 4040806 Monthly Maintenance (while appliance is in use) Make sure the appliance has fully cooled prior to conducting service. Door and Glass Inspection The door must form an air-tight seal to the firebox for the stove to work correctly. Inspect the door gasket to make sure it forms an air ...

  • Lopi Revere - page 23

    Maintaining Your Appliance 23 © Travis Industries 100-01165 4040806 Yearly Maintenance Make sure the appliance has fully cooled prior to conducting service. Touch Up Paint Included with the owner's pack of this appliance is a can of Stove-Brite® paint. To touch up nicks or dulled paint, apply the paint while the appliance is cool. Sand ruste ...

  • Lopi Revere - page 24

    24 Maintaining Your Appliance © Travis Industries 100-01165 4040806 Door Parts 9/16" Wrench 5 10 8 9 12 7 6 3 4 1 2 11 NOTE : Place the glass gasket around the perimeter of the door retainer. NOTE : Glue the door gasket to the door retainer. # 20 Torx Driver 13 14 1/8 ” Hex Wrench ID # Description Qty Part # ID # Description Qty Part # 1 Do ...

  • Lopi Revere - page 25

    Maintaining Your Appliance 25 © Travis Industries 100-01165 4040806 Firebox Parts 1 3 4 2 6 7 5 9 8 11 11 11 11 10 13 12 11 11 14 11 11 11 11 11 ID # Description Qty Part # ID # Description Qty Part # 1 Air Tubes & Sleeve 1 98900233 2 Air Tube Roll Pins 6 98900357 3 Air Tube Retainer Sleeve 3 98900356 4 Baffle Support, Front 1 99900251 5 Baffl ...

  • Lopi Revere - page 26

    26 Maintaining Your Appliance © Travis Industries 100-01165 4040806 Baffle Removal & Replacement 1 Push the front firebricks up and feed them forward, guiding them out the door. Repeat for the rear firebricks. Baffle Firebrick Front Baffle Support Center Baffle Support Bypass Support Front Air Tube Support Tabs Bypass Damper Bypass Rod (& ...

  • Lopi Revere - page 27

    Limited 7 Year Warrant y 27 © Travis Industries 100-01165 4040806 To register your TRAVIS INDUSTRIES, INC. 7 Year Warranty, complete the enclosed warranty card and mail it within ten (10) days of the appliance purchase date to: TRAVIS INDUSTRIES, INC., 4800 Harbour Pointe Blvd. SW, Mukilteo, WA 98275. TRAVIS INDUSTRIES, INC. warrants this gas appl ...

  • Lopi Revere - page 28

    28 Listing Label © Travis Industries 100-01165 4040806 Listing Label CONTACT YOUR LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION IN YOUR AREA MODEL: LOPI ® REVERE (X-NT) Report No. 028-S-44-4 SERIAL NO: Listed Fireplace Insert for installation into a Factory-Built (Z.C.) fireplace or masonry fireplace WARNING - DO ...

  • Lopi Revere - page 29

    Optional Equipment 29 © Travis Industries 100-01165 4040806 Door Shell Installation Part Numbers: Black # 99300195, Brass # 9930096, Pewter # 99300197 1 Remove the door retainer shipping latch following the directions below. Standard Screwdriver Rotate this shaft 1/4 turn clockwise until the door unlatches. Swing the door retianer open. Remove and ...

  • Lopi Revere - page 30

    30 Optional Equipment © Travis Industries 100-01165 4040806 3 Attach the retainer to the shell following the directions below. Make sure the door retainer is centered on the door shell. You can gauge the alignment by looking at the gaps here. Once the door is aligned, tighten the two set screws on the bottom of the door shell to secure the door re ...

  • Lopi Revere - page 31

    Optional Equipment 31 © Travis Industries 100-01165 4040806 Surround Panels Rectangular Panels: SURROUND PANEL SIZE HEIGHT WIDTH 8 " 27 5/8 " 40 3/8 " 10 " 29 5/8 " 44 3/8 " 12 " 31 5/8 " 48 3/8 " Arched Panels (Part # 99300109) 40-1/4 ” 32-1/4 ” 24-1/2 ” Radius = 40-3/4 ” 28-3/4 ” 23-1/4 ” ...

  • Lopi Revere - page 32

    32 Optional Equipment © Travis Industries 100-01165 4040806 2. Adjust the position of the side panels so they are: 1) flush with the bottom of the insert; 2) both the same distance back from the front of the insert; 3) perpendicular to the floor (use the top panel, if necessary, to judge alignment). Tighten the screws that hold the side panels in ...

  • Lopi Revere - page 33

    Optional Equipment 33 © Travis Industries 100-01165 4040806 Front Blower (part # 99000133) To Switch The Power Cord To The Left Side: Use a pair of pliers to disconnect the strain relief which holds the power cord in place. With the power cord slackened, the molex connectors that attach the power cord to the blower assembly may be disconnected. Pr ...

  • Lopi Revere - page 34

    34 Index © Travis Industries 100-01165 4040806 Air Control (Burn Rate) ...................................1 7 Air Tube Part Number ....................................2 5 Air Tube Removal & Replacement ....................2 6 Ash Disposal ................................................2 1 Baffle Parts ......................................... ...

Fabricant Lopi Catégorie Indoor Fireplace

Les documents que nous recevons du fabricant de l'appareilLopi Revere peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Lopi
- manuels d’utilisations Revere
- fiches produit Lopi
- dépliants
- ou étiquettes-énergie Lopi Revere
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Lopi Revere.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Lopi Revere, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Lopi Revere. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Lopi Revere.

Manuel d’utilisation complet de l’appareil Lopi Revere, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Lopi Revere par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Lopi Revere.

Le manuel d’utilisation complet Lopi, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Lopi Revere - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Lopi Revere, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lLopi Revere qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Lopi Revere - qui devraient nous aider dans les premières étapes lors de l'utilisation Lopi Revere
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Lopi Revere
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Lopi Revere dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Lopi Revere?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Lopi Revere, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Lopi Revere il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)