  • Aiphone LEF-3L - page 1

    – 1 – - SUPPLEMENT TO LEF INSTRUCTIONS - The LEF-3L is a compact, wall or desk mount master station able to selectively release a door or call up a camera. Used with any LE-(except LEF-3,5 and 10) or LS-series (North America only) remote station, communication can be established with each station by selecting the channel on the master station. ...

  • Aiphone LEF-3L - page 2

    – 2 – Wire Refer ence Chart (North America only) Standard Communication With selective door release and/ or camera call-up Model # # of Conductors Wire # (22A WG) Wire # (18A WG) # of Conductors Wire # (22A WG) LEF-3L 9 822210 x 12 822212 LE-A 3 822203 821803 x x LE-D 3 822203 821803 x x LE-D A 3 822203 821803 x x 1 NAMES & FEA TURES FEA ...

  • Aiphone LEF-3L - page 3

    – 3 – 2 SYSTEM OUTLINE & COMPONENTS ■ System outline Individual Components for LEF-3L System: * : North America only *LS-NVP/C   Va ndal and weather resistant sub station, white powder coated (optional SBX-NVP surface box) *LE-SS    Stainless Steel 2-Gang sub station *LE-SSR    Stainless Steel 2-Gang sub station with red mushr o ...

  • Aiphone LEF-3L - page 4

    – 4 – 2 SYSTEM OUTLINE & COMPONENTS (Cont.) LE-D/LE-DA TERMINAL DEFINITIONS: 1  Station number E  Common communication −  Negative *LS-NVP/C TERMINAL DEFINITIONS: Red Station number Black Common communication Green Negative *LE-SS(R)/LE-SS-1G COLOR CODE: Red   Station number Black   Common communication Green   Negative * ...

  • Aiphone LEF-3L - page 5

    – 5 – Wire: · Shielded wire is str ongly recommended. Use the proper gauge for the distance being run. · Wiring between masters must be a multi-conductor cable. If more than one cable is used to connect masters, the "E", "C", and number terminal wires must be in the same jacketed cable. If necessary , run multiple "E& ...

  • Aiphone LEF-3L - page 6

    – 6 – 2 SYSTEM OUTLINE & COMPONENTS (Cont.) ■ Call tone adjustment 3-position volume switch, located under Operation plate. Adjusts call tone volume to low (far left), medium, high (far right). ■ Selector switch for Call T one in Occupied Mode LEF surface mount master stations are set in the "B" position fr om the factory . Th ...

  • Aiphone LEF-3L - page 7

    – 7 – 3 MOUNTING LEF-3L intercom SINGLE-GANG BOX 83.5mm, 3-5/16" 2 screws supplied Chassis Loosen Operation plate Directory card ★ 2 ★ 1 UP 83.5mm, 3-5/16" SINFGLE-GANG BOX Mounting bracket 2 screws supplied (LE-A) Unplug while installing OFF OCCUPIED VOL. VOICE TALK AIPHONE LEF-3L 12 3 Station- selector (3) Station Call-in LE ...

  • Aiphone LEF-3L - page 8

    – 8 – 4 WIRING DIAGRAMS - Most Common Applications 1 x LEF-3L, 3 x Door Stations WIth Selective Door Release 2 x LEF-3L, 2 x Door Stations With Master to Master communication shown on channel 3 With Selective Door Release 2 x LEF-3L, 1 x Door Station With Master to Master Communication Door Station wired on each station's own number termin ...

  • Aiphone LEF-3L - page 9

    – 9 – 4 WIRING DIAGRAMS - Multiple Masters for Door Answering LEF-3L System with External Signaling (RY -AC) One door station with the ability to activate a separate doorbell Shown with external signaling and door release relays LEF-3L System with External Signaling (RY -AC) Selective external signaling relay outputs for each door station call- ...

  • Aiphone LEF-3L - page 10

    – 10 – 5 OPERA TIONS & SPECIFICA TIONS OPERA TIONS: ■ Calling a master or sub: 1. Depress a station selector button 1 ~ 3. 2. Press the T ALK button to speak, and release to listen to the reply . 3. T o conclude, depress OFF button. ■ Receiving a call from a sub station: 1. Sub station calls in with tone and LED, which stays lit for 20 ...

  • Aiphone LEF-3L - page 11

    – 11 – WIRING DIST ANCE: Dimensions (HxWxD): 180H x 143W x 53.5D (mm). 7-1/16" x 5-5/8" x 2-1/8" RY -P A Contact Rating: 1A, 110V AC or 24V DC RESTRICTIONS · Only one power supply can be used on one system. · Up to 4 masters can be connected on the multiple masters confi guration, or up to 3 masters on the intermix confi gura ...

  • Aiphone LEF-3L - page 12

    – 12 – 6 TROUBLESHOOTING GUIDE (Cont.) ENTRY # PROBLEM POSSIBLE CAUSE SOLUTION 5 No master -to-master communication. C terminals mis-wired between masters. Communication between masters is carried on the # wire of the calling master to the C terminal of the receiving master . Verify that the C terminal of the master that is being called is actu ...

Fabricant Aiphone Catégorie Safety Gate

Les documents que nous recevons du fabricant de l'appareilAiphone LEF-3L peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Aiphone
- manuels d’utilisations LEF-3L
- fiches produit Aiphone
- dépliants
- ou étiquettes-énergie Aiphone LEF-3L
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Aiphone LEF-3L.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Aiphone LEF-3L, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Aiphone LEF-3L. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Aiphone LEF-3L.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Aiphone LEF-3L, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Aiphone LEF-3L par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Aiphone LEF-3L.

Le manuel d’utilisation complet Aiphone, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Aiphone LEF-3L - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Aiphone LEF-3L, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lAiphone LEF-3L qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Aiphone LEF-3L - qui devraient nous aider dans les premières étapes lors de l'utilisation Aiphone LEF-3L
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Aiphone LEF-3L
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Aiphone LEF-3L dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Aiphone LEF-3L?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Aiphone LEF-3L, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Aiphone LEF-3L il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)