Manuel d’utilisation IMC Networks E1

24 pages 0.53 mb
Télécharger

Aller à la page of 24

Summary
  • IMC Networks E1 - page 1

    IE-iMcV-T1/E1/J1-LineTerm SFP and 1x9 Operation Manual Above illustration is representati ve; different m odels av ailable ...

  • IMC Networks E1 - page 2

    ii FCC Radio Frequency Inter ference Sta tement This equipment has been tested and found to comply wi th the limi ts fo r a Cla ss A c omput ing d evic e, pursu ant t o Pa rt 15 of the F CC Rules. These limits are designed to pr ovide reasonable protection against harmful interference when the equipment is o perated in a com mercial environment. Th ...

  • IMC Networks E1 - page 3

    iii Table of Cont ents FCC Radio Fre quency Interfe rence Stateme nt .................................................... ii Warranty ............ ................................................................. ............................... ii About the IE-iM cV-T1/E1/J1-LineTerm . ............................................................... ...

  • IMC Networks E1 - page 4

    1 Abou t the IE -iM cV-T1/E 1/J1 -Line Term, TP/ SFP IE-iMcV-T1/ E1/J1-Line Term, TP/S FP is an SNMP -Manageable m odule that c onverts standard TD M -based c opper transp orts ( T1, E1 , J1) to a single -mode or mul ti-mode fiber signal. It performs a standard “L ine Termination ” function as define d in GR - 820-CORE. This fun ction tran smit ...

  • IMC Networks E1 - page 5

    2 NOTE IE-iMcV- T1/E1/J1-L ineTer m, TP/SFP with SFP Module can be installed in an iMed iaChassis and MediaChas sis series. Installing an iMcV-Module iMcV-Modules install in IMC Ne tworks’ SNMP manageable iM ediaChassis series or in any MediaCha ssis/IE-Me diaChassis series. To install an iM cV-Module: 1. Remov e the blank b racket cov ering th e ...

  • IMC Networks E1 - page 6

    3 • Required CSU line Buildout (0db t o -22db) • Receiver BOOS T for T1 an d E1 applica tions • Fibe r tra nsceive rs mu st be fo r approp riate fiber r un, i .e. (SM or MM) • Management location must be at HOST unit Managed Modules The IE-iMcV-T1/E1/J1-LineTerm, TP/S FP modules are installed as a HOST-REMOTE pair and can be remotely man ag ...

  • IMC Networks E1 - page 7

    4 Conf igur ation Cont rol Some iMcV -Modules offer confi guration c ontrol; lab els on the fr ont faceplate a re identified as such. Configuration control has been implemented to assi st the end user by retaining the latest confi guration re gardle ss of ho w that con figurati on was implemented (via DIP S witch settings or S NMP). Historically, S ...

  • IMC Networks E1 - page 8

    5 NOTE If the end user has a mixture of standard iM cV-Modules as well as Configura tion Control iMcV-Modules, it is important to understand how SNMP and DIP Switches will impact the cards depending on their capa bility. Sta nda rd iMcV-Modul es cannot be upgrade d to Config ur atio n Co ntrol cap abilit y, s o it is str o ngly recomme nded to set ...

  • IMC Networks E1 - page 9

    6 DIP Switches The IE-iMcV-T1/E1/J1 -LineTerm, TP /SFP DI P Switches are locate d on S2 an d S3 on the PCB. T he loca tion of the S2 a nd S3 DIP Switches are displayed in the following diag ram : ...

  • IMC Networks E1 - page 10

    7 DIP Sw it ch S et ting s (S2 , S3) Switch Sett ings for Switch S2 T1/E1 Selec tion S2-1: OFF T1 Mode Selected default S2-1: O N E1 Mode Sele cted Receive Equaliz er Gain Limit (EGL) E1 iVIE W 2 S2-2: ON -12 dB (Short Haul) iVIE W 2 S2-2: OFF -43 dB (Long Haul) iVIE W 2 T1 iVIE W 2 S2-2: ON -36 dB (Long Haul) iVIE W 2 S2-2: OFF -30 dB (Limited Lon ...

  • IMC Networks E1 - page 11

    8 Switch Sett ings for Sw itch S3 Rese rve d S3-1: ON Reserved S3-1: OFF Reserved def ault Remo te Mana gemen t S3-2: ON Remote Management Enabled (only at the REMOTE end) S3-2: OF F Remote Ma nagement Disab led (onl y at th e LOCAL end) default Loopback Selection iVIEW 2 S3-3: ON S3-4: ON None iVIE W 2 default S3-3: OFF S3-4: ON Fiber Analog Loopb ...

  • IMC Networks E1 - page 12

    9 Featu re s The IE-iMcV-T1/E1/J1-LineTerm, TP/S FP module includes sever al feature s to facilitate maintenance and troubleshooting in an y T1/E1/J1 based TDM environment. SFP SFPs wit h Data and Diagn ostics Management Information (DD MI) can be in stalle d in the SFP port of the h ost and the remot e. Th is allows the end user to vie w the DDMI ...

  • IMC Networks E1 - page 13

    10 Loopback Modes This feature allows thre e distinct Loopba cks to be activated eit her through DIP Switches or iView 2 Management. Fiber Loopback An ana log Loopb ack at th e copper po rt back to t he fib er por t. It copies the received optical signal back to the optical line at t he copper port and c ontinu es to driv e the copper p ort, but ca ...

  • IMC Networks E1 - page 14

    11 Fault Loopback This switch enables or disables the Fault Loopback feature on the copper port. A normal copper line LOS fault will cause a Rem ote Alarm Indict or (RAI) to be sent on to the fiber line segment causing the n ormal AIS to be sent on the far en d copper port. The fau lt loop back fe ature provi des fo r a fault indica tion to be sent ...

  • IMC Networks E1 - page 15

    12 T1, E1 and J1 Selecti on This switch selects the data r ate to use on the copper line. The data rate selections available include the following: • T1/J1 (1.544 Mbps +/- 32 ppm) • E1 (2.04 8 Mbps +/- 32 ppm) By def ault this feature is set to T1. This feature can be selected onl y by setting the DIP S witches manually. Remote Management A DIP ...

  • IMC Networks E1 - page 16

    13 LED Operation The IE-iMcV-T1/E1/J1-LineTerm, TP/S FP module features seve ral diagnostic LEDs per port. The following L ED display function s are provid ed: Copper P ort LEDs ER Flashes yellow whe never a line code violation is received. LOS Glows red whe n the R J-48 is receiving n o signal and is in an LOS ALARM state. This condition will also ...

  • IMC Networks E1 - page 17

    14 Loopback Tes ting The IE-iMcV-T1 /E1/J1-LineTerm , TP/SFP incl udes three Loopback test m odes: Copper Loopback, Fibe r Loopback and I nternal Fiber Loopback. The follow ing illustrations show a typical prog ression of Loopback tests (i.e., starting by checking the copper segment at the l o cal side, then the fiber segment at the REMOTE side, et ...

  • IMC Networks E1 - page 18

    15 Pseud orandom Bit Sequence (PRB S) Testing To test usin g PRBS, con figure the IE-i McV- T1/ E1/J1 -LineTerm, TP/SFP m odules for No Loopback , and then confi gure th e Transmit Copper Dat a Source to P RBS. Config ure the lo cal device f or Loop back and st art the te st. Verif y the PRBS L ED is ON indicatin g no errors are being r eceive d. I ...

  • IMC Networks E1 - page 19

    16 Use the following LED in dications to identify the fa ult location: *DIP Switch S3-7 m ust be set t o ON for Fault Loopback to operate as illustrate d. The fo llowi ng table l ists the pi n configu ration for th e RJ-48 connecto r. Pin Signal 1 Receive Ring 2 Receive Tip 3 No Connection 4 Transmit R ing 5 Transmit Tip 6 No Connection 7 No Connec ...

  • IMC Networks E1 - page 20

    17 Spec if icat io ns Standard s Com pliance (T1, E1, J1): ANSI T1.102 -1993 ANSI T1.107.199 5 GR-820- CORE T1, E1, J1 Inter face: T1 (1.544 Mbps +/- 32 ppm) E1 (2.048 Mb ps +/- 32 ppm) J1 (1.544 Mbps +/- 32 ppm ) Power Consumption (Typical ): 0.550 Amps @ 5 V Operatin g Temp eratur e: -4°F to +158°F (-2 0°C to +70°C) Storage T empe rature : -4 ...

  • IMC Networks E1 - page 21

    18 Fiber Op tic Cleaning Guide lines Fiber Optic tran smitters an d receivers are e xtremely susce ptible to c ontamination by particles of d irt o r dust, which can obst ruct the optic p ath and cause performance degradation. Good system performan ce requires clean optics and c onnector ferrules. 1. Use fiber patch cord s (or connectors, if you te ...

  • IMC Networks E1 - page 22

    19 El ectro sta ti c Dis charg e Pre cau tions Electrostatic discharge (ESD) can cause dama ge to any product, add- in modules or stand alone units, containing ele ctronic componen ts. Always observe the following precauti ons when installing or han dling these kinds o f products 1. Do not remove unit from its protecti ve pa ckagin g until ready t ...

  • IMC Networks E1 - page 23

    20 Certi fic at ions CE: The products des cribed herein c o mply with the Counci l Directiv e on Electromagne tic Compatibili ty (2004/108/EC) European Directive 2002/96/EC (WEEE) requir es that any equipment that bears this symbol on product or pa ckaging m ust n ot be d ispose d of wit h unsorte d munic ipal waste. This symbol in dicates that the ...

  • IMC Networks E1 - page 24

    19772 Pauling • Foothill Ranc h, CA 92610-26 11 USA TEL: (94 9) 465 -3000 • FAX: (949 ) 465 -3020 www.imcnetworks.com © 2011 I MC Networks. A ll righ ts reserved . The info rmation in this doc ument is su bject to cha nge with o ut no tice . IM C N etwo rk s a ssum es no re spon sibi lity for an y errors th at may appear in this document. IE-i ...

Fabricant IMC Networks Catégorie Network Card

Les documents que nous recevons du fabricant de l'appareilIMC Networks E1 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques IMC Networks
- manuels d’utilisations E1
- fiches produit IMC Networks
- dépliants
- ou étiquettes-énergie IMC Networks E1
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation IMC Networks E1.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation IMC Networks E1, manuels d’entretien, brefs manuels ou manuels de l’utilisateur IMC Networks E1. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit IMC Networks E1.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil IMC Networks E1, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser IMC Networks E1 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs IMC Networks E1.

Le manuel d’utilisation complet IMC Networks, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel IMC Networks E1 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières IMC Networks E1, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lIMC Networks E1 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil IMC Networks E1 - qui devraient nous aider dans les premières étapes lors de l'utilisation IMC Networks E1
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de IMC Networks E1
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service IMC Networks E1 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de IMC Networks E1?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec IMC Networks E1, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec IMC Networks E1 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)