Manuel d’utilisation Goodman AEPT

13 pages 0.32 mb
Télécharger

Aller à la page of 13

Summary
  • Goodman AEPT - page 1

    C US ® Made in the USA by: Goodman Manufacturing Compan y , L. P. IO-230F 2550 North Loop West, Suite 400 - Houston, Texas 77092 08/04 ww w .goodmanmfg.com or ww w .amana-hac.com © 2003-2004 Goodman Manufacturing Compan y , L. P. INS TALLATION & OPER ATING INSTRUCTIONS FOR ARU F , ARP F , ARPT and AEPT SERIES AIR HANDLER ...

  • Goodman AEPT - page 2

    2 IO-230F 08/04 INDEX INTRODUCTION .................................................................... 2 REPLACEMENT P AR TS ........................................................ 2 SAFETY INSTRUCTIONS ...................................................... 2 W ARNINGS ............................................................................ 2 ...

  • Goodman AEPT - page 3

    3 IO-230F 08/04 WARNING THIS PRODUCT IS F ACT OR Y SHIPPED FOR USE W ITH A 208-230/1/60 ELECTRICAL PO WER SUPPL Y . THIS AIR HANDLER MUST NOT BE RECONFIGURED T O OPERA TE W ITH ANY OTHER PO WER SUPPL Y . WARNING WHEN INST ALLING OR SER VICING THIS EQUIPMENT , SAFETY CLOTHING , INCLUDING HAND AND EYE PROTECTION, IS STRONGL Y ADVISED. IF INST ALLING ...

  • Goodman AEPT - page 4

    4 IO-230F 08/04 When matched with a Goodman or Amana brand condenser or heat pump, an ARI certified rating is available for many combinations. The AEPT models are equipped with an ECM TM moto r . An ECM TM motor is more efficient than a standard PSC motor and offers features such as soft-start, controlled off-delays, and constant CFM. Additional fe ...

  • Goodman AEPT - page 5

    5 IO-230F 08/04 maximum heat and allow the system to reach steady state conditions. Insert two thermometers, one in the return air and one in the supply air. The temperature rise is the supply air temperature minus the room air temperature. Use HKR specification sheets to determine the HKR available for a given air handle r. HKR INST ALLA TION Foll ...

  • Goodman AEPT - page 6

    6 IO-230F 08/04 Wire Sizing W ire size is important to the operation of your equipment. Use the following check list when selecting the appropriate wire size for your unit. • Wire size must carry the Minimum Circuit Ampacity (MCA). Refer to the NEC (USA) or CSA (Canada) for wire sizing. The unit MC A for the air handler and the optional electric ...

  • Goodman AEPT - page 7

    7 IO-230F 08/04 Piping Size For the correct tubing size, follow the specification for the condenser/heat pump. WARNING THIS COIL IS SHIPPED UNDER PRESSURE. FOLLOW THESE INSTRUCTIONS T O PREVENT INJUR Y (SEE FIGURES 1 AND 2). Evaporator Coil Metering Devices Flowrater Models (ARUF and ARPF) For most installations no change to the flowrater orifice i ...

  • Goodman AEPT - page 8

    8 IO-230F 08/04 To increase the superheat (measured at the condenser base valve), turn the stem clockwise (in). Similarl y , to decrease the superheat, turn the stem counterclockwise (out). Use a ¼ “ refrigeration wrench for this function. Note: Design point for the system is 10 degrees of superheat (measured at the condenser base valve) at 95 d ...

  • Goodman AEPT - page 9

    9 IO-230F 08/04 To complete the conversion, slide the evaporator coil into t he chass i s and a tt ach t he t h r ee ( 3 ) access pane l s . (Figure 7). CONVERSION TO HORIZONT AL The “B” series product is not suitable for horizontal application and must not be used for this type of installation. The following describes converting to “Horizont ...

  • Goodman AEPT - page 10

    10 IO-230F 08/04 IMPOR T ANT NOTE: THE EV APORA T OR COIL IS COA TED WITH OILS THA T MA Y DISSOL VE STYROFOAM AND CER T AIN TYPES OF PLASTICS. THEREFORE, A REMOV AL PUMP OR FLOA T SWITCH MUST NOT CONT AIN ANY OF THESE MA TERIALS. Tip : Priming the “P” trap may avoid improper draining at the initial installation and at the beginning of the cooli ...

  • Goodman AEPT - page 11

    11 IO-230F 08/04 Humidity Control When using a Humidistat (normally closed), cut jumper PJ6 on the control board. The Humidistat will only affect cooling airflow by adjusting the Airflow to 85%. Two Stage Heating When using staged electric heat, cut jumper PJ4 on the control board. Thermostat Wiring Use thermostat wiring diagram Figures 10 thru 13 ...

  • Goodman AEPT - page 12

    12 IO-230F 08/04 C W2 O Y R YO C G R E W2 TYPICAL H/P ROOM THERMOSTAT HEAT PUMP AR/ARUF/ARPF/ARPT 18-60 10 KW & BELOW (OPTIONAL) OUTDOOR THERMOSTAT CLOSE ON TEMPERATURE FALL RED GREEN WHITE BLUE AR UNIT R Y O W BL #18 GA. 5 WIRE #18 GA. 7 WIRE SEE NOTE #3 R G BR W BL R E D Y E L L O W O R A N G E W H I T E B L U E #18 GA. 6 WIRE NEEDED WHEN OT ...

  • Goodman AEPT - page 13

    13 IO-230F 08/04 Quality Makes the Difference! All of our systems are designed and manufactured with the same high quality standards regardless of size or efficienc y . We have designed these units to significantly reduce the most frequent causes of product failure. They are simple to service and forgiving to operate. We use quality materials and c ...

Fabricant Goodman Catégorie Air Conditioner

Les documents que nous recevons du fabricant de l'appareilGoodman AEPT peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Goodman
- manuels d’utilisations AEPT
- fiches produit Goodman
- dépliants
- ou étiquettes-énergie Goodman AEPT
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Goodman AEPT.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Goodman AEPT, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Goodman AEPT. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Goodman AEPT.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Goodman AEPT, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Goodman AEPT par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Goodman AEPT.

Le manuel d’utilisation complet Goodman, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Goodman AEPT - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Goodman AEPT, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lGoodman AEPT qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Goodman AEPT - qui devraient nous aider dans les premières étapes lors de l'utilisation Goodman AEPT
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Goodman AEPT
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Goodman AEPT dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Goodman AEPT?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Goodman AEPT, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Goodman AEPT il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)