Manuel d’utilisation Generac 04673-2

56 pages 4.9 mb
Télécharger

Aller à la page of 56

Summary
  • Generac 04673-2 - page 1

    PO WER SY STEMS, INC. ® GENERA C POWER SYSTEMS, INC. R R Installation and Owner’ s Man ual Air -cooled A utomatic Standb y Generators Models: 04673-2 (6 kW NG, 7 kW LP) 04674-2 (12 kW NG, 12 kW LP) 04675-3 (13 kW NG, 15 kW LP) DEADL Y EXHAUST FUMES. OUTDOOR INST ALLA TION ONL Y!! D ANGER Not intended f or use as Primary P o wer in place of utili ...

  • Generac 04673-2 - page 2

    Generac ® Pow er Systems, Inc. I NTRODUCTION Thank you for purchasing this model by Generac P ower Systems Inc.. This model is a compact, high performance, air - cooled, engine - driven generator designed to automatically supply electrical power to operate critical loads during a utility power failure. This unit is factory installed in an all-weat ...

  • Generac 04673-2 - page 3

    T able of Cont ents Generac Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Generac ® Pow er Systems, Inc. 1 Introduction ........................Inside F ront Cover Read This Manual Thoroughly ........................IFC Contents ..........................................................IFC Operation and Maintenance ............................IFC ...

  • Generac 04673-2 - page 4

    2 Generac ® Pow er Systems, Inc. Study these SAFETY RULES carefully before installing, operating or servicing this equipment. Become familiar with this Owner’s Manual and with the unit. The generator can operate safely , efficiently and reliably only if it is properly installed, operated and maintained. Many accidents are caused by failing to fo ...

  • Generac 04673-2 - page 5

    Generac ® Pow er Systems, Inc. 3 ELE CTR ICAL HA Z AR DS • All generators covered by this manual produce dangerous electrical voltages and can cause fatal electrical shock. Utility power delivers extremely high and dangerous voltages to the transfer switch as does the standby generator when it is in opera- tion. A void contact with bare wires, t ...

  • Generac 04673-2 - page 6

    Only qualified electricians or contractors should attempt such installations, which must comply strictly with applicable codes, standards and regulations. 1.1 U N P ACKING/I NSP ECTION After unpacking, carefully inspect the contents for damage. • This standby generator set has been factory sup- plied with a weather protective enclosure that is in ...

  • Generac 04673-2 - page 7

    Section 1 — General Information Generac Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Generac ® Pow er Systems, Inc. 5 1.4 TH E GEN ER A T OR Exh aust En c lo su r e Oi l Di p stic k D a t a D ecal C ontro l P a n el F uel Re g ulato r F uel Inl et G F CI O utle t O il Filte r Batter y Com p artmen t Exh aust En c lo su r e O il Filte r Batter ...

  • Generac 04673-2 - page 8

    6 Generac ® Pow er Systems, Inc. Section 1 — General Information Generac Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators 1.5 SP E CI F ICA TIONS 1.5.1 GEN ERA T OR Model 04673 Model 04674 Mo de l 04675 Rated Max. Continuous P ower Capacity (W atts*) 6,000 NG/7,000 LP 12,000 NG/12,000 LP 13,000 NG/15,000 LP Rated V oltage 120/240 120/240 120/240 R ...

  • Generac 04673-2 - page 9

    Generac ® Pow er Systems, Inc. 7 1 . 6 FUE L RE QUIRE MEN T S AN D R E C OM M EN D A TIONS W ith LP gas, use only the vapor withdrawal system. This type of system uses the vapors formed above the liquid fuel in the storage tank. The engine has been fitted with a fuel carburetion system that meets the specifications of the 1997 California Air Resou ...

  • Generac 04673-2 - page 10

    4. Remove the engine air in baffle located on the left - hand side of the battery compartment. T wo M6 screws are located on top of the baffle and two M6 screws are located on the inside of the baffle towards the back. 5. Remove the small hose clamp and hose from the fuel regulator . It may be necessary to pry the hose off of the brass fitting usin ...

  • Generac 04673-2 - page 11

    Generac ® Pow er Systems, Inc. 9 1.1 0 B A TTER Y INST ALLA TION Fill the battery with the proper electrolyte fluid if nec- essary and have the battery fully charged before installing it. Before installing and connecting the battery , complete the following steps: 1. Set the generator's A UTO/OFF/MANU AL switch to OFF . 2. T urn off utility p ...

  • Generac 04673-2 - page 12

    10 Generac ® Pow er Systems, Inc. The following procedur es are to be observed: • Wear full eye pr otection and protective clothing; • Where electr olyte contacts the skin, wash it of f immediately with water; • Where electr olyte contacts the eyes, immediately flush thoroughly with water and seek medical attention; and • Spilled electroly ...

  • Generac 04673-2 - page 13

    Generac ® Pow er Systems, Inc. 11 8. Connect an accurate AC voltmeter and a frequen- cy meter across transfer switch terminal lugs E1 and E2. V oltage should be 242-252 volts; fre- quency should read about 61-63 Hertz. 9. Connect the AC voltmeter test leads across termi- nal lug E1 and neutral; then across E2 and neu- tral. In both cases, voltage ...

  • Generac 04673-2 - page 14

    12 Generac ® Pow er Systems, Inc. 2.6 ADJ US TI NG TH E R E GU L A T OR (NA TUR AL GAS ONL Y) Although the generator has been factory set to pro- vide maximum power , it may be necessary in some areas to adjust this setting . Because natural gas has different BTU or power content across the country the engine may not perform as designed. If experi ...

  • Generac 04673-2 - page 15

    Generac ® Pow er Systems, Inc. 13 Section 2 — Post Installation Start-up and Adjustments Generac Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators 6. When frequency is correct at no load, check the AC voltage reading . If voltage is incorrect, the volt- age regulator may require adjustment. Figure 2.3 — Single Cylinder Engine Governor Adjustment ...

  • Generac 04673-2 - page 16

    14 Generac ® Pow er Systems, Inc. Section 3 — Operation Generac Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators NOTE: The voltage regulator is housed above the genera- tor's control panel. The regulator maintains a volt- age in direct proportion to frequency . F or example, at 62 Hertz, line -to -neutral voltage will be 124 volts. 3.1 B R EA ...

  • Generac 04673-2 - page 17

    Generac ® Pow er Systems, Inc. 15 Upon restoration of utility source voltage above a pre- set level, generator circuit board action signals the transfer switch to transfer loads back to that power supply . After retransfer , the engine is signalled to shut down. The actual sequence of operation is controlled by sensors and timers on a control logi ...

  • Generac 04673-2 - page 18

    16 Generac ® Pow er Systems, Inc. Do not attempt to activate the transfer switch manually until all power voltage supplies to the switch have been positively turned off. Failure to turn off all power voltage supplies may result in extr emely hazardous and possibly fatal electrical shock. 5. Use the manual transfer handle inside the trans- fer swit ...

  • Generac 04673-2 - page 19

    Generac ® Pow er Systems, Inc. 17 3.7 .3.1 Approximat e Crank Cycle T imes • 15 seconds ON • 7 seconds OFF • 7 seconds ON • 7 seconds OFF • Repeat for 45 seconds Approximately 90 seconds total 3.7 .4 OVERSPEED This feature protects the generator from damage by shutting it down if it happens to run faster than the preset limit. This prote ...

  • Generac 04673-2 - page 20

    18 Generac ® Pow er Systems, Inc. NOTE: The unit is supplied with “break-in ” oil. See the “Break -in Procedure,” Section 3.1, for the first required oil change. Any attempt to crank or start the engine before it has been properly serviced with the r ecom- mended oil may result in an engine failur e. 4.3.2 OI L CHANGE PROCEDU R E T o chang ...

  • Generac 04673-2 - page 21

    Generac ® Pow er Systems, Inc. 19 4.6 SP AR K P L UG(S) Reset the spark plug(s) gap or replace the spark plug(s) as necessary . See Section 4.13 for mainte- nance requirements. 1. Clean the area around the base of the spark plug(s) to keep dirt and debris out of the engine. Clean by scraping or washing using a wire brush and commercial solvent. Do ...

  • Generac 04673-2 - page 22

    20 Generac ® Pow er Systems, Inc. 4.8 ADJ US TI NG V AL VE CLEAR ANCE After the first 50 hours of operation, adjust the valve clearance in the engine. Important: If feeling uncomfortable about doing this procedure or the proper tools are not available, contact the nearest Generac Authorized dealer for service assis- tance. This is a very important ...

  • Generac 04673-2 - page 23

    Generac ® Pow er Systems, Inc. 21 4.1 0 A TTENTION AF TER S U B M ERSION If the generator has been submerged in water , it MUST NOT be started and operated. F ollowing any sub- mersion in water , have a Generac Authorized Dealer thor- oughly clean and dry the generator . 4.1 1 C OR ROSION P RO TECTION P eriodically wash and wax the enclosure using ...

  • Generac 04673-2 - page 24

    22 Generac ® Pow er Systems, Inc. Section 4 — Maintenance Generac Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators 4.1 3 SERVICE S CH EDU LE A TTENTION: It is recommended that all service work be performed by the nearest Generac Authorized Dealer . SYSTEM/COMPONENT PROCEDURE FREQUENCY X = Action Inspect Change Clean W = W eekly R = Replace as Nece ...

  • Generac 04673-2 - page 25

    Generac ® Pow er Systems, Inc. 23 Section 5 — T roubleshooting Generac Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators 5.1 TROU B LE SHOO TI NG GU I DE P ROB LEM CAUSE C OR R E CTION The engine will not crank. 1. F use blown 1. Replace 15A fuse on generator control panel. 2. Loose, corroded or defective 2. Tighten, clean or replace battery cables ...

  • Generac 04673-2 - page 26

    24 Generac ® Pow er Systems, Inc. Section 6 — Electrical Data Generac Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Wiring Diagram – 1 2 & 15 kW – Drawing No. 0D85 00-B TX - TRANSFORMER, 16 Vac 56 VA & 16 Vac 1 VA ( DUAL SEC. ) 0 CUS T O MER SU PPLIE D BLA CK BATTERY 12V L OP HT O 0 S P 2 S P 1 IM2 86 85 IM1 D D DIA G RAM KE Y D S W ...

  • Generac 04673-2 - page 27

    Generac ® Pow er Systems, Inc. 25 Section 6 — Electrical Data Generac Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Wiring Diagram – 1 2 & 15 kW – Drawing No. 0D85 00-B C L OS E S T T O BEARIN G G R D 0 4 S TAT OR 1 94 224 224 22 5 1 5 224 17 4 22 5 224B 22 5 0 0 OU TP U T T O TRAN S FE R 22 22 MAN U A L F2 0 1 5A 66A 2 39 1 3 1 5 1 3 1 ...

  • Generac 04673-2 - page 28

    26 Generac ® Pow er Systems, Inc. Section 6 — Electrical Data Generac Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Electrical Schematic – 1 2 & 1 5 kW – Drawing No. 0D85 0 1 -B IM1 - IGNITION MODULE , CYLINDER # 1 IM2 - IGNITION MODULE , CYLINDER # 2 L O P - L O W O IL PRE SSU RE S WIT CH SP1 , SP2 - SPARK PLUG S S W1 - A U T O / O FF ...

  • Generac 04673-2 - page 29

    Generac ® Pow er Systems, Inc. 27 Section 6 — Electrical Data Generac Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Electrical Schematic – 1 2 & 1 5 kW – Drawing No. 0D85 0 1 -B 2 39 IM2 1 5 1 8 S P 2 24 0V IM1 0 1 94 17 1 5 2 3 1 5 2 39 S W 1 1 94 1 5A 22 11 2 3 11 22 11 S P 1 44 WINDIN G 12 0V 12 0V 33 NEUTRAL N2 N1 2 3 CUS T O ME R C ...

  • Generac 04673-2 - page 30

    28 Generac ® Pow er Systems, Inc. Section 6 — Electrical Data Generac Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Wiring Diagram – 7 kW – Drawing No. 0D90 13-C TX - TRANSFORMER, 16 Vac 56 VA & 16 Vac 1 VA ( DUAL SEC. ) CB2 - CIRCUIT BREAKER , ALTERNATOR EXCITATIO N BLA CK CUS T O MER SU PPLIE D BATTERY 12V L OP HT O SP 86 85 IM D D S ...

  • Generac 04673-2 - page 31

    Generac ® Pow er Systems, Inc. 29 Section 6 — Electrical Data Generac Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Wiring Diagram – 7 kW – Drawing No. 0D90 13-C 0 4 C L OS E S T T O BEARI N G R D S TAT OR OU TP U T T O TRAN S FE R 24 0 V G ENERAT OR S WIT C H CO NTA C T OR 8 2 0 66A 1 94 1 5 0 66A 1 5A 2 39 2 3 1 5 1 5A F2 1 3A 1 3 0 1 3 F ...

  • Generac 04673-2 - page 32

    30 Generac ® Pow er Systems, Inc. Section 6 — Electrical Data Generac Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Electrical Schematic – 7 kW – Drawing No. 0D90 1 4-C CB1 - CIRCUIT BREAKER , MAIN OUTPU T HT O - HI G H O IL TEMPERAT U RE S WIT CH S W1 - A U T O / O FF / MAN U AL S WIT CH CB2 - CIRCUIT BREAKER , ALT. EXCITATIO N TX - TRANSF ...

  • Generac 04673-2 - page 33

    Generac ® Pow er Systems, Inc. 31 Section 6 — Electrical Data Generac Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Electrical Schematic – 7 kW – Drawing No. 0D90 1 4-C INP UT 12V dc U TILIT Y CO I L RELAY TRAN S FE R NE U TRA L 120 V 24 0 VA C CUS T O ME R SU PPLIE D 2 3 S W 1 2 39 C 1- 6 0 1 5 17 0 1 8 C 1- 5 0 1 8 0 17 56 1 8 14 1 5A 17 ...

  • Generac 04673-2 - page 34

    32 Generac ® Pow er Systems, Inc. 35 68 49 52 PRE PA C KA G ED U NIT S O NL Y 2 0 2 4 9 46 4 3 4 3 37 33 2 5 35 34 2 6 74 77 7 9 35 4 9 82 80 51 4 6 8 80 4 7 2 87 5 86 76 4 8 39 92 1 8 94 91 63 21 1 5 51 71 42 69 1 0 52 4 9 35 51 4 9 11 31 9 50 99 98 72 4 6 41 57 2 7 91 1 56 5 44 60 4 0 19 1 2 71 6 97 22 65 68 63 16 69 1 4 54 47 55 7 5 4 9 30 17 3 ...

  • Generac 04673-2 - page 35

    Generac ® Pow er Systems, Inc. 33 ITEM P ART NO . QTY . DESCRIPTION 1 0C6140 1 ASSEMBL Y , ENCLOSURE BASE 0D1901 1 ASSEMBL Y , ENCLOSURE BASE (7KW) 2 0C6735 2 SUPPOR T , ROOF FOLDING 3 0F0063 1 ENCLOSURE, FRONT 4 0C7062 1 ENCLOSURE, EXHA UST SIDE 0C7062A 1 ENCLOSURE, EXHA UST SIDE (7KW) 5 0E8811 1 ENCLOSURE, SIDE & BA CK 0E8811A 1 ENCLOSURE, S ...

  • Generac 04673-2 - page 36

    34 Generac ® Pow er Systems, Inc. 31 19 3 7 38 22 8, 9 27 45 46 44 48 47 10 3 49 5 1 13 17 5 21 35 23 49 29 21 17 4 2 38 6 7 33 2 20 27 15 40 41 39 45 44 43 1 30 15 11 47 45 24 45 47 49 Section 7 — Exploded Views and P arts Lists Generac Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Control Panel – Drawing No. 0E7 97 4-G ...

  • Generac 04673-2 - page 37

    Generac ® Pow er Systems, Inc. 35 ITEM P ART NO . QTY . DESCRIPTION 1 0E7886A 1 CIRCUIT BREAKER 30A X 2P 240V (7KW) 0E7886C 1 CIRCUIT BREAKER 40A X 2P 240V (8.5KW) 0E7886D 1 CIRCUIT BREAKER 45A X 2P 240V (11KW) 0E7886E 1 CIRCUIT BREAKER 50A X 2P 240V (12KW) 0E7886F 1 CIRCUIT BREAKER 60A X 2P 240V (13KW) 0E7886G 1 CIRCUIT BREAKER 70A X 2P 240V (15K ...

  • Generac 04673-2 - page 38

    36 Generac ® Pow er Systems, Inc. 1 4 3 47 , 48 , 49 , 50 , 51 , 52 , 53 , 54 , 56 , 57 , 58 , 59 , 60 , 62 , 63 , 64 7, 47 , 48 , 49 , 50 , 51 , 52 , 53 , 54 , 56 , 57 , 58 , 59 , 60 , 63 , 64 53 4 6 48 47 49 50 5 1 5 2 40 38 42 45 44 43 29 143 3 7 26 3 24 1 4 0 3 2 3 35 55 33 36 20 5 7 58 59 6 1 60 6 4 6 2 63 65 1 2 6 3, 32 , 33 , 34 , 35 , 36 , ...

  • Generac 04673-2 - page 39

    Generac ® Pow er Systems, Inc. 37 ITEM P ART NO . QTY . DESCRIPTION 1 0C5729 1 ASSEMBL Y , CRANKCASE HOUSING WITH SLEEVE 2 0E9843 1 SEAL, 38 I.D . CRANKSHAFT 3 090388 3 SCREW , T APTITE M6-1.0 X 12 YC 4 0C5372 1 ASSEMBL Y , BREA THER 5 0C3005 1 GASKET , BREA THER CO VER 6 0E3372B 3 SEP ARA TOR, OIL BREA THER 7 0D8067A 1 ASSEMBL Y , HEAD #1 G&S ...

  • Generac 04673-2 - page 40

    38 Generac ® Pow er Systems, Inc. Section 7 — Exploded Views and P arts Lists Generac Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators GT -990/760 Engine – Drawing No. 0E8 7 7 4-K Part 2 ...

  • Generac 04673-2 - page 41

    Generac ® Pow er Systems, Inc. 39 ITEM P ART NO . QTY . DESCRIPTION 74 0C5136A 2 KNOB, AIR CLEANER 75 0C3024 1 CO VER, AIRBO X NG/LP 76 0C3040 1 PRE-CLEANER, 77 0C8127 1 ELEMENT , AIR CLEANER 78 0D8564A 1 ASSEMBL Y , MIXER/AIRBO X 990 0D8564B 1 ASSEMBL Y , MIXER/AIRBO X 760 79 0D2595 4 SCREW SHOULDER (8MM) M6-1.0 X 18 80 0D4417 4 W ASHER,R UBBER 1 ...

  • Generac 04673-2 - page 42

    40 Generac ® Pow er Systems, Inc. 5 1 23 11 5 3 1 21 53 7 30 13 33 5 2 1 38 3 2 17 28 3 1 3 1 20 14 19 10 17 15 32 2 10 19 16 39 8 6 3 3 2 3 4 30 40 46 45 47 36 1 3 2 4 25 26 34 3 4 48 10 28 27 28 3 2 3 1 18 Section 7 — Exploded Views and P arts Lists Generac Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators 7 kW Generator – Drawing No. 0D35 04-D ...

  • Generac 04673-2 - page 43

    Generac ® Pow er Systems, Inc. 41 Section 7 — Exploded Views and P arts Lists Generac Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators 7 kW Generator – Drawing No. 0D35 04-D ITEM P AR T NO . QTY . DESCRIPTION 1 0C6934 1 AD APT OR, ENGINE 2 0C9935H 1 ST A TOR 3 0C9934H 1 RO TOR 4 0C6043A 1 CARRIER, REAR BEARING 5 0C8096 1 F AN, 8" CUR VED BL ...

  • Generac 04673-2 - page 44

    42 Generac ® Pow er Systems, Inc. 29 3 4 11 2 5 24 43 21 7 13 33 12 38 17 3 2 3 1 28 3 1 20 19 10 17 15 32 16 22 39 8 6 37 14 3 2 40 1 32 24 25 10 30 19 26 28 27 28 3 2 3 1 41 10 18 36 8 35 29 36 36 35 Section 7 — Exploded Views and P arts Lists Generac Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators 1 2 kW and 1 5 kW Generator – Drawing No. 0D ...

  • Generac 04673-2 - page 45

    Generac ® Pow er Systems, Inc. 43 Section 7 — Exploded Views and P arts Lists Generac Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators 1 2 kW and 1 5 kW Generator – Drawing No. 0D3 4 1 7-G ITEM P AR T NO . QTY . DESCRIPTION 1 0C6934 1 AD APT OR, ENGINE 2 0C7930 1 ST A TOR 12KW 0D2359 ST A TOR 13KW / 15KW 3 0C7944 1 RO TOR 12KW 0D2356 RO TOR 13KW ...

  • Generac 04673-2 - page 46

    44 Generac ® Pow er Systems, Inc. 3 2 23 3 4 35 36 45 39 33 20 19 18 43 44 46 11 4 9 29 3 7 2 7 28 30 3 1 17 5 2 47 48 24 38 26 22 40 41 25 25 50 14 12 5 1 13 5 4 16 1 6 1 2 11 10 4 2 5 7 9 8 3 4 Section 7 — Exploded Views and P arts Lists Generac Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators GN4 1 0 Engine – Drawing No. 0E9 1 80-B Part 1 ...

  • Generac 04673-2 - page 47

    Generac ® Pow er Systems, Inc. 45 ITEM P AR T NO . QTY . DESCRIPTION 1 0E3221 1 ASSEMBL Y , CONNECTING ROD 2 0E1466 1 PIN, PIST ON D20 3 021533 1 SET , PIST ON RING 90MM 4 0E2985 1 PIST ON, HC 5 071983 2 RET AINER, PIST ON PIN 20 6 0E8440 1 ASSEMBL Y , CRANKSHAFT GH410 SMALL T APER 7 0A7628 1 ARM, GO VERNOR RC45 8 078658 1 PIN, "R" GO VE ...

  • Generac 04673-2 - page 48

    46 Generac ® Pow er Systems, Inc. 19 20 41 21 22 6 40 3 39 24 6 12 7 6 6 6 14 18 17 3 1 30 27 2 45 38 5 29 13 8 10 11 9 18 18 3 4 1 35 33 3 4 4 6 36 37 Section 7 — Exploded Views and P arts Lists Generac Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators GN4 1 0 Engine – Drawing No. 0E9 1 80-B Part 2 ...

  • Generac 04673-2 - page 49

    Generac ® Pow er Systems, Inc. 47 ITEM P AR T NO . QTY . DESCRIPTION 1 0C1069 5 SCREW , T APTITE M6-1.0X8 YELLO W CHROME 2 0D2922 1 HOUSING, BLO WER 3 0C8435 1 TUBE, DIPSTICK 4 0C9997 1 GU ARD , F AN 5 088434 1 WRAPPER, BO TT OM 6 045756 11 SCREW , T APTITE M6-1X10 YELLO W CHROME 7 0C4176A 1 WRAPPER, T OP 8 0D9004A 1 ASSY , ST AR TER 9 059985 2 SC ...

  • Generac 04673-2 - page 50

    48 Generac ® Pow er Systems, Inc. 17 12 28 11 20 10 3 2 25 21 24 19 23 22 22 15 26 14 13 16 29 18 28 1 2 10 11 27 3 1 4 5 3 2 10 17 1 26 15 14 16 13 3 7 19 9 30 21 25 20 2 4 29 18 23 11 12 28 8 Section 7 — Exploded Views and P arts Lists Generac Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Gas Regulator – Drawing No. 0D8 7 2 0-G ...

  • Generac 04673-2 - page 51

    Generac ® Pow er Systems, Inc. 49 ITEM P AR T NO . QTY . DESCRIPTION 1 0D5694 1 CASTING, TWIN REGULA T OR HOUSING 2 0F5022 1 SOLENOID COIL, 12VDC 3 0C4647 1 GASKET , SOLENOID 4 0D4166 1 PLUNGER, LP REGULA T OR ASSEMBL Y 5 0C6070 1 SPRING-SOLENOID , PLUNGER 8 0F4795 4 SCREW PPHM SEMS M4-0.7 X 10 9 0C5760J 1 JET , GN 410 ENGINE LP (7KW) 10 0C6606 2* ...

  • Generac 04673-2 - page 52

    50 Generac ® Pow er Systems, Inc. Section 8 — Mounting Dimensions Generac Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Drawing No. 0D3 7 3 9-B T M6PEM-T M6P M6PEM PE REAR VIEW L EFT S IDE VIEW TRANSFER SWITCH R I G HT S IDE VIEW F R O NT VIEW AIR NTAKE ( IF SUPPLIED ) " D O N O T LIFT BY THE R OO F" L IFTIN G H O LE S 4- CO RNER S Ø ...

  • Generac 04673-2 - page 53

    Generac ® Pow er Systems, Inc. 51 Section 9 — Notes Generac Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators ...

  • Generac 04673-2 - page 54

    52 Generac ® Pow er Systems, Inc. CALI FOR N IA EM ISSION C ONTROL W AR R ANT Y S T A TEM ENT Y OUR W AR RANT Y R IGHTS AND OB LIGA TIONS The California Air Resources Board (CARB) and Generac P ower Systems, Inc. (Generac) are pleased to explain the Emission Control System W arranty on your new engine. * In California, new utility , and lawn and g ...

  • Generac 04673-2 - page 55

    Generac ® Pow er Systems, Inc. 53 EM IS SION CONTROL S Y S TEM W AR R ANT Y Emission Control System W arranty (ECS W arranty) for 1995 and later model year engines: (a) Applicability: This warranty shall apply to 1995 and later model year engines. The ECS W arranty Period shall begin on the date the new engine or equipment is purchased by/delivere ...

  • Generac 04673-2 - page 56

    Part No. 0F0084 Revision H (03/28/05) Printed in U.S.A. Section 1 0 – W arranty Generac Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators GENERA C PO WER SYSTEMS ST AND ARD TWO-YEAR LIMITED W ARRANTY FOR GENERA C RESIDENTIAL AND LIGHT COMMERCIAL UNITS For a period of two (2) y ears or two thousand (2,000) hours of operation from the date of sale , w ...

Fabricant Generac Catégorie Portable Generator

Les documents que nous recevons du fabricant de l'appareilGenerac 04673-2 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Generac
- manuels d’utilisations 04673-2
- fiches produit Generac
- dépliants
- ou étiquettes-énergie Generac 04673-2
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Generac 04673-2.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Generac 04673-2, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Generac 04673-2. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Generac 04673-2.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Generac 04673-2, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Generac 04673-2 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Generac 04673-2.

Le manuel d’utilisation complet Generac, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Generac 04673-2 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Generac 04673-2, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lGenerac 04673-2 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Generac 04673-2 - qui devraient nous aider dans les premières étapes lors de l'utilisation Generac 04673-2
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Generac 04673-2
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Generac 04673-2 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Generac 04673-2?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Generac 04673-2, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Generac 04673-2 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)