    Operation Manual Smart-UPS ™ C Uninterruptible Power Supply 1000/1500/2000/3000 V A Rack-Mount 2U 120/230 V ac s u 0 0 8 1 2 a ...

  • APC SMC15002U - page 2

    ...

  • APC SMC15002U - page 3

    1 Smart-UPS C 1000/1500/2000/300 0 VA 120/230 Vac Rack-Mount 2U Product Description The APC ™ by Schneider Electric Smart-UPS ™ C is a high performance un interruptible power supply (UPS). The UPS provides protection for electronic eq uipment from AC power blackouts, bro wnouts, sags, and surges, small AC power fluctuations and large disturbanc ...

  • APC SMC15002U - page 4

    Smart-UPS C 1000/1500/2000/3000 VA 120/230 Vac Rack-Mount 2U 2 S pecifications For additional specifications, refer to the APC by Schneider Electric W eb site at www .apc.com. We i g h t specifications UPS + Battery Battery SMC1000-2U / SMC1000I-2U 20.48 kg (45.15 lb) APCRBC124 5.6 kg (12.32 lb) SMC1500-2U / SMC1500I-2U 27.8 kg (61.20 lb) APCRBC132 ...

  • APC SMC15002U - page 5

    3 Smart-UPS C 1000/1500/2000/300 0 VA 120/230 Vac Rack-Mount 2U Product Overview Front p anel features Rear p anel features  Display interface 1000V A 120/230 V ac  Bezel  Battery  Internal battery connector 3000 V A 230 V ac 1500 V A 120/230 V ac 2000 V A 230 V ac       UPS input Circuit breaker/Overload protection Ch ...

  • APC SMC15002U - page 6

    Smart-UPS C 1000/1500/2000/3000 VA 120/230 Vac Rack-Mount 2U 4 Inst allation For UPS installation information, refer to the Installation Guid e for the Smart-UPS C 10 00/1500/200 0/ 3000 V A Rack-Mount 2U in cluded with the UPS. The Installation Guide is also av ailable on the Documentation CD included with the UPS and on the APC by Schneider Elect ...

  • APC SMC15002U - page 7

    5 Smart-UPS C 1000/1500/2000/300 0 VA 120/230 Vac Rack-Mount 2U Operation Note: The UPS will char ge to 90% capacity in th e first three hours of normal operation. Do not expect full battery runtime capabili ty duri ng this initial charge period. 1. Connect equipment to the UPS. 2. Connect the UPS to a two pole , three wire, grounded source. Connec ...

  • APC SMC15002U - page 8

    Smart-UPS C 1000/1500/2000/3000 VA 120/230 Vac Rack-Mount 2U 6 Sensitivi ty adjustment set tings The UPS detects and reacts to line voltage distortions by transferring to battery backup power to protect connected equipment. In situations where the connected eq uipment is too sensitive for the input voltage level it is necessary to adjust the transf ...

  • APC SMC15002U - page 9

    7 Smart-UPS C 1000/1500/2000/300 0 VA 120/230 Vac Rack-Mount 2U LED st atus indicators LCD st atus indicators S tatus LED Audible Indicator On Audible Indicator T erminates Power On The UPS is supplying AC power to connected equipment. The On Line/On Battery LED illuminates green. None N/A On Battery The UPS is supplying battery power from the inte ...

  • APC SMC15002U - page 10

    Smart-UPS C 1000/1500/2000/3000 VA 120/230 Vac Rack-Mount 2U 8 Display interface features 120 V ac 230 V ac Description On Line: The UPS is supplying conditio ned AC power to connected equipment . Green mode : The UPS is operating at the most efficient level, bypassing unused A VR components while acceptable AC voltage is present. The UPS will ente ...

  • APC SMC15002U - page 11

    9 Smart-UPS C 1000/1500/2000/300 0 VA 120/230 Vac Rack-Mount 2U System Fault s For mor e information on System Faults, contac t customer support at the APC by Schneider Electric W eb site, www .apc.com/support. Feature Reference Guide Normal Mode Configuration Mode The Configuration Mode provides additional op tions for the UPS. Press and hold the ...

  • APC SMC15002U - page 12

    Smart-UPS C 1000/1500/2000/3000 VA 120/230 Vac Rack-Mount 2U 10 Function Options Description Self-T est • 0: Default Setting • 1: Begin Self-T est When set to 1, pressing the DISPLA Y button will trigger the self test and exit the Confi guration Mode. 0 is the default setting and will not initiate a self test, by pressing the DISPLA Y button yo ...

  • APC SMC15002U - page 13

    11 Smart-UPS C 1000/1500/20 00/3000 VA 120/230 Vac Rack-Mount 2U T roubleshooting Problem and Possible Cause Solution The UPS will not turn on or there is no output The UPS has not been turned on. Press the ON button once to turn on the UPS. The UPS is not connected to AC power . Be sure the power cable is securely c onnected to the UPS and to the ...

  • APC SMC15002U - page 14

    Smart-UPS C 1000/1500/2000/3000 VA 120/230 Vac Rack-Mount 2U 12 Battery Replacement Always recycle used batte ries. For information on recycling a used ba ttery , refe r to the Battery Disposal Information sheet included with the re placement battery . Replace used batteries with APC by Schneider Elec tric approved batteries. T o order a replacemen ...

  • APC SMC15002U - page 15

    13 Smart-UPS C 1000/1500/20 00/3000 VA 120/230 Vac Rack-Mount 2U T wo Y ear Limited Factory W arranty Schneider Electric IT Corporation (SEIT), warrants its products to be free from defects in materials and workmanship for a period of two (2) years excluding the batteries, which are warranted for one (1) year from the date of purchase. The SEIT ob ...

  • APC SMC15002U - page 16

    Smart-UPS C 1000/1500/2000/3000 VA 120/230 Vac Rack-Mount 2U 14 T o obtain service under warranty you must obtain a Returned Material Au thorization (RMA) number from customer support. Customers with warranty claims issues may access the SEIT worldw ide customer support network through the SEIT W eb site: www .apc.com . Select your country from the ...

  • APC SMC15002U - page 17

    ...

  • APC SMC15002U - page 18

    12/2013 EN 990-4472C APC by Schneider Electric W orldwide Customer Support Customer support for this or any other APC by Schneider Electric product is available at no char ge in any of the following ways: • V isit the APC by Schneider Elec tric W eb site to access documents in the APC by Schneider Electric Knowledge Base and to submit customer su ...

Fabricant APC Catégorie Power Supply

Les documents que nous recevons du fabricant de l'appareilAPC SMC15002U peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques APC
- manuels d’utilisations SMC15002U
- fiches produit APC
- dépliants
- ou étiquettes-énergie APC SMC15002U
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation APC SMC15002U.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation APC SMC15002U, manuels d’entretien, brefs manuels ou manuels de l’utilisateur APC SMC15002U. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit APC SMC15002U.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil APC SMC15002U, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser APC SMC15002U par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs APC SMC15002U.

Le manuel d’utilisation complet APC, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel APC SMC15002U - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières APC SMC15002U, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lAPC SMC15002U qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil APC SMC15002U - qui devraient nous aider dans les premières étapes lors de l'utilisation APC SMC15002U
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de APC SMC15002U
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service APC SMC15002U dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de APC SMC15002U?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec APC SMC15002U, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec APC SMC15002U il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)