Manuel d’utilisation IBM 5074

70 pages 0.9 mb
Télécharger

Aller à la page of 70

Summary
  • IBM 5074 - page 1

    iSeries Setting Up Y our 0578, 5074, 5078 or 5079 Expansion Unit V ersion 5 SA41-5149-02 E Rs e rv e r  ...

  • IBM 5074 - page 2

    ...

  • IBM 5074 - page 3

    iSeries Setting Up Y our 0578, 5074, 5078 or 5079 Expansion Unit V ersion 5 SA41-5149-02 ER s e r v e r  ...

  • IBM 5074 - page 4

    Note Before using this information and the pr oduct it supports, be sure to r ead the information in “Safety and Environmental Notices” on page v and “Notices” on page 51. Third Edition (August 2002) This edition applies only to reduced instruction set computer (RISC)) systems. © Copyright International Business Machines Corporation 2000, ...

  • IBM 5074 - page 5

    Contents Safety and Environmental Notices . . . v Danger Notices ............. v Caution Notices ............. v Laser Safety Information ......... v i Product Recycling and Disposal ....... v i Battery Return Program ......... v i Environmental Design .......... v i About Setting up your 0578, 5074, 5078 or 5079 Expansion Unit (SA41–5149) . . vi ...

  • IBM 5074 - page 6

    iv Setting up your 0578, 5074, 5078 or 5079 Expansion Unit V5R2 ...

  • IBM 5074 - page 7

    Safety and Environmental Notices Danger Notices A danger notice calls attention to a situation that is potentially lethal or extr emely hazardous to people. DANGER An electrical outlet that is not correctly wired could place hazardous voltage on metal parts of the system or the products that attach to the system. It is the customer’s responsibili ...

  • IBM 5074 - page 8

    Laser Compliance All Lasers are certified in the U.S. to conform to the r equirements of DHHS 21 CFR Subchapter J for class 1 laser products. Outside the U.S., they ar e certified to be in compliance with the IEC 825 (first edition 1984) and as a class 1 laser product. Consult the label on each part for laser certification numbers and approval info ...

  • IBM 5074 - page 9

    About Setting up your 0578, 5074, 5078 or 5079 Expansion Unit (SA41 – 5149) This book contains installation about setting up your expansion unit. Y ou may elect to set up your new expansion unit yourself. It will take approximately one to thr ee hours to install the hardwar e Y ou also may elect not to install the expansion unit yourself. Y ou ma ...

  • IBM 5074 - page 10

    Y ou can find mor e information on iSeries Navigator in the iSeries Information Center and at the following W eb site: http://www.ibm.com/eserver/iseries/navigator/ How to send your comments Y our feedback is important in helping to pr ovide the most accurate and high-quality information. If you have any comments about this book or any other iSerie ...

  • IBM 5074 - page 11

    Chapter 1. Preparing to set up your 5074 or 5079 Expansion Unit This chapter explains what you need to do before you set up your 5074 or 5079 Expansion Unit. This includes the following tasks: 1. Unpack your expansion unit (refer to the instr uctions for unpacking that came with your expansion unit). 2. Plan layouts for your cables. 3. Power down y ...

  • IBM 5074 - page 12

    Identifying HSL and SPCN Cables Use the following tables to identify your High Speed link (HSL) and System Power Control Network cables. Y our system uses HSL cables to communicate with your expansion unit. Y our system uses SPCN cables to control power to your expansion unit. Depending on your requir ements, you might not have every HSL or SPCN ca ...

  • IBM 5074 - page 13

    Placing power cords for the 5079 Y ou need to pr ovide the appropriate receptacles for the power cor ds shipped with your 5079. The usable length of the upper unit power cord is 4 ft. (1.2 m) shorter than the length of the lower unit power cord. Redundant links A redundant link is a secondary HSL connection that your system can use if the primary l ...

  • IBM 5074 - page 14

    Figure 2. Planning for redundant link with two expansion units Figure 3. Planning for redundant link with stacked expansion units (5079) 4 Setting up your 0578, 5074, 5078 or 5079 Expansion Unit V5R2 ...

  • IBM 5074 - page 15

    Configuration rules When you set up your expansion unit, observe the rules in T able 4. T able 4. Configuration rules System or expansion unit Configuration rules General v When connecting HSL cables from the system unit to an expansion unit: – Connect the first HSL cable between connector A0 on the system unit (or the first available set of conn ...

  • IBM 5074 - page 16

    T able 4. Configuration rules (continued) System or expansion unit Configuration rules iSeries 830 v The 830 can have a maximum of 13 expansion units on four HSL loops. v Connect HSL loops to the 830 in this order (see Appendix B, “ Connector Locations ” on page 35): 1. B0 and B1 2. C0 and C1 3. D0 and D1 4. A0 and A1 v Connectors A0 and A1, ca ...

  • IBM 5074 - page 17

    If you are setting up a 5074 Expansion Unit, go to Chapter 2, “ Setting up your 5074 expansion unit ” on page 9. If you are setting up a 5079 Expansion Unit, go to Chapter 4, “ Setting up your 5079 Expansion Unit ” on page 19. Chapter 1. Preparing to set up your 5074 or 5079 Expansion Unit 7 ...

  • IBM 5074 - page 18

    8 Setting up your 0578, 5074, 5078 or 5079 Expansion Unit V5R2 ...

  • IBM 5074 - page 19

    Chapter 2. Setting up your 5074 expansion unit This chapter describes how to set up your 5074 Expansion Unit. If you are setting up a 5079 Expansion Unit, go to Chapter 4, “ Setting up your 5079 Expansion Unit ” on page 19. If you have not powered down your system unit, go to “ Powering down your iSeries system unit ” on page 6. Once you ha ...

  • IBM 5074 - page 20

    If you have just one set of HSL connectors on your system unit, they are labeled A0 and A1. If you have more than one set of HSL connectors on your system unit, the first set is labeled A0 and A1. The remaining HSL connectors are labeled alphabetically . For example, if you have an 830, there ar e four sets of HSL connectors on your system. They ar ...

  • IBM 5074 - page 21

    Notes: 1. The graphics that follow designate the HSL connectors for the system unit as 0 and 1. These designations repr esent which set of connectors on your system unit the HSL loop is connected to (for example B0 and B1). 2. These procedur es are intended as a guide. Some steps in the following procedur es may vary depending on the number of HSL ...

  • IBM 5074 - page 22

    __ 1. Remove or open the back cover fr om your 5074. See Appendix A, “ Removing the back covers ” on page 31 if you need instructions. __ 2. Connect the cables to the 5074. See Appendix B, “ Connector Locations ” on page 35 if you need information about finding connectors. __ a. Connect a new HSL cable to HSL connector 1. __ b. Connect a ne ...

  • IBM 5074 - page 23

    Connecting your 5074 to the middle of a loop Use this procedur e if you are connecting your 5074 to the middle of a loop. In other words, you ar e connecting your 5074 between two other expansion units. Refer to these expansion units as unit X and unit Y as is shown in Figure 8 and Figure 9. __ 1. Remove the back cover fr om unit X, unit Y , and yo ...

  • IBM 5074 - page 24

    Connecting your 5074 to the end of a loop Use this procedur e to connect your 5074 in the last position in a loop of expansion units. In this procedur e you will connect your 5074 between your system unit and the expansion unit which is currently in the last position. Refer the expansion unit which is currently in the last position as unit Y as is ...

  • IBM 5074 - page 25

    Chapter 3. Setting up your 0578 expansion unit This chapter describes how to set up your 0578 Expansion Unit. If you have not powered down your system unit, go to “ Powering down your iSeries system unit ” on page 6. Once you have powered down your system unit, return her e. Removing the covers See Appendix A, “ Removing the back covers ” o ...

  • IBM 5074 - page 26

    __ 1. Locate available HSL connectors on your system unit. __ a. Remove or open the back cover for your system unit. See Appendix A, “ Removing the back covers ” on page 31 if you need instructions. __ b. Find the first set of unused HSL connectors on the back of your system unit (Appendix B, “ Connector Locations ” on page 35). If you have ...

  • IBM 5074 - page 27

    __ h. Connect the SPCN cable to connector J15. __ i. Connect the power cable. Do not plug into the wall outlet. __ j. Close or replace the back cover to your 0578. __ 3. Connect the cables from your 0578 to your system unit. __ a. Connect the HSL cable that is labeled 0 to the corresponding HSL connector that you found in step 1c on page 16. __ b. ...

  • IBM 5074 - page 28

    18 Setting up your 0578, 5074, 5078 or 5079 Expansion Unit V5R2 ...

  • IBM 5074 - page 29

    Chapter 4. Setting up your 5079 Expansion Unit This chapter describes how to set up your 5079 Expansion Unit. If you are setting up a 5074 Expansion Unit go, to Chapter 2, “ Setting up your 5074 expansion unit ” on page 9. If you have not powered down your system unit, go to “ Powering down your iSeries system unit ” on page 6. Once you hav ...

  • IBM 5074 - page 30

    __ 1. Find the HSL cables and the SPCN cables in the information that is shipped with your expansion unit. Y ou will use three HSL cables and two SPCN cables to perform this procedur e. __ 2. Attach a label to each end of the cables. Label each of the cables as follows: __ a. Label the two ends of the first cable 0. __ b. Label one end of the secon ...

  • IBM 5074 - page 31

    __ a. Remove or open the back cover on your system unit. See Appendix A, “ Removing the back covers ” on page 31 if you need instructions. __ b. Find the first set of available HSL connectors on the back of your system unit. If you have just one set of HSL connectors on your system unit, they are labeled A0 and A1. If you have more than one set ...

  • IBM 5074 - page 32

    Connecting your 5079 to another expansion unit This section contains instructions for connecting your 5079 expansion unit to a loop with other expansion units. Y ou can only connect your 5079 with other expansion units that have HSL hardwar e. Y our 5079 consists of two independent 5074 Expansion Units in a single frame. These procedur es refer to ...

  • IBM 5074 - page 33

    __ 1. Open the back cover on your 5079. See Appendix A, “ Removing the back covers ” on page 31 if you need instructions. __ 2. Connect the cables to the 5079 – 002 (the upper unit). See Appendix B, “ Connector Locations ” on page 35 if you need information about finding connectors. __ a. Connect a new HSL cable to HSL connector 1. If you ...

  • IBM 5074 - page 34

    __ 10. Connect the HSL cable from 5079 – 001 HSL connector 1 to HSL connector 0 on unit X. This cable should now run between 5079 – 001 and Unit X. __ 1 1. Connect the SPCN cable from 5079 – 001 connector J16 to connector J15 on unit X. This cable should now run between your 5079 – 001 and Unit X. __ 12. Install the covers on unit X, your 5 ...

  • IBM 5074 - page 35

    __ a. Connect a new HSL cable to HSL connector 1. If you have differ ent length cables, this cable should be the shortest one. __ b. Connect a new SPCN cable to connector J16. __ c. Connect the power cable. Do not plug into the wall outlet. If your power cables for the 5079 are two dif ferent lengths, connect the longer cable to 5079 – 002. __ 6. ...

  • IBM 5074 - page 36

    __ 1. Open the back cover on your 5079. See Appendix A, “ Removing the back covers ” on page 31 if you need instructions. __ 2. Connect the cables to 5079 – 002 (the upper unit). See Appendix B, “ Connector Locations ” on page 35 if you need information about finding connectors. __ a. Connect a new HSL cable to HSL connector 0. __ b. Conn ...

  • IBM 5074 - page 37

    Chapter 5. Completing your installation Perform the following steps to return complete your installation: __ 1. Make sure that you have r einstalled all of the covers on the following system components: __ a. iSeries system unit. __ b. All system expansion units. DANGER An electrical outlet that is not correctly wired could place hazardous voltage ...

  • IBM 5074 - page 38

    __ g. Press the Enter push button on the contr ol panel. __ h. Press the Mode Select button until the Normal indicator ( OK ) lights up. __ i. Press the Incr ement/Decrement push button until 01 appears in the Function/Data display . __ j. Press the Enter push button on the contr ol panel. 0 1BS should appear in the Function/Data display and OK is ...

  • IBM 5074 - page 39

    Chapter 6. V erifying Y our New Configuration V erify your new configuration by performing the following: __ 1. T ype strsst on the command line. Pr ess Enter . __ 2. T ype your service tools userid and service tools password on the System Service T ools (SST) Sign On display . Press Enter . __ 3. Select Start a service tool fr om the Start a Servi ...

  • IBM 5074 - page 40

    System Power Control Network Battery capacity tes t.......: Enabled Type options, press Enter. 3=Write VPD 5=Display detail 6=Display trace log 7=Test battery interface Serial Opt Frame Unit Type Number Fault 01 0 00-00000 No 01 1 00-00000 No 03 0 .... 00-00000 No 03 1 .... 00-00000 No 3 02 0 .... 00-00000 No 02 1 .... 00-00000 No __ f. At the Writ ...

  • IBM 5074 - page 41

    Appendix A. Removing the back covers 5075 and 820 back cover Remove the back cover for the system unit by gripping the upper corners of the cover and pulling it up and toward you. 5074, 830 and 890 back cover 1. Use the latch shown at A to open the back cover on your expansion unit. 2. If needed, use the latch shown at B to remove the b ...

  • IBM 5074 - page 42

    5079 and 840 back cover Open the back cover on your 5079 by pressing the latch at A . Figure 21. Removing the 5074 and 830 back cover 32 Setting up your 0578, 5074, 5078 or 5079 Expansion Unit V5R2 ...

  • IBM 5074 - page 43

    Figure 22. Opening the 5079 and 840 back cover Appendix A. Removing the back covers 33 ...

  • IBM 5074 - page 44

    Accessing units in a rack 1. Move to the back of the rack, press latch A , and open the back door of the rack. 34 Setting up your 0578, 5074, 5078 or 5079 Expansion Unit V5R2 ...

  • IBM 5074 - page 45

    Appendix B. Connector Locations 820 HSL connector locations Figure 23. 820 HSL connector locations © Copyright IBM Corp. 2000, 2002 35 ...

  • IBM 5074 - page 46

    830 HSL connector locations Figure 24. 830 HSL connector locations 36 Setting up your 0578, 5074, 5078 or 5079 Expansion Unit V5R2 ...

  • IBM 5074 - page 47

    840 HSL connector locations Figure 25. 840 HSL connector locations Appendix B. Connector Locations 37 ...

  • IBM 5074 - page 48

    890 HSL connector locations Figure 26. 890 HSL connector locations 38 Setting up your 0578, 5074, 5078 or 5079 Expansion Unit V5R2 ...

  • IBM 5074 - page 49

    5079 connector locations Figure 27. 5079 connector locations Appendix B. Connector Locations 39 ...

  • IBM 5074 - page 50

    5074 connector locations Figure 28. 5074 connector locations 40 Setting up your 0578, 5074, 5078 or 5079 Expansion Unit V5R2 ...

  • IBM 5074 - page 51

    5075 connector locations 5078 connector locations Figure 29. 5075 connector locations Figure 30. 5078 connector locations Appendix B. Connector Locations 41 ...

  • IBM 5074 - page 52

    42 Setting up your 0578, 5074, 5078 or 5079 Expansion Unit V5R2 ...

  • IBM 5074 - page 53

    Appendix C. System unit control panel 1. Go to the front of your iSeries system unit. Open the contr ol panel door . 2. Before you can use F Incr ement/Decrement Buttons and G Enter Push button, you need to press H Mode Select to select manual mode K . Y ou will use the push buttons on the contr ol panel. Familiarize yoursel ...

  • IBM 5074 - page 54

    44 Setting up your 0578, 5074, 5078 or 5079 Expansion Unit V5R2 ...

  • IBM 5074 - page 55

    Appendix D. Cabling rules for systems with a migration unit or the 9079 and 9094 expansion unit If you already have a migration unit or a 9079 Expansion Unit set up on your system, there ar e special cabling rules that you must follow . On the table below , find your system unit and follow the rule that apply to your system unit. System unit Rule i ...

  • IBM 5074 - page 56

    System unit Rule iSeries 890 v Y ou can install up to two 5074s or one 5079 with a 9094 on the first loop (A0 and A1). v Set up the SPCN cable for your 5074 or 5079 in the same SPCN loop as the 9094. This is true even though you are connecting the 5074 or 5079 to a differ ent HSL loop than the 9094. Y ou can do this by connecting the SPCN cable fro ...

  • IBM 5074 - page 57

    Figure 33. HSL loop with four external units Figure 34. HSL loop with five external units Figure 35. HSL loop with two 5079s and a 503x Appendix D. Cabling rules for systems with a migration unit or the 9079 and 9094 expansion unit 47 ...

  • IBM 5074 - page 58

    Figure 36. SPCN loop with 503x Figure 37. SPCN and HSL loop with 5077 48 Setting up your 0578, 5074, 5078 or 5079 Expansion Unit V5R2 ...

  • IBM 5074 - page 59

    Figure 38. HSL loop with 0578 Appendix D. Cabling rules for systems with a migration unit or the 9079 and 9094 expansion unit 49 ...

  • IBM 5074 - page 60

    50 Setting up your 0578, 5074, 5078 or 5079 Expansion Unit V5R2 ...

  • IBM 5074 - page 61

    Notices This information was developed for products and services of fered in the U.S.A. IBM may not offer the pr oducts, services, or features discussed in this document in other countries. Consult your local IBM repr esentative for information on the products and services curr ently available in your area. Any refer ence to an IBM product, pr ogra ...

  • IBM 5074 - page 62

    systems and there is no guarantee that these measur ements will be the same on generally available systems. Furthermore, some measur ement may have been estimated through extrapolation. Actual results may vary . Users of this document should verify the applicable data for their specific environment. Information concerning non-IBM products was obtai ...

  • IBM 5074 - page 63

    C-bus is a trademark of Corollary , Inc. in the United States, other countries, or both. Java and all Java-based trademarks are trademarks of Sun Micr osystems, Inc. in the United States, other countries, or both. Microsoft, W indows, W indows NT , and the W indows logo are trademarks of Microsoft Corporation in the United States, other countries, ...

  • IBM 5074 - page 64

    Industry Canada Compliance Statement This Class A digital apparatus meets the requirements of the Canadian Interference-Causing Equipment Regulations. A vis de conformit éà la r é glementation d ’ Industrie Canada Cet appareil num é rique de la classe A respecte toutes les exigences du R è glement sur le mat é riel brouilleur du Canada. Eur ...

  • IBM 5074 - page 65

    This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interferences, and (2) this device must accept any interferences r eceived, including interference that may cause undesired operation. Responsible Party: International Business Machines Corporation New Orch ...

  • IBM 5074 - page 66

    56 Setting up your 0578, 5074, 5078 or 5079 Expansion Unit V5R2 ...

  • IBM 5074 - page 67

    Readers ’ Comments — We ’ d Like to Hear from Y ou iSeries Setting Up Y our 0578, 5074, 5078 or 5079 Expansion Unit V ersion 5 Publication No. SA41-5149-02 Overall, how satisfied are you with the information in this book? V ery Satisfied Satisfied Neutral Dissatisfied V ery Dissatisfied Overall satisfaction hhhhh How satisfied are you that th ...

  • IBM 5074 - page 68

    Readers ’ Comments — We ’ d Like to Hear from Y ou SA41-5149-02 SA41-5149-02  Cut or Fold Along Line Cut or Fold Along Line Fold and T ape Please do not staple Fold and T ape Fold and T ape Please do not staple Fold and T ape NO POST AGE NECESSARY IF MAILED IN THE UNITED ST A TES BUSINESS REPL Y MAIL FIRST -CLASS MAIL PERMIT NO. 4 ...

  • IBM 5074 - page 69

    ...

  • IBM 5074 - page 70

     Printed in U.S.A. SA41-5149-02 ...

Fabricant IBM Catégorie Film Camera

Les documents que nous recevons du fabricant de l'appareilIBM 5074 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques IBM
- manuels d’utilisations 5074
- fiches produit IBM
- dépliants
- ou étiquettes-énergie IBM 5074
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation IBM 5074.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation IBM 5074, manuels d’entretien, brefs manuels ou manuels de l’utilisateur IBM 5074. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit IBM 5074.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil IBM 5074, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser IBM 5074 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs IBM 5074.

Le manuel d’utilisation complet IBM, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel IBM 5074 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières IBM 5074, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lIBM 5074 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil IBM 5074 - qui devraient nous aider dans les premières étapes lors de l'utilisation IBM 5074
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de IBM 5074
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service IBM 5074 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de IBM 5074?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec IBM 5074, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec IBM 5074 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)