    NOTE: Read the entire instruction manual before starting the installation. This symbol → indicates a change since the last issue. SAFETY CONSIDERATIONS Improper installation, adjustment, alteration, service, maintenance, or use can cause explosion, fire, electrical shock, or other conditions which may cause death, personal injury, or property dam ...

  • Bryant 598B - page 2

    INSTALLATION I. CHECK EQUIPMENT AND JOB SITE A. UNPACK UNIT Move to final location. Remove carton, taking care not to damage unit. B. INSPECT EQUIPMENT File claim with shipping company prior to installation if shipment is damaged or incomplete. Locate unit rating plate on unit corner panel. It contains information needed to properly install unit. C ...

  • Bryant 598B - page 3

    INSTALLING TXV IN PLACE OF PISTON 1. Remove any existing refrigerant and ensure coil has not been exposed to atmospheric pressure for more than 15 minutes. 2. Remove indoor coil inlet tube at piston body inlet. Use back-up wrench to prevent damage. 3. Remove piston retainer, begin careful not to damage scaling surface of O-ring. 4. Remove and disca ...

  • Bryant 598B - page 4

    CAUTION: If ANY refrigerant tubing is buried, provide 6 – in. vertical rise at service valve. Refrigerant tubing lengths up to 36 in. may be buried without further special consideration. Buried refrigerant tubing lengths greater than 36 in. are NOT recommended. CAUTION: To prevent damage to unit or service valves, observe the following: • Use a ...

  • Bryant 598B - page 5

    G. FINAL TUBING CHECK IMPORTANT: Check to be certain factory tubing on both indoor and outdoor unit has not shifted during shipment. Ensure tubes are not rubbing against each other or any sheet metal. Pay close attention to feeder tubes, making sure wire ties on feeder tubes are secure and tight. VII. MAKE ELECTRICAL CONNECTIONS WARNING: To avoid p ...

  • Bryant 598B - page 6

    VIII. INSTALL ELECTRICAL ACCESSORIES A. GENERAL Refer to the individual instructions packaged with kits or acces- sories when installing. Available electrical accessories include latent capacity control. See Fig. 11 for typical accessory wiring diagrams. B. LATENT CAPACITY CONTROL (LCC) The purpose of an LCC is to provide a dehumidification mode to ...

  • Bryant 598B - page 7

    O/ W2 W/W1 Y1 / W 2 G R THERMIDIST A T CONTROL MODEL RH V ARIABLE-SPEED CONDENSING FURNACE TW O-SPEED AIR CONDITIONER W/W1 G Y/ Y2 C Y2 R Y1 C DHUM HUM B S1 S2 W2 R C HEA T ST AGE 1 COOL ST AGE 1 COOL ST AGE 2 HEA T ST AGE 2 FA N 24 V A C HOT 24 V A C COMM DEHUMIDIFY HUMIDIFY N/A OUTDOOR SENSOR CONNECTION Y/ Y2 HUMIDIFIER (24 V A C) OUTDOOR SENSOR ...

  • Bryant 598B - page 8

    COOL ST AGE 1 FA N HEA T ST AGE 1 COOL ST AGE 2 N/A 24 V A C HOT R W/W1 Y/Y2 O/W2 Y1/W2 G 24 V A C COMM N/A OUTDOOR SENSOR CONNECTION C B S1 S2 C Y2 C PROGRAMMABLE THERMOST A T MODEL 2S SINGLE-ST AGE FURNACE TW O-SPEED AIR CONDITIONER W R Y1 R G Y See notes 1, 2, 3, and 5 A01501 24 V A C HOT 24 V A C COMM HEA T ST AGE 1 COOL ST AGE 2 FA N R C G W/W ...

  • Bryant 598B - page 9

    24 V A C HO T FA N COOL ST AGE 1 COOL ST AGE 2 HEA T ST AGE 1 HEA T ST AGE 2 R G R G 24 V A C COMM N/A OUTDOOR SENSOR CONNECTION C B S1 S2 C C R PROGRAMMABLE THERMOST A T MODEL 2S FK4C, FV4A OR 40FK F AN COIL J1 JUMPER REMO VE J2 JUMPER FOR HEA T ST AGING TWO-SPEED AIR CONDITIONER DH Y1 Y1 W/W1 O/W2 Y1/W2 W1 Y/Y2 Y2 Y/Y2 O W2 See notes 1, 2, 3, 5, ...

  • Bryant 598B - page 10

    WIRING DIAGRAM NOTES: 1. WIRING MUST CONFORM TO NEC OR LOCAL CODES. 2. UNDERLINED LETTER ON THERMOSTAT TERMINAL INDICATES USAGE. FOR EXAMPLE: O/W2 MEANS O IS ENERGIZED IN COOLING MODE. 3. REFER TO INDOOR UNIT INSTALLATION INSTRUCTIONS FOR ANY ADDITIONAL FEATURES AND WIRING INFORMA- TION. 4. NON-PROGRAMMABLE MODEL 2S01 – B, WHEN USED IN AIR CONDIT ...

  • Bryant 598B - page 11

    X. START-UP CAUTION: To prevent compressor damage or personal injury, observe the following: • Do not overcharge system with refrigerant. • Do not operate unit in a vacuum or at negative pressure. • Do not disable low-pressure switch. CAUTION: To prevent personal injury wear safety glasses, protective clothing, and gloves when handling refrig ...

  • Bryant 598B - page 12

    NOTE: If subcooling charging conditions are not favorable, charge must be weighed in accordance with unit rating plate ± 0.6 oz/ft of 3/8-in. liquid line above or below 15 ft respectively. EXAMPLE: To calculate additional charge required for a 25 ft line set: 25 ft - 15 ft = 10 ft x 0.6 oz/f t=6o zo f additional charge. XII. SYSTEM FUNCTIONS AND S ...

  • Bryant 598B - page 13

    I. PRESSURE SWITCH PROTECTION The outdoor unit is equipped with high- and low-pressure switches. If the control senses the opening of a high or low pressure switch, it will respond as follows: 1. De-energize the compressor low or high speed contactor, 2. Keep the outdoor fan operating for 15 minutes, 3. Display the appropriate error code on the sta ...

  • Bryant 598B - page 14

    XIII. FINAL CHECKS IMPORTANT: Before leaving job, be sure to do the following: 1. Ensure that all wiring and tubing is secure in unit before adding panels and covers. Securely fasten all panels and covers. 2. Tighten service valve stem caps to 1/12 turn past finger tight. 3. Leave Owner ’ s Manual with owner. Explain system opera- tion and period ...

  • Bryant 598B - page 15

    Fig. 15 — Wiring Diagram — 024, 036, 048 A01513 CONNECTION DIAGRAM OCT -t ° LPS HPS OAT -t ° LO HI TO INDO O R UN IT RED CCH FA N C A P YEL RED BRN OFM BL K BL U/ PNK BLU/ PNK YEL / PN K YEL / PNK BRN BRN BLK BLK RED BL U CH 11 21 23 23 YEL BLK BLK BLK C L 11 21 H C STAR T COMP RELAY BRN CAP L2 L1 EQUI P GND DUA L CAP ACI T Y ABC D BLU BRN BR ...

  • Bryant 598B - page 16

    Fig. 16 — Wiring Diagram — 060 A02212 CONNECTION DIAGRA M OCT -t ∞ LPS HPS OAT -t ∞ LO HI T O IN DO O R U NIT RED CCH FA N CA P RED BRN OFM BL K BL U/ PNK BLU / PNK YEL / P NK YEL / PN K BRN BR N BLK RE D BLU CH 11 21 23 13 YEL BLK BLK H C ST ART COMP RELA Y BRN CAP L2 L1 EQUI P GND DUAL CAP A C I TY AB CD BLU BRN BLK YEL BRN BLK C O W Y 2 ...

Fabricant Bryant Catégorie Air Conditioner

Les documents que nous recevons du fabricant de l'appareilBryant 598B peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Bryant
- manuels d’utilisations 598B
- fiches produit Bryant
- dépliants
- ou étiquettes-énergie Bryant 598B
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Bryant 598B.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Bryant 598B, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Bryant 598B. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Bryant 598B.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Bryant 598B, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Bryant 598B par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Bryant 598B.

Le manuel d’utilisation complet Bryant, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Bryant 598B - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Bryant 598B, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lBryant 598B qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Bryant 598B - qui devraient nous aider dans les premières étapes lors de l'utilisation Bryant 598B
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Bryant 598B
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Bryant 598B dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Bryant 598B?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Bryant 598B, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Bryant 598B il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)