Manuel d’utilisation Emerson Process Management MAN-0114

24 pages 1.16 mb
Télécharger

Aller à la page of 24

Summary
  • Emerson Process Management MAN-0114 - page 1

    MAN -0114 Rev 02 September 10, 2014 ECO -SENSE SINGLE CH A NNEL TRANSMITTER User Man ual MODEL: ECO-A-X ...

  • Emerson Process Management MAN-0114 - page 2

    1 Table of C ontents SECTION 1 – SAF ETY INFOR MA TION ......................................................................... 1 1.1 Safety Information – Read B efore Install ation & A pply ing Power ........................................ 1 1.2 Contacting Net Safety Monitoring Inc. ....................................................... ...

  • Emerson Process Management MAN-0114 - page 3

    1 SECTION 1 – SA FET Y INFORMATION WARNING : Rea d and unders tand the co ntents of this m anual pri or to op eration. Fa ilure to do so c ould resu lt in inj ury or d eath. Note: Users are r esponsibl e for c orrect trans lations of this m anual int o their n ative language . 1.1 Safety I nformati o n – Read Before Installation & Applying ...

  • Emerson Process Management MAN-0114 - page 4

    2 SECTION 2 – INSTALLATION INSTRUCTI O NS 2.1 Introduction Important : This manual d escribes the 2- W ire 4 - 20mA versions of the E CO -A-X . T he unit is a fix ed - point m onitor des igned to provide continuous m onitoring of hazardo us gase s in the work place. Monit ored valu es are d isplayed in their en gineeri ng units as well as graphic ...

  • Emerson Process Management MAN-0114 - page 5

    3 2.3 Transmitter / Sensor Location Prior to th e instal lation proc ess , a locatio n plan f or placing the tr ansm itter and se nsor s hould be develope d. F actors s uch as accessi bility, air movem ent, gas d ensit y in relation to a ir, emis sion sources and enviro nm ental variab les aff ect corr ect sensor and transm itter loc ation. Air m o ...

  • Emerson Process Management MAN-0114 - page 6

    4 2.4 T he ECO -A- X Encl osure The ECO -A-X enclosur e is an Alum inum or Stainless Steel exp losion - pro of ( NEMA 4X ) enclos ure as sho wn in Figure 2 - 2. Table 1 : ECO Sense (ECO -A-X) housing and sen sor d im ensions ( A through J ) in I nc hes and mm Table 1 : (cont’d) ECO -A-X Transm itter & senso r I J in mm in mm Transmitter & ...

  • Emerson Process Management MAN-0114 - page 7

    5 WARNING : Q ualif ied personne l shoul d perform the instal lation ac cording to applic able electrica l codes, r egulatio ns and s afety st andards. I nsure c orrect c abling an d sealing f itting practices are im plem ented. Also, never ins tall the sen sor pointi ng up ward s . 2.5 System D esig n Sp eci fications Supply V oltage: 10 to 30 VDC ...

  • Emerson Process Management MAN-0114 - page 8

    6 ECO -A- X Transmit ter B oard Terminals Note: In Table 3, T B1 Term inals (Po wer Term inals) are non - polar ized ; if ( +) 24 VDC is connec ted to TB1 bo ttom term inal, an d (- ) 24VDC conn ected t o TB1 top t erm inal a loop c urrent of 4- 20mA would still be obtain ed. Sensor sep aration S ince the sensor mus t be located where gas is lik el ...

  • Emerson Process Management MAN-0114 - page 9

    7 SECTION 3 – INITIAL START - UP 3.1 “Transmitter Configura ti on” Me nu Figure 3 - 1sho ws the EC O -A-X XMITT ER CONFIG menu use d to acti vate chan nels , precisel y calibrate 4 - 20m A outp uts and set t im e / date. Its m enu s are set at the facto ry an d typicall y not needed by the user . T o access from an y data dis play, place and ...

  • Emerson Process Management MAN-0114 - page 10

    8 SECTION 4 – OPERATING INSTRUCTI ONS 4.1 Routine Sensor Calibrations Calibrat ion is the m os t important f unction f or e nsur ing c orrect operat ion of the EC O -A-X . T he CAL MODE ( flow c hart sho wn in Figur e 4 - 2) is des igned to m ake c alibration qu ick , easy and error free. A s uccess ful ZERO a nd SPAN c alibrat ion requir es onl ...

  • Emerson Process Management MAN-0114 - page 11

    9 Calibration S teps Use the fol lowing s tep - by - s tep proce dure to p erform ZERO and SPAN c alibrati ons. 1. To enter t he CAL MO DE ac tivate the DOW N / C AL ke y with the m agnet and within 5 seconds ac tivate th e EDIT ke y . 2. Using the C al - Cup, apply c lean ZER O gas ( air) f rom canister or be s ure th ere is no back ground target ...

  • Emerson Process Management MAN-0114 - page 12

    10 4.2 ALARM OPERATION The ECO -A-X ha s f ront panel LED indica tors f or Alarm 1 (ALM1) , Alar m 2 (ALM2) and Al arm 3 (FAIL) . W ith 2 - W ire 4 - 20m A operatio n, to cons erve po wer, alar m LED’s only flas h during a larm events. 4.2.1 AL ARM 3 – UNDERSTANDING FAULT / LEVE L O PERATION The “A3” (FAIL) alarm is t ypically dedica ted to ...

  • Emerson Process Management MAN-0114 - page 13

    11 SECTION 5 – SETUP MENU CONFI GUR A TION 5.1 Menus Database Configuration All ECO - A-X configur at ion vari ab les are stor ed in its menu data base. Ma n y menu item s will contain d efault va lues f rom the fac tory and r equire cha nges to bet ter m atch a user ’s partic ular applicat ion. EC O -A-X m enus m ay be configure d from the mag ...

  • Emerson Process Management MAN-0114 - page 14

    12 items /sub m enus . Use ED IT key to displa y the cursor , then activate UP / DOW N ke y to c hange that char acter, act ivate NE XT to m ove the curs or, the n activat e EDIT k e y ag ain to lo ad the new item and r emove th e cursor . Activate N EXT to back out of the s ub - menu. T o vie w SETUP P AGE 2 , activate t he DOW N ke y with the po ...

  • Emerson Process Management MAN-0114 - page 15

    13 Lineariz ation D ata allows non linear si gnals to be lineari zed b y entering t he corr ect curve i nto the ECO -A-X (Figure 5- 4). If Linear ize is set f or NO, t he CUR VE POINT S m enu data is not us ed and no lin earizatio n is app lied. W hen YES, t he CURV E POINT entr ies are used and a straig ht - line approx imation is calcu lated bet ...

  • Emerson Process Management MAN-0114 - page 16

    14 5.4 Alarm S etting s: The Alarm S ettings page has the Alarm 1, 2, 3 Setups, R el a ys an d Event Log submenus shown in Figure 5 -6 . Alarm 1, Alarm 2 and Alar m 3/F ail menus ar e identic al and th erefore described onl y once in this sec tion. I M PO RT AN T : Alarm functions an d their as sociated LED’s ar e a l wa ys ac tive . Set Poi nt e ...

  • Emerson Process Management MAN-0114 - page 17

    15 5.5 Sensor Informati on: Sensor Infor mation has th e SENSO R S ETUP/IN FO m enus shown in Figur e 5 -7 Install N ew Senso r should alwa ys be perf ormed when a new s impl e sens or is inst alled. T his deletes h istorica l CAL data and sets s ensor l ife to 100 % after initial ca libration of the n ew simpl e sensor. Recall Cal Histor y recalls ...

  • Emerson Process Management MAN-0114 - page 18

    16 Warm U p and C al Purg e t im e delays are als o ava ilable to prevent un wanted a larm trips. Fig ure 5-8 shows th e menu f or the se items . Figure 5 -8 : Clock & Cal end ar / Delay T imer M enu 5.7 LCD Contrast Adj: LCD Contras t Adj. ma y be set f or optim um viewin g using the m enu shown in Figur e 5 -9. Figure 5 -9 : LC D Contrast A d ...

  • Emerson Process Management MAN-0114 - page 19

    17 5.1 0 SYSTEM SEC URITY: The SY STEM SECURITY m enu offers two levels of protecti on. A LOW l ev el allo ws CAL MO DE sensor c alibrations but req uires the 4 - d igit Pass Co de prior t o alteri ng menus . HIGH le vel lo ck s the entire menu data base a nd the C AL Mod e until th e corr ect Pass Code is entered. LOW an d HIGH secur ity levels al ...

  • Emerson Process Management MAN-0114 - page 20

    18 SECTION 6 – H OW TO R ETURN EQUI P MENT A Material Return Authori zation n umber is required in order t o retur n equipm ent. Pleas e contact Net Saf ety Monitori ng at (403) 21 9 - 0688 , b efore r eturning eq uipm ent or cons ult our Cus tomer Care Depar tment to possibl y avoid ret urning equipm ent. If you are r equired to return equipm en ...

  • Emerson Process Management MAN-0114 - page 21

    19 Appendix Appendix A: Ele ctrostatic Sensitive Devi ce (ESD) Definitio n: Electros tatic dis charge (E SD) is the trans fer, bet ween bod ies, of an elect rostatic charge caus ed b y direct co ntact or induced by an elect rostatic field. The m ost comm on cause of ESD is p hysica l contac t. Touc hing an obj ect c an cause a discharge of electros ...

  • Emerson Process Management MAN-0114 - page 22

    20 Appendix B : Re sistance Table Distance (Feet) AWG #20 AWG #18 AWG #16 AWG #14 AWG #12 AWG #10 AWG #8 100 1.02 0.64 0.40 0.25 0.16 0.10 0.06 200 2.03 1.28 0.80 0.51 0.32 0.20 0.13 300 3.05 1.92 1.20 0.76 0.48 0.30 0.19 400 4.06 2.55 1.61 1.01 0.64 0.40 0.25 500 5.08 3.20 2.01 1.26 0.79 0.50 0.31 600 6.09 3.83 2.41 1.52 0.95 0.60 0.38 700 7.11 4. ...

  • Emerson Process Management MAN-0114 - page 23

    21 Appendix C : EC O Sense Specifi cations ECO Sense Specification and Certifica tions Range 0- 50 PPM Response Ti me T 20 < 10 se c T50 < 30se c Accuracy ± 3 ppm or ±10% of readi ng, which ever is great er ( 2 5 °C) ± 15% of re ading (at 0 a nd 50 °C) Certified Temperature Range 0°C to + 50 °C ( +32° F to +1 22 ° F) Operati onal Vol ...

  • Emerson Process Management MAN-0114 - page 24

    22 Net Saf ety Monitor ing Inc. 2721 Hop ewell P lace NE, Calgar y, AB Canad a T1 Y 7J7 1- 866 - FIR EGAS ( 347 - 342 7) | ph. (403) 219 - 068 8 | fx . (403) 219 - 0694 http://www .em ersonproc ess.com /saf ety | Email: s afet y.csc@em erson.c om ...

Fabricant Emerson Process Management Catégorie Carbon Monoxide Alarm

Les documents que nous recevons du fabricant de l'appareilEmerson Process Management MAN-0114 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Emerson Process Management
- manuels d’utilisations MAN-0114
- fiches produit Emerson Process Management
- dépliants
- ou étiquettes-énergie Emerson Process Management MAN-0114
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Emerson Process Management MAN-0114.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Emerson Process Management MAN-0114, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Emerson Process Management MAN-0114. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Emerson Process Management MAN-0114.

Manuel d’utilisation complet de l’appareil Emerson Process Management MAN-0114, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Emerson Process Management MAN-0114 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Emerson Process Management MAN-0114.

Le manuel d’utilisation complet Emerson Process Management, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Emerson Process Management MAN-0114 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Emerson Process Management MAN-0114, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lEmerson Process Management MAN-0114 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Emerson Process Management MAN-0114 - qui devraient nous aider dans les premières étapes lors de l'utilisation Emerson Process Management MAN-0114
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Emerson Process Management MAN-0114
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Emerson Process Management MAN-0114 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Emerson Process Management MAN-0114?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Emerson Process Management MAN-0114, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Emerson Process Management MAN-0114 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)