Manuel d’utilisation Regency Z2510L

24 pages 2.49 mb
Télécharger

Aller à la page of 24

Summary
  • Regency Z2510L - page 1

    FPI FIREPLACE PRODUCTS INTERNA TIONAL L TD. 6988 V enture St., Delta, BC Canada, V4G 1H4 908-200 Regency W armHearth High Effi ciency EP A Certifi ed Fireplace MODEL: Z2510L W armHearth Fireplace Owners & Installation Manual 1 1/16/07 T ested by: Installer : Please complete the details on the back cover and leave this manual with the homeowne ...

  • Regency Z2510L - page 2

    Regency Z2510 W armHearth 2 Thank-you for purchasing a REGENCY FIREPLACE PRODUCT . The pride of workmanship that goes into each of our products will give you years of trouble-free enjoyment. This product has been certifi ed by the Environmental Protection Agency of the United States. This means that it meets the strictest standards in providing yo ...

  • Regency Z2510L - page 3

    Regency Z2510 W armHearth 3 T ABLE OF CONTENTS SAFETY LABEL Safety Label for Z2510L ................................................ 4 INST ALLA TION The Regency W armhearth ............................................ 5 Product Details .............................................................. 5 Options ........................................ ...

  • Regency Z2510L - page 4

    Regency Z2510 W armHearth 4 SAFETY LABEL FOR Z2510L This is a copy of the label that accompanies each Regency W armHearth. It is located inside the lower louver opening on the left side. We have printed a copy of the contents here for your review . NOTE: Regency units are constantly being improved. Check the label on the unit and if there is a diff ...

  • Regency Z2510L - page 5

    Regency Z2510 W armHearth 5 THE REGENCY W ARMHEARTH 1) Optional 24 Karat Gold-plated Louvers 2) Clean Glass Air W ash System 3) High Safety Ceramic Glass 4) Optional 24 Karat Gold-plated Door 5) Andirons 6) Convection Air Inlet 7) Optional 150 CFM 2-speed Blower 8) Convection Chamber 9) Secondary Air Source 10) Primary Air Source 11 ) 7-inch Flue P ...

  • Regency Z2510L - page 6

    Regency Z2510 W armHearth 6 Unit Dimensions INST ALLA TION 8) NEVER leave children unattended when there is a fi re burning in the fi replace. 9) Allow the fi replace to cool before servicing. Always shut off any electricity to the fi replace while working on it. This will prevent any possible electrical shock. 10) Regency is not responsible fo ...

  • Regency Z2510L - page 7

    Regency Z2510 W armHearth 7 Framing Specifi cations No Combustibles on Face of Unit Combustibles May Not Extend to Unit Face Do not notch wallboard around standoffs Clearances to Combustibles INST ALLA TION requires a minimum 2 in. (50 mm) clearance. A combustible mantle (to a depth of 10 in.) may be installed no closer than 18 in. (457 mm) above ...

  • Regency Z2510L - page 8

    Regency Z2510 W armHearth 8 HEARTH EXTENSION Note: When the unit is raised 4 inches above the fl oor the Regency Hearth Extension (Part# 000-910) is not required. If you plan to raise the fi replace and hearth extension, build the platform assembly then position fi replace and hearth extension on top. If you are not raising the unit, check that ...

  • Regency Z2510L - page 9

    Regency Z2510 W armHearth 9 V entilated Chase Pan In Canada: Any factory built chimney listed and certifi ed to ULC-S629. Also any of the following chimney covered by ULC-S610 or ULC S604. 1) GSW Heating Products Model JFC 2) Oliver McLeod Ltd. Model PRO-JET3103 3) Security Chimney Ltd. Model ASHT 4) Selkirk Metalbestos Model SS 5) ICC Excel 103 H ...

  • Regency Z2510L - page 10

    Regency Z2510 W armHearth 10 INST ALLA TION ASSEMBL Y STEPS Note: The following steps represent the nor- mal sequence of installation. Each installation is unique, however , and might require different steps. Each step is dealt with in detail in the fol- lowing pages. 1) Install stand-offs and insulation strip to the unit (refer to the Installation ...

  • Regency Z2510L - page 11

    Regency Z2510 W armHearth 11 or platform for support and to prevent cold air from entering the room from under the fi replace, if against an outside wall. The fi replace may be positioned and then the framing built around it, or the framing may be constructed and the fi replace positioned into the opening. The minimum ceiling height is 7 feet. W ...

  • Regency Z2510L - page 12

    Regency Z2510 W armHearth 12 be closed during regular operation because the unit uses outside air for combustion, not room air . 2) Multiple T erminations. When you install more than one chimney in the same chase or within the same general area, we suggest that their terminations be separated by at least 16 in. (410 mm) horizontally and 18 in. (460 ...

  • Regency Z2510L - page 13

    Regency Z2510 W armHearth 13 INST ALLING THE OUTSIDE AIR KIT Combustion air is fed to the fi rebox through a connection on the rear lower left side of the unit. A free fl owing supply of air must be available to this opening at all times. Combustion air may be taken from inside the building if the local building code allows, but performance may s ...

  • Regency Z2510L - page 14

    Regency Z2510 W armHearth 14 INST ALLA TION GRA VITY AIR FEED KIT OPTION The Gravity Air Feed Kit is designed to extend the heat output vent above the WarmHearth or to the front or the side. The upper louver opening is blocked of f and fl ex duct is connected to the vent holes in the top of the unit and run to vent grills installed above the unit ...

  • Regency Z2510L - page 15

    Regency Z2510 W armHearth 15 Central Heat Option Use high temperature silicone to seal the block-off plate to the unit. If necessary drill extra holes in the plate and the unit and secure with extra screws. Note: Make sure the block-off plate is fl ush and fastened tightly to the W armHearth. Important: A tight joint between ma- sonry and the fi ...

  • Regency Z2510L - page 16

    Regency Z2510 W armHearth 16 T ypical Floor Register INST ALLA TION be at the top so they lie fl at. Bend out the lower edge of the valve at 4 places inside the fi replace with pliers so that it can't be pulled out again (refer to Diagram 2). 6) Connect the inlet of the blower to the outlet of the valve using 8 inch diameter metal ducting (r ...

  • Regency Z2510L - page 17

    Regency Z2510 W armHearth 17 2" (51mm) x 4" (102mm) Framing Metal Edging . . . . . . . . . . . . . . . . Extend unit past studs so it is flush with sheeting. Drill & T ap screws INST ALLA TION FINISHING THE W ARMHEARTH Completing the Facing Facing materials must be thin veneer (non-self supporting facades) or self supporting facades. ...

  • Regency Z2510L - page 18

    Regency Z2510 W armHearth 18 T op View T op View INST ALLA TION T op View 4) Place side metal fi ller strips in between stove and framing to cover the stand-off space. Fit the strips behind "A" so that they cover the stand-offs, and will prevent mortar from falling through the mesh. 5) Center door arch edge, mark and drill holes. Note th ...

  • Regency Z2510L - page 19

    Regency Z2510 W armHearth 19 INST ALLA TION MASONR Y LINER/ BRICKS Insulated refractory panels are included to extend the life of the fi replace and help radiate heat more evenly . Make sure Insulating Paper is in place along the bottom, side and rear before bricks are put into place. Insulation batt, 1 in. thick is placed above the top brick baf? ...

  • Regency Z2510L - page 20

    Regency Z2510 W armHearth 20 MAINTENANCE MAINTENANCE Gold Plated Doors and Louvers The optional gold electroplated fi nish on the doors and louvers requires little maintenance and needs only to be cleaned with a damp cloth. DO NOT use abrasive materials or chemical cleaners, as they may harm the fi nish and void the warranty . Keep doors and louv ...

  • Regency Z2510L - page 21

    Regency Z2510 W armHearth 21 P ARTS LIST P ARTS LIST - FIREBOX & BODY Part # Description Part # Description 20) 948-102 Spring Handle - Small 21) 000-198 Hearth Extension Connector 22) * Shell Inner Sides & Back 23) * Insulation - Right 24) * Insulation - Rear 25) * Insulation - Rear - 6" wide 26) * Insulation - Left 27) * Insulation - ...

  • Regency Z2510L - page 22

    Regency Z2510 W armHearth 22 P ARTS LIST P ARTS LIST - BAFFLES, DOOR, OPTIONS Part # Description 1) 000-920 Masonry Retainer Kit (Optional) 846-91 1 Door Assembly- Gold 846-917 Door Assembly- Black 3) 846-300 Glass - Replacement 4) 936-243 7/8" Adhesive T ape 5) 846-920 Glass Retainer Clips (set of 8) 6) * Screw 1/4-20 x 3/8" 7) 948-174/P ...

  • Regency Z2510L - page 23

    Regency Z2510 W armHearth 23 W ARRANTY Regency Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance T e am carefully inspects each unit thoroughly before it leaves our door . FPI Fireplace Products International Ltd. is pleased to extend this limited lifetime warranty to the original p ...

  • Regency Z2510L - page 24

    Installer: Please complete the following information Dealer Name & Address: ______________________________________________ ___________________________________________________________________ Installer: ___________________________________________________________ Phone #: ___________________________________________________________ Date Installed: ...

Fabricant Regency Catégorie Indoor Fireplace

Les documents que nous recevons du fabricant de l'appareilRegency Z2510L peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Regency
- manuels d’utilisations Z2510L
- fiches produit Regency
- dépliants
- ou étiquettes-énergie Regency Z2510L
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Regency Z2510L.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Regency Z2510L, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Regency Z2510L. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Regency Z2510L.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Regency Z2510L, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Regency Z2510L par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Regency Z2510L.

Le manuel d’utilisation complet Regency, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Regency Z2510L - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Regency Z2510L, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lRegency Z2510L qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Regency Z2510L - qui devraient nous aider dans les premières étapes lors de l'utilisation Regency Z2510L
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Regency Z2510L
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Regency Z2510L dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Regency Z2510L?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Regency Z2510L, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Regency Z2510L il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)