Manuel d’utilisation Key Digital 8400

25 pages 0.12 mb
Télécharger

Aller à la page of 25

Summary
  • Key Digital 8400 - page 1

    3.206 Alpha Servers TM AlphaServer 8400 V97-2.1—24 Jul 1997 DIGITAL Systems and Options Catalog Product Description The AlphaServer 8400—using the world’s fastest microprocessors, the Alpha 21164 300 MHz or 440 MHz CPUs—is the world’s fastest and highest capacity enterprise server. It is the solution for the most demanding business proble ...

  • Key Digital 8400 - page 2

    AlphaServer 8400 Alpha Servers 3.207 Step 1—Base Systems AlphaServer 8400 5/300 Systems require - DIGITAL UNIX V3.2B or later, and OpenVMS V6.2 or later AlphaServer 8400 5/440 Systems require - DIGITAL UNIX V3.2G or DIGITAL UNIX V4.0A, or OpenVMS V6.2-1H3 or V7.1 Software media and documentation required for first system on site. See Step 13 for ...

  • Key Digital 8400 - page 3

    AlphaServer 8400 3.208 Alpha Servers Step 1—Base Systems (continued) AlphaServer 8400 Expanded Base Servers include: Processor module with - Two Alpha microprocessor 21164 5/300 MHz or 5/440 MHz CPUs; each CPU includes 4-MB Backup cache System I/O module with four I/O channels (KFTHA- AA) 512 MB, 2 GB or 4 GB of memory BA660-AB StorageWorks Plug- ...

  • Key Digital 8400 - page 4

    AlphaServer 8400 Alpha Servers 3.209 Step 1a—5/300 System Building Blocks System Building Blocks are an alternative to standard Base Servers, or Expanded Base Servers. They provide flexibility in configuring the AlphaServer 8400 with a choice of memory and I/O options. System Building Block Requirements: Minimum of one Memory module Minimum of on ...

  • Key Digital 8400 - page 5

    AlphaServer 8400 3.210 Alpha Servers Step 1b—AlphaServer Expansion Packages AlphaServer Expansion Packages are designed to be added to Base AlphaServers, Expanded Base Servers, and System Building Blocks to create fully functional CI cluster add-on systems. They include all the necessary hardware (excluding console terminal) and software to provi ...

  • Key Digital 8400 - page 6

    AlphaServer 8400 Alpha Servers 3.211 Step 3a—Memory Upgrades Memory upgrades are field installed only (not configured in Manufacturing). MS7CC-UA 128 MB memory upgrade (8 MB SIMMs); upgrades 128 MB (-BA) module to 256 MB (-CA) module MS7CC-UB 512 MB memory upgrade (32 MB SIMMs); upgrades 512 MB (-DA) module to 1 GB (-EA) module Step 3b—Prestose ...

  • Key Digital 8400 - page 7

    AlphaServer 8400 3.212 Alpha Servers Step 5—System I/O Modules KFTIA-AA system I/O module included with Base Server; KFTHA-AA included with Expanded Base Server—any combination of KFTIA or KFTHA modules can be added for a maximum of three. - Maximum twelve I/O channels available on AlphaServer 8400. System Building Block requires the selection ...

  • Key Digital 8400 - page 8

    AlphaServer 8400 Alpha Servers 3.213 Step 6—Storage Controllers (continued) PCI-based Storage Controllers KZPAC-AA PCI one-port SCSI RAID Controller with 4 MB cache memory— Uses one PCI slot. Provides one fast/wide single-ended connection. Allows RAID levels 0, 1 and 5. Includes RAID Array 230/plus subsystem software and documentation kit. KFE7 ...

  • Key Digital 8400 - page 9

    AlphaServer 8400 3.214 Alpha Servers Step 6—Storage Controllers (continued) CIPCA-AA PCI-to-CI Adapter (OpenVMS only)— Requires OpenVMS V6.2-1H3 or V7.1, minimum System Console Firmware Revision 4.0-4. Maximum four per PCI, 26 per system running OpenVMS V7.1. Uses one PCI slot for adapter and one EISA slot for power only. Note: KFE70 option is ...

  • Key Digital 8400 - page 10

    AlphaServer 8400 Alpha Servers 3.215 Step 6a—Non-Backplane External Storage Controllers (continued) HSZ54-AJ StorageWorks RAID Array 450/HSZ50 512 MB quad SCSI controllers, 12 SCSI channels, 72 SCSI- two-device connections, 64 LUN maximum, four cache modules, two dual external cache battery system building blocks, four external cache batteries, f ...

  • Key Digital 8400 - page 11

    AlphaServer 8400 3.216 Alpha Servers Step 7—Storage (continued) Wide SCSI Options ( continued ) BA35X-MG 8-bit I/O Personality Module —can be used in place of 16-bit I/O personality module for direct connection to narrow single-ended controllers, field installable only. Note : BA35X-ME terminators must be ordered separately to split a BA356 bus ...

  • Key Digital 8400 - page 12

    AlphaServer 8400 Alpha Servers 3.217 Step 7a—StorageWorks Expansion Packages ( continued ) SW820/SW821 StorageWorks Expansion Packages—all BA356 shelves operate in split-bus mode. All SW82x StorageWorks Expansion Packages include redundant power supplies (BA35X-HF)—this reduces the number of available slots in each BA356 shelf to six in the S ...

  • Key Digital 8400 - page 13

    AlphaServer 8400 3.218 Alpha Servers Step 8—Networks and Communications Two twisted-pair 802.3/Ethernet controllers on KFTIA-AA system I/O module included with Base Server; DE500 fast ethernet network interface card included with Expanded Base Server. See Step 5 for twisted-pair Ethernet cable part number. Optional DEFPZ-AA/UA (FDDI) daughter car ...

  • Key Digital 8400 - page 14

    AlphaServer 8400 Alpha Servers 3.219 Step 8—Networks and Communications (continued LAN Communications Controllers EISA based Requires DWLPB-AA and KFE70-AA, EISA bridge module set. See EISA Bus IRQ Address Table. DNSES-AA Synchronous Communications Controller (uses one EISA slot). DIGITAL UNIX supports two per EISA, maximum two per system. OpenVM ...

  • Key Digital 8400 - page 15

    AlphaServer 8400 3.220 Alpha Servers Step 8a—MEMORY CHANNEL Controller DIGITAL UNIX Systems Require DIGITAL UNIX V3.2E (DIGITAL UNIX V3.2D plus TruCluster software or MEMORY CHANNEL Driver software). Each system node in a MEMORY CHANNEL cluster requires a software license. Servers in a compute-server array require a DIGITAL UNIX Driver for MEMORY ...

  • Key Digital 8400 - page 16

    AlphaServer 8400 Alpha Servers 3.221 Step 9—Console Terminal Console terminal with EIA-232 25-pin DSUB connector and printer required unless otherwise available. Shielded console cable is included for connection to the console terminal. VT510-xx VT510 terminal LA30N-xx LA30 printer LK461-xx/LK46W-xx Keyboard Step 10—Expansion—System Cabinet a ...

  • Key Digital 8400 - page 17

    AlphaServer 8400 3.222 Alpha Servers Step 11a Three-Phase Expansion Components For new system orders, or for systems shipped after June 1996: Select additional H7263-AC/AD for systems that do not require battery back-up option - If EPU value of 1st regulator is exceeded - If N+1 redundancy is required - If 2nd or 3rd power regulator is required Sel ...

  • Key Digital 8400 - page 18

    AlphaServer 8400 Alpha Servers 3.223 Step 12—Software Select user licenses and additional software as required. Media and documentation recommended for first system on site. Software Processor Code = Q DIGITAL UNIX Concurrent Use Licenses DIGITAL UNIX Concurrent Use licenses are not specific to a single system and can be moved from one system to ...

  • Key Digital 8400 - page 19

    AlphaServer 8400 3.224 Alpha Servers Step 12—Software (continued) OpenVMS QL-MTFAQ-AA DECnet/OSI end-system license QL-MTHAQ-AA DECnet/OSI extended function license QL-MUZAQ-AA OpenVMS cluster software license. Required with each system that connects to an OpenVMS cluster. OpenVMS Media and Documentation QA-MT1AA-H8 OpenVMS media and documentatio ...

  • Key Digital 8400 - page 20

    AlphaServer 8400 Alpha Servers 3.225 Step 13—Hardware and Software Supplemental Support Services (continued) Software—Americas and Asia Pacific only Systems include 90-day Conformance to SPD and Telephone Advisory Support. Select optional Software Supplemental Support Services, if required. Software service upgrades for DIGITAL UNIX and OpenVMS ...

  • Key Digital 8400 - page 21

    AlphaServer 8400 Power Configuration Table 3.226 Alpha Servers AlphaServer 8400 EPU (Equivalent Power Units) Power Configuration Table Second power regulator may be needed to supply additional 48V power to the system. Mixing of three-phase and single-phase power regulators in system configuration is not allowed. Use chart to determine need for seco ...

  • Key Digital 8400 - page 22

    AlphaServer 8400 Alpha Servers 3.227 Optional Controller Configuration Table With multiple adapters that provide the same interface available on different I/O buses (PCI or XMI), it is possible to exceed operating system limit on number of ports supported for that interface. Follow these guidelines for maximum number of ports that each operating sy ...

  • Key Digital 8400 - page 23

    AlphaServer 8400 3.228 Alpha Servers System Diagram Note: Three-Phase Power Systems support up to three Power Regulators. High-speed System Interconnect Bus 1-14 CPUs Memory I/O Port 48-Volt Power Regu- lator Cooling Assembly Space for Additional Power Regulators Space for one or two BA655 or BA660 PIUs Cooling Assembly BU-3310A Expansion Bay for: ...

  • Key Digital 8400 - page 24

    AlphaServer 8400 Alpha Servers 3.229 Specifications Physical Characteristics Operating Shipping Height Width Depth Weight, full configuration Without batteries With batteries 170.0 cm (67.0 in.) 80.0 cm (31.5 in.) 87.5 cm (34.4 in.) 408 kg (900 lb.) 545 kg (1200 lb.) 195.0 cm (76.7 in.) 109.5 cm (43.1 in.) 121.0 cm (47.5 in.) 448 kg (1000 lb.) 585 ...

  • Key Digital 8400 - page 25

    AlphaServer 8400 3.230 Alpha Servers UPS Solutions For complete protection, UPS products should be used with data line surge protectors. See TVSS section of Environmental Products Chapter. 4N-GA249-AB 2 wire modem wall plug in 4N-GA249-CA 10BaseT wall plug in 4N-GA510-BF ThinWire device port 4N-GA245-xx Din rail and modules up to 32 ports Receptacl ...

Fabricant Key Digital Catégorie Server

Les documents que nous recevons du fabricant de l'appareilKey Digital 8400 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Key Digital
- manuels d’utilisations 8400
- fiches produit Key Digital
- dépliants
- ou étiquettes-énergie Key Digital 8400
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Key Digital 8400.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Key Digital 8400, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Key Digital 8400. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Key Digital 8400.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Key Digital 8400, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Key Digital 8400 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Key Digital 8400.

Le manuel d’utilisation complet Key Digital, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Key Digital 8400 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Key Digital 8400, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lKey Digital 8400 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Key Digital 8400 - qui devraient nous aider dans les premières étapes lors de l'utilisation Key Digital 8400
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Key Digital 8400
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Key Digital 8400 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Key Digital 8400?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Key Digital 8400, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Key Digital 8400 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)