    1 Owner ’ s Manual Installation and Operation Models: BIR42 Wood Burning Fireplace DO NOT DISCARD THIS MANUAL NOTICE •  Important operating  and maintenance  instructions included. • Leavethis manualwith party responsible for use and operation. •  Read, understand  and follow these  instructio ...

  • Heatiator BIR42 - page 2

    2 Read this manual before installing or operating this replace. Please retain this owner ’ s manual for future reference. Homeowner Reference Information ModelName:  Datepurchased/installed: SerialNumber:  Locationonreplace: Dealershippurchasedfrom:  Dealerphone: Notes: We recommend that ...

  • Heatiator BIR42 - page 3

    3 Safety Alert Key: • DANGER! Indicatesahazardoussituationwhich,ifnotavoidedwillresultindeathorseriousinjury . • W ARNING! Indicatesahazardoussituationwhich,ifnotavoided could resultindeathorseriousinjury . • CAUTION! Indicatesahazardoussituatio ...

  • Heatiator BIR42 - page 4

    4 W arranty 4021-645C 12-29-10 Page 1 of 2 Hearth & Home T echnologies Inc. LIMITED LIFETIME W ARRANTY Hearth & Home T echnologies Inc., on behalf of its hearth brands (”HHT”), extends the following warranty for HHT gas, wood, pellet, coal and electric hearth appliances that are purchased from an HHT authorized dealer . W ARRANTY COVERA ...

  • Heatiator BIR42 - page 5

    5 4021-645C 12-29-10 Page 2 of 2 W ARRANTY CONDITIONS: • This warranty only covers HHT appliances that are purchased through an HHT authorized dealer or distributor . A list of HHT authorized dealers is available on the HHT branded websites. • This warranty is only valid while the HHT appliance remains at the site of original installation. • ...

  • Heatiator BIR42 - page 6

    6 1 Listing and C od e Appro vals Notice: This replace is tested and approved as a decorative rep lace. It should not be factored as a pr imar y he at sourc e in residentia l heating calculati ons. W ARNING! Risk of Fire! Hearth & Home T echnologies disclaims any responsibility for , and the warranty and agency listing will be voided by t ...

  • Heatiator BIR42 - page 7

    7 2 Operating Inst ructions W ARNING! DO NOT operate  replace before reading and understanding operating instructions. Failure to operate  replace according to operating instructions could cause  re or injury . User Guide W ARNING Hot screen/mesh and glass doors will cause burns. • Donottouchscreen/meshorglassdoors? ...

  • Heatiator BIR42 - page 8

    8 D. Grate Thisreplaceisdesignedtobeusedwiththegratesup- pliedwiththisunitoroneapprovedbyHHT .Thegratewill deteriorateovertimeandwillneedoccasionalreplacement. W ARNING! Risk of Fire! Use only the factory-supplied integral grate. • Keeps logs in place. • A ...

  • Heatiator BIR42 - page 9

    9 W ARNING! Risk of Fire and Smoke! Fireplaces equipped with doors should be operated only with doors fully open or doors fully closed. If doors are left partly open, gas and  ame may be drawn out of the  replace opening. FULL Y OPEN CORRECT P ARTL Y CLOSED INCORRECT P ARTL Y OPEN INCORRECT FULL Y CLOSED CORRECT Figure 2.2 Operating Positions ...

  • Heatiator BIR42 - page 10

    10 M. Wood Fuel Hardwood vs Softwood Y ourreplaceperformancedependsonthequalityofthe rewoodyouuse. • Seasonedwoodcontainsabout8,000BTUsperpound. • Hardwoodsaremoredensethansoftwoods. • Hardwoodscontain60%moreBTUsthansoftwood ...

  • Heatiator BIR42 - page 11

    1 1 3 Maintenance and Ser vice A. Disposal of Ashes Frequency: Whentheyreachbottomofgrate By: Homeowner B. Chimney Inspection/Cleaning Frequency: Atleasttwiceayearduringheatingseasonor asrecommendedbyacertiedchimneysweep By: Certiedchimneysweep Figure 3.1 Chimney & T ermina ...

  • Heatiator BIR42 - page 12

    12 C. Check Firebox Molded Brick Panel Frequency: Aftereachashremoval By: Homeowner D. Inspect Grate Frequency: Aftereachashremoval By: Homeowner Inspectgratefor: • W arpingorsagging1-1/2in.(38mm)ormore • Brokenwelds • Burn-throughofgratebars Forsafeoperation,replac ...

  • Heatiator BIR42 - page 13

    13 4 T rou bl eshoo t ing Guide Start Fire Problems Possible Cause Solution Can’tgetrestarted Excessivesmokeorspillage Burnstooslowly Smolders,sizzles Notenoughkindling/paperorno kindling/paper Usedrykindling,morepaper . Arrangekindling&woodfor airmovement. Damper? ...

  • Heatiator BIR42 - page 14

    14 Non-combustible roof flashing maintains minimum clearance around chimney Additional lateral support for chimney above roof (or enclosed in chase) if needed (Section 8.A.) Ceiling firestop on floor of attic (Section 8.D.) Support straps on rafter supports chimney (not shown) T ermination cap (Sections 8.I., 9.D.) Chimney penetrates roof preferabl ...

  • Heatiator BIR42 - page 15

    15 B. Design and Installation Considerations Draftisthepressuredifferenceneededtoventreplaces successfully .Whenareplaceisdraftingsuccessfully ,all combustionby-productsareexitingthehomethroughthe chimney . Considerationsforsuccessfuldraftinclude: • Pr ...

  • Heatiator BIR42 - page 16

    16 Marginal Location: • Below peak Location NOT recommended: • Not the highest point of the roof • Wind loading possible Multi-level Roofs Windward Leeward Recommended Location: • Above peak Recommended: • Insulated exterior chase in cooler climates Recommended Location: • Above peak • Inside heated space Location NOT recommended: • ...

  • Heatiator BIR42 - page 17

    17 Beforebeginningtheinstallationbesurethefollowingtools andbuildingsuppliesareavailable: Reciprocatingsaw Framingmaterial Pliers Non-combustiblesealant Hammer Gloves Phillipsscrewdriver Framingsquare Flatbladescrewdriver Electricdrillandbits Plumbline Safety? ...

  • Heatiator BIR42 - page 18

    18 6 F raming & Clearances A F D B C 5/8 in. (16 mm) all configurations 1-1/2 in. min. air space from fireplace to combustible materials. 1/2 in. min. air space at nailing flanges. Note: In an exterior chase or projecting into a garage Across a corner As a room divider Along a wall 84 in. (2134 mm) G B E Note: In addition to these framing dimen ...

  • Heatiator BIR42 - page 19

    19 B. Clearances W ARNING! Risk of Fire! Y ou must comply with all minimum air space clearances to combustibles as specied in Fig - ure 6.2. DO NOT pack required air spaces with insulation or other materials. Heatilator•BirminghamBIR42•4059-308RevJ•1/1 1 (insulation) Attic Insulation Shield (ceiling) (roof) (atti ...

  • Heatiator BIR42 - page 20

    20 D. Frame the Fireplace Figure6.4showstypicalframingusingcombustiblematerials(2x4lumbershown). • ObserveallrequiredairspaceclearancestocombustiblematerialsasshowninFigure6.2. 18 1/2 in. [470 mm] 19 3/4 in. [500 mm] 4 in. [102 mm] 50° angle 39° angle 24 in. [610 mm] BRICK ...

  • Heatiator BIR42 - page 21

    21 7 Installation of F ireplace CAUTION! Risk of Cuts/Abrasions. Wear protective gloves and safety glasses during installation. Sheet metal edges are sharp. A. Things to Consider • Location(s)ofoutsideairkit(s) • Gaslinepiping B. Position the Fireplace • Placethereplaceonacontinuousatsurfa ...

  • Heatiator BIR42 - page 22

    22 Outlet placed higher than 3 ft below the termination cap Attic space Garage or combustible liquids storage Outlet blocked by snow , leaves, etc. Clear area outside house or in ventilated crawl space YES NO NO NO NO Factory-built fireplace Use only duct materials specified by manufacturer (preferably with short run or mainly straight duct, except ...

  • Heatiator BIR42 - page 23

    23 Outside Air Hood 2 Wire T ies Flexible Duct (not supplied) Figure 7.5 Outside Air Installation E. Install Outside Air Kit • K e e p  d u c t  r u n s  s h o r t  a n d  s t r a i g h t  t o  m i n i m i z e restriction. • The outsideair kitsmust beinstalled onboth sidesof the ...

  • Heatiator BIR42 - page 24

    24 Chimney must extend beyond combustible roof structure Maintain minimum height of chimney above roof Additional support for tall chimneys Install roof flashing according to minimum requirements Maintain minimum clearances to combustibles as specified Offsets/returns may not exceed 30° from vertical Lock chimney sections together firmly to resist ...

  • Heatiator BIR42 - page 25

    25 A. Chimney Requirements Measureverticaldistancesfromthebaseofthereplace asshowninFigure8.2. 20 ft (6.10 m) max. pipe between an offset & return Ceiling firestop 35 ft (10.7 m) max. straight unsupported chimney height 18.5 ft (5.64 m) min. height single offset-return 90 ft (27.4 m) max. height 6 ft (1 ...

  • Heatiator BIR42 - page 26

    26 T able 8.2 B. Using Offsets/Returns • Useanoffset/returntobypassoverheadobstructions. • Anoffsetandreturncanbeusedasasingleentityorseparatedbychimneysection(s). W ARNING! Risk of Fire! DO NOT use offset/returns greater than 30°. Chimney draft will be restricted and could c ...

  • Heatiator BIR42 - page 27

    27 Figure 8.4 Assembling Chimney Sections • Support the pipe during construction and check to be sure inadv ertent loadin g has not dislo dged the chimn ey sectio n fromthereplaceoratanychimneyjoint. • Attach a straight chimney section or an ...

  • Heatiator BIR42 - page 28

    28 ROOM ABOVE (non-insulated ceiling) A TTIC ABOVE (insulated ceiling) B A Ceilng firestop from bottom Ceiling firestop from top Note: Use same dimensional lumber for framing ceiling firestop and joists. Figure 8.5 Installing the Ceiling Firestop • Insta ll a ceil ing res top when ever chi mney pen etrates ceiling/oo ...

  • Heatiator BIR42 - page 29

    29 Installationofaceilingrestopisrequired • RefertoFigures8.6-8.8. • Rollthe shieldaroundthe chimney(if chimneyisalready installed)until you havea 3in. (76mm) overlapand the threeholesoneachsidematchup(largehole ...

  • Heatiator BIR42 - page 30

    30 G. Complete Installation W ARNING! Risk of Fire! Y ou MUST maintain 2 in. (51 mm) air space to insulation and other combustible ma - terials around the chimney system. Failure to do so could cause overheating and re. • Keepchimneysectionsfromseparatingortwisting. • Y ou may secure straight chimney se ...

  • Heatiator BIR42 - page 31

    31 Slanted Roofs Flat Roofs Chimney must extend 3 ft (.9 m) above the roof Chimney must extend 2 ft (.6 m) above any portion of the roof or adjacent structures within 10 ft (3 m) of the chimney Chimney must extend 3 ft (.9 m) above the roof Chimney must extend 2 ft (.6 m) above any portion of the roof or adjacent structures within 10 ft (3 m) of th ...

  • Heatiator BIR42 - page 32

    32 9 Ch a se Installations Ceiling Firestop Metal Chase T op Round T ermination Cap False Ceiling Insulation in the outside walls of the chase Attic Insulation Shield Chimney Ceiling Firestop T abs False Ceiling False Ceiling Insulation Insulation Figure 9.1 Chase Assembly 1 2 3 1. Fireplace and chimney enclosed in an exterior chase. 2. Chimney off ...

  • Heatiator BIR42 - page 33

    33 Slope Downward (1/4 in. per foot minimum) T urn-down Drip Edge Chase 2 in. (51 mm) Collar on Chase T op .018 (26 ga) min. Galvanized Chase T op Figure 9.3 Chase T op Construction B. Install Fireplace & Chimney InstallasperSections7and8. Heatilator•BirminghamBIR42•4059-308RevJ•1/1 1 C. Instal ...

  • Heatiator BIR42 - page 34

    34 D. Install T ermination Cap Installthechimneysectionsupthroughthechaseenclo- sure. •  Install termination caps following instructions provided withthem. W ARNING! Risk of Fire! The minimum overlap of cap to pipe (as shown in the following illustrations) MUST be met or chimney may separate from ca ...

  • Heatiator BIR42 - page 35

    35 Heatilator•BirminghamBIR42•4059-308RevJ•1/1 1 Chimney Pipe Chase T op T ermination Cap Chase Collar 2 in. (51 mm) Minimum Height Remove 2 screws from front & back to lift the top off T ermination cap pipe and chimney section must overlap 1-1/2 in. (38 mm) Place waterproof sealer under each flange of the termi ...

  • Heatiator BIR42 - page 36

    36 3 in. (76 mm) tall legs Ø 17 1/2 in. (444.5 mm) Round Hole to fit over cap Length x Width to fit inside shroud Figure 10.1 Radiation Shield •  Chase top shrouds may be field constructed where  permittedbyregionalbuildingcodes. W ARNING! Risk of Fire! Shrouds must be constructed as specied. Improper co ...

  • Heatiator BIR42 - page 37

    37 3 in. (76 mm) Min. Opening Height Min. Base Dim Min. Height above radiation shield Min. Base Dim 3 in. (76 mm) Min. Radiation Shield Height from top of Chase Min. Opening Width Figure 10.3 Mailbox Style Shroud Dimensions Mailbox Style Shroud (radiation shield required) Roofed Style Shroud (Radiation Shield Required) Minimum Opening Height Minimu ...

  • Heatiator BIR42 - page 38

    38 Front Lower Back Molded Brick Panel Hearth Molded Brick Panel Upper Back Molded Brick Panel Upper Side Molded Brick Panel Lower Side Molded Brick Panel Right Side Molded Brick Panel removed for clarity 1 1 Installat ion of Molded Brick Panel A. Install Hearth Molded Brick Panel • Placehearthpanelintothereplace. C. Install ...

  • Heatiator BIR42 - page 39

    39 Figure 1 1.2 Herringbone Molded Brick Panel Not e : Use T - brac k ets as templates and dr ill pilot hole s into theinnershellwit hthedrillbitprovided.Sidepane lsmust beinstalle drst. E. Install Back Molded Brick Panel - Herring - bone • RefertoFigure1 1.2. • ...

  • Heatiator BIR42 - page 40

    40 Center of Fireplace Opening Round end of Rod through rings, then into Screen Rod Clip The non-combustible finishing material across the top of fireplace opening will be even with lower edge of metal face. Non-combustible finishing materials MUST overlap side faces by 1 1/4 in. (32 mm) to cover the edges of the panels. Finished opening should be ...

  • Heatiator BIR42 - page 41

    41 1 2 F inishing A. Non-combustible Materials • Materials whichwill not ignite andburn, composed of any combinationofthefollowing: - Steel  - Iron - Brick  - T ile - Concrete - Slate - Glass - Plasters • Materials reported as passing ASTM E 136, ...

  • Heatiator BIR42 - page 42

    42 IMPORT ANT! Hear th ext ension design  must  be de termined beforeinstallati onofreplac e. Floor Non-combustible Framing Material Non-combustible Finishing Material Protective Metal Hearth Strips 1 in. Micore or equivalent insulation & 1/2 in. Durock Bottom of fireplace opening Note: The bottom of the fireplace ...

  • Heatiator BIR42 - page 43

    43 Non-combustible Sealant Aftercompletingtheframingandapplyingthefacingmate- rialsovertheframing,abeadofnon-combustiblesealant mustbeusedtocloseoffanygapsatthetopandsides betweenthereplaceandhearth. Non-combustible Sealant Note: The bottom o ...

  • Heatiator BIR42 - page 44

    44 These surfaces must be covered with non-combustible material. Non-combustible sealant. D. Finishing Material RefertoSections12.A.andSections12.B.forcombustible/ non-combustiblematerials.RefertoFigure12.10fornon- combustiblezone. W ARNING! Risk of Fire! Y ou must maintain clearances. • Use only no ...

  • Heatiator BIR42 - page 45

    45 E. Combustible Mantel • RefertotheshadedareasofFigure12.1 1forthelocationanddimensionsofacombustiblemantel. • A combustiblemantelmaybepositionednolowerthan22in.(508mm)abovethetopofthereplaceopening. • A combustiblemant ...

  • Heatiator BIR42 - page 46

    46 F . Mantel, Adding Extra Support Ifextrasupportforthemantelisneededacrossthefrontof thereplace: •  Obtain a piece of top/bottom  track used in metal  framing. • Cutthetrackto577/8in.(1470mm)long. • N o t c h  e a c h  e n d  o ...

  • Heatiator BIR42 - page 47

    47 18 1/2 in. [470 mm] 19 3/4 in. [500 mm] 4 in. [102 mm] 50° angle 39° angle 24 in. [610 mm] BRICK FRONT FLUSH FRONT 24 in. [610 mm] 22 3/8 in. [568 mm] 52-7/8 in. (1343 mm) 42 in. [1067 mm] Note: Grid depicts 1 inch squares. G. Sidewalls/Surrounds •  Adjacent combustible sidewalls must be located a  minimumof24? ...

  • Heatiator BIR42 - page 48

    48 A. Gas Log/Lighter Provision W ARNING! Fire and/or Asphyxiation Risk! Use with solid wood fuel or decorative gas appliance only . Gas re gener - ates fumes.   install unvented gas logs • Damper must be locked fully open when gas logs are installed Firebox Repack insulation knockout Combustible materials Maintain a ...

  • Heatiator BIR42 - page 49

    49 1 4 Reference Materials A. Fireplace Dimensions 16 1/8 in. 408 mm Gas Line Knockout 1 1 1/8 in. 282 mm 6 7/8 in. 175 mm 5 in. 129 mm 42 in. 1067 mm 52 7/8 in. 1343 mm 3 3/4 in. 97 mm 38 in. 965 mm 54 in. 1372 mm 74 1/8 in. 1883 mm 97 1/2in. 2477 mm 70 3/4 in. 1797 mm 16 1/8 in. 408 mm 1 1 1/8 in. 282 mm 6 7/8 in. 175 mm 5 in. 129 mm 37 1/8 in. 9 ...

  • Heatiator BIR42 - page 50

    50 B. Optional Components DFG4042 Series Glass Doors (optional) 20 in. (508 mm) 66 in. (1676 mm) 1/2 in. (13 mm) HX4 Hearth Extension DFS4042 Series Screen Doors (optional) ID6 Insulated Duct UD6 Uninsulated Duct 42 in. (1067 mm) 6 in. (152.4 mm) i.d. 42 in. (1067 mm) 6 in. (152.4 mm) i.d. Heatilator•BirminghamBIR42•4059-308Re ...

  • Heatiator BIR42 - page 51

    51 C. Chimney Components Thefollowingpicturesshowonlythosechimneycomponentswhichmaybesafelyusedwiththisreplace. Heatilator•BirminghamBIR42•4059-308RevJ•1/1 1 Catalog # A B in mm in mm SL1 106 6 152 4-3/4 121 SL1 1 12 12 305 10-3/4 273 SL1 1 18 18 457 16-3/4 425 SL1 136 ...

  • Heatiator BIR42 - page 52

    52 Heatilator•BirminghamBIR42•4059-308RevJ•1/1 1 SL1 130 Offset/Return AS10 Straight Attic Insulation Shield Assembled Diameter: 17 in./432 mm Height: 24 in./610 mm JB577 Chimney Joint Band CB576 Chimney Joint Band 13 in. (330 mm) 2 in. (51 mm) 13 in. (330 mm) A B 17 in. (432 mm) Catalog # A B FS538 0-deg. 17 in. 43 ...

  • Heatiator BIR42 - page 53

    53 26 in. 10 3/4 in. Heatilator•BirminghamBIR42•4059-308RevJ•1/1 1 TR1 1 - Round T ermination Cap TR1 1T - Round T elescoping T ermination Cap ST1 175 - Square T ermination Cap TCT1 175 - T erra Cotta Cap 15-3/4 in. (400 mm) 32-3/8 in. (822 mm) 34-3/8 in . (873 mm) 23 in. (584 mm) 19 in. (483 mm) 15-5/8 in. (397 mm) ...

  • Heatiator BIR42 - page 54

    54 Heatilator•BirminghamBIR42•4059-308RevJ•1/1 1 DTO134 A B C in 34 20 24 mm 864 508 610 DTO146 in 46 22.7 26 mm 1168 576 660 DTS134 in 34 21.18 24 mm 864 538 610 DTS146 in 46 21.18 26 mm 1168 538 660 B C B A C A DTS134 /DTS146 DTO134 / DT O146 Decorative Caps LDS-BV Decorative Shroud E D A C B CT56 Chase T op 72 in ...

  • Heatiator BIR42 - page 55

    55 D. Service Parts Service Parts 02/1 1 42 in. Woodburning Fireplace BIR42 Beginning Manufacturing Date: May 2008 Ending Manufacturing Date: Active IMPORT ANT :THISISDA TEDINFORMA TION.Whenrequestingserviceorreplacement partsforyourappliancepleaseprovidemodelnumber andserialnumber .All ...

  • Heatiator BIR42 - page 56

    56 – NOTES – E. Contact Information DO NOT DISCARD THIS MANUAL CAUTION •  Important operating  and maintenance  instructions included. • Leavethis manualwith party responsible for use and operation. •  Read, understand  and follow these  instructions for safe installation and operation. DO N ...

Fabricant Heatiator Catégorie Indoor Fireplace

Les documents que nous recevons du fabricant de l'appareilHeatiator BIR42 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Heatiator
- manuels d’utilisations BIR42
- fiches produit Heatiator
- dépliants
- ou étiquettes-énergie Heatiator BIR42
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Heatiator BIR42.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Heatiator BIR42, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Heatiator BIR42. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Heatiator BIR42.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Heatiator BIR42, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Heatiator BIR42 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Heatiator BIR42.

Le manuel d’utilisation complet Heatiator, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Heatiator BIR42 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Heatiator BIR42, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lHeatiator BIR42 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Heatiator BIR42 - qui devraient nous aider dans les premières étapes lors de l'utilisation Heatiator BIR42
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Heatiator BIR42
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Heatiator BIR42 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Heatiator BIR42?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Heatiator BIR42, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Heatiator BIR42 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)