Manuel d’utilisation Omega Engineering CN8260

31 pages 0.28 mb
Télécharger

Aller à la page of 31

Summary
  • Omega Engineering CN8260 - page 1

    CN 82 40 & C N8 26 0 Se ri es C om mu ni ca ti on s & Op ti on s www .omega.com e-mail: info@omega.com ome ga. com ® ® CN8240 & CN8260 SERIES Communications & Options Guide User ’ s Guide TM 10002 Athena Omega:900M124U00.qxd 5/13/08 2:39 PM Page 1 ...

  • Omega Engineering CN8260 - page 2

    CN 82 40 & C N8 26 0 Se ri es C om mu ni ca ti on s & Op ti on s i It is t he p olic y of OME GA to com ply with al l wo rldw ide safe ty a nd E MC/E MI r egu lati ons that app ly . OME GA is cons tant ly p ursui ng cer tifi cati on of its prod ucts to the Euro pean New App roac h Dir ectiv es. OME GA wi ll a dd t he C E ma rk t o ev ery ap ...

  • Omega Engineering CN8260 - page 3

    CN 82 40 & C N8 26 0 Se ri es C om mu ni ca ti on s & Op ti on s ii T able of Contents For inf or mation and instructions related to basic operations , refer to the CN8240/CN8260 operator’ s manual supplied with your controller . Option Wiring Diagrams Alarm Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Omega Engineering CN8260 - page 4

    1 2 3 1 1 12 13 2 3 2 4 RCV B(-) XMT A(+) SIG GND SIG GND RS 232 RS 485 RCV XMT SIG GND CN 82 40 & C N8 26 0 Se ri es C om mu ni ca ti on s & Op ti on s 1 Option -C2: RS-232 (one-to-one) Communications Option Description: Provides a one-to-one connection between the controller and an RS-232 port. Computers, PLCs, or dumb terminals may be us ...

  • Omega Engineering CN8260 - page 5

    CN 82 40 & C N8 26 0 Se ri es C om mu ni ca ti on s & Op ti on s 2 RS-485 Communications 1 2 3 1 1 12 13 14 2 3 2 4 4 RCV B(-) XMT A(+) SIG GND SIG GND RS 232 RS 485 Option Description: Provides one-to-many communications. T erminate the controller furthest from the computer by either connecting a 120-ohm, 1/4-watt resistor between ter- min ...

  • Omega Engineering CN8260 - page 6

    Option Description: Remote setpoints use either voltage or current inputs, depending on the specified option: Option -DIC: Switch Input Closed Option -RSP4: 0-5 Vdc Option -RSP5: 1-5 Vdc Option -RSP6: 0-20 mA Option -RSP7: 4-20 mA The input signal is scalable in the Remote Analog Setpoint Menu. Activation of the analog setpoint causes the F1 indica ...

  • Omega Engineering CN8260 - page 7

    CN 82 40 & C N8 26 0 Se ri es C om mu ni ca ti on s & Op ti on s 4 CN8240/CN8260 Series Controllers with Digital Communications Option ome ga.c om ® ® 10002 Athena Omega:900M124U00.qxd 5/13/08 2:39 PM Page 7 ...

  • Omega Engineering CN8260 - page 8

    CN 82 40 & C N8 26 0 Se ri es C om mu ni ca ti on s & Op ti on s 5 Di git al Co mmu nic at ion s O pti on This method allows bidirectional data transfer via a three-conductor cable consisting of signal ground, receive input and transmit output. It is recommended for communication distances less than 50 feet between the computer termi- nal a ...

  • Omega Engineering CN8260 - page 9

    Message Code Value = Decimal Value 00 0 + 0 = 00 99 90 + 9 = 99 A0 100 + 0 = 100 A2 100 + 2 = 102 B8 110 + 8 = 118 P5 250 + 5 = 255 CN 82 40 & C N8 26 0 Se ri es C om mu ni ca ti on s & Op ti on s 6 Omega+ Protocol The Omega+ Protocol provides an easy way to query and modify controller parameters using a personal computer and the optional d ...

  • Omega Engineering CN8260 - page 10

    CN 82 40 & C N8 26 0 Se ri es C om mu ni ca ti on s & Op ti on s 7 TYPE character Message T ype R Read Request or Read Response Returning a Positive Result r Read Response Returning a Negative Result W Write Positive Value Request and Response w Write Negative Value Request and Response A Auxiliary Command Di git al Co mmu nic at ion s O pt ...

  • Omega Engineering CN8260 - page 11

    CN 82 40 & C N8 26 0 Se ri es C om mu ni ca ti on s & Op ti on s 8 Di git al Co mmu nic at ion s O pti on Numeric Value ASCII Representation 3 3.0000 000003 003.00 100 100.00 0100.0 000100 3.2 003.20 0003.2 Examples of valid numeric representations f or a 6 character data field: Numeric Value Bad ASCII Representation Why? 3 BBBBB3 Leading b ...

  • Omega Engineering CN8260 - page 12

    CN 82 40 & C N8 26 0 Se ri es C om mu ni ca ti on s & Op ti on s 9 READ RESPONSE FROM CONTROLLER READ COMMAND TO CONTROLLER Controller ID Read Command Checksum Start of Message Zone Number Parameter Number End of Message $0101R01B7<CR> Controller ID Read Command Data Checksum Start of Message Zone Number Parameter Number End of Messag ...

  • Omega Engineering CN8260 - page 13

    CN 82 40 & C N8 26 0 Se ri es C om mu ni ca ti on s & Op ti on s 10 WRITE RESPONSE FROM CONTROLLER Controller ID Write Command No Error Checksum Start of Message Zone Number Parameter Number End of Message %0101W090H8<CR> A UX IL I AR Y R ES P O NS E F R O M CO N T RO LL E R A UX IL I AR Y C O M MA N D T O C O N TR O L L ER Controller ...

  • Omega Engineering CN8260 - page 14

    CN 82 40 & C N8 26 0 Se ri es C om mu ni ca ti on s & Op ti on s 11 Di git al Co mmu nic at ion s O pti on The Read Request: The Read Request is used to query parameter values and it has the following message format: [ST ART CHAR][ID][ZONE][TYPE][PARAM][CHKSUM][END CHAR] Field Description: TYPE Must contain the uppercase letter ‘R’. Req ...

  • Omega Engineering CN8260 - page 15

    Request Message Description $Ø1Ø1WØ91Ø.123G7<CR> Change both the RAM and EEPROM copies of Setpoint #1 in controller #1 to the value of 10.123 $Ø1Ø1w1Ø1Ø.123J1<CR> Change only the RAM copy of setpoint #1 in controller #1 to the value of -10.123 (notice the lowercase ‘w’). END CHAR CHKSUM DA TA P ARAM TYPE ZONE ID ST ART CHAR ...

  • Omega Engineering CN8260 - page 16

    CN 82 40 & C N8 26 0 Se ri es C om mu ni ca ti on s & Op ti on s 13 Request Message Description $Ø1Ø1AØ1XXXXXXXXXXL2<CR> T ell controller #1 to load all parameters with their defaults. The 10 X’ s are padding characters. $Ø2Ø1AØ2ØØØ1.ØØØØØ69<CR> T ell controller #2 to perform a low RTD calibration. END CHAR CHKSU ...

  • Omega Engineering CN8260 - page 17

    CN 82 40 & C N8 26 0 Se ri es C om mu ni ca ti on s & Op ti on s 14 Request Message Description %Ø1Ø1RØ5Ø21.123K8<CR> The value of the Process Variable is 21.123 Degrees C. %Ø2Ø1R1Ø1G7<CR> A serial transmission has occurred: Framing Error %Ø1Ø1rØ9Ø21.ØØØN8<CR> The value of the EEPROM setpoint #1 is -21 Degree ...

  • Omega Engineering CN8260 - page 18

    CN 82 40 & C N8 26 0 Se ri es C om mu ni ca ti on s & Op ti on s 15 Request Message Description %Ø1Ø1AØ1ØXXXXXXXXXXØ4<CR> Default load all parameters has started. %Ø2Ø1AØ2ØØ.ØØØØØØØØB6<CR> RTD low calibration on controller #2 has started. END CHAR CHKSUM DA TA ST ATUS P ARAM TYPE ZONE ID ST ART CHAR Di git al C ...

  • Omega Engineering CN8260 - page 19

    CN 82 40 & C N8 26 0 Se ri es C om mu ni ca ti on s & Op ti on s 16 Di git al Co mmu nic at ion s O pti on T able 1. Continued Number Name Read Write Data Field Value 5 Process Value X 0 6 Operating Mode X X 1 - Manual 2 - Standby 3 - Normal (automatic) 4 - Initiate Autotune 5 - Recipe Run 6 - Recipe Hold 7 Access Level X X 1 - Lockout 2 - ...

  • Omega Engineering CN8260 - page 20

    CN 82 40 & C N8 26 0 Se ri es C om mu ni ca ti on s & Op ti on s 17 Di git al Co mmu nic at ion s O pti on T able 1. Continued Number Name Read Write Data Field Value 39 Autotune Damping X X 1 - Low 2 - Normal 3 - High 40 Recipe Option X X 0 - Disabled X X 1 - Single Step X X 2 - Multi-Step 41 Single-Setpoint X X Ramp Time 42-49 Ramp Times ...

  • Omega Engineering CN8260 - page 21

    CN 82 40 & C N8 26 0 Se ri es C om mu ni ca ti on s & Op ti on s 18 Di git al Co mmu nic at ion s O pti on T able 1. Continued Number Name Read Write Data Field Value 92 Input T ype X X 0 - B Thermocouple 1 - C Thermocouple 2 - E Thermocouple 3 - J Thermocouple 4 - K Thermocouple 5 - N Thermocouple 6 - NNM Thermocouple 7 - R Thermocouple 8 ...

  • Omega Engineering CN8260 - page 22

    CN 82 40 & C N8 26 0 Se ri es C om mu ni ca ti on s & Op ti on s 19 Di git al Co mmu nic at ion s O pti on T able 1. Continued Number Name Read Write Data Field Value A2 Output 1 Cycle Time X X A3 Output 1 Low Limit X X A4 Output 1 High Limit X X A5 Output 2 T ype X X 1 - Inactive/Disabled 2 - PID 4 - On/Off A6 Output 2 Action X X 1 - Direc ...

  • Omega Engineering CN8260 - page 23

    CN 82 40 & C N8 26 0 Se ri es C om mu ni ca ti on s & Op ti on s 20 Di git al Co mmu nic at ion s O pti on T able 1. Continued Number Name Read Write Data Field Value D0 Alarm 2 Delay X X D1 Alarm 2 Inhibit X X D2 Alarm 2 Process Setpoint X X D3 Alarm 2 Deviation Setpoint X X D4 Communications Protocol X 0 1 - Omega + D5 Communications ID X ...

  • Omega Engineering CN8260 - page 24

    CN 82 40 & C N8 26 0 Se ri es C om mu ni ca ti on s & Op ti on s 21 Di git al Co mmu nic at ion s O pti on T able 1. Continued Number Name Read Write Data Field Value F6 High-Voltage Span Calibration X X F7 Current Zero Calibration X X F8 Current Span Calibration X X G1 Auxiliary Output Variable X X G2 Auxiliary Output Scale Low X X G3 Auxi ...

  • Omega Engineering CN8260 - page 25

    CN 82 40 & C N8 26 0 Se ri es C om mu ni ca ti on s & Op ti on s 22 Auxiliary Commands: Command: Load Parameter Defaults Parameter #: 01 Description Restore all menu parameters to their default values. Request Data Field: Ignored. Response Data Field: Ignored. Command: Perform Process Low Calibration Parameter #: 02 Description: Performs a ...

  • Omega Engineering CN8260 - page 26

    CN 82 40 & C N8 26 0 Se ri es C om mu ni ca ti on s & Op ti on s 23 Request Data Fields: A 10-character ASCII representation of a numeric value specifying what to calibrate. 0 - Thermocouple 1 - RTD, Resistive Thermal Device 2 - Linear 3 - RAS, Remote Analog Setpoint Response Data Field: Ignored. Command: Perform Process High Calibration Pa ...

  • Omega Engineering CN8260 - page 27

    CN 82 40 & C N8 26 0 Se ri es C om mu ni ca ti on s & Op ti on s 24 No tes 10002 Athena Omega:900M124U00.qxd 5/13/08 2:39 PM Page 27 ...

  • Omega Engineering CN8260 - page 28

    CN 82 40 & C N8 26 0 Se ri es C om mu ni ca ti on s & Op ti on s 25 No tes 10002 Athena Omega:900M124U00.qxd 5/13/08 2:39 PM Page 28 ...

  • Omega Engineering CN8260 - page 29

    CN 82 40 & C N8 26 0 Se ri es C om mu ni ca ti on s & Op ti on s 26 No tes 10002 Athena Omega:900M124U00.qxd 5/13/08 2:39 PM Page 29 ...

  • Omega Engineering CN8260 - page 30

    FOR WARRANTY RETURNS, please have the following information available BEFORE contacting OMEGA: 1 . Purc hase Order number under which the product was PURCHA SED, 2. Model an d se ria l n umb er o f t he pro duc t un der war ranty , and 3. Repair instructions and/or specific problems relative to the product. FOR NON-WARRANTY REP AIRS, consult OME GA ...

  • Omega Engineering CN8260 - page 31

    W h e r e D o I F i nd E v e ry t h i n g I Ne e d f o r P r o c e s s Me a s u r e m e nt a n d C o nt r o l ? O ME G A … O f C ou r s e ! 900M124U00B TEMPERA TURE – Thermocouple, R TD & Thermistor Probes, Connectors, Panels & Assemblies – W ire: Thermocouple, R TD & Thermistor – Calibrators & Ice Point References – Recor ...

Fabricant Omega Engineering Catégorie Clock Radio

Les documents que nous recevons du fabricant de l'appareilOmega Engineering CN8260 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Omega Engineering
- manuels d’utilisations CN8260
- fiches produit Omega Engineering
- dépliants
- ou étiquettes-énergie Omega Engineering CN8260
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Omega Engineering CN8260.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Omega Engineering CN8260, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Omega Engineering CN8260. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Omega Engineering CN8260.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Omega Engineering CN8260, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Omega Engineering CN8260 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Omega Engineering CN8260.

Le manuel d’utilisation complet Omega Engineering, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Omega Engineering CN8260 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Omega Engineering CN8260, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lOmega Engineering CN8260 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Omega Engineering CN8260 - qui devraient nous aider dans les premières étapes lors de l'utilisation Omega Engineering CN8260
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Omega Engineering CN8260
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Omega Engineering CN8260 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Omega Engineering CN8260?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Omega Engineering CN8260, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Omega Engineering CN8260 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)