    FieldPoint ™ FP-1000 and FP-1001 RS-232/RS-485 Network Module User Manual FieldPoint FP-1000/FP-1001 User Manual July 1997 Edition Part Number 321631A-01 © Copyright 1997 National Instruments Corporation. All rights reserved. ...

  • National Instruments FP-1001 - page 2

    support@ natinst. com E-mail: in fo@natin st.com FTP Site: ftp.na tinst.com Web Address: http://www.n atinst.co m BBS United States: ( 512 ) 794-54 22 BBS United Kingd om: 016 35 551422 BBS Fra nce : 01 48 65 1 5 5 9 (512) 4 18- 111 1 Tel: (512) 795-82 48 Fax: (512 ) 794-567 8 Australia 03 9879 5166, Austria 0662 45 79 90 0, Belgium 02 757 00 2 0, ...

  • National Instruments FP-1001 - page 3

    Important Information Warranty The FieldPoi nt modules ar e warranted agains t defects in m aterials and wo rkmanship f or a period of o ne year from th e date of shipment, as evidenced by receipts or other documentation. Nation al Instruments will, at its option, repair or replace equipment that proves to be defective during the warranty period. T ...

  • National Instruments FP-1001 - page 4

    © Nat ional Instru ments Corpor ation v FieldPoint FP-1000/FP -1001 User Manua l Table of Cont ents About This M anual How to Use This Manual Set .............. ................. ................. ................. ................. ...... ix Organization of This Manual .............. ................. ................. ................. ......... ...

  • National Instruments FP-1001 - page 5

    T able of Contents FieldPoint FP-1000/F P-1001 Us er Manu al vi © Natio nal Inst rument s Corporati on SnapShot Feature ................... ................. ................. ................. ................. ................. .. 3-2 Programmable Power- Up State .......................... ................. ................ ................. ... ...

  • National Instruments FP-1001 - page 6

    T able of Contents © Nat ional Instru ments Corpor ation vii FieldPoint FP-1000/FP -1001 User Manua l Figure 2-8. RS-485 Co nnector Pinout for the FP-10 00 and FP-1001 ...................... 2-7 Figure 2-9. Terminating RS-48 5 Using the Combicon Adapter ........................ ...... 2-8 Figure 2- 10. Typical S ignal Connecti ons for Host Co mput ...

  • National Instruments FP-1001 - page 7

    © National Instruments Corporat ion ix Fi el dP oi nt FP -1 00 0 /F P-1 0 01 Us er M a nu al About This Manual This manu al describe s how to install and use th e FieldPoint FP-100 0 and FP-1001 ne twork modules. How to Use This Manual Set FieldPoint User Manual Network Connection, Hardware Configuration, and Feature Set Description Command Syntax ...

  • National Instruments FP-1001 - page 8

    About This Ma nual Fiel dPoint FP-1 000/FP -100 1 Use r Manua l x © Natio nal Inst rument s Corporati on Organization of This Manual This ma nual is orga nize d a s f ollow s: • Chapter 1, FP -1000 an d FP -1001 Ne twork Module Ov erv iew , provides a n ove rview of the FieldP oint networ k m odules. • Chapter 2, Installation and Configu ratio ...

  • National Instruments FP-1001 - page 9

    About This Ma nual © National Instruments Corporat ion xi Fi el dP oi nt FP -1 00 0/ F P-1 0 01 Us er M a nu al italic Italic text denotes emphasis, a cross refer ence, or an introduction to a key conce pt. T his font also deno tes text fr om which y ou supp ly the appropria te w ord or v alue, as in Wind ows 3 . x . itali c monos pace Italic text ...

  • National Instruments FP-1001 - page 10

    © National Instruments Corporat ion 1-1 Fi el dP oi nt FP -1 00 0 /F P-1 0 01 Us er M a nu al Chapter 1 FP-1000 and FP-1001 Network Module Overview This c hapter p rovid es a n o vervie w of the Fiel dPoint netwo rk mo dules. The FP-1000 FieldPoint network mod ule connects an industria l RS-232 network to Fie ldPoint I/O m odu les. T he FP- 1001 F ...

  • National Instruments FP-1001 - page 11

    Chapter 1 F P-1000 and FP -1001 Networ k Module Ov ervie w Fiel dPoint FP-1 000/FP -100 1 Use r Manua l 1- 2 © Natio nal Inst rument s Corporati on FP-1001 Connects to RS-485 The FP-10 01 FieldPo int ne twork m odu le conne cts direc tly to an RS-485 adap ter card th at is installed in your host compute r. Since RS-485 is inh eren tly a m ultidrop ...

  • National Instruments FP-1001 - page 12

    © National Instruments Corporat ion 2-1 Fi el dP oi nt FP -1 00 0 /F P-1 0 01 Us er M a nu al Chapter 2 Installation and Configuration This cha pter d escribe s how to instal l and co nfig ure y our Fie ldPoint network mo dule, conne ct it to an RS-232 or RS-485 netw ork, and connec t power to the ne twork mo dule. Installing the Network Module Th ...

  • National Instruments FP-1001 - page 13

    Chapter 2 Ins tallation an d Configuration Fiel dPoint FP-1 000/FP -100 1 Use r Manua l 2- 2 © Natio nal Inst rument s Corporati on 3. Slide the network modu le to the desir ed po sition o n the D IN rail. After the module is in position, push the rail snap into the lo cked position to lock the module in place on the DIN rail, as shown in Figure 2 ...

  • National Instruments FP-1001 - page 14

    Chap ter 2 Insta llation and C onfiguratio n © National Instruments Corporat ion 2-3 Fi el dP oi nt FP -1 00 0 /F P-1 0 01 Us er M a nu al 3. Attach the term inal ba se to the network m odule b y firmly mating the lo cal bus co nnectors. 4. T o add more terminal bases, install them on the rail and mate their local bus connect ors together. 5. Plac ...

  • National Instruments FP-1001 - page 15

    Chapter 2 Ins tallation an d Configuration Fiel dPoint FP-1 000/FP -100 1 Use r Manua l 2- 4 © Natio nal Inst rument s Corporati on Figur e 2-5. Host Computer Co nnected to One FP-1000 an d Two FP-1001 Network Modu les Connecting the FP-1001 to the Network This section describe s the network co nfigurations pos sible with the FP-1001 FieldPo int n ...

  • National Instruments FP-1001 - page 16

    Chap ter 2 Insta llation and C onfiguratio n © National Instruments Corporat ion 2-5 Fi el dP oi nt FP -1 00 0 /F P-1 0 01 Us er M a nu al Figu re 2-6 . Host Computer C onnected t o Three FP-1001 Net work Modul es The multidrop topology used in the networking con figurations pro vides protection ag ainst power fa ilures a t ind ividual Fie ldPoint ...

  • National Instruments FP-1001 - page 17

    Chapter 2 Ins tallation an d Configuration Fiel dPoint FP-1 000/FP -100 1 Use r Manua l 2- 6 © Natio nal Inst rument s Corporati on Both serial interf aces are sel f-configured to use the f ollowing parame ters: 1 Start Bit, 8 Data Bits, 1 Stop Bit, No Pa rity The supp orte d baud ra tes are 30 0, 1200, 24 00, 9600 , 192 00, 38 400, 57600, a nd 11 ...

  • National Instruments FP-1001 - page 18

    Chap ter 2 Insta llation and C onfiguratio n © National Instruments Corporat ion 2-7 Fi el dP oi nt FP -1 00 0 /F P-1 0 01 Us er M a nu al The FP-1000 does not use RS-232 har dware handshaking, but it still asserts the RTS and DSR signals for hos t computers o r s oftware that may re quir e th es e signa ls. A ho st c omputer tha t d oe s n ot u s ...

  • National Instruments FP-1001 - page 19

    Chapter 2 Ins tallation an d Configuration Fiel dPoint FP-1 000/FP -100 1 Use r Manua l 2- 8 © Natio nal Inst rument s Corporati on Figu re 2- 9. Termin ating R S-485 Using the Comb icon Ada pter An RS- 485 ne twork also nee ds bias ing r esisto rs to pr otect the devi ces on the network against noise du ring intervals when no RS- 485 drivers are ...

  • National Instruments FP-1001 - page 20

    Chap ter 2 Insta llation and C onfiguratio n © National Instruments Corporat ion 2-9 Fi el dP oi nt FP -1 00 0 /F P-1 0 01 Us er M a nu al Figur e 2-11. Typical Signal Connec tions for Host Co mputer Co nnected to Mult iple FP-1 001 Networ k Module s Configuring the Network Module Figure 2-12 shows the 8-position sw itch on the FP-1000 and FP-1 00 ...

  • National Instruments FP-1001 - page 21

    Chapter 2 Ins tallation an d Configuration Fiel dPoint FP-1 000/FP -100 1 Use r Manua l 2-10 © Natio nal Inst rument s Corporati on Follow these steps to set the address and b aud rate for your network module. 1. Choose and set a network address . Refer to the following section, Setting th e Netw ork Address , fo r more info rmati on. 2. Choose an ...

  • National Instruments FP-1001 - page 22

    Chap ter 2 Insta llation and C onfiguratio n © National Instruments Corporat ion 2-11 F ie ld Po in t F P- 10 00 /F P- 10 01 Us er M anu a l Tabl e 2-1. Net work Address Sw itch Setti ngs for the FP-100 0 and FP-1001 Network Mod ules Switch Positions 1 - 5 Network Module Address (Decimal) Switch Positions 1 - 5 Network M odule Address (Decimal) 0 ...

  • National Instruments FP-1001 - page 23

    Chapter 2 Ins tallation an d Configuration Fiel dPoint FP-1 000/FP -100 1 Use r Manua l 2-12 © Natio nal Inst rument s Corporati on Setting the Baud Rate Switches 6-8 set the network module baud rate. Table 2-2 shows the switch positions and the corres ponding netwo rk baud rates of the network mo dule. Note : If you are connecting more than one n ...

  • National Instruments FP-1001 - page 24

    Chap ter 2 Insta llation and C onfiguratio n © National Instruments Corporat ion 2-13 F ie ld Po in t F P- 10 00 /F P- 10 01 Us er M anu a l Figur e 2-13. FP-1 000 an d FP-1001 P ower Con nector Pi nout The two terminals labeled V are internally connected on the network module, a s are the two t erminals labeled C. Power must be appl ied to one V ...

  • National Instruments FP-1001 - page 25

    © National Instruments Corporat ion 3-1 Fi el dP oi nt FP -1 00 0 /F P-1 0 01 Us er M a nu al Chapter 3 Feature Set Description This cha pter d escribe s th e fe atu re set f or the FP- 1000 a nd FP-1001 network mo dules. Both the FP-1 000 and FP-1 001 ha ve a n ide ntical feat ure set, so this chap ter u ses the term network module to refer to ei ...

  • National Instruments FP-1001 - page 26

    Chapter 3 F eature Set De scription Fiel dPoint FP-1 000/FP -100 1 Use r Manua l 3- 2 © Natio nal Inst rument s Corporati on • Wat chdog ena bled/disa bled sta tus for each I/O modul e. • Watchdog time out value for the bank. Note : Each bank has only one watchdog timeout value that is common for all the modu les in th at bank . In addit ion, ...

  • National Instruments FP-1001 - page 27

    Chap ter 3 Feat ure Set Desc riptio n © National Instruments Corporat ion 3-3 Fi el dP oi nt FP -1 00 0 /F P-1 0 01 Us er M a nu al If you ha ve enabled the Sn apShot featur e, the network module restor es the stored settings to all I/O modules and chann els in the bank every time you p ower u p, un til you disable the Sn ap Shot fe ature. If the ...

  • National Instruments FP-1001 - page 28

    Chapter 3 F eature Set De scription Fiel dPoint FP-1 000/FP -100 1 Use r Manua l 3- 4 © Natio nal Inst rument s Corporati on • Attribute a nd range settings of each channe l. • Output values of each chan nel. • Wat chdog data value of each chan nel. See the Network W atchdog Timer section in this chapter for more information. • Watchdog da ...

  • National Instruments FP-1001 - page 29

    Chap ter 3 Feat ure Set Desc riptio n © National Instruments Corporat ion 3-5 Fi el dP oi nt FP -1 00 0 /F P-1 0 01 Us er M a nu al HotPnP During Power-Up Upon power- up, the netwo rk module automatically uploa ds an electronic data sheet (E DS) from each I/O modu le in its bank. The network m odule then configure s each I/O mo dule in the bank to ...

  • National Instruments FP-1001 - page 30

    Chapter 3 F eature Set De scription Fiel dPoint FP-1 000/FP -100 1 Use r Manua l 3- 6 © Natio nal Inst rument s Corporati on If the replacement module is incompatible with the one that was removed, the network modu le looks at the information stored in the SnapShot . If t he SnapShot is enab led and the repla cement modu le is compatible with the ...

  • National Instruments FP-1001 - page 31

    Chap ter 3 Feat ure Set Desc riptio n © National Instruments Corporat ion 3-7 Fi el dP oi nt FP -1 00 0 /F P-1 0 01 Us er M a nu al Power-On Self Test (POST) The power-on se lf test (POST) is a test suite that the network module perform s at po w er up to ve rify its ow n ope rationa l statu s. The test is non-invasive a nd therefore does not affe ...

  • National Instruments FP-1001 - page 32

    Chapter 3 F eature Set De scription Fiel dPoint FP-1 000/FP -100 1 Use r Manua l 3- 8 © Natio nal Inst rument s Corporati on The ye llo w NETWORK LED is lit during transmissions from the host comput er on the network . T his LE D indicates that the n etwork module is receiving from the network, and that the communication wires to it are not br oke ...

  • National Instruments FP-1001 - page 33

    © National Instruments Corporat ion 4-1 Fi el dP oi nt FP -1 00 0 /F P-1 0 01 Us er M a nu al Chapter 4 Using the FieldPoint Software This ch apter de scribes how to use the Fie ldPoint hardwar e with variou s servers a nd software packages. FieldPoint Software Overview Your FieldPoint softwar e consists of three parts: the FieldPoi nt Explorer, t ...

  • National Instruments FP-1001 - page 34

    Chapter 4 Us ing the FieldPoint Software Fiel dPoint FP-1 000/FP -100 1 Use r Manua l 4- 2 © Natio nal Inst rument s Corporati on Using the FieldPoint Explorer You can use the FieldPoin t Explorer to accomp lish the following tasks: • Configure the characteristic s and hardwa re of a FieldPoint devic e network • Configure the ta g n ame spa ce ...

  • National Instruments FP-1001 - page 35

    Chapter 4 U sing the Fie ldPoint Software © National Instruments Corporat ion 4-3 Fi el dP oi nt FP -1 00 0 /F P-1 0 01 Us er M a nu al Using the FieldPoint Server with LabVIEW To use the FieldPo int se rv er f rom L ab VIEW , first co nfig ure and test your FieldPoint de vice network fr om FieldPoint Explorer . After you are satisfied with the c ...

  • National Instruments FP-1001 - page 36

    Chapter 4 Us ing the FieldPoint Software Fiel dPoint FP-1 000/FP -100 1 Use r Manua l 4- 4 © Natio nal Inst rument s Corporati on Using the FieldPoint Lookout Driver The FieldPoint L ookout driver uses the configura tion information in the IAK file c rea ted by the Fie ldPoint Ex plorer fo r its ow n configu ra tion. The tag n ame s use d wi th t ...

  • National Instruments FP-1001 - page 37

    © Nat ional Instru ments Corpor ation A-1 FieldPoint FP-1000/FP -1001 User Manua l Appendix A Specifications This append ix describes the specifica tions of the FP-1000 and FP-10 01 network mo dules. All FieldPoint network mo dules undergo ex tensive testing for operating under rugged environmental conditi ons that exist in industrial applications ...

  • National Instruments FP-1001 - page 38

    Appendix A S pecification s FieldPoint FP-1000/F P-1001 Us er Manu al A-2 © Natio nal Inst rument s Corporati on RS-48 5 Isol ation ......... ...... ..... ...... ...... 2 500 Vrm s break down, 250 Vrm s o pe rat iona l Environment Opera ting T em pera t ure ... .. ..... .. .. .... .. .. . –40° C to +70 ° C Storage T empe rat ure .... .... .... ...

  • National Instruments FP-1001 - page 39

    © Nat ional Instru ments Corpor ation B-1 FieldPoint FP-1000/FP -1001 User Manua l Appendix B Customer Communication For yo ur convenience, t his append ix contain s forms t o help you gather the inf ormatio n necessary to help us solve you r technical problems and a form you can use to commen t on the pro duct documentation. When you contact us, ...

  • National Instruments FP-1001 - page 40

    Fax-on- Demand is a 2 4-hour inf ormation retr ieval syst em containing a library of d ocuments on a wide range of tech nical information. You can access Fax-on-Demand fro m a touch-tone telephone at (512 ) 418-1111 . You can submit technical su pport questions to the applications enginee ring team through e-mail at the Internet address listed belo ...

  • National Instruments FP-1001 - page 41

    FieldPoint System Configuration Form Record the settings and revisions of your h ardware and software on the line to the right of each item. Complete a new copy of this form each time you revi se your software or hardware conf iguration, and use this form as a reference for y our current configu ration. Completing this form accu rately also helps u ...

  • National Instruments FP-1001 - page 42

    FieldPoint Banks Please us e one page per Fi eldPoint bank. Network mo dule ____ ___________ ________ _________ _____ Firm ware revision __________ __ Addr ess ______ _________ ________ _________ ________ __ Baud rat e _______ _________ __ Circle the state of the following items when y our problem occur s: L E Ds P OW ER : ON / OF F NETWORK : ON/OF ...

  • National Instruments FP-1001 - page 43

    Technical Support Form Photocopy this fo rm and u pdate it each time y ou make ch anges to you r software or h ardware, and use the completed copy of this form as a reference for your current configuratio n. Completing this form accurately befor e contacting National Instruments for technical su pport helps our applications engineers answer your qu ...

  • National Instruments FP-1001 - page 44

    Documentation Comment Form National Instrum ents encourages you to commen t on the do cumentatio n supplie d with our prod ucts. This information hel ps us provide quality pro duc ts to meet your needs. Title: FieldPoint ™ FP-1 000 and FP-10 01 RS-232/RS -485 Netwo rk Module User Manual Edition Date: July 199 7 Part Number: 321631A-01 Please comm ...

  • National Instruments FP-1001 - page 45

    © Nat ional Instru ments Corpor ation G-1 FieldPoint FP -1000/FP -1001 Use r Manual Glossary % perce nt ° degr ees 0x precedes a hexade cimal number Ω ohms B bytes bank The co mbin ation of o ne Field Point n etwor k m odule an d o ne o r m ore terminal bases and I/O modules. Cc e l s i u s DSR Data Set Ready EDS electronic data sheet EMI elect ...

  • National Instruments FP-1001 - page 46

    Gloss ar y FieldPoint FP-1000/F P-1001 Us er Manu al G-2 © Natio nal Inst rument s Corporati on I/O input/output IEC I nternational Electr otechnical Commission in. inches LED Light-emitting diode OPC OLE f or Proce ss C ontrol POST power-on self te st RAM random- access memo ry RTS Request to Send VV o l t s VDC Vo lts dire ct curren t ...

  • National Instruments FP-1001 - page 47

    © Natio nal Inst rument s Corpora tion I-1 Fi el d Po in t FP - 10 00 / FP -1 0 01 U se r M an ua l Index A ACCESS LED, 3-7 addresses, setting address and baud rate, 2 -9 to 2- 10 netwo rk address , 2-10 to 2-11 unique addr ess for each module (n ote), 2-10 B banks. See FieldP oint bank s. baud rate address and baud rate s witch se ttings (figur e ...

  • National Instruments FP-1001 - page 48

    Index Fiel dPoi nt FP- 1000/ FP-1 001 U ser Ma nual I-2 © N ati onal Ins trumen ts Corpo rati on F fax an d telephone s upport, B- 2 fax-o n-demand suppo rt, B-2 feature s et descript ion, 3-1 t o 3-8 high-speed local b us, 3-1 HotPn P (Hot P lug and Play), 3- 4 to 3-6 LED in dicators, 3 -7 to 3- 8 netwo rk watch dog timer, 3 -1 to 3- 2 power-on s ...

  • National Instruments FP-1001 - page 49

    Inde x © Natio nal Inst rument s Corpora tion I- 3 Fi el dP o in t F P -1 00 0 / FP -1 0 01 U se r M an ua l L LabVI E W softwa r e, usin g with Fi eldPoint Server, 4-3 LabWindows/CVI software, using with FieldPoi nt Server, 4-3 LED in dicators, 3 -7 to 3- 8 local bus, high-speed , 3-1 M manual. See documentation. N network address, s etting, 2 -1 ...

  • National Instruments FP-1001 - page 50

    Index Fiel dPoi nt FP- 1000/ FP-1 001 U ser Ma nual I-4 © N ati onal Ins trumen ts Corpo rati on T technical support, B -1 to B- 2 teleph one and fax sup por t , B-2 terminal base connection, 2 -2 to 2-3 termin ation and b iasing, R S-485 port s, 2-7 t o 2-9 W watchdog timer, 3-1 t o 3-2 ...

Fabricant National Instruments Catégorie Network Card

Les documents que nous recevons du fabricant de l'appareilNational Instruments FP-1001 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques National Instruments
- manuels d’utilisations FP-1001
- fiches produit National Instruments
- dépliants
- ou étiquettes-énergie National Instruments FP-1001
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation National Instruments FP-1001.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation National Instruments FP-1001, manuels d’entretien, brefs manuels ou manuels de l’utilisateur National Instruments FP-1001. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit National Instruments FP-1001.

Manuel d’utilisation complet de l’appareil National Instruments FP-1001, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser National Instruments FP-1001 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs National Instruments FP-1001.

Le manuel d’utilisation complet National Instruments, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel National Instruments FP-1001 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières National Instruments FP-1001, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lNational Instruments FP-1001 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil National Instruments FP-1001 - qui devraient nous aider dans les premières étapes lors de l'utilisation National Instruments FP-1001
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de National Instruments FP-1001
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service National Instruments FP-1001 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de National Instruments FP-1001?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec National Instruments FP-1001, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec National Instruments FP-1001 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)