Manuel d’utilisation Generac Power Systems OG 2697

20 pages 1.2 mb
Télécharger

Aller à la page of 20

Summary
  • Generac Power Systems OG 2697 - page 1

    Air -Cooled Generators Distributed Load Center Transfer Switch GENERA TOR INST ALLA TION GUIDELINES OG 2697 ...

  • Generac Power Systems OG 2697 - page 2

    1 Study the SAFETY RULES in the Owner ’ s Manual carefully before installing, operating or servicing any equipment. Use this guide ONL Y in conjunction with the Owner ’ s Manual and Installation Guide shipped with the generator . The generator can operate safely , efciently and reliably only if it is properly installed, operated and maintain ...

  • Generac Power Systems OG 2697 - page 3

    2 This exhaust system must be installed properly , in strict compliance with applicable codes and standards. Keep hands, feet, clothing, etc., away from drive belts, fans and other moving or hot parts. Never remove any drive belt or fan guard while the unit is operating. Adequate, unobstructed ow of cooling and ventilating air is critical to pre ...

  • Generac Power Systems OG 2697 - page 4

    3 NFP A 101, LIFE SAFETY CODE NFP A 110, ST ANDARD FOR EMERGENCY AND ST ANDBY POWER SYSTEMS NFP A 220, ST ANDARD TYPES OF BUILDING CONSTRUCTION NOTE: It is essential to use the latest version of any standard to ensure that the generator and its accessories comply with all the applicable standards and local codes. Other Published Standards In additi ...

  • Generac Power Systems OG 2697 - page 5

    4 Do not open or mutilate the battery . Released electrolyte can be toxic and harmful to the skin and eyes. The battery represents a risk of high short-circuit current. When working on the battery , always remove watches, rings or other metal objects, and only use tools that have insulated handles. V ented Batteries The electrolyte is a diluted sul ...

  • Generac Power Systems OG 2697 - page 6

    5 Locate the mounting pad as close as possible to the transfer switch and fuel supply . Leave adequate room around the pad for service access (check local code) and place the pad high enough to keep rising water from reaching the generator . Choose an open space that will provide adequate and unobstructed airow . Place the unit so air vents won? ...

  • Generac Power Systems OG 2697 - page 7

    6 Make sure the lifting equipment you’ll be using has sufcient capacity to safely handle the weight of the generator . Use nylon lifting straps and connect them to the lifting eyes on each corner of the base frame to avoid damaging the enclosure. Set the generator onto the pad so that the gravel bed extends several inches beyond the generator ...

  • Generac Power Systems OG 2697 - page 8

    7 Check the engine oil, and if necessary , add enough of the recommended oil to bring the level up to the FULL mark on the dipstick. Be careful not to overll the crankcase. The generator was congured for natural gas operation at the factory . Switching over to LP vapor is a simple procedure. On models with the V -T win engine, simply ip th ...

  • Generac Power Systems OG 2697 - page 9

    8 Replace the fuel hose and clamp. Then reconnect the wires to the solenoid. Finally , insert the plastic plug that came with the generator into the hole on the bottom of the air cleaner base. Both natural gas and LP vapor are highly volatile substances, so strict adherence to all safety procedures, codes, standards and regulations is essential. Ga ...

  • Generac Power Systems OG 2697 - page 10

    9 When connecting the gas line to the generator , use a short section of UL Listed or AGA- approved exible fuel line in accordance with local regulations. The purpose of the exible fuel line is to ensure that vibration from the generator does not cause a gas leak at one of the connection points, so it’ s important that the line be installed ...

  • Generac Power Systems OG 2697 - page 11

    10 Drill a 1¾ inch hole and feed the conduit through the hole. Remove the knockout in the back of the connection box, feed the wires through the back of the box and secure the conduit with the lock nut. Seal the hole with silicone caulk. Don’t for get to caulk the hole inside the house as well. Mount the connection box so that it completely cove ...

  • Generac Power Systems OG 2697 - page 12

    1 1 Before beginning any installation, make sure power is shut OFF to the main distribution panel and carefully read the Installation Guide that came with your transfer switch. The distributed load center switch must be mounted close enough to the main distribution panel to accommodate the two-foot, pre-wired conduit. Make sure no water or corrosiv ...

  • Generac Power Systems OG 2697 - page 13

    12 When three-conductor wiring is used, two 120 volt circuits will often share the same neu tral wire. T o avoid overloading the neutral, you should either move BOTH of the circuits that share the neutral or don’t move either of them. When moving two circuits with a shared neutral, they should be connected to adjacent positions (one above the oth ...

  • Generac Power Systems OG 2697 - page 14

    13 Install a 2-pole breaker in the distribution panel to protect the transfer switch. The required Amp rating of the breaker depends on which transfer switch you’re using, so refer to the Installation Guide before purchasing the breaker . Install the breaker in two adjacent empty slots (one above the other) in the main panel. When all emergency c ...

  • Generac Power Systems OG 2697 - page 15

    14 Locate the transfer handle and insert the metal end into the slot in the main contactor assembly . Pull the handle DOWN to move the main contacts to the standby power (generator) position. NEVER OPERA TE THE TRANSFER SWITCH MANUALL Y WHEN LOADS ARE CONNECTED. Put the generator ’ s mode switch in MANUAL to start the engine. Allow the engine to ...

  • Generac Power Systems OG 2697 - page 16

    15 Use the transfer handle to move the main contacts in the transfer switch to the UP (utility) position. Switch the 2-pole breaker ON in the distribution panel. Now switch the generator ’ s main breaker ON and put the mode switch in AUTO. Shut OFF utility power and make sure the generator starts automatically . If everything worked properly , sw ...

  • Generac Power Systems OG 2697 - page 17

    After the engine has completed its cool down cycle and shut down, shut OFF utility power again. When the generator is supplying power to the transfer switch, move the breakers in the switch to the ON position one at a time until the generator has accepted the entire emergency load. W ith the generator carrying the entire emer gency load, re-check g ...

  • Generac Power Systems OG 2697 - page 18

    Shut OFF utility power again. The generator should start and the entire emergency load should transfer to the generator . Close the main breaker to restore utility power and allow the engine to cool down and shut itself OFF . W ith the mode switch in AUTO, press the EXERCISER switch. Hold it down for at least 10 seconds and release. The generator s ...

  • Generac Power Systems OG 2697 - page 19

    Notes 18 ...

  • Generac Power Systems OG 2697 - page 20

    Every installation has its own unique set of circumstances and requirements. This booklet provides guidelines for basic installations only and is not intended to cover all applications. If you have any questions or concerns after carefully reading all documentation received with the equipment, contact your local dealer for assistance. Part# 0G2697 ...

Fabricant Generac Power Systems Catégorie Fan

Les documents que nous recevons du fabricant de l'appareilGenerac Power Systems OG 2697 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Generac Power Systems
- manuels d’utilisations OG 2697
- fiches produit Generac Power Systems
- dépliants
- ou étiquettes-énergie Generac Power Systems OG 2697
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Generac Power Systems OG 2697.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Generac Power Systems OG 2697, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Generac Power Systems OG 2697. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Generac Power Systems OG 2697.

Manuel d’utilisation complet de l’appareil Generac Power Systems OG 2697, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Generac Power Systems OG 2697 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Generac Power Systems OG 2697.

Le manuel d’utilisation complet Generac Power Systems, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Generac Power Systems OG 2697 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Generac Power Systems OG 2697, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lGenerac Power Systems OG 2697 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Generac Power Systems OG 2697 - qui devraient nous aider dans les premières étapes lors de l'utilisation Generac Power Systems OG 2697
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Generac Power Systems OG 2697
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Generac Power Systems OG 2697 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Generac Power Systems OG 2697?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Generac Power Systems OG 2697, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Generac Power Systems OG 2697 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)