    1 PRINTED IN THE U.S.A. 0308 www .sears.com P ART NO. 185249-002 Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A C3 T echnology ® Gas W ater Heaters meet the new ANSI Z21.10.1 standard that deals with the accidental or unintended ignition of fl ammable vapors, such as those emitted by gasoline. Owner ’ s Manual FOR POT ABLE W A TER HEA ...

  • Kenmore THE ECONOMIZER 153.33204 - page 2

    2 SAFE INST ALLA TION, USE AND SERVICE Y our safety and the safety of others is extremely important in the installation, use and servicing of this water heater . Many safety-related messages and instructions have been provided in this manual and on your own water heater to warn you and others of a potential injury hazard. Read and obey all safety m ...

  • Kenmore THE ECONOMIZER 153.33204 - page 3

    3 SAFETY PRECAUTIONS ...

  • Kenmore THE ECONOMIZER 153.33204 - page 4

    4 SAFE INST ALLA TION, USE AND SERVICE............................................................................................. ......................................... 2 SAFETY PRECAUTIONS ........................................................................................................................................................... ...

  • Kenmore THE ECONOMIZER 153.33204 - page 5

    5 T ANK RECOVER Y MINIMUM CAP ACITY INPUT RA TE GALS. VENT PIPE DIAMETER DIMENSIONS IN MODEL IN GALS. TYPE OF RA TE PER HOUR INCHES INCHES INCHES (mm) HEIGHT NUMBER (L TRS) GAS (Btu/hr) @ 90°F RISE (mm) (mm) TO JACKET T OP 153.332040 40 (151) NA TURAL 40,000 44 2 (51) 18 1/2 (470) 55 (1,397) 153.332050 50 (189) NA TURAL 40,000 44 2 (51) 20 (508) 5 ...

  • Kenmore THE ECONOMIZER 153.33204 - page 6

    6 For all side wall terminated, horizontally vented power vent, direct vent, and power direct vent gas fueled water heaters insta lled in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated b y the Commonwealth and where the side wall exhaust vent termination is less than seven ...

  • Kenmore THE ECONOMIZER 153.33204 - page 7

    7 Materials Needed T o simplify the installation Sears has available the installation parts shown below . Y ou may or may not need all of these materials, depending on your type of installation. W A TER HEA TER INST ALLA TION KIT WITH FLEXIBLE CONNECTORS FOR 3/4” (19.05 mm) OR 1/2” (12.7 mm) THREADED OR COPPER PLUMBING AND FLEXIBLE GAS CONNECTO ...

  • Kenmore THE ECONOMIZER 153.33204 - page 8

    8 TYPICAL INST ALLA TION GET TO KNOW YOUR W A TER HEA TER - GAS MODELS A V ent Pipe–Exhaust B V ent T erminal C V ent Adapter-Rubber Boot D Blower Assembly E Cold W ater Inlet F Inlet W ater Shut-off V alve G Union H Inlet Dip T ube J Anode** FIGURE 1. K Hot W ater Outlet L Outlet Receptacle (1 15 V AC) M T emperature-Pressure Relief V alve N Flu ...

  • Kenmore THE ECONOMIZER 153.33204 - page 9

    9 1. T urn “OFF” the gas supply to the water heater . If the main gas line Shut-of f valve serving all gas appliances is used, also shut “OFF” the gas at each appliance. Leave all gas appliances shut “OFF” until the water heater installation is completed, see Figures 2 and 3. 2. T urn “OFF” the water supply to the water heater at th ...

  • Kenmore THE ECONOMIZER 153.33204 - page 10

    10 F ACTS TO CONSIDER ABOUT THE LOCA TION Carefully choose an indoor location for the new water heater , because the placement is a very important consideration for the safety of the occupants in the building and for the most economical use of the appliance. This water heater is not for use in manufactured (mobile) homes or outdoor installation. Wh ...

  • Kenmore THE ECONOMIZER 153.33204 - page 11

    11 and 12” (30.5 cm) from the top. (Standard clearance.) If clearances stated on the heater differ from standard clearances, install water heater according to clearances stated on the heater . Adequate clearance for servicing this appliance should be considered before installation, such as changing the anodes, etc. A minimum clearance of 5” (12 ...

  • Kenmore THE ECONOMIZER 153.33204 - page 12

    12 Chemical vapor corrosion of the fl ue, blower assembly and vent system may occur if air for combustion contains certain chemical vapors. Spray can propellants, cleaning solvents, refrigerator and air conditioner refrigerants, swimming pool chemicals, calcium and sodium chloride, waxes, bleach and process chemicals are typical compounds which ar ...

  • Kenmore THE ECONOMIZER 153.33204 - page 13

    13 W A TER PIPING HOTTER W A TER CAN SCALD: W ater heaters are intended to produce hot water . Water heated to a temperature which will satisfy space heating, clothes washing, dish washing, cleaning and other sanitizing needs can scald and permanently injure you upon contact. Some people are more likely to be permanently injured by hot water than o ...

  • Kenmore THE ECONOMIZER 153.33204 - page 14

    14 INST ALLA TION COMPLETED USING INST ALLA TION KIT FIGURE 16. T & P V alve and Pipe Insulation (if supplied) Remove insulation for T & P valve and pipe connections from carton. FIGURE 17. Fit pipe insulation over the incoming cold water line and the hot water line. Make sure that the insulation is against the top cover of the heater . Fit ...

  • Kenmore THE ECONOMIZER 153.33204 - page 15

    15 The Discharge Pipe: • Shall not be smaller in size than the outlet pipe size of the valve, or have any reducing couplings or other restrictions. • Shall not be plugged or blocked. • Shall be of material listed for hot water distribution. • Shall be installed so as to allow complete drainage of both the temperature-pressure relief valve, ...

  • Kenmore THE ECONOMIZER 153.33204 - page 16

    16 The appliance and its gas connection must be leak tested before placing the appliance in operation. The appliance and its individual Shut-off valve shall be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 pound per square inch (3.5 kPa). It shall be isolated from the ga ...

  • Kenmore THE ECONOMIZER 153.33204 - page 17

    17 4. Make sure that the plastic tubing is still attached from the air pressure switch to the port on the blower housing. Make sure the plastic tubing is not folded anywhere between the pressure switch and the blower housing. 5. Make sure the ON/OFF switch is in the OFF position and that the outer harness is connected from the blower control box to ...

  • Kenmore THE ECONOMIZER 153.33204 - page 18

    18 VENT CONNECTIONS TO BLOWER ASSEMBL Y Figure 21 shows the optimal placement of the 2” to 3” or 3” to 4” reducer; however , the vent can be reduced at any point in the vent system as long as the maximum vent length is not exceeded. FIGURE 21. VENTING AND INST ALLA TION Plan the layout of the vent system from the vent termination to the wat ...

  • Kenmore THE ECONOMIZER 153.33204 - page 19

    19 VENTING The vent system must terminate so that proper clearances are maintained as cited in local codes or the current edition of the National Fuel Gas Code, ANSI Z223.1/NFP A 54, 7.3.4e and 7.8a,b, as follows: 1. The exit terminals of a mechanical vent system shall be not less than 7 feet (2.13 m) above grade when located adjacent to public wal ...

  • Kenmore THE ECONOMIZER 153.33204 - page 20

    20 FIGURE 23. This unit can vent through 2”, 3” or 4” nonmetallic pipe and fi ttings. The vent pipe installation can be started from either the blower discharge or the termination wall. Keep in mind the total vent system (pipe and elbows) when installing the vent system, see VENTING AND INST ALLA TION AND MAXIMUM VENT LENGTHS, page 17. FIGUR ...

  • Kenmore THE ECONOMIZER 153.33204 - page 21

    21 VENT PIPE PREP ARA TION 1. INITIAL PREP ARA TION A. Make sure the solvent cement you are planning to use is designed for the speci fi c application you are attempting. B. Know the physical and chemical characteristics and limitations of the PVC and CPVC piping materials that you are about to use. C. Know the reputation of your manufacturer and ...

  • Kenmore THE ECONOMIZER 153.33204 - page 22

    22 B. Deburring Use a knife, plastic pipe deburring tool, or fi le to remove burrs from the end of small diameter pipe. Be sure to remove all burrs from around the inside as well as the outside of the pipe. A slight chamfer (bevel) of about 10°-15° should be added to the end to permit easier insertion of the pipe into the end of the fi tting. F ...

  • Kenmore THE ECONOMIZER 153.33204 - page 23

    23 OPERA TING INSTRUCTIONS FLAMMABLE BEFORE OPERA TING: ENTIRE SYSTEM MUST BE FILLED WITH W A TER AND AIR PURGED FROM ALL LINES. A. B. C. D. WHA T T O DO IF YOU SMELL GAS: Do not try to light any appliance. Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. If you cannot reach your gas supp ...

  • Kenmore THE ECONOMIZER 153.33204 - page 24

    24 TEMPERA TURE REGULA TION Due to the nature of the typical gas water heater , the water temperature in certain situations may vary up to 30°F (16.7°C) higher or lower at the point of use such as, bathtubs, showers, sink, etc. It is recommended that lower water temperatures be used to avoid the risk of scalding. It is further recommended, in all ...

  • Kenmore THE ECONOMIZER 153.33204 - page 25

    25 FOR YOUR INFORMA TION ST ART UP CONDITIONS CONDENSA TE Whenever the water heater is fi lled with cold water , some condensate will form while the burner is on. A water heater may appear to be leaking when in fact the water is condensate. This usually happens when: a. A new water heater is fi lled with cold water for the fi rst time. b. Burnin ...

  • Kenmore THE ECONOMIZER 153.33204 - page 26

    26 STRANGE SOUNDS Possible noises due to expansion and contraction of some metal parts during periods of heat-up and cool-down do not necessarily represent harmful or dangerous conditions. Condensation causes sizzling and popping within the burner area during heating and cooling periods and should be considered normal. See “Condensate” in this ...

  • Kenmore THE ECONOMIZER 153.33204 - page 27

    27 At least once a year a visual inspection should be made of the main burner and the hot surface igniter assembly for proper fl ame characteristics and ignition sequences. This can be done by removing the Outer Door and viewing the main burner operation through the Viewport on the Inner Door , see Figure 1. The main burner should provide complete ...

  • Kenmore THE ECONOMIZER 153.33204 - page 28

    28 FIGURE 30. When checking the temperature-pressure relief valve operation, make sure that (1) no one is in front of or around the outlet of the temperature- pressure relief valve discharge line, and (2) that the water discharge will not cause any property damage, as the water may be extremely hot, see Figure 30. If after manually operating the va ...

  • Kenmore THE ECONOMIZER 153.33204 - page 29

    29 LEAKAGE CHECKPOINTS Read this manual fi rst. Then before checking the water heater make sure the gas supply has been turned “OFF”, and never turn the gas “ON” before the tank is completely full of water . Never use this water heater unless it is completely fi lled with water. T o prevent damage to the tank, the tank must be fi lled wi ...

  • Kenmore THE ECONOMIZER 153.33204 - page 30

    30 TROUBLESHOOTING GUIDELINES These guidelines should be used by a quali fi ed service agent. Call Sears Service at 1-800-4-MY -HOME ® (1-800-469-4663) for assistance. Inform the associate that this is a “Flammable V apor Ignition Resistant” Product. # LED ST A TUS PROBLEM SOLUTION 1 The gas control valve has sensed inadequate or no earth gro ...

  • Kenmore THE ECONOMIZER 153.33204 - page 31

    31 TROUBLESHOOTING GUIDELINES These guidelines should be used by a quali fi ed service agent. Call Sears Service at 1-800-4-MY -HOME ® (1-800-469-4663) for assistance. Inform the associate that this is a “Flammable V apor Ignition Resistant” Product. # LED ST A TUS PROBLEM SOLUTION 7 8 9 The gas control valve has detected a problem with the g ...

  • Kenmore THE ECONOMIZER 153.33204 - page 32

    32 These guidelines should be utilized by a quali fi ed service agent. When calling for service notify the service agent that this is a “Flammable V apor Ignition Resistant” Product. TROUBLESHOOTING GUIDELINES ...

  • Kenmore THE ECONOMIZER 153.33204 - page 33

    33 Model Numbers Key No. Part Description 153.332040 153.332050 153.332060 153.332070 1 Burner Assembly 9005938 9005939 9005943 9005944 2 Burner Head 9003385 9003385 9005948 9005948 3 Burner Ori fi ce 9005950(#32) 9005950(#32) 9003495(#50) 9003495(#50) 4 Burner T ube 9005951 9005952 9005954 9005955 5 HSI Ignition Assembly 9005958 9005958 9005958 9 ...

  • Kenmore THE ECONOMIZER 153.33204 - page 34

    34 NOTES: ...

  • Kenmore THE ECONOMIZER 153.33204 - page 35

    35 NOTES: ...

  • Kenmore THE ECONOMIZER 153.33204 - page 36

    36 6 YEAR LIMITED W ARRANTY ON W A TER HEA TER Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A. MASTER PROTECTION AGREEMENTS Congratulations on making a smart purchase. Y our new Kenmore ® product is designed and manufactured for years of dependable operation. But like all products, it may require preventive maintenance or repair from time ...

Fabricant Kenmore Catégorie Car Satellite TV System

Les documents que nous recevons du fabricant de l'appareilKenmore THE ECONOMIZER 153.33204 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Kenmore
- manuels d’utilisations THE ECONOMIZER 153.33204
- fiches produit Kenmore
- dépliants
- ou étiquettes-énergie Kenmore THE ECONOMIZER 153.33204
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Kenmore THE ECONOMIZER 153.33204.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Kenmore THE ECONOMIZER 153.33204, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Kenmore THE ECONOMIZER 153.33204. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Kenmore THE ECONOMIZER 153.33204.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Kenmore THE ECONOMIZER 153.33204, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Kenmore THE ECONOMIZER 153.33204 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Kenmore THE ECONOMIZER 153.33204.

Le manuel d’utilisation complet Kenmore, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Kenmore THE ECONOMIZER 153.33204 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Kenmore THE ECONOMIZER 153.33204, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lKenmore THE ECONOMIZER 153.33204 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Kenmore THE ECONOMIZER 153.33204 - qui devraient nous aider dans les premières étapes lors de l'utilisation Kenmore THE ECONOMIZER 153.33204
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Kenmore THE ECONOMIZER 153.33204
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Kenmore THE ECONOMIZER 153.33204 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Kenmore THE ECONOMIZER 153.33204?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Kenmore THE ECONOMIZER 153.33204, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Kenmore THE ECONOMIZER 153.33204 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)