Manuel d’utilisation ADT PowerSeries SCW9045-433

20 pages 3.54 mb
Télécharger

Aller à la page of 20

Summary
  • ADT PowerSeries SCW9045-433 - page 1

    User Guide Self Contained W ireless Alar m Sy stem v1 .0 W ARNING: This manual contains inf ormati on on limitations regarding product use and function and information on th e limitations as to liability of the manuf acturer . The entire manual should be carefully read. N11427 ...

  • ADT PowerSeries SCW9045-433 - page 2

    FCC COMPLIA NCE STATEMENT CAUTION: Changes or modifications not e xpressly approved by Dig- ital Security Controls could void you r authority to us e th is equip ment. This equipment has been tested and found to comply with the lim its for a Class B digital device, pursua nt to Part 15 of the FCC Rules. These limit s are designed to provide reasona ...

  • ADT PowerSeries SCW9045-433 - page 3

    i Table of Contents About You r Secu rity Sys tem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Fire Det ection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • ADT PowerSeries SCW9045-433 - page 4

    ii Reference Sheets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 System In formation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Access Cod es . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • ADT PowerSeries SCW9045-433 - page 5

    1 About Your Security System Y our Security Sy stem has been designed to provide you with the greatest po ssible flexibility and con- venience. Read this manual carefu lly and have your installer instru ct you on your system's operation and on which features have been implemented in your system. All users of this system should be equally instr ...

  • ADT PowerSeries SCW9045-433 - page 6

    2 Controls & Indicators IMPORT ANT NOTICE A security system cannot preve nt em ergencies. It is only intended to alert you and – if included – your central station of an emergency situation. Security systems are generally very reliable but they may not work under all conditions and they are not a subs titute for prudent security practices o ...

  • ADT PowerSeries SCW9045-433 - page 7

    3 Night Arming T o fully arm the system when it has been armed in Stay Mode, pr ess at the keypad. All inte- rior zones will now be armed except for devices pr ogrammed as Night Zones. Night zones ar e only armed in Aw ay mode, this pe rmits limited movement within the premises when the system is fully armed. Ens ure that your insta ller has pr ovi ...

  • ADT PowerSeries SCW9045-433 - page 8

    4 Remote Arming and Disarming The system can be armed and/or disarmed (if prog rammed by the installer) using a r emote control device (wireless key). When armi ng the system by using the Arm button on th e wireless key , the system will ac knowledge the comm and by soun ding a single bell squawk and when disarm ing using the Dis - arm button on th ...

  • ADT PowerSeries SCW9045-433 - page 9

    5 bypassed when arming your system. Zones cannot be bypassed once the system is armed. Bypassed zones ar e automatically canc elled each time the system is disarm ed and must be bypassed again, if requir ed, before the next arming. Bypassing Zones W ith the system disarmed. 1. Press to enter the function menu. The keypad will display “P ress  ...

  • ADT PowerSeries SCW9045-433 - page 10

    6 T o select a Bypass Group when arming the system: 1. Press , then your [access code] (if necessary). 2. Press . The next time the system is armed, the zones in this gr oup will be bypassed. 3. T o exit bypassing mode and return to the Ready state , press . NOTE: A Bypass Group is only recalled if the syst em is armed/disarmed after programming th ...

  • ADT PowerSeries SCW9045-433 - page 11

    7 Access Code Programming In addition to the Master Access Code, you can program up to 16 a dditional User Access codes. Pr ess , plus your Master Access Code, the armed ( ) indicator will tur n on. Enter the 2-digit nu mber to be programmed (i.e. 06 for user a ccess code 6; e nter 40 for t he Master Access Code) or use the keys to find the specifi ...

  • ADT PowerSeries SCW9045-433 - page 12

    8 Bell Squawk Attrib ute This attribute is used to determine whether an access code should generate an arming/disarming Bell Squawk upon entry of the code for Away arming. The Wireless Keys with access codes associated with them may generate Arming/Disarming Bell squawks. If desire d, this option may be used with codes that are manually enter ed. P ...

  • ADT PowerSeries SCW9045-433 - page 13

    9 2. Use the keys to scr oll to Buzzer Contr ol. 3. Ther e are 21 di ffer ent levels, use the keys to scr oll to the desir ed level. Viewing the Event Buff er The event buffer will show you a list of the last 128 events that have occurred on your system. 1. Press [Master Code]. 2. T o select Event Buffer viewing, pr ess . 3. The keypad will displa ...

  • ADT PowerSeries SCW9045-433 - page 14

    10 Reference Sheets Fill out the following information for future re ference and store this guide in a safe place. System Inf ormation Enabled?  [F] FIRE  [A] AUXILIARY  [P ] PANIC For Service Centra l Station Inf orm ation Account#: ___________________ Telephone#: __________________ Installer Information: Company: ___________________ Tele ...

  • ADT PowerSeries SCW9045-433 - page 15

    11 Sensor / Zone Inf ormation Sensor Protected Ar ea Senso r T ype Sensor Protected Ar ea Se nsor T ype 01 18 02 19 03 20 04 21 05 22 06 23 07 24 08 25 09 26 10 27 11 28 12 29 13 30 14 31 15 32 16 33 17 34 ...

  • ADT PowerSeries SCW9045-433 - page 16

    12 Guidelines for Locating Smoke Detectors Research has shown that all hostile fires in homes generate smoke to a greater or lesser extent. Experiments with typica l fires in homes indicate that detectable q uantities of smoke precede detectable levels o f heat i n mo st cases. For these reasons, smoke alarms should be installed out- side of each s ...

  • ADT PowerSeries SCW9045-433 - page 17

    13 Household Fire Safety Audit Read this s ection carefu lly for impo rtant information about fire safety. Most fires occur in the home. To minimize this danger, we re commend that a household fire safety audit be conducted and a fi re escape plan be developed. 1. Are all electrical applia nces and outlets in a safe condition? Check for frayed cord ...

  • ADT PowerSeries SCW9045-433 - page 18

    14 ...

  • ADT PowerSeries SCW9045-433 - page 19

    NOTES: ...

  • ADT PowerSeries SCW9045-433 - page 20

    WA R N I N G Please Read Ca refully Note to Installe rs This warning contains vital information. As the onl y individual in contact with system users, it is your responsibility to bring each item in this warn- ing to the attention of the users of this system. System Fai lures This system has been carefully designed to be as effective as possible. T ...

Fabricant ADT Catégorie Home Security System

Les documents que nous recevons du fabricant de l'appareilADT PowerSeries SCW9045-433 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques ADT
- manuels d’utilisations PowerSeries SCW9045-433
- fiches produit ADT
- dépliants
- ou étiquettes-énergie ADT PowerSeries SCW9045-433
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation ADT PowerSeries SCW9045-433.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation ADT PowerSeries SCW9045-433, manuels d’entretien, brefs manuels ou manuels de l’utilisateur ADT PowerSeries SCW9045-433. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit ADT PowerSeries SCW9045-433.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil ADT PowerSeries SCW9045-433, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser ADT PowerSeries SCW9045-433 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs ADT PowerSeries SCW9045-433.

Le manuel d’utilisation complet ADT, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel ADT PowerSeries SCW9045-433 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières ADT PowerSeries SCW9045-433, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lADT PowerSeries SCW9045-433 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil ADT PowerSeries SCW9045-433 - qui devraient nous aider dans les premières étapes lors de l'utilisation ADT PowerSeries SCW9045-433
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de ADT PowerSeries SCW9045-433
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service ADT PowerSeries SCW9045-433 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de ADT PowerSeries SCW9045-433?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec ADT PowerSeries SCW9045-433, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec ADT PowerSeries SCW9045-433 il est probable qu’il a envie de partager la façon de le résoudre.