Manuel d’utilisation Vanguard Heating 107156-01E.pdf

38 pages 4.53 mb
Télécharger

Aller à la page of 38

Summary
  • Vanguard Heating 107156-01E.pdf - page 1

    UNVENTED (VENT -FREE) PROP ANE/LP GAS FIREPLACE OWNER’S OPERA TION AND INST ALLA TION MANUAL Save this manual for future reference. Save this manual for future reference. Shown with optional cabinet mantel, hearth base, and trim accessories. WARNING: If the information in this manual is not fol- lowed exactly, a fire or explosion may result causi ...

  • Vanguard Heating 107156-01E.pdf - page 2

    107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 2 Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies. Do not place clothing or other flammable material on or near the appliance. Never place any objects on the heater. Fireplace front and ...

  • Vanguard Heating 107156-01E.pdf - page 3

    107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 3 3 PRODUCT IDENTIFICA TION Figure 1 - Log Base Assembly, Split Oak Set Rear Log Rear Burner Crossover Log Middle Log Front Log Front Burner SAFETY INFORMA TION Continued 1. This appliance is only for use with the type of gas indicated on the rating ...

  • Vanguard Heating 107156-01E.pdf - page 4

    107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 4 AIR FOR COMBUSTION AND VENTILA TION Today’s homes are built more energy efficient than ever. New mate- rials, increased insulation, and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows a ...

  • Vanguard Heating 107156-01E.pdf - page 5

    107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 5 5 DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this work sheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install heater plus any ...

  • Vanguard Heating 107156-01E.pdf - page 6

    107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 6 VENTILATION AIR Ventilation Air From Inside Building This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must provide two permanent openings: one within 12" of the ceiling and o ...

  • Vanguard Heating 107156-01E.pdf - page 7

    107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 7 7 INST ALLA TION Continued Note: Your fireplace is designed to be used in zero clearance installations. Wall or framing material can be placed directly against any exterior surface on the rear, sides, or top of your fireplace, except where standof ...

  • Vanguard Heating 107156-01E.pdf - page 8

    107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 8 INST ALLA TION Continued Figure 7 - Attaching Brass Trim to Fireplace Figure 6 - Assembling Brass Trim IMPORTANT: If you are recessing the firebox in a wall, do not attach brass trim at this time. See page 1 0 for built-in fireplace installation. ...

  • Vanguard Heating 107156-01E.pdf - page 9

    107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 9 9 Figure 9 - Placing Hearth Base Accessory Against Wall Electrical Outlet Hearth Base Rigid Pipe and Gas Shutoff Valve Gas Line Access Hole INST ALLA TION Continued Figure 10 - Installing Cabinet Mantel Cabinet Mantel 1. Assemble cabinet mantel, h ...

  • Vanguard Heating 107156-01E.pdf - page 10

    107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 10 Mantel Clearances for Built-In Installation If placing mantel above built-in fireplace, you must meet minimum clearance between mantel shelf and top of fireplace opening. If your installation does not meet the below minimum clearances, you must: ...

  • Vanguard Heating 107156-01E.pdf - page 11

    107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 11 11 Pipe Tee Nipple Cap Joint INST ALLA TION Continued CAUTION: Use only new, black iron or steel pipe. Internally-tinned copper tubing may be used in cer- tain areas. Check your local codes. Use pipe of 1/2" diameter or greater to allow prop ...

  • Vanguard Heating 107156-01E.pdf - page 12

    107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 12 Pressure Testing Gas Supply Piping System Test Pressures In Excess Of 1/2 PSIG (3.5 kPa) 1. Disconnect fireplace with its appliance main gas valve (control valve) and equipment shutoff valve from gas supply pipping. Pres- sures in excess of 1/2 p ...

  • Vanguard Heating 107156-01E.pdf - page 13

    107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 13 13 Equipment Shutoff Valve Propane/LP Supply Tank INST ALLA TION Continued Figure 21 - Equipment Shutoff Valve ON POSITION OFF POSITION Open Closed Equipment Shutoff Valve Figure 22 - Checking Gas Joints Gas Control Valve Test Pressures Equal To ...

  • Vanguard Heating 107156-01E.pdf - page 14

    107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 14 A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, f ollo w these instructions e xactly . B. BEFORE LIGHTING smell all ar ound the appliance ar ea for gas. Be sur e to smell next to the floor because some gas is ...

  • Vanguard Heating 107156-01E.pdf - page 15

    107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 15 15 Figure 29 - Pilot CAUTION: Do not try to adjust heating levels by using the equipment shutoff valve. LIGHTING INSTRUCTIONS WARNING: You must operate this fireplace with the fireplace screen in place. Make sure fireplace screen is installed bef ...

  • Vanguard Heating 107156-01E.pdf - page 16

    107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 16 Figure 31 - Pilot Ignitor Electrode Pilot Burner IGNITOR Figure 30 - Control Knob and Ignitor Button Location Ignitor Button Control Knob OPERA TING FIREPLACE Continued A. This appliance has a pilot which must be lighted by hand. When lighting th ...

  • Vanguard Heating 107156-01E.pdf - page 17

    107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 17 17 OPERA TING FIREPLACE Continued Locate the blower switch by opening lower louver on fireplace. Blower switch is located at lower left inside louver door. This thermostat-controlled blower has a variable speed control with an ON/OFF switch. The ...

  • Vanguard Heating 107156-01E.pdf - page 18

    107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 18 If front burner flame pattern is incorrect, as shown in Figure 35 • turn fireplace of f (see T o T urn Off Gas to Appliance , page 15 [ther- mostat-controlled models] or page 17 [manually-controlled models]) • see T roubleshooting , pages 20 ...

  • Vanguard Heating 107156-01E.pdf - page 19

    107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 19 19 CLEANING AND MAINTENANCE WARNING: Turn off fireplace and let cool before cleaning. CAUTION: You must keep control areas, burners, and circulating air passageways of fireplace clean. Inspect these areas of fireplace before each use. Have firepl ...

  • Vanguard Heating 107156-01E.pdf - page 20

    107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 20 POSSIBLE CAUSE 1. Ignitor electrode not connected to igni- tor cable 2. Piezo ignitor nut is loose 3. Ignitor cable pinched or wet 4. Broken ignitor cable 5. Bad piezo ignitor 6. Ignitor electrode broken 7. Ignitor electrode positioned wrong 1 . ...

  • Vanguard Heating 107156-01E.pdf - page 21

    107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 21 21 TROUBLESHOOTING Continued OBSERVED PROBLEM One or both burners do not light after ODS/ pilot is lit Delayed ignition of one or both burners Burner backfiring during combustion Yellow flame in front burner during burner combustion Slight smoke ...

  • Vanguard Heating 107156-01E.pdf - page 22

    107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 22 TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neigh ...

  • Vanguard Heating 107156-01E.pdf - page 23

    107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 23 23 Btu (Low/High) 20,000/28,000 Type Gas Propane/LP Gas Only Ignition Piezo Manifold Pressure 7.9" W.C. Inlet Gas Pressure (in. of water) Maximum 14" Minimum 11" Shipping Weight 100 lbs. T-stat Model 97 lbs. Manual Model SPECIFICA ...

  • Vanguard Heating 107156-01E.pdf - page 24

    107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 24 ILLUSTRA TED P ARTS BREAKDOWN LOG BASE ASSEMBLY VARIABLE MANUALLY- CONTROLLED MODELS VSGF28PVA 26 7 8 7 7 18 6 12 11 7 5 9 17 22 15 10 25 13 5 5 5 5 20 14 18 31 28 23 29 19 27 30 24 16 21 32 1 2 3 4 ILLUSTRATED PARTS BREAKDOWN VSGF28PVA ...

  • Vanguard Heating 107156-01E.pdf - page 25

    107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 25 25 P AR TS LIST LOG BASE ASSEMBLY VARIABLE MANUALLY-CONTROLLED MODELS VSGF28PVA This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 23 of this manual. KE ...

  • Vanguard Heating 107156-01E.pdf - page 26

    107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 26 ILLUSTRA TED P ARTS BREAKDOWN FIREPLACE VSGF28PVA 1 2 3 16 4 6 12 18 10 10 7 13 16 16 16 7 17 14 5 16 16 15 8 9 16 11 11 11 ILLUSTRATED PARTS BREAKDOWN VSGF28PVA ...

  • Vanguard Heating 107156-01E.pdf - page 27

    107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 27 27 P AR TS LIST FIREPLACE VSGF28PVA This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 23 of this manual. KEY NO. PART NUMBER DESCRIPTION QTY. 1 101357- ...

  • Vanguard Heating 107156-01E.pdf - page 28

    107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 28 ILLUSTRA TED P ARTS BREAKDOWN LOG BASE ASSEMBLY THERMOSTAT-CONTROLLED MODELS VSGF28PTC 17 5 7 8 7 7 18 6 12 26 11 1 2 4 3 9 15 10 25 13 28 5 5 5 5 21 24 22 18 23 12 6-2 19 14 27 20 28 16 ILLUSTRATED PARTS BREAKDOWN VSGF28PTC ...

  • Vanguard Heating 107156-01E.pdf - page 29

    107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 29 29 P AR TS LIST LOG BASE ASSEMBLY THERMOSTAT-CONTROLLED MODELS VSGF28PTC This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 23 of this manual. KEY NO. P ...

  • Vanguard Heating 107156-01E.pdf - page 30

    107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 30 ILLUSTRA TED P ARTS BREAKDOWN FIREPLACE VSGF28PTC 1 2 3 4 16 16 6 12 18 10 10 7 13 16 26 24 16 23 25 20 24 24 21 16 16 7 17 14 5 16 16 15 8 9 19 22 11 11 11 ILLUSTRATED PARTS BREAKDOWN VSGF28PTC ...

  • Vanguard Heating 107156-01E.pdf - page 31

    107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 31 31 P AR TS LIST FIREPLACE VSGF28PTC This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 23 of this manual. KEY NO. PART NUMBER DESCRIPTION QTY. 1 101357- ...

  • Vanguard Heating 107156-01E.pdf - page 32

    107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 32 SLIM HEARTH BASE (Not Shown) G3005J Series - Jade Marble Laminate G3005S Series - Sandstone Marble Laminate G3005B Series - Black Onyx Marble Laminate The slim hearth base allows you to further customize your fireplace. Dimensions (WxHxD): 41 7 / ...

  • Vanguard Heating 107156-01E.pdf - page 33

    107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 33 33 EQUIPMENT SHUTOFF VALVE - GA5010 For all models. Equipment shutoff valve with 1/8" NPT tap. Fits 1/2" NPT pipe. BLOWER ACCESSORIES FOR MANUALLY- CONTROLLED UNITS GA3750A & GA3650TB SERIES Manual variable speed control and automat ...

  • Vanguard Heating 107156-01E.pdf - page 34

    107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 34 NOTES _______________________________________________________________________________________________ _______________________________________________________________________________________________ ________________________________________________ ...

  • Vanguard Heating 107156-01E.pdf - page 35

    107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 35 35 1. Where will the product be used? ❍ Living/Family Room ❍ Office/W arehouse ❍ Utility Shed/Outbuilding ❍ Garage ❍ Bedroom ❍ Bathroom ❍ Other 2. If you bought this product yourself, did you plan to purchase this type of product be ...

  • Vanguard Heating 107156-01E.pdf - page 36

    107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 36 2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 Postage Required TM T APE T APE ...

  • Vanguard Heating 107156-01E.pdf - page 37

    107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 37 37 NOTES _______________________________________________________________________________________________ _______________________________________________________________________________________________ _____________________________________________ ...

  • Vanguard Heating 107156-01E.pdf - page 38

    107156-01E For more information, visit www.desatech.com For more information, visit www.desatech.com 38 Model Serial No. Date Purchased LIMITED WARRANTY VENT-FREE PROPANE/LP GAS FIREPLACE DESA International warrants this product to be free from defects in materials and components for four (4) years and five (5) years on stainless steel burners from ...

Fabricant Vanguard Heating Catégorie Indoor Fireplace

Les documents que nous recevons du fabricant de l'appareilVanguard Heating 107156-01E.pdf peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Vanguard Heating
- manuels d’utilisations 107156-01E.pdf
- fiches produit Vanguard Heating
- dépliants
- ou étiquettes-énergie Vanguard Heating 107156-01E.pdf
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Vanguard Heating 107156-01E.pdf.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Vanguard Heating 107156-01E.pdf, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Vanguard Heating 107156-01E.pdf. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Vanguard Heating 107156-01E.pdf.

Manuel d’utilisation complet de l’appareil Vanguard Heating 107156-01E.pdf, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Vanguard Heating 107156-01E.pdf par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Vanguard Heating 107156-01E.pdf.

Le manuel d’utilisation complet Vanguard Heating, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Vanguard Heating 107156-01E.pdf - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Vanguard Heating 107156-01E.pdf, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lVanguard Heating 107156-01E.pdf qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Vanguard Heating 107156-01E.pdf - qui devraient nous aider dans les premières étapes lors de l'utilisation Vanguard Heating 107156-01E.pdf
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Vanguard Heating 107156-01E.pdf
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Vanguard Heating 107156-01E.pdf dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Vanguard Heating 107156-01E.pdf?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Vanguard Heating 107156-01E.pdf, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Vanguard Heating 107156-01E.pdf il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)