Manuel d’utilisation Interquartz ID202

27 pages Non applicable
Télécharger

Aller à la page of 27

Summary
  • Interquartz ID202 - page 1

    Doorphone – ID 201 Doorphone – ID 202 Doorphone – ID 204 User manual INTERQUARTZ ...

  • Interquartz ID202 - page 2

    Conten ts 1 BASIC DESCRIPTION ......... .......... ......... ......... .......... ......... .......... ......... ......... ... 3 1.1 F EATURES ......... .......... ......... ......... .......... ......... ......... .......... ......... .......... ........ 3 1.2 S LI M D OOR P HONE MODEL S ......... .......... ......... ......... .......... ........ ...

  • Interquartz ID202 - page 3

    8 DRILLING MAST ER BOARD ..... ......... .......... ......... ......... .......... ......... .......... . 27 1 Basic descript ion 1.1 Features  Very slim module for surfac e mounting o nly. S upplied in 1, 2 or 4 button variants.  Voice comm unication powered fr om analogue telephon e line only.  Pulse and tone (DT MF) dial  Two 16 digi ...

  • Interquartz ID202 - page 4

    1.2 DoorPhone models Three versions are available : ID 201 -1 butt on ID 202 - 2 bu ttons ID 204 - 4 buttons 2 Installation This com pact unit is fixed by 2 scre ws to the wall. 2.1 Opening, wiring, wall mounting and settings 2.1.1 Name card pane l 1. Every unit is supplied wi th a special key w hich is used to release t he n am e car ds on the fro ...

  • Interquartz ID202 - page 5

    2.1.2 Uncover cont rol eleme nts 4. Push the aluminium s peaker grille down (see figure – 4). 2.1.3 Wiring and wall mounti ng 5. Use the wall mounting template at the end of the manual to m ark the position for the scr ew holes an d cable connection o n the mounting surf ace. Drill th e holes. 6. Feed t he ca ble (an alogue line, power sup ply, l ...

  • Interquartz ID202 - page 6

    (central) and " NC " means contact normally c losed. T he relay contact is isolated fr om the other c ircuits on th e boar d. For t he v ariants of lock connection see th e picture belo w. W iring of standard and magnetic (in verse) lock 7. A special U SB ca ble en ables the doorphone to b e co nnected to a PC for progra mm ing of individ ...

  • Interquartz ID202 - page 7

    The PCB heating has two m ajor benefits. Firstl y, it warm s the board during winter tim e (temperatures under -20 C, most circuits have warrant y operation down to - 20 C) and secondly it helps to protect the PCB ag ainst humidity when ins talled outs ide. 2.1.5 Voice level 10. Voice communic ation – the trimmer position is factor y and should b ...

  • Interquartz ID202 - page 8

    2.2 Location of ID Doorphone components All mounting, control and setting elem ents are located under the speak er front aluminium grille. . PC connec tor SlimDoorPhone fixing screw hole Service switch Loudspeaker MIC-setting of microphone volume TRH – setting of microphone activation level SPK- setting of speaker volum e Heating activation 12V = ...

  • Interquartz ID202 - page 9

    2.3 Changing name cards Name car d panel (2.1.1on page 4) h as spaces to insert printed nam e cards. Insert nam e cards from top (s ee picture). Cards c an easily be printed with pictures as well as text using the included software. The card outline is marked for easy cutting . 2.4 Final closing of ID Doorphone 2.4.1 Covering con trol elemen ts 1. ...

  • Interquartz ID202 - page 10

    3 Doorphon e Services 3.1 Signalling Overview The unit s ignals acoustic c onditions tha t m ay occur du ring operat ion. You can listen to the sig nalling sam ples in the ID Manag er program. Condition Tones Tone frequenc y Pick up line – ▄ – ■ – ▀ – 425-850-1275 Hang up line – ▀ – ■ – ▄ 1275-850-425 Confirm command –? ...

  • Interquartz ID202 - page 11

    from the second group ( p arameter 2 ). The next pr ess of the same button again selects the num ber from the firs t group, etc..…… If the button is pressed af ter the line has been opened (but before the call is ans wered), the unit will hang up for the per iod given by paramet er 54, lift up the line and dia l the other group number. The rela ...

  • Interquartz ID202 - page 12

    4 Parameter progra mming 4.1 Programming from a telephone by DT MF 4.1.1 Entering progra mming mode The SlimDoorPhone ma y be set to programm ing mode in two w ays: 1. by passw ord – d ial the unit‘s num ber (eit her extension number, if connected to a PBX or telephone number, if co nnected to a PSTN line) . T he unit wi ll ans wer ( you will h ...

  • Interquartz ID202 - page 13

    Note 1 . i f you wish to maintain the connection in programming mode (i.e. ex tend the 34 seconds pe riod) then it is necessary to o ccasionally press a key (e.g. * , # or 7). The unit will respond with an error tone but the connection will be kept alive. Note 2. The # si gn is not used in the values for parameters 32 ,33 an d 34, and can be used t ...

  • Interquartz ID202 - page 14

    5 Parameter descr iption 5.1 Direct Dialling – Memories Parameter Value Description Default Exam.1 Exam.2 1 t nn… No. nn under button t - - - t – Button num ber (memor y) [1-4] nn – te lephone number up to 16 di gits to be stor ed. Refer to the table for ot her choices. The num ber stored in param eter 1 is the n umber f or the first group ...

  • Interquartz ID202 - page 15

    Parameter Value Description Default Exam .1 Exam.2 32 hhhhhh External access code in DAY + NIGHT mode - 1212 1324 33 hhhhhh External access code in DAY mode - 2211 2211 34 hhhhhh External access code in NIGHT mode - 1122 1122 hhhhhh – password for rela y closing fr om buttons [2 to 6 dig its] The 3 passwords are controlled b y D ay/Night; the com ...

  • Interquartz ID202 - page 16

    Parameter Value Description Default Exam .1 Exam.2 38 cc Internal access code 2 impulses 66 66 66 cc – comm and from phone to rel ay closing [2 digits] – 2 impulses Parameter Value Description Default Exam.1 Exam.2 39 hhhhhh External access code in DAY + NIGHT mode for 2 impulses 66 66 66 hhhhhh – password for rela y closing from buttons [2 t ...

  • Interquartz ID202 - page 17

    Parameter Value Description Default Exam.1 Exam.2 44 xxxx Password 0000 0000 0000 xxxx – s ervice password for entry to programm ing Parameter Value Description Default Exam.1 Exam.2 45 dd DAY MODE switching 11 11 11 46 nn NIGHT MODE switching 10 10 10 dd – command for D A Y MODE switching [ 2 digits] nn – command for NIGHT MODE switching [2 ...

  • Interquartz ID202 - page 18

    Parameter Value Description Def ault Exam.1 Exam.2 53 w time between button presses 2 2 2 w – m ax. time [sec ] between button presses [range 1-9] - re lay clo sing – if time bet ween t wo next press es is bigger than w time, the code is n ot evaluated corr ectly. - dialling – if the bu tton pressed is the firs t password number for switch cl ...

  • Interquartz ID202 - page 19

    Parameter Value Description Def ault Exam.1 Exam.2 57 t DTMF tone duration (ms) 5 (100ms ) 5 (100ms ) 5 (100ms ) 58 m Space duration between DTMF tones (ms) 5 (100ms ) 5 (100ms ) 5 (100ms ) 59 f Recall duration (ms) 1 (100ms ) 1 (100ms ) 1 (100ms ) 50 p Pause duration (ms) 8 (800ms ) 8 (800ms ) 8 (800ms ) t – DT MF tone duration is det ermined b ...

  • Interquartz ID202 - page 20

    Parameter Value Description Def ault Exam.1 Exam.2 5*2 y Frequency of tone detection 4 4 4 y – s etting range frequency of tone detection from telephone line, value is in next table: y frequency rang e y frequency rang e 1 200-350Hz 7 500-650Hz 2 250-400Hz 8 550-700Hz 3 300-450Hz 9 600-750Hz 4 350-500Hz 0 650-800Hz 5 400-550Hz * 700-850Hz 6 450-6 ...

  • Interquartz ID202 - page 21

    Parameter Value Description Def ault Exam.1 Exam.2 81 Deletes all numbers in group 1 (Day mode) 82 Deletes all numbers in group 2 (Night mode) 83 Default setting only for parameters 3x only 3.. 84 Default setting only for parameters 4x only 4.. 85 Default setting only for parameters 5x only 5.. The parameters 81 an d 82 will delete all numbers stor ...

  • Interquartz ID202 - page 22

    Parametr Value Descript ion Default Exam.1 Exam.2 6 z Acoustic signalling 3 and 9 3 and 9 3 and 9 In default the un it produces acoustic signals. It can occas ionally cause a problem of incorrect detection of tones b y PBX. By changing param eter „ z“ you can s witc h off this acoustic s ignalization. T he values are: z=0 – all signalling is ...

  • Interquartz ID202 - page 23

    36 ss Relay closing time 05 02 05 37 pp Time between 2 impulses 05 05 05 38 cc Internal access code 2 impulses 66 66 66 39 hhh hhh External access code in DAY + NIGHT mode for 2 impulses - - - 41 v Dialling type 0 0 0 42 z Prolong call * * * 43 bb End call 55 55 55 44 x xxx Password 0000 0000 0000 45 dd DAY MODE switching 11 11 11 46 nn NIGHT MODE ...

  • Interquartz ID202 - page 24

    6 * t Delay of line connection (Siemens PBX) 1 1 1 6 z Acoustic signalling 3 and 9 3 an d 9 3 and 9 8# # Default setting executes 8# 1 Setting per exam. 1 executes 8# 2 Setting per exam. 2 executes 81 Deletes all numbers in group 1 (Day mode) 82 Deletes all numbers in group 2 (Night mode) 83 Default setting only for parameters 3x only 3.. 84 Defaul ...

  • Interquartz ID202 - page 25

    switches and heat ing Max. consum ption of lighting through and heat ing 300mA 12V Max. voltage of s witch contac t 48V at I < 1A Max. current of switch contact 2A at U < 30 V Operational tem perature - 20 to + 50° C 6.2 Mechanical dimensions Dimensions W xHxD 104m m x 153mm x 16mm W eight 360g Unit material elox aluminium profile Name car d ...

  • Interquartz ID202 - page 26

    Relay closing time [sec] 36 2 Time between 2 impulses [sec] 37 2 Internal access code 2 impulses 38 2 External access code 2 impulses Day+Night 39 6 Dialling type 1 / 0 41 1 Prolong call *  / # 42 1 End call 43 2 Password 44 4 DAY MODE switching 45 2 NIGHT MODE switching 46 2 Dialling mode 1 / 0 47 1 No. of rings before pick-up 51 1 Maximum call ...

  • Interquartz ID202 - page 27

    8 Drilling master bo ard ...

Fabricant Interquartz Catégorie Intercom system

Les documents que nous recevons du fabricant de l'appareilInterquartz ID202 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Interquartz
- manuels d’utilisations ID202
- fiches produit Interquartz
- dépliants
- ou étiquettes-énergie Interquartz ID202
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Interquartz ID202.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Interquartz ID202, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Interquartz ID202. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Interquartz ID202.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Interquartz ID202, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Interquartz ID202 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Interquartz ID202.

Le manuel d’utilisation complet Interquartz, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Interquartz ID202 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Interquartz ID202, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lInterquartz ID202 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Interquartz ID202 - qui devraient nous aider dans les premières étapes lors de l'utilisation Interquartz ID202
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Interquartz ID202
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Interquartz ID202 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Interquartz ID202?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Interquartz ID202, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Interquartz ID202 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)