Manuel d’utilisation Schneider Electric 3BZ2

22 pages 2.27 mb
Télécharger

Aller à la page of 22

Summary
  • Schneider Electric 3BZ2 - page 1

    ...

  • Schneider Electric 3BZ2 - page 2

    ...

  • Schneider Electric 3BZ2 - page 3

    The world's first EOCR with built-in ZCT (bottom hole & terminal type) will save space, time and wiring through unique development design during installation. with compact size, possible to be applied to various panel size. the protection function added for high groud fault current. most suitable for low frequency circumstance (5Hz~, Invet ...

  • Schneider Electric 3BZ2 - page 4

    Applications Building Office, commercial business, residence, school, hospital Industrial facilities Petrochemical, electronic, glass, steel, semiconductor, chemical, medicine, cement, paint ...

  • Schneider Electric 3BZ2 - page 5

    Public institutions Gas, water supply and drainage, airport, train, port Control power ● 24 VDC ● 85~260 VAC/DC, 50/60 Hz Composition by function ● Earth Fault ● i3BZ, iFBZ (with Modbus RS-485) ● 3BZ2, FBZ2 (without Modbus RS-485) Contact contact ● A-Type ● 95-96(b), 97-98(a) : OL ● 57-58(a) : GR ● C-Type ● 95-96(b), 97-98(a) : ...

  • Schneider Electric 3BZ2 - page 6

    6 EOCR-i3BZ/iFBZ/3BZ2/FBZ2 EOCR-i3BZ / iFBZ : Intelligent Digital Over-Current, Earth Fault Relay with built-in ZCT, EOCR-3BZ2 / FBZ2 : Economic Digital Over-Current, Earth Fault Relay with built-in ZCT Earth fault detection by built-in ZCT Multifunctional motor protection for rated motor currents up to 80A (Definite Overcurrent protection) : Over ...

  • Schneider Electric 3BZ2 - page 7

    7 EOCR-i3BZ/iFBZ/3BZ2/FBZ2 EOCR-i3BZ / iFBZ : Intelligent Digital Over-Current, Earth Fault Relay with built-in ZCT, EOCR-3BZ2 / FBZ2 : Economic Digital Over-Current, Earth Fault Relay with built-in ZCT Item Operating Condition & Setting Range Operation Time Over Current (oc) Load current(In) exceeds threshold(Is) Definite(Def) : 0.2~30s Adjust ...

  • Schneider Electric 3BZ2 - page 8

    8 EOCR-i3BZ/iFBZ/3BZ2/FBZ2 EOCR-i3BZ / iFBZ : Intelligent Digital Over-Current, Earth Fault Relay with built-in ZCT, EOCR-3BZ2 / FBZ2 : Economic Digital Over-Current, Earth Fault Relay with built-in ZCT Over Current Rated Setting Range(A) Definite TCC : 0.5~80A Inverse & th TCC : 0.5~32A *** CAUTION : Do not use any external CT Under Current Ra ...

  • Schneider Electric 3BZ2 - page 9

    9 EOCR-i3BZ/iFBZ/3BZ2/FBZ2 EOCR-i3BZ / iFBZ : Intelligent Digital Over-Current, Earth Fault Relay with built-in ZCT, EOCR-3BZ2 / FBZ2 : Economic Digital Over-Current, Earth Fault Relay with built-in ZCT Time-current characteristic cur ve 2. Definite characteristic 3. Inverse thermal characteristic (0.5~32A) 1. Inverse characteristic (0.5~32A) ...

  • Schneider Electric 3BZ2 - page 10

    10 EOCR-i3BZ/iFBZ/3BZ2/FBZ2 EOCR-i3BZ / iFBZ : Intelligent Digital Over-Current, Earth Fault Relay with built-in ZCT, EOCR-3BZ2 / FBZ2 : Economic Digital Over-Current, Earth Fault Relay with built-in ZCT Over current and time setting tips ● Over current Setting tips in definite TCC mode 1. Over current threshold (OC) : - Set the OC at the rating ...

  • Schneider Electric 3BZ2 - page 11

    11 EOCR-i3BZ/iFBZ/3BZ2/FBZ2 EOCR-i3BZ / iFBZ : Intelligent Digital Over-Current, Earth Fault Relay with built-in ZCT, EOCR-3BZ2 / FBZ2 : Economic Digital Over-Current, Earth Fault Relay with built-in ZCT Front face 3 phase currents (In) and the leakage current are displayed every 2 seconds in sequence. Bar graph  it shows the load factor to OC s ...

  • Schneider Electric 3BZ2 - page 12

    12 EOCR-i3BZ/iFBZ/3BZ2/FBZ2 EOCR-i3BZ / iFBZ : Intelligent Digital Over-Current, Earth Fault Relay with built-in ZCT, EOCR-3BZ2 / FBZ2 : Economic Digital Over-Current, Earth Fault Relay with built-in ZCT L1 current display 2sec 2sec 2sec 2sec L2 current display Rotate L3 current display GF current 3 phase digital ammeter function  Blocking displ ...

  • Schneider Electric 3BZ2 - page 13

    1 Password 2 Selection of Phase 3 TCC Selection 4 Frequency 5 Fail Safe Reversed Phase 6 detection 7 Over Current Threshold 8 Start Delay Time 9 Over Current Duration Under Current 10 Threshold Under Current 11 Duration Earth Fault 12 (Ground Fault) Threshold 13 Earth Fault Duration 14 EF starting Delay 15 Phase Loss 16 Phase Loss Time 17 Unbalance ...

  • Schneider Electric 3BZ2 - page 14

    Threshold of Alert output, set by % of the over current threshold (oc). If the load current is higher than this value, alert output(07-08 contact) is energized according to the setting of “ ALo:XX ” . If the load current is detected, alert output(07-08 contact) is energized. The alert threshold is no meaning for this operation. Refer to the Ale ...

  • Schneider Electric 3BZ2 - page 15

    15 EOCR-i3BZ/iFBZ/3BZ2/FBZ2 EOCR-i3BZ / iFBZ : Intelligent Digital Over-Current, Earth Fault Relay with built-in ZCT, EOCR-3BZ2 / FBZ2 : Economic Digital Over-Current, Earth Fault Relay with built-in ZCT Trip Indication Trip Indication after trip with UP/ DN button pressing Trip Cause Indication Contents of Indication L1 LED on L2 LED on L3 LED on ...

  • Schneider Electric 3BZ2 - page 16

    16 EOCR-i3BZ/iFBZ/3BZ2/FBZ2 EOCR-i3BZ / iFBZ : Intelligent Digital Over-Current, Earth Fault Relay with built-in ZCT, EOCR-3BZ2 / FBZ2 : Economic Digital Over-Current, Earth Fault Relay with built-in ZCT Wiring Examples EOCR-i3BZ/iFBZ OL : b, GR : a EOCR-i3BZ/iFBZ OL : 1a 1b, GR : 1a 3 phase line Diagram 3 phase line Diagram 3 phase line Diagram Si ...

  • Schneider Electric 3BZ2 - page 17

    17 EOCR-i3BZ/iFBZ/3BZ2/FBZ2 EOCR-i3BZ / iFBZ : Intelligent Digital Over-Current, Earth Fault Relay with built-in ZCT, EOCR-3BZ2 / FBZ2 : Economic Digital Over-Current, Earth Fault Relay with built-in ZCT Dimensions EOCR-i3BZ / 3BZ2 (Bottom Hole) EOCR-i3BZ / 3BZ2 (Teminal Type) 70 95 82 ∅ 4.5 6- M 4 21.4 21.4 108.1 45.3 53.3 91.3 3- ∅ 12 108.1 2 ...

  • Schneider Electric 3BZ2 - page 18

    18 EOCR-i3BZ/iFBZ/3BZ2/FBZ2 EOCR-i3BZ / iFBZ : Intelligent Digital Over-Current, Earth Fault Relay with built-in ZCT, EOCR-3BZ2 / FBZ2 : Economic Digital Over-Current, Earth Fault Relay with built-in ZCT Order Code i3BZ Intelligent, panel mounting unit  Basic Unit iFBZ Intelligent, flush mounting unit 3BZ2 Economic, panel mounting unit FBZ2 Econ ...

  • Schneider Electric 3BZ2 - page 19

    19 Communication setting value Please set the Modbus communication parameters by PCON or HMI for the communication.  Slave address  Baud rate  Parity  Communication loss timeout Slave address The EOCR has slave addresses from 1 to 247. The factory default setting is 1. Baud rate The Communication speed provided is like below.  1.2kbp ...

  • Schneider Electric 3BZ2 - page 20

    20 Communication Guide The standard connection conforms to the Modbus specifications, sepecially 2 wire multidrop serial bus diagram, presented at the website of Modbus.org in 2002 (Modbus_over_serial_line_V1.pdf, Nov.2002). Simple wiring diagram is like below. The characteristics is like below in case of a direct connection to the bus. Items Conte ...

  • Schneider Electric 3BZ2 - page 21

    21 Communication Guide Bus connection thr ough a SCA type junction box 1. Master (PLC, PC or communication module) 2. Modbus cable (It is different according to the master side or a master having polarization combined to the other part of Bus) 3. Junction box 4. Modbus cable 5. Line terminators : 120 Ω - 0.25W Please use a cable with 2pair shiede ...

  • Schneider Electric 3BZ2 - page 22

    Built_in ZCT catalog_EN ⓒ 2009 Samwha EOCR Ltd.-All rights reserved. 04/2009 Head Office 6 th floor, Jeil Bldg., 94-46, Youngdeungpo-Dong 7Ka, Youngdeungpo-Ku, Seoul, Korea Tel. 82 2 3473 2340 / Fax 82 2 3473 1159 Iksan Plant 574, Yongie-dong, Iksan-shi, Junbuk, Korea Tel. 82 63 835 5033 / Fax 82 63 835 4175 www.eocr.com ...

Fabricant Schneider Electric Catégorie Outboard Motor

Les documents que nous recevons du fabricant de l'appareilSchneider Electric 3BZ2 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Schneider Electric
- manuels d’utilisations 3BZ2
- fiches produit Schneider Electric
- dépliants
- ou étiquettes-énergie Schneider Electric 3BZ2
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Schneider Electric 3BZ2.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Schneider Electric 3BZ2, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Schneider Electric 3BZ2. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Schneider Electric 3BZ2.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Schneider Electric 3BZ2, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Schneider Electric 3BZ2 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Schneider Electric 3BZ2.

Le manuel d’utilisation complet Schneider Electric, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Schneider Electric 3BZ2 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Schneider Electric 3BZ2, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lSchneider Electric 3BZ2 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Schneider Electric 3BZ2 - qui devraient nous aider dans les premières étapes lors de l'utilisation Schneider Electric 3BZ2
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Schneider Electric 3BZ2
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Schneider Electric 3BZ2 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Schneider Electric 3BZ2?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Schneider Electric 3BZ2, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Schneider Electric 3BZ2 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)