    61181300L1-5C Section 61181300L1-5C, Issue 3 1 Section 61181300L1-5C Issue 3, October 2000 CLEI Code # M3O1CD0C_ _ T otal Access TM QFO-C Installation and Maintenance 1. GENERAL This practice is an installation and maintenance guide for the ADTRAN Total Access QFO-C, P/N 1181300L1, illustrated in Figure 1 . See Table 5 for a description of QFO-C fr ...

  • ADTRAN QFO-C - page 2

    2 Section 61181300L1-5C, Issue 3 61181300L1-5C • Installs in both the Total Access 3000 (23-inch) and the Total Access (19-inch) chassis. • End-to-end transmission for one to four DS1 circuits • Operating wavelength 1310 nm • Single mode fiber operation • Power budget of 25dB (typical) • Launch power of -5dBm (typical) • Receiver sens ...

  • ADTRAN QFO-C - page 3

    61181300L1-5C Section 61181300L1-5C, Issue 3 3 Table 3. Pin-out For Pair 5 and 7 on TA 3000 Table 4. Pin-out For Pair 6 and 8 on TA 3000 r o l o C p u o r G r e d n i Br o l o C e r i Wn i P P M A n i P - 4 6 s s e c c A l a t o T t o l S 0 0 0 3 g n i R / p i T ) n I ( E N O N U L B / T H W T H W / U L B 3 3 1 1 T R G R O / T H W T H W / G R O 4 3 ...

  • ADTRAN QFO-C - page 4

    4 Section 61181300L1-5C, Issue 3 61181300L1-5C If the system is configured with only QFO-Cs, all four DSX-1 connections are made. The connections are made via four Amphenol connectors to Pair 5 through Pair 8 on the backplane. Table 5. Pin-out For Pair 5 and 7 on TA 3010 r o l o C p u o r G r e d n i Br o l o C e r i Wn i P P M A n i P - 0 5 s s e ...

  • ADTRAN QFO-C - page 5

    61181300L1-5C Section 61181300L1-5C, Issue 3 5 If no protection switching is provided, the Main unit plugs into any odd-numbered slot. The next higher even-numbered slot may contain a blank card or can be left empty. See Figure 2 . Installing the QFO-C 1. Set the right switch segment S2-2 to Working “on” or Protect “off” depending on where ...

  • ADTRAN QFO-C - page 6

    6 Section 61181300L1-5C, Issue 3 61181300L1-5C Release the card retention lever and carefully seat the card into the backplane connector by firmly pressing on the QFO-C front panel. Verify the fiber cables move freely between the cable guides and the shelf. When installed and powered, the PWR LED (green) on the front panel lights steady. Options Th ...

  • ADTRAN QFO-C - page 7

    61181300L1-5C Section 61181300L1-5C, Issue 3 7 Table 7 . QFO-C Card Provisioning The card is provisioned through the craft port on the SCU or by the FCD. Detailed procedures for provisioning the QFO-C start on page 11 with the section labeled Fiber (QFO-C) Main Menu. The screenshots are accompanied by steps to assist in provisioning the unit. Table ...

  • ADTRAN QFO-C - page 8

    8 Section 61181300L1-5C, Issue 3 61181300L1-5C Option Description Service State Enables normal connection to the DSX or multiplexer interface Loops will train up but will not connect to the DSX or multiplexer interface Supports active connections to the DSX or multiplexer interface; however, alarms cannot be generated DSX Equalization Conditions th ...

  • ADTRAN QFO-C - page 9

    61181300L1-5C Section 61181300L1-5C, Issue 3 9 • ESCAPE – press the switch in the MODE direction and release it between 1.5 seconds and 3 seconds to ascend the menu tree. • ROOT - press the switch in the MODE direction and release it after 3 seconds to return to the first element of the Level 1 card menu. To enter the SCU, MUX, or LINE CARD ( ...

  • ADTRAN QFO-C - page 10

    10 Section 61181300L1-5C, Issue 3 61181300L1-5C Figure 4. QFO-C FCD Menu Tree STAT VIEW PROV SRVC STAT DEX EQ LB TOUT AIS TO DSX LOS AIS TO DSX FLOS DSBL ENBL SAVE NO SAVE YES NO DONE ES SES UAS 15 MIN ERR THLD P1 P2 P3 P4 P1 P0 P2 P3 P4 IN SRVC Level 3 ESCAPE (1.5-3 sec.) SELECT (<1.5 sec.) Level 2B Level 2A Level 1 UNAS MAINT ALRM PROV TEST 24 ...

  • ADTRAN QFO-C - page 11

    61181300L1-5C Section 61181300L1-5C, Issue 3 11 Table 9. QFO-C Menu Hierarchy QFO-C Main Menu Configuration Provisioning Service State Port 0/1/2/3/4 All Provisioning DSX Equalization Loop Back Timeout AIS to DSX (Loss of T1) AIS to DSX (FLOS) Restore Factory Defaults Status Port 1/2/3/4 All Ports Alarms View Alarms Alarm Provisioning ES Threshold ...

  • ADTRAN QFO-C - page 12

    12 Section 61181300L1-5C, Issue 3 61181300L1-5C Shelf: Slot: 10 Total Access System 07/15/99 10:37 Unacknowledged Alarms: MINOR QFO-C Main Menu 1. Configuration 2. Provisioning 3. Status 4. Alarms 5. Test 6. Performance Monitoring 7. Protection Switching 8. Circuit Id Selection: ‘?’ - System Help Screen Figure 6. QFO-C Configuration Screen Shel ...

  • ADTRAN QFO-C - page 13

    61181300L1-5C Section 61181300L1-5C, Issue 3 13 Figure 8. Service State Screen Shelf: Slot: 10 Total Access System 07/15/99 10:42 Unacknowledged Alarms: None Service State 1. Port 0 Out of Service - Unassigned 2. Port 1 Out of Service - Unassigned 3. Port 2 Out of Service - Unassigned 4. Port 3 Out of Service - Unassigned 5. Port 4 Out of Service - ...

  • ADTRAN QFO-C - page 14

    14 Section 61181300L1-5C, Issue 3 61181300L1-5C Figure 10. Provisioning of All Ports Screen Shelf: Slot: 10 Total Access System 07/15/99 10:45 Unacknowledged Alarms: MINOR Provisioning for All Ports 1. DSX Equalization 0 to 133' ABAM 2. Loopback Timeout 120 Min. 3. AIS to DSX (Loss of T1) Disabled 4. AIS to DSX (FLOS) Disabled 5. Restore Facto ...

  • ADTRAN QFO-C - page 15

    61181300L1-5C Section 61181300L1-5C, Issue 3 15 NOTE Port 0 (all ports) “Out of Service” disables the entire module. Port 0 must be “In Service” for any Port 1 to 4 to be active. Changing the DSX Equalization 1. From the Provisioning of All Ports screen, type “1” and press Enter to select DSX Equalization. The DSX Equalization Screen ( ...

  • ADTRAN QFO-C - page 16

    16 Section 61181300L1-5C, Issue 3 61181300L1-5C Figure 13. AIS to DSX (Loss of T1) Shelf: Slot: 10 Total Access System 07/15/99 10:43 Unacknowledged Alarms: None AIS to DSX (Loss of T1): Disabled 1. Disabled 2. Enabled Selection: ‘?’ - System Help Screen Figure 14. AIS to DSX (FLOS) Screen Shelf: Slot: 10 Total Access System 07/15/99 10:43 Unac ...

  • ADTRAN QFO-C - page 17

    61181300L1-5C Section 61181300L1-5C, Issue 3 17 Figure 15. Restore Factory Defaults Screen Shelf: Slot: 10 Total Access System 07/15/99 10:43 Unacknowledged Alarms: None Restore Factory Defaults? 1. No 2. Yes Selection: ‘?’ - System Help Screen Figure 16. Status Screen Shelf: 1 Slot: 5 Total Access System 09/11/00 09:28 Unacknowledged Alarms: M ...

  • ADTRAN QFO-C - page 18

    18 Section 61181300L1-5C, Issue 3 61181300L1-5C Shelf: Slot: 10 Total Access System 07/15/99 10:43 Unacknowledged Alarms: None Status of All Ports Near End Far End Fiber Loss No No Laser Bias Alarm No No Adjacent Card Present N/A On Line No No Switched Manually No No RT Auto Mode No No Port 1 Disabled Disabled Port 2 Disabled Disabled Port 3 Disabl ...

  • ADTRAN QFO-C - page 19

    61181300L1-5C Section 61181300L1-5C, Issue 3 19 Shelf: Slot: Total Access System 02/18/98 02:24:18 Unacknowledged Alarm: None Alarms Level ––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––? ...

  • ADTRAN QFO-C - page 20

    20 Section 61181300L1-5C, Issue 3 61181300L1-5C Shelf: Slot: Total Access System 02:24:18 02/18/98 Unacknowledged Alarm: None ES Threshold (15 Min.): 30 1. 30 2. 150 Selection: ? - System Help Screen Figure 22. ES Threshold (15-Minute) Screen Changing Alarm Settings and Thresholds 1. From the QFO-C Main Menu screen, type “4” and press Enter to ...

  • ADTRAN QFO-C - page 21

    61181300L1-5C Section 61181300L1-5C, Issue 3 21 Figure 24. UAS Threshold (15-Minute) Screen Shelf: Slot: Total Access System 02/18/98 02:24:18 Unacknowledged Alarms: None UAS Threshold (15 Min.): 15 1. 15 2. 75 Selection: ‘?’ - System Help Screen Figure 23. SES Threshold (15-Minute) Screen SHELF: SLOT: TOTAL ACCESS SYSTEM 02:24:18 02/18/98 UNAC ...

  • ADTRAN QFO-C - page 22

    22 Section 61181300L1-5C, Issue 3 61181300L1-5C Figure 25. ES Threshold (24-Hour) Shelf: Slot: Total Access System 02:24:18 02/18/98 Unacknowledged Alarm: None ES Threshold (24 Hour): 14400 1. 2880 2. 14400 Selection: ? - System Help Screen Figure 26. SES Threshold (24-Hour) Shelf: 3 Slot: 11 Total Access System 12/15/99 09:38 Unacknowledged Alarms ...

  • ADTRAN QFO-C - page 23

    61181300L1-5C Section 61181300L1-5C, Issue 3 23 Figure 28. Test Screen Shelf: Slot: Total Access System 02/18/98 02:24:18 Unacknowledged Alarms: None Test 1. Port 1 Loopback 2. Port 2 Loopback 3. Port 3 Loopback 4. Port 4 Loopback Selection: ‘?’ - System Help Screen Figure 27. UAS Alarm Threshold (24-Hour) Shelf: 3 Slot: 11 Total Access System ...

  • ADTRAN QFO-C - page 24

    24 Section 61181300L1-5C, Issue 3 61181300L1-5C Figure 29. Port Test Screen Shelf: Slot: Total Access System 02:24:18 02/18/98 Unacknowledged Alarms: None Loopback RT: Disabled 1. Disabled 2. Network 3. Dual Selection: ‘?’ - System Help Screen Figure 30. Loopback RT Screen Shelf: Slot: Total Access System 02/18/98 02:24:18 Unacknowledged Alarms ...

  • ADTRAN QFO-C - page 25

    61181300L1-5C Section 61181300L1-5C, Issue 3 25 Figure 32. Performance Monitoring Screen Shelf: Slot: Total Access System 02:24:18 02/18/98 Unacknowledged Alarms: None Peformance Monitoring 1. Port 1 (Near End) 2. Port 2 (Near End) 3. Port 3 (Near End) 4. Port 4 (Near End) 5. Port 1 (Far End) 6. Port 2 (Far End) 7. Port 3 (Far End) 8. Port 4 (Far E ...

  • ADTRAN QFO-C - page 26

    26 Section 61181300L1-5C, Issue 3 61181300L1-5C Shelf: Slot: Total Access System 02/18/98 02:24:18 Unacknowledged Alarms: None APS Switching 1. ACT Activate Selection: ‘?’ - System Help Screen Figure 34. Protection Switch Screen Viewing Performance Monitoring Screens Type the number corresponding to the port and type of Performance Monitoring d ...

  • ADTRAN QFO-C - page 27

    61181300L1-5C Section 61181300L1-5C, Issue 3 27 Shelf: Slot: Total Access System 02/18/98 02:24:18 Unacknowledged Alarms: None Circuit ID 1. Port 1 2. Port 2 3. Port 3 4. Port 4 Selection: ‘?’ - System Help Screen Figure 36. Circuit ID Screen 2. Type “2” and press Enter to switch the Working QFO-C to protect ( Figure 35 ). Setting the Port ...

  • ADTRAN QFO-C - page 28

    28 Section 61181300L1-5C, Issue 3 61181300L1-5C 2. Type the number of the corresponding port whose Circuit ID is to be set or changed and press Enter. The Port Current Circuit ID Screen (Figure 37) will display. 3. Type the new Circuit ID and press Enter. 4. MAINTENANCE The QFO-C requires no routine maintenance to operate properly. ADTRAN cautions ...

  • ADTRAN QFO-C - page 29

    61181300L1-5C Section 61181300L1-5C, Issue 3 29 Table 10. QFO-C Specifications DS1 Input Level .............................................................. 0 to -9 dBm Output Level ........................................................... 0 dB with DSX buildout from 0 to 655 ft. in 133 ft. incr ements Data Frequency Acceptance 1.544 Mb/sec. ± ...

  • ADTRAN QFO-C - page 30

    30 Section 61181300L1-5C, Issue 3 61181300L1-5C ...

Fabricant ADTRAN Catégorie Network Card

Les documents que nous recevons du fabricant de l'appareilADTRAN QFO-C peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques ADTRAN
- manuels d’utilisations QFO-C
- fiches produit ADTRAN
- dépliants
- ou étiquettes-énergie ADTRAN QFO-C
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation ADTRAN QFO-C.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation ADTRAN QFO-C, manuels d’entretien, brefs manuels ou manuels de l’utilisateur ADTRAN QFO-C. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit ADTRAN QFO-C.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil ADTRAN QFO-C, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser ADTRAN QFO-C par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs ADTRAN QFO-C.

Le manuel d’utilisation complet ADTRAN, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel ADTRAN QFO-C - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières ADTRAN QFO-C, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lADTRAN QFO-C qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil ADTRAN QFO-C - qui devraient nous aider dans les premières étapes lors de l'utilisation ADTRAN QFO-C
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de ADTRAN QFO-C
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service ADTRAN QFO-C dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de ADTRAN QFO-C?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec ADTRAN QFO-C, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec ADTRAN QFO-C il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)