Manuel d’utilisation Pelco FR82041

28 pages 0.83 mb
Télécharger

Aller à la page of 28

Summary
  • Pelco FR82041 - page 1

    ® INST ALLA TION F T82041/FR82041 Unmanaged Ethernet Switch Four 10BASE-T/100BASE-TX Ports and One 100BASE-FX Fiber Port C2623M (2/07) ...

  • Pelco FR82041 - page 2

    ...

  • Pelco FR82041 - page 3

    C2623M (2/0 7) 3 Contents Important Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Regulatory Not ices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Product Overview . . . . . . . . . . . . . . . . . ...

  • Pelco FR82041 - page 4

    4 C2623M (2/07) Important Safety Instructions 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water . 6. Clean only with dry cloth. 7. Do not block any ventilation openings. Inst all in accordance with the manufacturer’ s instructions. 8. Do not install ne ...

  • Pelco FR82041 - page 5

    C2623M (2/0 7) 5 The product and/or manual may bear the following marks: This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit. This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit. CAUTION: RISK OF ELECTRIC SHOCK. DO N ...

  • Pelco FR82041 - page 6

    6 C2623M (2/07) Regulatory Notices This device complies with Part 15 of the FCC Rule s. Operation is subject to the following two conditions: (1) this device may not cause harmful in terference, and (2) this device must accept any interference received, including interfer ence that may cause undesired operation. RADIO AND TELEVIS ION INTERFERENCE T ...

  • Pelco FR82041 - page 7

    C2623M (2/0 7) 7 Product Overview DESCRIPTION The F T82041/FR82041 unmanag ed Ethernet switch provid es four 10BASE-T/100BASE-TX ports and one 100BASE-FX fiber port for the trans port of bidirectional Ethernet data. Designed for point-to-point applications, the F T82041 and FR82041 switches are used in combination with one another to provide wavele ...

  • Pelco FR82041 - page 8

    8 C2623M (2/07) • Designed to meet NEMA TS 2 and Caltrans traff ic signal control equipment standards for ambient operating temperature, mechanical shock and vibrati on, humidity with condensation, high-line/low-line voltage conditions, and transient voltage protection NOTE: Conformal coating is required for operati on in environments with relati ...

  • Pelco FR82041 - page 9

    C2623M (2/0 7) 9 OPTIONAL ACCESSORIES The following optional a ccessories are available: WM5001-3U Wall mount base ki t for single-width module WM5001-3UEXP Wall mount expansion kit for single-width module RK5000-3U 19-inch rack mount chassis for 14 slots (no power), 3 RUs RK5000PS-3U 19-inch rack mount chassi s for 12 slots with power , 3 RUs EPS5 ...

  • Pelco FR82041 - page 10

    10 C2623M (2/07) REAR PANEL Figure 3 illustrates the rear pa nel of the F T82041 and FR82041 modules. Figure 3. Rear Panel of F T82041 and FR82041 Mo dules (SC Fiber Connector Shown) For additional information about r ear -panel connections, refer to Installation on page 11. For detailed information about the RJ-45 LEDs, refer to T roubleshooting o ...

  • Pelco FR82041 - page 11

    C2623M (2/0 7) 11 Installation PACKAGE CONTENTS The following it ems are supplied: 1 F T82041 or FR82041 module 1 Regulated switching power suppl y with four plug adapt ers (North American, Australian, U.K., and European configurations); 100-240 V A C, 50-60 Hz input, 12 VDC output 1 Wall clip with two 4-40 x 0.250-inch Phillips pa n head screws wi ...

  • Pelco FR82041 - page 12

    12 C2623M (2/07) Using the TX Mode switch for a parti cular port, y ou can do the following: • Enable autonegotiation or select (force) a specific data rate and duplex mode: – Enabling autonegotiation allows the F T82041/FR82041 module to automatically negotiate with the device to which the port is connected for data rate and duplex modes of op ...

  • Pelco FR82041 - page 13

    C2623M (2/0 7) 13 NOTE: TX Mode configuration must be set when the module is powered off. If you wish to change a TX Mode switch setting after the module has been powered on, power of f the module, change the TX Mode switch setting, and then power on the module again. MOUNTING The F T82041/FR82041 module can be mounted into a ra ck or can be used a ...

  • Pelco FR82041 - page 14

    14 C2623M (2/07) Mounting the F T82041/FR82041 Module Using the Wall Clip NOTE: Before mounting the F T82041/FR82041 module to a wall, ensure that there is adequate space at both ends for viewing the fr ont-panel LEDs and for making the various rear-pa nel cable connec- tions. T o attach the F T82041/FR82041 module to a wall usi ng the supplied wal ...

  • Pelco FR82041 - page 15

    C2623M (2/0 7) 15 CONNECTIONS Connections to the F T82041/FR82041 module are made on the rear panel of the unit (refer to Figure 6). Figure 6. F T82041/FR82041 Module Connecti ons As illustrated in Figure 6, F T82041/FR82041 connections consist of the following: • Power connection NOTES: – A 12 VDC or 24 VA C power supply can be us ed to power ...

  • Pelco FR82041 - page 16

    16 C2623M (2/07) • Fiber connection NOTE: Fiber port A of the F T82041 module connects to fiber port B of the FR82041 module or of any other Pelco Ethernet sw itch that supports wavelength division multiplexing (WDM). Similarly , fiber port B of the FR82041 module connects to fiber port A of the F T82041 module or of any other Pelco Ether net swi ...

  • Pelco FR82041 - page 17

    C2623M (2/0 7) 17 T roubleshooting LED indicators on the front and rear panels of the F T82041/FR82041 module allow you to monitor operational status: • LED indicators on the front panel allow you to monitor operating power , 100BASE-FX port status, and optic signal/l aser status. Refer to T able B fo r information about the front-panel indicator ...

  • Pelco FR82041 - page 18

    18 C2623M (2/07) Optic Fault LED ( ) Green The optical signal is being received and laser is operating properly . — No action is required. Red The optical signal is not being received. Remote module is not powered on. Check power connections. Replace power supply if necessary . Fiber optic cable is not connected. Check fiber optic connec- tions. ...

  • Pelco FR82041 - page 19

    C2623M (2/0 7) 19 T able C. T roubleshooting with Rear -Panel Indicators Indicator Color Meaning Possibl e Cause Corrective Action RJ-45 10BASE-T/100BASE-TX Port Stat us LED - Left (Link / Activity) Amber A 10BASE-T link is established. — If 10BASE-T operation is desired, no action is required. If 10BASE-T operation is not desired, refer to Setti ...

  • Pelco FR82041 - page 20

    20 C2623M (2/07) RJ-45 10BASE-T/100BASE-TX Port Status LED - Left (Link/Activity) (Continued) Not lit A 10BASE-T or 100BASE-TX link cannot be estab- lished. A problem may exist with the cable: • Cable is not connected to the module or to the 10BASE-T/100BASE-TX compatible device. • Cable is defective. • Cable is not the proper cable type. • ...

  • Pelco FR82041 - page 21

    C2623M (2/0 7) 21 RJ-45 10BASE-T/100BASE-TX Port St atus LED - Right (Duplex/Collision) Amber Port is set to 10BASE-T full- duplex mode. — If 10BASE-T full-duplex opera- tion is desired, no action is required. If 10BASE-T full- duplex operation is not desired, refer to Setting 10BASE-T/100BASE-TX Port Modes of Operation on page 11 for information ...

  • Pelco FR82041 - page 22

    22 C2623M (2/07) RJ-45 10BASE-T/100BASE-TX Port Status LED - Right (Duplex/Co llision) (Continued) Green Port is set to 100BASE-TX full- duplex mode. — If 100BASE-TX full-duplex operation is desired, no action is required. If 100BASE-TX full-duplex operation is not desired, refer to Setting 10BASE-T/100BASE-TX Port Modes of Operation on page 11 f ...

  • Pelco FR82041 - page 23

    C2623M (2/0 7) 23 RJ-45 10BASE-T/100BASE-TX Port Status LED - Right (Duplex/Co llision) (Continued) Not lit Port is set to 10BASE-T half- duplex mode and no collisions are detected.* — If 10BASE-T half-duplex operation is desired, no action is required. If 10BASE-T half- duplex operation is not desired, refer to Setting 10BASE-T/100BASE-TX Port M ...

  • Pelco FR82041 - page 24

    24 C2623M (2/07) Specifications PERFORMANCE Switch T ype Unmanaged Layer 2 Switch Method Store and forward Switch Fabric Non-head-of-line blocking Data Rate 10/100 Mbps Compliance IEEE 802.3, 802.3u, 802.3x Interface Auto MDI/MDI-X Operating Mode Full- duplex or half-duplex Address T able Size 1,024 MAC address ent ries with automatic learning and ...

  • Pelco FR82041 - page 25

    C2623M (2/0 7) 25 OPTICAL POWER BUDGET AND MAXI MUM TRANSMISSION DIST ANCE Model Number Wavelength (T ransmit/Receive)* Optical Power Budget Maximum T ransmission Distance T ransmitter End Receiver End Fiber Port A Fiber Port B Multimode (62.5/125 μm) F T82041MSTR-1 FR82041MSTR-1 1310/850 nm 850/1310 nm 26 dB † 2 km (1.2 mi) ‡ F T82041MSCR-1 F ...

  • Pelco FR82041 - page 26

    26 C2623M (2/07) Appendix. RJ-45 Connector Pinouts Figure 7 illustrates RJ-45 MDI/MDI-X connector pinouts. Figure 7. RJ-45 MDI/MDI-X Connector Pinouts T able D summarizes RJ-45 MDI/MDI-X connector pinouts. T able D. RJ-45 MDI/MDI-X Connector Pinouts Pin Number MDI (Normal Mode) MDI-X (Crossed Mode) 1R X + T X + 2R X - T X - 3 TX+ RX+ 4 Not used Not ...

  • Pelco FR82041 - page 27

    PRODUCT WARRANTY AND RETURN INFORMATION WARRANTY Pelco will repair or replace, without charge, any merc handise pr oved defective in mate rial or work manship for a period of one year after the date of shipment. Exception s to this warranty are as noted below: • Five years on fiber o ptic products and TW3 000 Series unshield ed twisted pair tr an ...

  • Pelco FR82041 - page 28

    ® Worl dwide Headquarters 3500 Pelco W ay Clovis, California 93612 USA USA & Canada T el: 800/289-9100 Fax: 800/289-9150 International T el: 1-559/292-1981 Fax: 1-559/348-1120 www .pelco.com ISO 9001 Australia | Canada | Finland | France | Germany | Italy | Macau | The Netherlands | Russia | Singapore South Africa | Spain | Sweden | United Ara ...

Fabricant Pelco Catégorie Switch

Les documents que nous recevons du fabricant de l'appareilPelco FR82041 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Pelco
- manuels d’utilisations FR82041
- fiches produit Pelco
- dépliants
- ou étiquettes-énergie Pelco FR82041
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Pelco FR82041.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Pelco FR82041, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Pelco FR82041. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Pelco FR82041.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Pelco FR82041, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Pelco FR82041 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Pelco FR82041.

Le manuel d’utilisation complet Pelco, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Pelco FR82041 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Pelco FR82041, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lPelco FR82041 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Pelco FR82041 - qui devraient nous aider dans les premières étapes lors de l'utilisation Pelco FR82041
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Pelco FR82041
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Pelco FR82041 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Pelco FR82041?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Pelco FR82041, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Pelco FR82041 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)