    Owners Manual FOR POTABLE WATER HEATING ONLY NOT SUITABLE FOR SPACE HEATING NOT FOR USE IN MOBILE HOMES Model No. L53.335816 40 Gal. 153.335845 40 Gal. High Altitude L.R 153.335862 40 GaL. L.R 153.335916 50 Gal. 153.335942 50 Gal. High Altitude L.R 153.335962 50 Gal. L.R Caution: Read and Follow All Safety Rules and Operating Instructions Before Fi ...

  • Kenmore Power Miser 9 153.335916 - page 2

    Safety Precautions &`WARNIN__G Improper installation, adjustment, alteration, service or maintenance can cause death, serious bodily injury, or property damage. Refer to this manual for assistance or consult your local Sears Service Center for further I information. _,WARNING WATER HEATERS EQUIPPED FOR ONE TYPE GAS ONLY: This water heater is eq ...

  • Kenmore Power Miser 9 153.335916 - page 3

    Safety Precautions AWARNING A gas water heater cannot operate properly without the correct amount of air for combustion. Do not install in a confined area such a closet, unless you provide air as shown in the "Locating The New Water Heater" section. Never obstruct the flow of ventilation air. If you have any i doubts or questions at all c ...

  • Kenmore Power Miser 9 153.335916 - page 4

    Safety Precautions _,WARNING I The water heater wi_talled must be prep- I erly vented to a chimney which terminates outdoors. I Never operate the water heater unless it is vented to the outdoors and has adequate air supply to avoid risks of improper operation, explosion or asphyxiation. AWARNING Hinimum clearances between the water heater and com- ...

  • Kenmore Power Miser 9 153.335916 - page 5

    Table of Contents c c...-..oal_y Precautions ............................................................................................................................................ 2-4 Table of Contents .............................................................................................................................................. ...

  • Kenmore Power Miser 9 153.335916 - page 6

    Customer Responsibilities Thank You for purchasing a Sears water heater. Properly instaRled and maintained, it should give you years of trouble free ser- vice. If you should decide that you want the new water heater profes- sionally installed by Sears call the local Sears Service Center or any Sears store. They will arrange for prompt, quality inst ...

  • Kenmore Power Miser 9 153.335916 - page 7

    Materials and Basic Tools Needed Materials Needed To simplify the installation Sears has available the installation parts shown below. You may or may not need all of these materi- als, depending on your type of installation. Gas Water Heater I Installation _ Kit I WATER HEATER INSTALLATION KIT WITH FLEXIBLE CONNECTORS FOR 3/4" GALVANIZED OR I/ ...

  • Kenmore Power Miser 9 153.335916 - page 8

    Installation Instructions Removing the Old Water Heater Turn "OFF" the gas supply to the water heater. _,WARNING If the main gas line shutoff serving all gas appliances is I used, also shut "off" the gas at each appliance. Leave all gas appliances shut "off" until the water heater installation s comp ete. Turn water to ...

  • Kenmore Power Miser 9 153.335916 - page 9

    Installation Instructions Locating the New Water Heater You should carefully choose an indoor location for the new water heater, because the placement is a very important consideration for the safety of the occupants in the building and for the most economical use of the appliance. This water heater is not for use in mobile homes or outdoor install ...

  • Kenmore Power Miser 9 153.335916 - page 10

    Installation Instructions (cont'd) IIWARNING A gas water heater cannot operate properlywithout the cor- rect amount of air for combustion. Do not install in a con- fined area such a closet, unless you provide air as shown in the "Locating The New Water Heater" section. Never obstruct the flow of ventilationair. If you have any doubts ...

  • Kenmore Power Miser 9 153.335916 - page 11

    Installation Instructions (cont'd) Combustion Air and Ventilation for Appliances Located in Unconfined Spaces Unconfined Space is a space whose volume is not less than 50 cubic feet per 1,000 Btu per hour of the aggregate input rating of all appli- ances installed in that space. Rooms communicating directly with the space in which the applianc ...

  • Kenmore Power Miser 9 153.335916 - page 12

    Installation Instructions (cont'd) Water Piping AWARNING HOTTER WATER CAN SCALD: Water heaters are intended to Jmduce hot water. Water heated to a temperature which will satisfy clothes washing, dish washing, and other sanitizing needs can scald and permanently injure you upon contact. Some pee- fie are more likely to be permanently injured by ...

  • Kenmore Power Miser 9 153.335916 - page 13

    Installation Instructions (cont'd) Temperature-Pressure Relief Valve _,WARNING At the time of manufacture this water heater was provided with a combination temperature-pressures relief valve certified by a nationally recognized testing laboratory that maintains Jerlodlc inspection of production of listed equipment or mate- rials_ as meeting th ...

  • Kenmore Power Miser 9 153.335916 - page 14

    Installation Instructions (cont'd) Filling the Water Heater ACAUTION Never use this water heater unless it is completely filled with water. To prevent damage to the tank, the tank must be filled with water. Water must flow from the hot water faucet before turn ng ON" gas to the water heater. You must provide all wiring of the proper size ...

  • Kenmore Power Miser 9 153.335916 - page 15

    Installation Instructions (cont'd) USE WITHOUT POWER CORD (cont'd) 3. A standard ½" conduit opening has been made in the water heater junction box for the conduit connection. 4. Use wire nuts and connect the power supply wiring to the wires inside the water heater's junction box. 5. The water heater must be electrically "g ...

  • Kenmore Power Miser 9 153.335916 - page 16

    Installation Instructions (cont'd) Venting (cont'd) AWARNING of Be sure vent pipe is properlyconnected to prevent escape dangerous fluegases which could cause deadly asphyxiation. VENTING SYSTEM EXAMPLE INSTALLATIONS FOR ALL MODELS The vent piping cannot under any circumstances be run down- hill. AWARNING Chemical vapor corrosion of the f ...

  • Kenmore Power Miser 9 153.335916 - page 17

    Installation Instructions (cont'd) VENTING SYSTEM EXAMPLE INSTALLATIONS FOR ALL MODELS (cont'd) • , . i - , 2. Horizontal runs require a mmtmum¼ rtse per foot. 13" MIN. MIN. RISE 7," I I" MIN. PER FOOT I 3. A vertical run can be no more than 20'. 4. The total vertical and horizontal run cannot exceed 35'. MIN. ...

  • Kenmore Power Miser 9 153.335916 - page 18

    Installation Instructions (cont'd) Venting (cont'd) CUTTING OPENING THROUGH AN OUTSIDE WALL AND COLLAR INSTALLATION After reading the manual and you have determined the location of the opening in the wall, (using the drawing below), cut a 3_" hole through an exterior wall. NOTE: When determining location of the opening in the outside ...

  • Kenmore Power Miser 9 153.335916 - page 19

    Installation Instructions (cont'd) Gas Piping AWARNING Make sure the gas supplied is the same type listed on the model rating plate. The inlet gas pressure must not exceed 10.5 in. water column(2.6kPa) for natural gas or 13 in, water column (3.2kPa) for propane (LR) gas. The minimum inlet gas pressurelisted on the model rating plate is for the ...

  • Kenmore Power Miser 9 153.335916 - page 20

    Installation Instructions (cont'd) Installation Checklist BEFORE LIGHTING THE PILOT: VENT PIPE TO OUTDOORS • Check the gas lines for leaks. a. Use a soapy water solution. DO NOT test for gas leaks usinga match or open flame. b. Brush the soapy water solution on all gas pipes, joints and fittings. c. Check for bubbling soap. This means you ha ...

  • Kenmore Power Miser 9 153.335916 - page 21

    Operating Instructions This water heater is equipped with an electrically operated vent- ing system and a standing pilot. For the burner to come on, the water heater thermostat must call for heat. Then the system will begin sequencing, each section proving itself before gas is allowed to flow to the burner. BLOWER MOTOR BEFORE THE WATER HEATER WILL ...

  • Kenmore Power Miser 9 153.335916 - page 22

    Operating Instructions Lighting _,WARNING BEFORE LIGHTING [PROPANE (L.P.) GAS WATER HEATERS]: Propane (L.R) gas is heavier than air. Should there be a leak in the system, the gas will settle near the ground. Basements, crawl spaces, skirted areas under mobile homes (even when ventilated), closets and areas below ground level will i serve as pockets ...

  • Kenmore Power Miser 9 153.335916 - page 23

    Operating Instructions (cont'd) Lighting label on the water heater as it appears above the thermostat FOR YOUR SAFETY READ BEFORE LIGHTING I WARNING If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by han ...

  • Kenmore Power Miser 9 153.335916 - page 24

    Operating Instructions (cont'd) Temperature Regulation Due to the nature of the typical gas water heater, the water tem- _oerature in certain situations may vary up to 30°F higher or wet at the point of use such as, bathtubs, showers, sink, etc. Turn the water temperature dial clockwise (f'-_) to decrease the temperature, or counterclock ...

  • Kenmore Power Miser 9 153.335916 - page 25

    Service and Adjustment Tank (Sediment) Cleaning Sediment build-up on the tank bottom may create varying amounts of noise, and if left in the tank will cause premature tank failure. In some water areas, you may not be able to drain all sediment deposits by simply draining the tank. in these cases Mag Erad (part no. 23600) can be used to help remove ...

  • Kenmore Power Miser 9 153.335916 - page 26

    Service and Adjustment (cont'd) L.R Gas Control Valve & Burner Assembly Replacement Information Draining The water heater should be drained if being shut down during freezing temperatures. Also periodic draining and cleaning of sediment from the tank may be necessary. AWARNING PROPANE (L.R) GAS CONTROL VALVE AN BURNEI ASSEMBLYREPLACEMENT I ...

  • Kenmore Power Miser 9 153.335916 - page 27

    Service and Adjustment (cont'd) Drain Valve Washer Replacement NOTE: For replacement, use a '_2" x "/_" x Y_" thick washer available at your nearest hardware store. For ordering replace- ment washers, refer to the "Repair Parts" section. Turn "OFF" gas supply to water heater. Follow "Draining&q ...

  • Kenmore Power Miser 9 153.335916 - page 28

    Troubleshooting Guide Start Up Conditions THERMAL EXPANSION Water supply systems may, because of such events as high line pressure, frequent cut-offs, the effects of water hammer among others, have installed devices such as pressure reducing valves, check valves, back flow preventers, etc...to control these types of _roblems. When these devices are ...

  • Kenmore Power Miser 9 153.335916 - page 29

    Troubleshooting Guide (cont'd) CONDENSATION Whenever the water heater is filled with cold water, a certain amount of condensation will form while rile burner is on. A water heater may appear to be leaking when in Fact die water is condensation. This usually happens when: • When a new water heater is filled with cold water for the first time. ...

  • Kenmore Power Miser 9 153.335916 - page 30

    Troubleshooting Guide (cont'd) Operational Conditions (cont'd) "AIR" IN HOT WATER FAUCETS WATER IS TOO HOT AWARNING HYDROGEN GAS: Hydrogen gas can be produced in a hot water system that has not been used for a long period of time (generally two weeks or more). Hydrogen gas is extremely flammable and explosive. To prevent the pos ...

  • Kenmore Power Miser 9 153.335916 - page 31

    Troubleshooting Guide (cont'd) Leakage Checkpoints Use this guide to check a "Leaking" water heater. Many suspect- ed "Leakers" are not leaking tanks. Often the source of the water can be found and corrected. if you are not thoroughly familiar with your local gas codes your water heater, and safety practices, contact the Se ...

  • Kenmore Power Miser 9 153.335916 - page 32

    Troubleshooting Guide (cont'd) AWARNING ] This troubleshooting _plied for use by quail- J fled service personnel who have a complete understanding of both electricity and gas. ] A CAUTION J Label all wiring before disconnecting any wiring to ensure correct reconnectlon. Failure to follow this instruction could cause improper and possible dange ...

  • Kenmore Power Miser 9 153.335916 - page 33

    Troubleshooting Guide (cont'd) Diagram for Electrical System Check on pages 34 and 35, 120v _j ON/OFF SWITCH GAS PRESSURE SWITCH G 12OV GAS SOLENOID HI-LIMIT SW.,TCH..,C No AIR PRESSUR SWITCH INDICATOR LIGHT 120V 0 HOT NC AIR PRESSURE SWITCH GROUND 1 I I I [ ® MANUAL HI- LIMIT SWITCH _---® WHITE m m 120V GAS SOLENOID GASPRESSURE MANIFOLO NAT ...

  • Kenmore Power Miser 9 153.335916 - page 34

    Troubleshooting Guide (cont'd) ELECTRICAL SYSTEM CHECK (Use diagram on page 33) A CAUTION J Label all wiring before disconnecting any wiring; to ensure I correct reconnection. Failure to follow this instruction J could cause improper and possible dangerous operation, resulting in DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE. No i i i i i C ...

  • Kenmore Power Miser 9 153.335916 - page 35

    Troubleshooting Guide (cont'd) Check #5 to ground for 110/120 __ volts. Yes 1 [Chock 9 orl 0,120volts. ] No Yes Check venting manual reset switch. I Replace thermostat. continued from facing page 1 No -fCheck#8togroundfor110/120volts.]-.,_--No -j Is indicator light on? [ I Yes I Replace indicator light. Secure air pressure line. Replace air pr ...

  • Kenmore Power Miser 9 153.335916 - page 36

    Parts Order List POWER MISER TM 9 POWER VENT GAS WATER HEATERS MODEL NUMBERS: 153.335816 40 Gal. 153.335845 40 Gal. High Altitude L.P. 153.335862 40 Gal. L.P. 153.335916 50 Gal. 153.335942 50 Gal. High Altitude L.P. 153.335962 50 Gal. L.P. 5 13 36 ...

  • Kenmore Power Miser 9 153.335916 - page 37

    Parts Order List (cont'd) POWER MISER TM 9 POWER VENT GAS WATER HEATERS MODEL NUMBERS: 153.335816 40 Gal. 153.335845 40 Gal. High Altitude L.P. 153.335862 40 Gal. L.P. 153.335916 50 Gal. 153.335942 50 Gal. High Altitude L.P. 153.335962 50 Gal. L.P. KEY NO. PART DESCRIPTION 1. Vent Cap w/Screen 9001957 2. Wall Collar 9001993 3. 5' PVC Sche ...

  • Kenmore Power Miser 9 153.335916 - page 38

    Parts Order List POWER MISER TM 9 POWER VENT GAS WATER HEATERS MODEL NUMBERS: 153.335816 40 Gal. 153.335845 40 Gal. High Altitude L.P. 153.335862 40 Gal. L.P. 153.335916 50 Gal. 153.335942 50 Gal. High Altitude L.P. 153.335962 50 Gal. L.P. 5 I 31€._ I I 38 ...

  • Kenmore Power Miser 9 153.335916 - page 39

    Parts Order List (cont'd) POWER MISER TM 9 POWER VENT GAS WATER HEATERS MODEL NUMBERS: 153.335816 40 Gal. 153.335845 40 Gal. High Altitude L.P. 153.335862 40 Gal. L.P. 153.335916 50 Gal. 153.335942 50 Gal. High Altitude L.P. 153.335962 50 Gal. L.P. KEY NO. PART DESCRIPTION 24. Thermostat Adjustment Knob 25. Gas Thermostat (Nat.) 25. Gas Thermo ...

  • Kenmore Power Miser 9 153.335916 - page 40

    Warranty About Your Warranty THE PRICE OF YOUR WATER HEATER DOES NOT INCLUDE A FREE CHECKUP SERVICE CALL. On Water Heater Installations Arranged By Sears, Sears warrants the installation. ON INSTALLATIONS NOT MADE BY SEARS AUTHORIZED CONTRACTORS: 1. Your Sears warranty applies to the product only. 2. Sears does not warrant the itstailarion. 3. A c ...

Fabricant Kenmore Catégorie Water Heater

Les documents que nous recevons du fabricant de l'appareilKenmore Power Miser 9 153.335916 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Kenmore
- manuels d’utilisations Power Miser 9 153.335916
- fiches produit Kenmore
- dépliants
- ou étiquettes-énergie Kenmore Power Miser 9 153.335916
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Kenmore Power Miser 9 153.335916.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Kenmore Power Miser 9 153.335916, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Kenmore Power Miser 9 153.335916. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Kenmore Power Miser 9 153.335916.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Kenmore Power Miser 9 153.335916, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Kenmore Power Miser 9 153.335916 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Kenmore Power Miser 9 153.335916.

Le manuel d’utilisation complet Kenmore, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Kenmore Power Miser 9 153.335916 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Kenmore Power Miser 9 153.335916, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lKenmore Power Miser 9 153.335916 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Kenmore Power Miser 9 153.335916 - qui devraient nous aider dans les premières étapes lors de l'utilisation Kenmore Power Miser 9 153.335916
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Kenmore Power Miser 9 153.335916
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Kenmore Power Miser 9 153.335916 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Kenmore Power Miser 9 153.335916?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Kenmore Power Miser 9 153.335916, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Kenmore Power Miser 9 153.335916 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)