  • National Instruments NI PXI/PCI-5114 - page 1

    NI PXI/PCI-5114 Specifications 8-Bit 250 MS/s Digitizer Unless otherwise noted, the followi ng conditions were used for each specification: • All filter settings • All impedance selections • Sample clock set to 250 MS/s T ypical values are representati ve of an av erage unit operating at room temperature. Specifications are subject to change ...

  • National Instruments NI PXI/PCI-5114 - page 2

    NI PXI/PCI-5114 Specifications 2 ni.com Power .............. .................... ................ .................... .................... .............14 Software .................. .................... .................... .................... ................... .. 15 Environment .............. .................... .................... ....... ...

  • National Instruments NI PXI/PCI-5114 - page 3

    © National Instruments Corporat ion 3 NI PXI/PCI-5 114 Specifications Voltage Levels Full Scale (FS) Input Range and Programmable V ertical Of fset 50 Ω 1 M Ω — Range (V pk-pk ) V ertical Of fset Range (V) Range (V pk-pk ) V ertical Offset Range (V) 0.04 ±0.8 0.04 ±0.8 0.1 ±0.8 0.1 ±0.8 0.2 ±0.8 0.2 ±0.8 0.4 ±0.8 0.4 ±0.8 1 ±6.5 1.0 ? ...

  • National Instruments NI PXI/PCI-5114 - page 4

    NI PXI/PCI-5114 Specifications 4 ni.com Figure 1. NI 5114 Frequency Response (T ypical) Bandwidth and Transient Response Bandwidth (–3 dB) Range (V pk-pk ) Bandwidth Rise/F all T ime, T ypical — All ranges except 0.04 125 MHz 2.8 ns 0.04 100 MHz 3.5 ns Bandwidth Limit Filter 20 MHz Noise Filter — A C Coupling * Cutof f (–3 dB), T ypical 12 ...

  • National Instruments NI PXI/PCI-5114 - page 5

    © National Instruments Corporat ion 5 NI PXI/PCI-5 114 Specifications Specif ication Va l u e Commen ts Spectral Characteristics Spurious Free Dynamic Range with Harmonics (SFDR), T ypical Range (V pk-pk ) 10 MHz, –1 dBFS input signal. Includes the 2 nd through the 5 th harmonics. Measured from DC to 125 MHz. 20 MHz bandwidth limit filter of f. ...

  • National Instruments NI PXI/PCI-5114 - page 6

    NI PXI/PCI-5114 Specifications 6 ni.com Horizontal Sample Clock Specification Va l u e Comments Sources Internal, Onboard Clock (i nternal VCXO)* External, CLK IN (front panel SMB connector) * Internal Sample Clock is locked to the Reference Clock or deri ved from the onboard VCXO. Onboard Clock (Internal VCXO) Sample Rate Range Real-T ime Sampling ...

  • National Instruments NI PXI/PCI-5114 - page 7

    © National Instruments Corporat ion 7 NI PXI/PCI-5 114 Specifications Phase-Locked Loo p (PLL) Reference Clock External Sample Clock Sources CLK IN (front panel SMB connector) — Frequenc y Range 50 MHz to 250 MHz Di vide by n decimation av ailable where 1 ≤ n ≤ 65,535. For more informati on about Sample Clock and decimation, refer to the NI ...

  • National Instruments NI PXI/PCI-5114 - page 8

    NI PXI/PCI-5114 Specifications 8 ni.com CLK IN (Sample Clock and Reference Clock Input, Front Panel Connector) T r igger Reference (Stop) T rigger Specification Va l u e Comments Input V oltage Range Sine wav e: 0.65 V pk-pk to 2.8 V pk-pk (0 dBm to 13 dBm) Square wav e: 0.2 V pk-pk to 2 .8 V pk-pk — Maximum Input Overload 7 V rms with | Peaks | ...

  • National Instruments NI PXI/PCI-5114 - page 9

    © National Instruments Corporat ion 9 NI PXI/PCI-5 114 Specifications Analog Trigger (Edge, Window, and Hysteresis Trigger Types) Sources CH 0 (front panel BNC connector) CH 1 (front panel BNC connector) TRIG (front panel BNC connector) — T rigger Level Resolution 8 bits (1 in 256) T rigger Level Range CH 0, CH 1 TRIG (External Trigger) — 100% ...

  • National Instruments NI PXI/PCI-5114 - page 10

    NI PXI/PCI-5114 Specifications 10 ni.com TRIG (External T rigger , Front Panel Connector) PFI 0 and PFI 1 (Programmable Function Interface, AUX Front Panel Connectors) T ypes Specific Line Any Line Specific Field — Standards SDTV : M-NTSC, B/G-P AL, SECAM, M-P AL EDTV : 480i/59.94 fps, 480i /60 fps, 480p/59.94 Fps, 480p/60 Fps, 576i/50 fps, 576p/ ...

  • National Instruments NI PXI/PCI-5114 - page 11

    © National Instruments Corporat ion 11 NI PXI/PCI-5 114 Specifications As an Input (Trigger) Destinations Start T rigger (Acquisition Arm) Reference (Stop) T rigger Arm Referen ce Advance T rigger — Input Impedance 150 k Ω — V IH 2.0 V — V IL 0.8 V — Maximum Input Overload –0.5 V to 5.5 V — Maximum Frequency 25 MHz — As an Output (E ...

  • National Instruments NI PXI/PCI-5114 - page 12

    NI PXI/PCI-5114 Specifications 12 ni.com TClk Specifications National Instruments TClk synchronizati on method and the NI-TClk driver are used to align the sample clocks on any number o f SMC-based modules in a chassis. For more inform ation about TClk synchronizati on, refer to the NI-TClk Synchronization Help , wh ich is located within the N I Hi ...

  • National Instruments NI PXI/PCI-5114 - page 13

    © National Instruments Corporat ion 13 NI PXI/PCI-5 114 Specifications W aveform Specifications Specif ication Va l u e Comments Onboard Memory Size 8 MB per Channel Standard 8 megasamples per channel — 64 MB per Channel Option 64 megasamples per channel 256 MB per Channel Option 256 megasamples per channel Minimum Record Length 1 Sample — Num ...

  • National Instruments NI PXI/PCI-5114 - page 14

    NI PXI/PCI-5114 Specifications 14 ni.com Calibration Power Specification Va l u e Comments Self-Calibrati on Self-calibration i s done on soft ware command. The calibration corrects for gain, of fset, compensated 1 M Ω attenuat or , triggering, and timing adjustment errors fo r all input ranges. — External Calibration (Factory Calibration) The e ...

  • National Instruments NI PXI/PCI-5114 - page 15

    © National Instruments Corporat ion 15 NI PXI/PCI-5 114 Specifications Software Specification Va l u e Comm ents Dri ver Software NI PXI-5114 : NI-SCOPE 2.9 or later . NI PCI-5114 : NI-SCOPE 3.1 or later . NI-SCOPE is an IVI-complian t dri ver that allo ws you to configure, control, and calib rate the NI 5114. NI-SCOPE provides application program ...

  • National Instruments NI PXI/PCI-5114 - page 16

    NI PXI/PCI-5114 Specifications 16 ni.com Environment NI PXI-5114 Note T o ensure that the NI PXI-5114 cools ef fectiv ely , follow the guidelines in the Maintain Forced Air Cooling Note to Users included in the NI PXI-5114 kit. The NI PXI-5114 is intended for indoor use only . Specif ication Va l u e Comments Operating T emperature 0 ºC to +55 ºC ...

  • National Instruments NI PXI/PCI-5114 - page 17

    © National Instruments Corporat ion 17 NI PXI/PCI-5 114 Specifications NI PCI-5114 Note T o ensure that the NI PCI-5114 cools ef fectiv ely , follo w the guidelines in the Maintain Forced Air Cooling Note to Users included in the NI PCI-5114 kit. Also , to maximize airflo w and extend the life of the de vice, leave an y adjacent PCI slots empty . ...

  • National Instruments NI PXI/PCI-5114 - page 18

    NI PXI/PCI-5114 Specifications 18 ni.com Safety , Electromagnetic Compatibility , and CE Compliance Specification Va l u e Comm ents Safety The NI 5114 meets the requirements of the following standards of safety for electri cal equipment for measurement, control, and laboratory use: • IEC 61010 -1, EN 6101 0-1 • UL 61010-1, CAN/CSA-C22.2 No. 61 ...

  • National Instruments NI PXI/PCI-5114 - page 19

    © National Instruments Corporat ion 19 NI PXI/PCI-5 114 Specifications Physical Specification Va l u e Comments Dimensions NI PXI-5114 NI PCI-5114 — 3U, One slot, PXI/cPCI Module 21.6 × 2.0 × 13.0 cm (8.5 × 0.8 × 5.1 in.) 35.5 × 2.0 × 11.3 cm (13.4 × 0.8 × 4.4 in.) We i g h t 455 g (16 oz) 421 g (1 4.8 oz) — Front Panel Connectors Labe ...

  • National Instruments NI PXI/PCI-5114 - page 20

    National Instruments, NI, ni.com, and LabVIEW are tradem arks of National Instruments Corporation. Refer to t he Terms of Use section on ni.com/legal for more inform ation about Natio nal Instruments trademarks. Other product and company names mentioned herein are trademarks or trad e names of their respective companies. For patents covering Nation ...

Fabricant National Instruments Catégorie Computer Hardware

Les documents que nous recevons du fabricant de l'appareilNational Instruments NI PXI/PCI-5114 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques National Instruments
- manuels d’utilisations NI PXI/PCI-5114
- fiches produit National Instruments
- dépliants
- ou étiquettes-énergie National Instruments NI PXI/PCI-5114
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation National Instruments NI PXI/PCI-5114.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation National Instruments NI PXI/PCI-5114, manuels d’entretien, brefs manuels ou manuels de l’utilisateur National Instruments NI PXI/PCI-5114. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit National Instruments NI PXI/PCI-5114.

Manuel d’utilisation complet de l’appareil National Instruments NI PXI/PCI-5114, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser National Instruments NI PXI/PCI-5114 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs National Instruments NI PXI/PCI-5114.

Le manuel d’utilisation complet National Instruments, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel National Instruments NI PXI/PCI-5114 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières National Instruments NI PXI/PCI-5114, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lNational Instruments NI PXI/PCI-5114 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil National Instruments NI PXI/PCI-5114 - qui devraient nous aider dans les premières étapes lors de l'utilisation National Instruments NI PXI/PCI-5114
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de National Instruments NI PXI/PCI-5114
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service National Instruments NI PXI/PCI-5114 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de National Instruments NI PXI/PCI-5114?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec National Instruments NI PXI/PCI-5114, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec National Instruments NI PXI/PCI-5114 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)