    Model 1812 Plus Residential Telephone Intercom / Access Control System Owner’s Manual DoorKing, Inc. 120 Glasgow Avenue Inglewood, California 90301 U.S.A. Phone: 310-645-0023 Fax: 310-641-1586 www.doorking.com P/N 1812-161 REV E, 1/10 Copyright 2009 DoorKing, Inc. All rights reserved. ...

  • DoorKing 1812 PLUS - page 2

    Page 2 1812-161-E-1-10 ...

  • DoorKing 1812 PLUS - page 3

    Use this manual with the following models only . 1812-Plus Residential Tele phone Intercom / Access Control System with circuit board 1971 -0 10. DoorKing, Inc. reserves t he right to make chang es in the products described in thi s manual without notice and without obligation of DoorKing, In c. to notify any persons of any such revisions or change ...

  • DoorKing 1812 PLUS - page 4

    Table of Contents Preface Important Notices .............................................................................................................. ........................................6 General Information ..................................................................................................................................... ...

  • DoorKing 1812 PLUS - page 5

    2.4 Devices 2.4.1 Simple Access Code Programming ......................................................................................... 30 2.4.2 Access Code Programming .................................................................................................. ... 30 2.4.3 Delete Access Codes .............................................. ...

  • DoorKing 1812 PLUS - page 6

    Important Notices FCC – United States This equipment has been tested and found to comply with the limits for a cla ss A digital device, pursuant to Part 15 of the FCC Rules and Reg ula tions. These limits are designed to provide reasonable protectio n against harmful interferen ce when the equipment is operated in a commercial environment. This e ...

  • DoorKing 1812 PLUS - page 7

    General Information • Prior to beginning the in stallation of the teleph one entry system, we suggest that you become familiar with the instruction s, illustrations, and wiring guidelines in t his manual. This will help insure that you installation is perform ed i n an efficient and professio nal man ner. • The proper installation of the teleph ...

  • DoorKing 1812 PLUS - page 8

    Features • Unique telephone commu nication system allows ho meowners to use their tel ephone as an intercom to speak to a guest at a front door or gate, and to control acce ss to their property. • Unique distinctive ring. • Unit connects dire ctly to the homeowners existing telepho ne line. No additional monthl y expense for a second telephon ...

  • DoorKing 1812 PLUS - page 9

    SECTION 1 - INST ALLA TION Installation of the 1812 Plus Telephone Entry System involves the installation of the hardware and by- pass switch, and the wiring of these components. If used to control a vehicular gate w ith an automatic gate oper ator, the telephone entry system must be mounted a minimum of ten (10) feet away from the gate and gate op ...

  • DoorKing 1812 PLUS - page 10

    1.2 Mount the By-Pass Switch The 1812’s by-pass swit ch provides a method to remove the 1812 from t he telephone line and reconnect the homeo wner’s telephone to the telep hone system. The By -Pass switch IS NOT optional – it must be installed as part of th e 18 12 system. All telephone wiring for the 1812 must pass through the by-pass s witc ...

  • DoorKing 1812 PLUS - page 11

    1.3 Dimensions Surface Mount 1 # 0 * 7 8 9 6 5 4 3 2 10.0 5.25 2.875 6.125 3.0 5.0 2.5 2.5 .875 1.25 1.31 .875 Dia Surface Mount Curved 11.0 6.25 6.75 3.375 5.5 2.5 2.5 1 # 0  789 6 5 4 3 2 .875 .875 1812-161-E-1-10 Page 11 ...

  • DoorKing 1812 PLUS - page 12

    Flush Mount Rough-in Box 10.25 7.5 4.5 3.5 5.0 2.625 1.25 Dia Flush Mount 123 6 5 4 9 8 7 # 0 * 9.25 12.0 4.25 3.5 .875 Dia 7.25 6.25 10.0 2.5 5.0 Page 12 1812-161-E-1-10 ...

  • DoorKing 1812 PLUS - page 13

    Wall Mount 10.75 3.5 7.375 1 2 3 6 5 4 9 8 7 # 0 * 2.5 2.5 1.125 1812-161-E-1-10 Page 13 ...

  • DoorKing 1812 PLUS - page 14

    1.4 Telephone Line Wiring Be sure to observe electrical safety when work ing wit h phon e line s. Phone lines carry electricity and the ring voltage can deliver a substantia l jolt. The best policy is to disconnect the house phon e from the phone company Network Interface Device (also kn own as ‘Demarcation Device’ ) before working on the wirin ...

  • DoorKing 1812 PLUS - page 15

    TELEPHONE LINE WIRING WIRE SIZE MAX DISTANCE IN FEET 24 AWG 800 22 AWG 1600 20 AWG 2200 18 AWG 3600 1.5 Power Wiring Do not run telephone lines and high voltage lines in the same conduit. Separate high volt age and telephone line conduits by at least six (6) in ches. POWER WIRING WIRE SIZE MAX DISTANCE IN FEET 18 AWG 100 16 AWG 200 The 1812 Plus sy ...

  • DoorKing 1812 PLUS - page 16

    1.7 Wiring for a Single Unit – Telephone Mode DOORKING 1875-010 GND ENTRY BY-PASS 12345678 C.O. PH IN PH OUT HOME 16.5 VAC 20 VA Mag Lock Power DOORKING, IN C., INGLEWOOD , CA 903 01 Date: Dwg. No. Rev. Title : 6/09 B M1812P-0 01 1812 Plus – single system. Basic wire connections. 2 Magnetic locks or electric s trikes must be powered from a sepa ...

  • DoorKing 1812 PLUS - page 17

    1.8 Wiring for Multiple Units – Telephone Mode DOORKING 1875-010 GND ENTRY BY-PASS 12345678 C.O. PH IN PH OUT HOME DOORKING, IN C., INGLEWOOD , CA 903 01 Date: Dwg. No. Rev. Title : 6/09 B M1812P-0 02 1812 Plus – multiple system s . Basic wire connections. 2 1 7 3 16.5 VAC 20 VA Mag Lock Power Mag Lock Power 16.5 VAC 20 VA 7 7 6 4 6 5 2 See dra ...

  • DoorKing 1812 PLUS - page 18

    1.9 Wiring for Single U nit – Intercom Mode DOORKING, IN C., INGLEWOOD , CA 903 01 Date: Dwg. No. Rev. Title : 2/09 A M1812P-0 03 1812 Plus – single system. Basic wire c onnections intercom m ode . 3 5 A When connected directly to a single telephone or an un- used C.O. port on a PBX or KSU system, use the PHONE OUT terminals only. The 1812 must ...

  • DoorKing 1812 PLUS - page 19

    1.10 Wiring for Multiple Units – Intercom Mode DOORKING, IN C., INGLEWOOD , CA 903 01 Date: Dwg. No. Rev. Title : 2/09 A M1812P-0 04 1812 Plus – multiple system s . Basic wire c onnections intercom m ode . 3 2 A A Connect the PHONE OUT terminals directly to home telephone or an un-used C.O. port on a PBX or KSU system. Connect the PHONE IN term ...

  • DoorKing 1812 PLUS - page 20

    1.11 Main Terminal Description Terminal Description 1 Phone In (Negative) 2 Phone In (Positive) 3 Ground 4 Phone Out (Positive) 5 Phone Out (Negative) 6 Not Used. 7 Switch Input Relay 1. A switch closure ac ross terminals 7 & 9 will activate relay 1 for its programm ed st rike time. 8 Switch Input Relay 2. A switch closure ac ross terminals 8 & ...

  • DoorKing 1812 PLUS - page 21

    SECTION 2 – PROGRAMMING Before You Start The 1812 has been programmed at the facto ry with m any of the programming parameters alre ady set (default setting) for a typical residential a pplication wit h a single 1812. There is no nee d to re program these parameters unless y ou wa nt to change them. For easy referen ce, refe r to the cha rt on th ...

  • DoorKing 1812 PLUS - page 22

    Programming Guide Table System Parameters Section 2. 2 Description Command Section Default Value Phone / Intercom Mode * 0 6 2.2.1 Phone Single / Multiple Systems * 6 1 2.2.2 Single System Attention Number * 6 2 2.2.3 7 Single or Double Ring * 6 3 2.2.4 Double Number of Rings to Resident * 6 4 2.2.5 5 Talk Time * 0 8 2.2.6 60 Sec. Relay Strike Time ...

  • DoorKing 1812 PLUS - page 23

    IMPORTANT! We strongly suggest that you read these programming instructions in their entirety before beginning any programming of this telephone entry system. The DoorKing 1812-Plus Telep hon e Intercom System can be programmed by the followi ng methods. • KEYPAD : The keypad on the front of the entry syst em can be used to program all features i ...

  • DoorKing 1812 PLUS - page 24

    2.2 System Parameter Progr amming 2.2.1 Phone / Intercom Mode Default setting is 1 (Phone Mode). The 1812 is normally co nnected in series with a re sident’s incoming phone l ine, which supplie s a constant source of DC vo ltage. When the 1812 is con nected in this manner, program the unit for PHONE mode. If the 1812 is to be conne cted to an ope ...

  • DoorKing 1812 PLUS - page 25

    2.2.5 Number of Rings to Ring Residence Default setting is 05 (5 Rings) . When the CALL button on the 1812 is push ed, th is programming sequence sets the number of unanswered rings to the house before the 1812 hang s up. 1. Press * 6 4 and then enter the MASTER CODE. [ * 6 4 _ _ _ _ (beep)] 2. Enter the number of rings befor e 181 2 hangs up (01-9 ...

  • DoorKing 1812 PLUS - page 26

    2.2.8 Tone Open Numbers Default setting for Relay 1 is 9876. Default settin g for Relay 2 is 5432. These steps will program the tone open numb er(s) for both relay 1 and relay 2 (each relay is programmed independ ently). You will need to enter a f our-digit number (see chart below) to set each relay. If a function is not desired, e nter # in place ...

  • DoorKing 1812 PLUS - page 27

    2.2.10 Hang Up Tone Default setting is 0. These steps set the number that will ha ng-up the 1812 after the conversatio n is completed. The hang up tone is used when a call from the 1812 has been forwarded to an outside number. Once the conversation has en ded, the hang up to ne number sh ould be pressed; otherwise the 1812 will rem ain on the line ...

  • DoorKing 1812 PLUS - page 28

    2.2.13 Set Call Forwarding Microphone Gain and Speaker Volume Default setting is 71. This adjustment is required only if call forwarding in the 1812 is being use d. This step will adjust the microphone gain (the remo te handset loudness) and the speaker volume (the 1812 loud ness) during call forwarding operation. You may have to perform these step ...

  • DoorKing 1812 PLUS - page 29

    2.3 Directory Codes 2.3.1 Directory Codes 24 – 50 Dial Phone Number The 1812 has the capabil ity of operating as an auto-dialer syste m and can store up to 27 phone numbers in its memory. When a visitor enters a di rectory code o n the syst em keypad, the 1812 will call the phone num ber programmed under the specif ic directory code number. The d ...

  • DoorKing 1812 PLUS - page 30

    2.4 Devices 2.4.1 Simple Access Code Programming This programming sequen ce programs simpl e access codes into the syst em memory. Simpl e access codes cannot be time zone restricted; they ca n only be assigne d to operate either relay 1 or relay 2 on a 24/7 basis. If you require access codes to be tim e zone restricted, use the programming sequenc ...

  • DoorKing 1812 PLUS - page 31

    2.4.4 Delete All Access Codes This programming sequen ce deletes all access cod es. WARNING: Once started, all access codes will be erased. 1. Press * 7 2 and enter the MASTER CODE. [ * 7 2 _ _ _ _ (beep)] 2. Press 2 *. [ 2 * (beep)] 3. Press 9 9 9 9 then press *. [ 9 9 9 9 * (beep)] 4. The programming s equence will end itse lf automatically. [bee ...

  • DoorKing 1812 PLUS - page 32

    2.5 Time Functions 2.5.1 Program Calendar Chip This programming sequen ce programs the calendar ch ip in the 18 12 system for the current ti me and date. The calendar chip must be prog ra mmed if any of the time related features are going to be used. Note: The clock / calendar chip in the 1812 Plus will keep time for app roximately 48 hours if powe ...

  • DoorKing 1812 PLUS - page 33

    2.5.3 Call Forward Phone Number Programming These steps progra m the call forwarding telephone number into the 181 2 memory. Call forwarding can only be used when the 1812 is p ro grammed in p hone mode (see 2.2.1). 1. Press * 1 0 and enter the MASTER CODE. [ * 1 0 _ _ _ _ (beep)] 2. Enter the phone number where call s fro m the 1812 are to be forw ...

  • DoorKing 1812 PLUS - page 34

    2.5.5 Relay Hold Schedule Default setting in step 3 is 0 (Hold schedules ar e OFF). This program sequen ce sets up schedules to autom at ically activate and deactivate relays 1 and 2 on the control board. Four schedules can be programmed, ea ch of which ca n be assigned to the desired relay(s). These schedules can be independently tu rned on or off ...

  • DoorKing 1812 PLUS - page 35

    2.5.6 Time Zones Default setting in step 3 is 0 (Time Zones are OFF). This programming seque nce sets up time zones (up to 4) that can be applie d to the access codes programmed into the 18 12. These time zones can b e turned on or off once they h ave been programmed. 1. Press * 3 6 and enter the MASTER CODE. [ * 3 6 _ _ _ _ (beep)] 2. Enter a time ...

  • DoorKing 1812 PLUS - page 36

    2.6 Miscellaneous 2.6.1 Restore Defaults This step will restore the factory set default s for each of the pr ogramming parameters. WARNING: Once started, this sequence will program all valu es to factory default. 1. Press * 9 0 and enter the MASTER CODE. [ * 9 0 _ _ _ _ (beep)] 2. Press 9 9 9 9 then press *. [ 9 9 9 9 * (beep)] 3. This sequence wil ...

  • DoorKing 1812 PLUS - page 37

    SECTION 3 – ADJUSTMENTS Speaker Volume The speaker volume potentiometer is labeled SPEAKER VOL on the cont rol board. The speaker volume should be adjusted for adequat e sound. Adju sting the speaker volum e too loud could cause feedback from the microphone. 1. Open the front of the telephone entry system and locat e the spe aker volume adjustmen ...

  • DoorKing 1812 PLUS - page 38

    Page 38 1812-161-E-1-10 ...

  • DoorKing 1812 PLUS - page 39

    SECTION 4 – USER INSTRUCTIONS 4.1 Resident Operating Instructions 4.1.1 Granting or Denying a Guest Access To place a call from the 1812 to the re sident’s house, the guest simply presses the PUSH TO CA LL button located on the faceplate. Once the guest has been iden tified by voice communication, the resident may grant them access by pressing ...

  • DoorKing 1812 PLUS - page 40

    4.1.3 Dial-Out Phone Numbers To use the dial-out pho ne number feature, the guest simply pre sses a two-digit directory code (24-5 0) on the system keypad. The 1812 w ill automatically dial out t he phone num ber programmed unde r the directory code that was entered on the keypa d (sec tion 2.3.1). Once the call is answered, the person called may g ...

  • DoorKing 1812 PLUS - page 41

    4.2 Remote Operation 4.2.1 Remote Programming The 1812 can be programmed and operated from a remote location using a touch-tone telephone. B e sure that the ability for the 1812 to answer an incomin g call ha s not been disable d (see 2.2.9). Note: The 1812 m aster code cannot b e programmed re motely – it can only be programmed from the system k ...

  • DoorKing 1812 PLUS - page 42

    4.2.3 Relay Activation The 1812 system relays can be activated from th e house. Refer to the to ne open numbers t hat where programmed in section 2.2.8 to determin e each of the activation numbers. • Momentary Activ ation (Relay activates for its programmed strike time) • Hold Open (Relay will activate and remain activated). • Deactivate (Rel ...

  • DoorKing 1812 PLUS - page 43

    SECTION 5 – MAINTENANCE The DoorKing 1812 tel ephone entry sy stem is esse ntially a mai ntenance free device. When the unit is properly installed, it should provide years of trouble free servi c e. Maintenance is limited to updating the access codes and temp orary access codes o n an as needed basis. The faceplate of the unit should be cleaned o ...

  • DoorKing 1812 PLUS - page 44

    5.2 Phone Line Polarity C.O. (Phone Company ) C.O. (Phone Company ) Phone In Phone In Phone Out Phone Out Home Home 8 6 7 3 1 5 4 2 Bypass Switch DC Positive DC Positive DC Positive DC Positive DC Negative DC Negative DC Negative DC Negative 1812 Terminal 1 3 2 4 5 Phone In Phone In Phone Out Phone Out Ground DC Positive DC Positive DC Negative DC ...

  • DoorKing 1812 PLUS - page 45

    5.3 Isolating Noise Problems If noise or hum is present on the resident’s pho ne line after installation of the 1812 telephone intercom system, use the pro cedure on the next page to find and correct the source of the noise. This procedure will require the use of a telephone test set (DoorK ing p/n 1800-050 or equi valent). Typically, noise is us ...

  • DoorKing 1812 PLUS - page 46

    5.4 Troubleshooting Tables SYMPTOM POSSIBLE SOLUTION(S) Cannot get into programming mode. • Wrong master code entered. Start over. • Waiting too long between pushing bu ttons. Enter information quicker. • Keypad is not plugged into board correctl y. Cable points down. System emits a long tone and cancels programming. • Waiting too long betw ...

  • DoorKing 1812 PLUS - page 47

    SYMPTOM POSSIBLE SOLUTION(S) System generates tone when granting access to a visitor, but will not work on regular phone line. • Switch the wires on the PHON IN terminals. System will not answer when called from the resident’s phone. • Using the wrong attention number. Re-program attention number. System will not answer when called from a rem ...

  • DoorKing 1812 PLUS - page 48

    5.5 Wire Diagram 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Mic Vol Master Code 123456789 1 0 1 1 Speaker Vol Keypad 1 2 3 4 5 6 7 8 ON MODEM / TCP ENB SW 1 Red White Green Yell ow Red White White +- Gray Orange Purple White DOORKING, INC., INGLEWOOD, CA 90301 Date: Dwg. No. Rev . Title: 1/09 A M1812P-001 1812 Plus and 1812 Access Plus Internal W ...

  • DoorKing 1812 PLUS - page 49

    5.6 Accessories Secondary Keypad Allows remote activation of the system relays by use of the access codes. Does not provide a ny voice co m munication to the main unit or to the resident telephone. P/N 1812-082. Surge Suppressers High voltage (115 V) suppresser. P/N 1876-010. Phone line suppresser. P/N 1877-010. Low voltage (28 V) su p presser. P/N ...

  • DoorKing 1812 PLUS - page 50

    5.7 Tables Complete the information i n the tables on the following p ages to maintain a record of th e information that has been programmed into the 1812 entry system. MASTER CODE Tone Open Numbers Relay 1 Relay 2 Momentary Activation Hold Release Hold 1 Hour Call Forward Sc hed ule Begin Time Do Not Disturb Schedule End Time Days of Week Begin Ti ...

  • DoorKing 1812 PLUS - page 51

    Directory Codes / Dial-Out Phone Numbers Directory Code Name Phone Number 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 1812-161-E-1-10 Page 51 ...

  • DoorKing 1812 PLUS - page 52

    Access Code Log Sheet Name Access Code Time Zone Schedule Number Relay Momentary or Hold Page 52 1812-161-E-1-10 ...

  • DoorKing 1812 PLUS - page 53

    1812-161-E-1-10 Page 53 ...

Fabricant DoorKing Catégorie Intercom System

Les documents que nous recevons du fabricant de l'appareilDoorKing 1812 PLUS peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques DoorKing
- manuels d’utilisations 1812 PLUS
- fiches produit DoorKing
- dépliants
- ou étiquettes-énergie DoorKing 1812 PLUS
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation DoorKing 1812 PLUS.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation DoorKing 1812 PLUS, manuels d’entretien, brefs manuels ou manuels de l’utilisateur DoorKing 1812 PLUS. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit DoorKing 1812 PLUS.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil DoorKing 1812 PLUS, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser DoorKing 1812 PLUS par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs DoorKing 1812 PLUS.

Le manuel d’utilisation complet DoorKing, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel DoorKing 1812 PLUS - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières DoorKing 1812 PLUS, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lDoorKing 1812 PLUS qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil DoorKing 1812 PLUS - qui devraient nous aider dans les premières étapes lors de l'utilisation DoorKing 1812 PLUS
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de DoorKing 1812 PLUS
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service DoorKing 1812 PLUS dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de DoorKing 1812 PLUS?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec DoorKing 1812 PLUS, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec DoorKing 1812 PLUS il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)