  • APC 3000XLT - page 2

    ...

  • APC 3000XLT - page 3

    1 Contents 1. Intr oduction ...................................................................... 3 2. Safety ................................................................................ 6 3. Pr esentation ...................................................................... 7 4. Installation .................................................. ...

  • APC 3000XLT - page 4

    2 ...

  • APC 3000XLT - page 5

    3 1. Intr oduction 1.1 Thank you! Thank you fo r sel e c ting this uninte r rupti ble po w er sourc e (UPS). It is d esig ned for many y e ars of reliab le, maintenance-free se rvi c e. Important! Please read this man ual. It pr ovides safe ty , installat io n, and o pe rating instruct io ns that w ill help you ge t the fullest p erf o rmance and s ...

  • APC 3000XLT - page 6

    4 1.3 Theory of Operation This hig h-perf o rmance, line-inter active, uninte rru p t i ble p ower sourc e (UPS) p r ov ides clean, reli- able , A C p ower to compu te r systems and other elec t rical e quipment — pr o te c ting them fr om pow e r blackouts, brownouts, swe lls, sa gs, s urg es , and interfere nc e. It is d esigne d to pr ov ide p ...

  • APC 3000XLT - page 7

    5 1.4 Featur es Intelligent Battery Management The UPS p ro vides v i sual and audible indications of the batt ery’ s present stat us including capacit y , lo w batter y condit ion, and r e pl ace batt e r y c o ndition. The UPS e xe rcises the batte r y d uring its self-t est, and dete cts a w eak battery before it is put in to serv ice. The UPS ...

  • APC 3000XLT - page 8

    6 2. Safety CAUTION! ■ T o reduce the risk of el e c tr ic shock in c o nditi ons whe re l oa d equipment grounding cannot be ve r ified , disconne ct the UPS fr om the A C pow e r out let be for e installing a compute r interf ace or acc esso r y slot signal cable. R e con ne ct the powe r cor d only aft e r all signaling co nnec tions are made. ...

  • APC 3000XLT - page 9

    7 3. Pr esentation 3.1 Fr ont panel W ith the UPS pl ugge d in, press the o n/tes t butt o n t o tu r n on the UPS and pow er the lo ads . S ee Sec . 5.1. On/te st also a ct iv ates the UPS’ s self-test and u t ility line voltage displays. See sect i o ns 5.3 and 5.6. The over l o a d LED lig hts when the loads co nnecte d to the UPS ex ce e d th ...

  • APC 3000XLT - page 10

    8 3.2 Rear Panel T ower Models Rack Mount Models ...

  • APC 3000XLT - page 11

    9 Use the computer inter face port for UPS monitoring and contr ol. See section 7. The configuration button changes the UPS’s sensitivity to utility voltage variations and the low battery warning interval. See sections 5.9 and 5.10. The configuration LED indicates the voltage sensitivity setting and the low battery warning interval. See sections ...

  • APC 3000XLT - page 12

    10 4. Installation T o obtain warr anty cov er age fill out and ret urn the war rant y r egis tr ation car d no w . 4.1 Inspection Inspect the UPS up on r eceipt. Notify the carr ier and dealer if the re is damag e. T he pa ckag ing is re- cy clab le ; sa ve it for re use or dispose of it pr ope rly . 4.2 Placement T ower Models Install the UPS in ...

  • APC 3000XLT - page 13

    11 Installing the Support Brackets 1. V e rify the conte nts of the kit. It c o ntains: two adjustab le-length L-channel s u pports, eight c lip nuts, e i ght 10-32 x 1/2” flat-head scre w s, and eig ht washe rs. T he washers are f or use wit h square r a ck holes only . 2. If the r a c k uses thread e d holes, d rill out the app ro p ria t e fro ...

  • APC 3000XLT - page 14

    12 4.3 Pr otection Strategies This UPS pr ovides high performance p ower line pr o tection to the load s. Ther e are, ho w ev e r , othe r po t e ntial ent r y points fo r damaging surges in inf or ma tion sy st ems. These inclu d e ser ial por ts (RS- 232, RS-422, RS-485, etc.), pa rall el ports , te l eph o ne lines, and network c o nnections. Th ...

  • APC 3000XLT - page 15

    13 4.4 Install Accessor y (Optional) Some UPS acc essor ies c o nnect to the comput e r int e rface (DB-9) po r t, while other s install in the acc essor y slot. Se e the lit e rat ure a c co mpanying the accessory to d e te rmine pr oper installation. The scre w s holding the slot cov er are #2 Phillips hea d t yp e. T o use the c omputer int erfa ...

  • APC 3000XLT - page 16

    14 Co mpleted XL installation w ith tw o batte r y pac ks. 4.6 Connect to Utility Plug the UPS int o an L6-20 r e ce p tacle co nne ct e d t o a 208V AC, 20 Amp ser vice. T he s ervice may be either 50 or 60 Hz, b ut it must be equipped w ith a safe ty ground. If the ser vice at y our locat io n uses a re cep tacle othe r than an L6-20, the UPS plu ...

  • APC 3000XLT - page 17

    15 4.6 Char ge the Battery The UPS c harges its battery w hene v e r it is c o nnec te d to ut ility po wer . For best results, charge th e battery for 2.5 hours be for e use. It is acc e pt ab le to use the UPS without first charging the batter y , but on-batter y ru n time may be reduce d unt il the battery charges . 4.7 Connect the Loads Plug th ...

  • APC 3000XLT - page 18

    16 5. Operation 5.1 Switch On W ith the UPS plugg e d in, pr ess the on/test (up pe r) b ut ton to sup ply powe r to the loads. The loads are immediat ely p ow ere d while the UPS beeps and per fo rms a self-test. Se e se c tion 5.3. 5.2 Switch Off T o swi t c h o ff the UPS’ s output po wer , p ress the off (low er) bu t ton. It may be con ve ni ...

  • APC 3000XLT - page 19

    17 5.3 Self-test U se the self-test t o ve rify b oth the o perati on of the UPS and the co ndition of the batt ery . W ith the UPS plugged in to nor mal utility pow e r , act iv ate the self-t est by pr essing the on/t est but ton unti l the UPS be e ps and the o n-line LED flashes. N ote: By de fault the UPS p erforms a self-t est at po w er up a ...

  • APC 3000XLT - page 20

    18 5.5 Battery Char ge Bar Graph The 5-LED display o n the r i ght o f the front panel sho w s the p resent charge of the UPS’ s batte r y as a perce ntage o f the batt ery’ s capacit y . W hen al l five LEDs light, the batt ery is fully charged. When the lo west LED is flashing, the battery can su pply less than two minu t es o f run t ime fo ...

  • APC 3000XLT - page 21

    19 The S mar t B o ost LED c o mes on t o indicate that the UPS is co mpensat ing for a low voltage condi- tion. Sm artT r im and Sm artBo ost indicati ons ar e ad visor y . No user ac tion is require d . T o c heck the util- ity voltag e use the utilit y v oltage display . Se e sec tion 5.6. 5.8 Cold Start W he n the UPS is of f and there is no ut ...

  • APC 3000XLT - page 22

    20 un d e r such conditions, batter y capacit y and ser vi ce life may be con se r ve d b y reducing the sensitiv - ity of the UPS. T o re d uce UPS sensiti vity , p ress the c onfiguration b ut ton on the r ear panel. Use a po i nted ob j ec t su ch as a pe n t o press the b ut t on. P r ess it once t o se t the UPS’ s s ensitivi ty t o re d uce ...

  • APC 3000XLT - page 23

    21 6. Alarms 6.1 On Battery In on-batt er y o perat io n, the o n-batter y LED comes o n and the UPS sounds an audible alarm c o nsist in g of four beeps ever y 30 seco nds. Th e alar m st op s w hen the UPS retu r n s t o on-line opera tio n . Pr ess the on /t est but t o n during o n-battery alarm s t o sto p the b e eping . T his w orks fo r the ...

  • APC 3000XLT - page 24

    22 7. Options 7.1 Overview This UPS has seve r al op t i ons that su p po rt advanced op e rat io n . Advance d o p erati ons inclu d e gra ce ful sh utd own of a protected co mputer , and seve r al c o mmunicati o n and command func tions. Co mput er sys te ms r equ ir e time to per for m an order ly shutd o w n, without corru pting or losing data ...

  • APC 3000XLT - page 25

    23 8. T r oubleshooting Problem Possible Cause Solution UPS will not turn on. On/test button not pushed. Press the on/test button to power the UPS and the load UPS input circuit breaker tripped. Reduce the load on the UPS by unplugging equipment and reset the circuit breaker by pressing the plunger back in. Very low or no utility voltage. Check the ...

  • APC 3000XLT - page 26

    24 Problem Possible Cause Solution Low battery light is on and the on-line light is off. The UPS is shut down and the battery is discharged from an extended power outage. None. The UPS will return to normal operation when the power is restored and the battery has a sufficient charge. The replace battery light is lit. Weak batteries. Allow the batte ...

  • APC 3000XLT - page 27

    25 10. Replacing the Battery This UPS has a re p laceable batte r y . Please r ea d section 10.1 be for e perfor ming the p roce d u re i n sect io ns 10.3 o r 10.4. 10.1 W arning ■ This U ninte r ruptible P ower S ou r c e (UPS) c ontains pot entiall y hazardous voltag e s. Do not at- tempt to disassemble the unit b e yond the batte r y replacem ...

  • APC 3000XLT - page 28

    26 10.3 Battery Replacement Pr ocedur e (T ower models) N ote: Please r ead the cau tions in secti o n 10.1. Batte r y re p la cement is a safe p r oced ure, isolate d from e l ect rical hazards. Y ou may lea ve the UPS and lo ads on for the foll ow in g procedure. 1. Gr asp the top edge of the botto m front c ov e r and til t it out. 2. Unh o ok t ...

  • APC 3000XLT - page 29

    27 second set of batte ries in, then guid e the co nnec to r o v e r the batteries and conne c t it to th e fro nt co nnec tor of the battery compar tment. Note : S ma ll sparks at the batte r y co nnecto r s ar e normal d ur ing batte r y c o nne c tion. Close the batter y c o mpar t m ent door , making su re that no wi res are pinched . Replace t ...

  • APC 3000XLT - page 30

    28 5 . S lide the first se t o f new batteries into the unit. Hold the con ne ct o r d own be low the to p o f the batteries and t oward the do o r; otherw ise the assembly w ill not fit. Guid e the c onn ec tor ov e r the top o f the batteries and con ne ct it to the rear c o nne ctor of the batt ery co mpar tment. Se t the fo am spacer against th ...

  • APC 3000XLT - page 31

    29 12. Specifications 1400 VA 2200 VA 3000 VA Acceptable input voltage 0 - 325 VAC Input voltage (on-line operation)* 160-253 VAC 208 volt output range* 176-229 VAC 120 volt output range* with 400 VA load with no load 95-130 VAC 100-135 VAC Nominal input frequency 50 or 60 Hz, autosensing Input Protection Resettable circuit breaker Frequency limits ...

  • APC 3000XLT - page 32

    30 1400 VA 2200 VA 3000 VA Battery type Spill proof, maintenance free, sealed lead-acid Typical battery life 3 to 6 years, depending on number of discharge cycles and ambient temperature Typical recharge time 2 to 5 hours from total discharge Operating temperature 0 to +40 °C (+32 to +104 °F) Storage temperature -15 to +45 °C (+5 to +113 °F) Op ...

  • APC 3000XLT - page 33

    31 13. How to Deter mine On-batter y Run T ime This tab le will aid in est imating the le ngth o f run time that y ou may exp ect f o r a gi ve n load . 1. T o calculat e the on-battery run time first det e rmine the total load pr o t ect ed by the UPS in V olt-Amps. O btain lo a d figures fr om either the labe lling o n the p rot e ct e d e q uipm ...

  • APC 3000XLT - page 34

    32 3000 V A Models Typical On-Battery Run Time Versus Load, in Minutes Load Internal Battery 1 Battery Pack 100 VA 228 491 150 VA 183 394 200 VA 152 328 300 VA 110 245 400 VA 84 193 500 VA 67 157 600 VA 54 131 800 VA 36 96 1000 VA 26 73 1200 VA 20 58 1400 VA 16 46 1600 VA 13 37 2000 VA 10 26 2200 VA 8 22 2500 VA 7 18 3000 VA 5 13 ...

  • APC 3000XLT - page 35

    33 14. User Configuration Items Note: Setting these items requires optional software or hardware. Function Factory Default User Selectable Choices Description Automatic Self-Test Every 14 days (336 hours) Every 7 days (168 hours), On Startup Only, No Self-Test Sets the interval at which the UPS will execute a self-test. UPS ID UPS_IDEN Up to eight ...

  • APC 3000XLT - page 36

    34 Notes: ...

  • APC 3000XLT - page 37

    35 Notes: ...

  • APC 3000XLT - page 38

    36 Limited W ar ranty American Po w er Co nver sion (APC) war rants its pr o ducts to be fre e from d efec ts in mate rials and w o rkmanship fo r a period of two years fr o m the dat e o f purchase. Its o bligation under this war - r anty is limite d to repairing o r replacing, at its ow n sole opt io n, any s uch de fective produ c ts. T o obtain ...

  • APC 3000XLT - page 39

    ...

  • APC 3000XLT - page 40

    990-7031 Revision 1 10/96 ...

Fabricant APC Catégorie Power Supply

Les documents que nous recevons du fabricant de l'appareilAPC 3000XLT peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques APC
- manuels d’utilisations 3000XLT
- fiches produit APC
- dépliants
- ou étiquettes-énergie APC 3000XLT
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation APC 3000XLT.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation APC 3000XLT, manuels d’entretien, brefs manuels ou manuels de l’utilisateur APC 3000XLT. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit APC 3000XLT.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil APC 3000XLT, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser APC 3000XLT par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs APC 3000XLT.

Le manuel d’utilisation complet APC, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel APC 3000XLT - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières APC 3000XLT, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lAPC 3000XLT qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil APC 3000XLT - qui devraient nous aider dans les premières étapes lors de l'utilisation APC 3000XLT
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de APC 3000XLT
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service APC 3000XLT dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de APC 3000XLT?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec APC 3000XLT, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec APC 3000XLT il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)