Manuel d’utilisation Datalogic DLL2020-WO

30 pages 2.44 mb
Télécharger

Aller à la page of 30

Summary
  • Datalogic DLL2020-WO - page 1

    User's manual Datalogic DLL2020-WO ...

  • Datalogic DLL2020-WO - page 2

    Copyright © 1998, Datalogic. This manual is copyrighted, with all rights reserved. Under the copyright laws, this manual may not, in whole or in part, be copied, photocopied, reproduced, translated or converted to any electr onic medium or machine readable form without prior written consent of Datalogic. Limited Wa rranty Under all circumstances t ...

  • Datalogic DLL2020-WO - page 3

    T able of contents Preface i Chapter 1 The DLL2020-WO 1 1.1 Unpacking the DLL2020-WO 2 1.2 Scanning bar codes with the DLL2020-WO 4 1.3 Scanner labelling 7 1.4 Maintaining the scanner 11 1.5 Contr olling the scanner fr om the POS system 11 Chapter 2 Installing the DLL2020-WO 13 Installing the scanner 14 Appendices A. Connector types and pin definit ...

  • Datalogic DLL2020-WO - page 4

    Preface The Datalogic DLL2020-WO is a high performance omni-directional scanner , which provides optimal scanning conditions. The DLL2020-WO shar es the same quality of the GOLDRUSH TM polygon and Scantium decoder chip as Datalogic’ s popular Hunter H-3010, Pollux P-4010 and Castor C-5010 scanners. T ogether with its compact and er gonomic design ...

  • Datalogic DLL2020-WO - page 5

    Chapter 1 The DLL2020-WO ...

  • Datalogic DLL2020-WO - page 6

    1.1 Unpacking the DLL2020-WO T ake the scanner and its accessories out of the box and remove all packing materials. Refer to the packing list in or der to ensur e that you have r eceived all the items or der ed. Visually inspect the scanner and accessories for any visible traces of damage. Refer to the figur e in paragraph 1.3 to locate the interfa ...

  • Datalogic DLL2020-WO - page 7

    The various parts of the DLL2020-WO are: Sleep mode switch If a sleep mode time-out has been programmed, the scanner can be r eactivated by pr essing this switch. The sleep-mode featur e can be pr ogram- med by means of the menu labels in the Configuration Guide. NOTE: The default value for the sleep mode time-out is set to 30 minutes. When the sca ...

  • Datalogic DLL2020-WO - page 8

    1.2 Scanning bar codes with the DLL2020-WO The DLL2020-WO is an omnidir ectional scanner featuring a 4-dir ectional scan field with a 16-lines scan pattern. Bar codes can easily be r ead by pr esenting them to the scanner . The scan volume is illustrated in the figur e above. The optimal r eading zone lies between 3 and 15 cm fr om the scanner wind ...

  • Datalogic DLL2020-WO - page 9

    The Dll2020-wo scanner can be used handsfr ee as well as hand held , e.g.: a) Handsfr ee scanning by pr esenting the item to the scanner . b) Bar code labels can also be scanned in hand held mode, by taking the scanner by the handle and hold it in fr ont of the bar code label on the pr oduct. 1 2 2 1 The DLL2020-WO 5 ...

  • Datalogic DLL2020-WO - page 10

    c) Y ou can also hold the scanner without the handle. 1 2 6 The DLL2020-WO ...

  • Datalogic DLL2020-WO - page 11

    1.3 Scanner labelling Ther e ar e four labels on the scanner . The first thr ee labels can be found on the housing of the DLL2020-WO, as indicated in the figur es below . The fourth label is visible through the scanner window . All the labels have been attached by the manufactur er and should in no case be r emoved. The scanner’ s serial number c ...

  • Datalogic DLL2020-WO - page 12

    Laser safety English: The DLL2020-WO scanner complies with safety standar d IEC 825-1 (1993) for a Class 1 laser pr oduct. It also complies with U.S. 21CFR1040 as applicable to a Class IIa laser pr oduct. Avoid long term viewing of dir ect laser light. German: Der Strichcode-Scanner DLL2020-WO entspricht den Sicherheitsvorschriften nach IEC 825-1 ( ...

  • Datalogic DLL2020-WO - page 13

    Finnish: DLL2020-WO-skanneri täyttää luokan 1 lasertuotteelle IEC 825-1:ssä (1993) asetetut turvavaatimukset. Se täyttää myös U.S. 21CFR1040:ssa asetetut vaatimukset siltä osin kuin ne koskevat luokan IIa lasertuotetta. Vältä pitkäaikaista suoraan laservaloon katsomista. Swedish: Avsökar en DLL2020-WO uppfyller säkerhetsnormen IEC 825 ...

  • Datalogic DLL2020-WO - page 14

    Optical The use of optical instruments with this pr oduct will incr ease eye hazard. Optical instruments include binoculars, micr oscopes and magnifying glasses but do not include eye glasses worn by the user . Radiant Ener gy The DLL2020-WO uses a low-power laser diode operating at 650 nm in an opto-mechanical scanner r esulting in less than 0.7 m ...

  • Datalogic DLL2020-WO - page 15

    1.4 Maintaining the scanner The DLL2020-WO scanner requir es little maintenance. Only occasional cleaning of the scanner window is necessary in or der to r emove dirt and fingerprints. The scanner can be cleaned during operation. T o this end use a non-abrasive glass spray cleaner and a soft lint-free cloth only . 1.5 Contr olling the scanner fr om ...

  • Datalogic DLL2020-WO - page 16

    POS system Polaris P-7010 Scanner control 12 The DLL2020-WO DLL2020-WO ...

  • Datalogic DLL2020-WO - page 17

    Chapter 2 Installing the DLL2020-WO ...

  • Datalogic DLL2020-WO - page 18

    14 Installing the DLL2020-WO 2.1 Installing the scanner This chapter describes the instructions necessary for installing the DLL2020-WO scanner . Due to many POS systems on the market, a lar ge number of communication cables is available. Make sur e that you have the right cable to connect the scanner to your POS or computer . Follow these steps ca ...

  • Datalogic DLL2020-WO - page 19

    Installing the DLL2020-WO 15 2. Y ou have four options to connect the scanner to your POS or computer . A) RS232 direct power For those systems which supply electrical power on the serial port (minimal r equir ements: +5 V dc, 250 mA), the following set-up is applicable. Plug the cable with the 10-pin modular jack into the scanner port until a firm ...

  • Datalogic DLL2020-WO - page 20

    16 Installing the DLL2020-WO B) Keyboar d W edge direct power For those systems which supply electrical power on the keyboard port (minimal requir ements: +5 V dc, 250 mA), the following set-up is applicable. Plug the cable with the 10-pin modular jack into the scanner port until a firm ‘click’ is hear d. Connect the female connector at the oth ...

  • Datalogic DLL2020-WO - page 21

    Installing the DLL2020-WO 17 C) RS232 non direct power For those systems which do not supply electrical power on the serial port, the following set-up is applicable. Plug the cable with the 10-pin modular jack into the scanner port until a firm ‘click’ is hear d. Plug the other connector into the splitter box, as illustrated in the figur e belo ...

  • Datalogic DLL2020-WO - page 22

    18 Installing the DLL2020-WO D) Keyboard W edge non direct power For those systems which do not supply electrical power on the keyboar d port, the following set-up is applicable. Plug the cable with the 10-pin modular jack into the scanner port until a firm ‘click’ is hear d. Plug the other connector into the splitter box as illustrated in the ...

  • Datalogic DLL2020-WO - page 23

    Installing the DLL2020-WO 19 OPEN PROGRAMMING MODE 1. T o select the scanner inter face (RS232 factory default), scan the following codes: 1. Open the scanner Pr ogramming Mode by scanning code 1 2. - Return to RS232 default by scanning code 2 OR - Return to Keyboard W edge default by scanning code 3 IMPORT ANT 8 7 1 2 34 5 10 0 00 1 ...

  • Datalogic DLL2020-WO - page 24

    20 Installing the DLL2020-WO RETURN TO RS232 DEF AUL T 2. IMPORT ANT: Pr ogramming Mode is closed after scanning this code. RETURN TO KEYBOARD WEDGE DEF AUL T 3. IMPORT ANT: Pr ogramming Mode is closed after scanning this code. 7 1 2 34 5 10 0 10 0 7 1 2 34 5 10 0 13 1 ...

  • Datalogic DLL2020-WO - page 25

    Appendices A. Connector types and pin definitions B. T echnical Specifications C. T r oubleshooting ...

  • Datalogic DLL2020-WO - page 26

    22 Appendices A. Connector types and pin definitions The Dll2020-wo has a dual interface: RS232/Keyboard Wedge. The pin definition for the scanner port and the connector to be used for the por t ar e shown in the connection diagram below . Connection Diagram PC - CLOCK DESCRIPTION RJ - 48 PCB ( front view ) Scanner port 10 pin connector CTS RXD Pin ...

  • Datalogic DLL2020-WO - page 27

    Appendices 23 B. T echnical specifications Electrical Power supply voltage 100 - 250 V ac, 50/60 Hz DC input to scanner + 5 V dc ± 5%, 250 mA Dual interface RS232/Keyboard Wedge Optical Light source Visible laser diode (650nm) Depth of field 250 mm Scan pattern 4 directions scan field, 16 lines scan pattern Scan rate 800 scans / second Decoding Ba ...

  • Datalogic DLL2020-WO - page 28

    24 Appendices C. T r oubleshooting This section contains information on solving pr oblems you may encounter when using the scanner . If tr oubles occur , take a moment to r ead the information in this section. However , before r eferring to the diagnostic tips make sur e that the scanner is installed as described in Chapter 2 and that all cables ar ...

  • Datalogic DLL2020-WO - page 29

    Appendices 25 The scanner is on but a bar code cannot be read. The LED is red. Diagnostic Tips n The scanner window is dirty. Clean the n scanner window as described in the n Maintenance section. n The presented bar code type is not n enabled. Select the bar code type with n the Configuration Guide. n The scanner is disabled by the host. n Refer to ...

  • Datalogic DLL2020-WO - page 30

    26 Appendices The green LED stays on. A bar code is read by the scanner but not accepted by the host system. Diagnostic Tips The scanner is continuously seeing a bar code. Remove all bar code labels from the scan volume of the scanner and try again. The scanner cannot send the data to the host system. There is no proper handshaking between the scan ...

Fabricant Datalogic Catégorie Laptop

Les documents que nous recevons du fabricant de l'appareilDatalogic DLL2020-WO peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Datalogic
- manuels d’utilisations DLL2020-WO
- fiches produit Datalogic
- dépliants
- ou étiquettes-énergie Datalogic DLL2020-WO
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Datalogic DLL2020-WO.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Datalogic DLL2020-WO, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Datalogic DLL2020-WO. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Datalogic DLL2020-WO.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Datalogic DLL2020-WO, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Datalogic DLL2020-WO par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Datalogic DLL2020-WO.

Le manuel d’utilisation complet Datalogic, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Datalogic DLL2020-WO - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Datalogic DLL2020-WO, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lDatalogic DLL2020-WO qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Datalogic DLL2020-WO - qui devraient nous aider dans les premières étapes lors de l'utilisation Datalogic DLL2020-WO
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Datalogic DLL2020-WO
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Datalogic DLL2020-WO dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Datalogic DLL2020-WO?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Datalogic DLL2020-WO, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Datalogic DLL2020-WO il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image