Manuel d’utilisation Sherwood EF-3 BAYI

28 pages 1.13 mb
Télécharger

Aller à la page of 28

Summary
  • Sherwood EF-3 BAYI - page 1

    1 ENVIROFIRE PELLET STOVE EF-3 BAYi OWNERS TECHNICAL MANUAL SHERWOOD INDUSTRIES LTD. 6782 OLDFIELD ROAD VICTORIA, BRITISH COLUMBIA V8M-2A3 MODELS FS, FPI and BIH ...

  • Sherwood EF-3 BAYI - page 2

    ENVIROFIRE INSTALLATION MANUAL TABLE OF CONTENTS INTRODUCTION Important Sa fety Data ........................................................... 3 Pellet Q uality ........................................................................ 4 Warnings and Re commendatio ns......................................... 5 Automatic Safe ty Feat ures .......... ...

  • Sherwood EF-3 BAYI - page 3

    IMPORTANT SAFETY DATA Please read this entire manual befo re installation and use of this pellet fuel bu rning room heater. Failure to follo w these instructions could result in prop erty damage, bodily injury or even death. CAUTION: DO NOT CONNECT OT ANY AIR DISTRIBUTION DUCT OR SYSTEM; DO NOT BURN GARBAGE OR FLAMA BLE FLUIDS SUCH AS GASOLINE, NAP ...

  • Sherwood EF-3 BAYI - page 4

    PELLET QUALITY IS IMPORTANT, PLEASE READ THE FOLLOWING PAGE Your pellet stove has been designed to burn wood pellets only. Since there are many manufacturers of wood pellets it is important to select pellets that are free of dirt or any impurities. The Pellet Fuel Industries (P.F.I.) has established standards for wood pellet manufactures. We recomm ...

  • Sherwood EF-3 BAYI - page 5

    WARNINGS AND RECOMMENDATIONS A. Do not abuse the glass by striking or slamming the door shut. B. Do not attempt to operate the stove with broken glass. C. Do not attempt to open the door and clean the glass while the unit is in operation. If you must clean the glass, use a soft cotton cloth and mild window cleaner. D. Do not use abrasive cleaners t ...

  • Sherwood EF-3 BAYI - page 6

    HOW TO START AND OPERATE YOUR PELLET APPLIANCE 1. Check and fill hopper with pellets. 2. Switch on power by pushing the start up switch once only. CONVECTION BLOWER SPEED CONTROL 3. Turn the Dial A Fire knob to the 12 o’clock position. (Lower grade pellets may need a higher setting on the feed rate). NOTE: unit will take longer to light if the ho ...

  • Sherwood EF-3 BAYI - page 7

    SLIDER/DAMPER INSTALLATION /OPERATION INSTRUCTIONS This is used to regulate the airflow through the pellet stove. INSTALLATION 1. Remove the slider rod (short rod with knob and nuts) and the two nuts from their package and open the left side panel. 2. Remove the knob and outer nut from the knob. Push the rod through the hole in the slider. Place th ...

  • Sherwood EF-3 BAYI - page 8

    AREAS FOR ROUTINE INSPECTION The following should be inspected perio dically to ensure that the a ppliance is operating at it s optimum and giving you excellent heat value: 2-3 DAYS/WEEKLY SEASONALLY or 2 TONS OF FUEL Burn Pot and Liner Exhaust Vent and Fresh Air Intake Tube Ash Pan Blower Mechanisms Inside Firebox Heat exchanger tubes Behind Fireb ...

  • Sherwood EF-3 BAYI - page 9

    DOOR GLASS (It is recommended that your dealer replace the glass if broken.) The door glass is made of 5 mm thick, high tempe rature PYROCERAMIC The center panel is 229 mm x 33 0 mm. To replace the glass, unscrew and remove the four glas s retain ers. Remove the glass and any broken pieces. High temperature fiberglass tape shoul d be used arou nd t ...

  • Sherwood EF-3 BAYI - page 10

    ELECTRICAL COMPONENT FUNCTIONS The following is a list of electrical components and their functi ons on the ENVIROFIRE EF-IIIi Bay pellet stove. 1. CONVECTION FAN CONTROL LER This controller is responsib le for varying the speed of the convection blower. The stove does have a fan control over-ride. Should the convection blower be set on low and dia ...

  • Sherwood EF-3 BAYI - page 11

    11. 160 ° F (71 ° C) TEMPERATURE SENSOR When this sensor (located on the left side firewall) reache s 160 ° F (71 ° C), the convection blow er will go to high, cooling the unit. 12. 140 ° F (60 ° C) N/O TEMPERATURE SENSOR (SHUT-DOWN SENSOR) This sensor (mounted on the exhaust bl ower housing) has t wo functions: - Should the fire go out, this ...

  • Sherwood EF-3 BAYI - page 12

    DECIDING WHERE TO LOCATE YOUR PELLET APPLIANCE 1. Check clearance s to combustibles. 2. Do not obtain combustion air from an attic, gara ge or any unventilated space. Combustion air may be obtained from a ventilated crawlspace. 3. Do not install the stove in a bedroom. 4. You can vent the stove through an exterior wall behind the unit or connect it ...

  • Sherwood EF-3 BAYI - page 13

    REMOVING YOUR NEW STOVE FROM IT’S PALLET To remove your new stove from its pallet , open the left and right side panels. There are two wood screws that are holding the bottom of the stove to the pallet. Remove the screws. Close the sid e panels. See PAGE 18 how to install the pedestal. INSERT MODEL FREE STAND MODEL REMOVE SCREW HERE FIREPLACE DIM ...

  • Sherwood EF-3 BAYI - page 14

    MASONRY FIREPLACE INSERT INSTALLATION, MODEL FPI The Fireplace Insert model includes surround f ace plates and a pedestal. When installing this unit, ensure that the pedestal is removed from its box and installed on the bottom of the unit. (Surround assembly instructions are in this manual). CLEARANCE TO COMBUSTIBLES: Side wall .................... ...

  • Sherwood EF-3 BAYI - page 15

    ASSEMBLING THE FACE PLATE FOR THE FPI AND BIH MODELS 1. To attach the pedestal, place the unit on its back, making sure not to damage the wiring, then bolt the pedestal onto the unit. Back off the screws on the base, install the pedestal over the screws. Lock in place using t he keyholes, tighten the screws. 2. Assemble the three faceplates to the ...

  • Sherwood EF-3 BAYI - page 16

    RECOMMENDED FRAMING FOR BUILT IN HEATER When installing model BIH it is recommended that you use the dimensions shown in the diagram below. These type of clearances will make it easy and readily accessible for service. BUILT IN HEATER CLEARANCES TO COMBUSTIBLES This unit includes a 3” (75 mm) pedestal and surrounding faceplates. The part of the u ...

  • Sherwood EF-3 BAYI - page 17

    FREESTANDING INSTALLATION, MODELS FS CLEARANCES TO COMBUSTIBLES (FREESTANDING) - Side wall to unit A- 6 INCHES (150 mm) - Back wall to unit B- 1 INCH (25 mm) - Corner to unit C- 1 INCH (25 mm) - Mantle (Hearth Mount) 8 INCHES ( - Combustible flooring underneath the unit and extending 6 INCHES (150 mm) to the sides and front must be protected by a n ...

  • Sherwood EF-3 BAYI - page 18

    MODEL FS (FREESTANDING) INSTALLATION PEDESTAL INSTALLATION : Model FS comes with a p edestal that has to be attached prior to installation: - Remove the pedestal from the box - Remove the ENVIROFIRE heater form the box. - Place the unit on its back, making sure not to damage the wiring. - Back off the screws on the base, install the pedestal over t ...

  • Sherwood EF-3 BAYI - page 19

    HORIZONTAL EXHAUST THROUGH THE WALL 1. NOTE: Use only listed type “PL” or “L” pellet venting prod ucts . Failure to use listed components may cause damage or personal injury or death. 2. Choose a location for your stove that meets the requirements stated in this manual and allows installation with the least amount of interference to house f ...

  • Sherwood EF-3 BAYI - page 20

    THROUGH WALL INSTALLATION 1” 20 ...

  • Sherwood EF-3 BAYI - page 21

    FREESTANDING INSIDE VERTICAL INSTALLATION 1. Choose a stove location that is ideal. See the section Deciding Where to Locate Your Pellet Appliance. 2. Place a non-combustible hearth pad where necessary. 3. Place the unit on the hearth pad and space it in a manner so when the pellet vent is installed vertically, it will be 3” (76 mm) away from a c ...

  • Sherwood EF-3 BAYI - page 22

    FREESTANDING OUTSIDE VERTICAL INSTALLATION To accomplish the above titled installation, follow steps 1 through 8 in the previous section and then finish it by performing the following. 9. Install a tee with clean out on the outside of the house. 10. Install PL vent upward from the tee. Make sure that you install support brackets t o keep the vent s ...

  • Sherwood EF-3 BAYI - page 23

    MOBILE HOME INSTALLATION - Secure the heater to the floor using the two bolt holes supplied in the pedestal. - CAUTION: THE STUCTURAL INT EGRITY OF THE MANUFACTURED HOME FLOOR, WALL, AND CEILING/ROOF MUST BE MAINTAINED. - Ensure the unit is electrically grounded to the chassis of your home (permanently). - Do not install in a room people sleep in. ...

  • Sherwood EF-3 BAYI - page 24

    TROUBLESHOOTING DO NOT: - Hold the start-up switch down, this is a momentary contact switch and can be damaged if held down too long. - Service the stove with wet hands. The stove is an electrical appliance, which may pose a shock hazard if handled improperly. Only qualified technicians should deal with possible internal electrical failures. - Remo ...

  • Sherwood EF-3 BAYI - page 25

    4. The convection blower will not function normally - Check all the connections between the contro ller, switch, and the convection blower against the wiring diagram. - If the convection motor will not run, apply 230V AC to the motor directly. If the m otor runs, replace the fan controller. If the motor does not run, the convection blower has faile ...

  • Sherwood EF-3 BAYI - page 26

    placing a jumper across the pins. If the auger now cycles very quickly, test the dial-a-fire potentiometer. If the auger did not cycle then replace the timing control module. - To test the dial-a-fire potentiometer. The potentiometer should have a range of 68K to approximately 850 K ( ± 10%), if the range is not close then replace the potentiomete ...

  • Sherwood EF-3 BAYI - page 27

    WIRING DIAGRAM 27 ...

  • Sherwood EF-3 BAYI - page 28

    WARRANTY Sherwood Industries Ltd. gives a five y ear limited warr anty on all steel manufa ctured parts. A one year warra nty is provided on all ele ctrical components. The above limited warranties are extended only to the original purchas er. There is no warranty on the following parts: - Glass window - Fiberglass rope baskets - Refractory materia ...

Fabricant Sherwood Catégorie Stove

Les documents que nous recevons du fabricant de l'appareilSherwood EF-3 BAYI peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Sherwood
- manuels d’utilisations EF-3 BAYI
- fiches produit Sherwood
- dépliants
- ou étiquettes-énergie Sherwood EF-3 BAYI
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Sherwood EF-3 BAYI.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Sherwood EF-3 BAYI, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Sherwood EF-3 BAYI. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Sherwood EF-3 BAYI.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Sherwood EF-3 BAYI, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Sherwood EF-3 BAYI par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Sherwood EF-3 BAYI.

Le manuel d’utilisation complet Sherwood, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Sherwood EF-3 BAYI - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Sherwood EF-3 BAYI, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lSherwood EF-3 BAYI qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Sherwood EF-3 BAYI - qui devraient nous aider dans les premières étapes lors de l'utilisation Sherwood EF-3 BAYI
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Sherwood EF-3 BAYI
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Sherwood EF-3 BAYI dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Sherwood EF-3 BAYI?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Sherwood EF-3 BAYI, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Sherwood EF-3 BAYI il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)