Manuel d’utilisation METRObility Optical Systems RADIANCE 10/100PS ACCESS OPTICAL NETWORK UNIT

24 pages 0.14 mb
Télécharger

Aller à la page of 24

Summary
  • METRObility Optical Systems RADIANCE 10/100PS ACCESS OPTICAL NETWORK UNIT - page 1

    Installation & User Guide Models: RA21-13 / RA21-14 / RA21-15 / RA21-16 / RA21-17 / RA21-1J / RA21-1X / RA21-1Y R ADIANCE 10/100M BPS A CCESS O PTICAL N ETWORK U NIT TM ACT LK ACT 100 BASE FX LK DIS Radiance RA21 LBK DIS II x PWR MAN FD 100 TM ACT LK ACT 100 BASE FX LK DIS Radiance RA21 LBK DIS II x PWR MAN FD 100 TM ACT ACT Radiance RA21 LBK L ...

  • METRObility Optical Systems RADIANCE 10/100PS ACCESS OPTICAL NETWORK UNIT - page 2

    This publication is protected by the copyright laws of the United States and other countries, with all rights reserved. No part of this publication may be reproduced, stored in a retrieval system, translated, transcribed, or transmitted, in any form, or by any means manual, electric, electronic, electromagnetic, mechanical, chemical, optical or oth ...

  • METRObility Optical Systems RADIANCE 10/100PS ACCESS OPTICAL NETWORK UNIT - page 3

    T able of Contents Radiance 10/100Mbps Access Optical Network Unit Installation & User Guide Overview .............................................................................................................. 4 Installation Guide ............................................................................................... 6 STEP 1: Unpack ...

  • METRObility Optical Systems RADIANCE 10/100PS ACCESS OPTICAL NETWORK UNIT - page 4

    4 Overview Overview The Metrobility Radiance 10/100Mbps Access Optical Network Unit (ONU) offers the benefits of remote management while eliminating the expenses associated an additional chassis and management card at the remote site. The compact Access ONU is a complete standalone device designed for installation at the customer premise, with no a ...

  • METRObility Optical Systems RADIANCE 10/100PS ACCESS OPTICAL NETWORK UNIT - page 5

    Radiance 10/100Mbps Access Optical Network Unit 5 the sender . FEF enables the Access Line Card in the central of fice to detect a break in the Access ONU’ s fiber port receiver . The combination of these operations, along with the unit’ s remote management feature, enable easy deployment of Ethernet services to customers. The Radiance Access O ...

  • METRObility Optical Systems RADIANCE 10/100PS ACCESS OPTICAL NETWORK UNIT - page 6

    6 Installation Guide Installation Guide 2 A device that is wired straight through needs one crossover connection: If the cable is straight through crossover the MDI-II to MDI-X switch setting should be X II A device that is wired crossover needs a parallel connection: If the cable is straight through crossover the MDI-II to MDI-X switch setting sho ...

  • METRObility Optical Systems RADIANCE 10/100PS ACCESS OPTICAL NETWORK UNIT - page 7

    Radiance 10/100Mbps Access Optical Network Unit 7 * DIP switches can also be managed remotely via console commands or through Metrobility’s NetBeacon or W ebBeacon management software. Refer to the Command Line Interface Reference Guide , NetBeacon Element Management Software Installation & User Guide or W ebBeacon Management Software Install ...

  • METRObility Optical Systems RADIANCE 10/100PS ACCESS OPTICAL NETWORK UNIT - page 8

    8 Installation Guide Duplex The DUPLEX switch sets the duplex mode on the copper port when auto-negotiation is disabled. The copper port operates at full duplex when DUPLEX is ON. It operates at half duplex when DUPLEX is OFF . When auto-negotiation is enabled, the DUPLEX switch setting is ignored. Auto-Negotiation Auto-negotiation is supported onl ...

  • METRObility Optical Systems RADIANCE 10/100PS ACCESS OPTICAL NETWORK UNIT - page 9

    Radiance 10/100Mbps Access Optical Network Unit 9 3 Link Loss Carry Forward Link Loss Carry Forward (LLCF) is provided as an aid in troubleshoot- ing a remote connection. When LLCF is enabled, loss of the receive signal at the copper port prevents the fiber port from transmitting an idle signal onto the cable. Conversely , if the fiber port does no ...

  • METRObility Optical Systems RADIANCE 10/100PS ACCESS OPTICAL NETWORK UNIT - page 10

    10 Installation Guide TM ACT LK ACT TX RX LK DIS Radiance RA21 LBK DIS II x PWR MAN FD 100 T wisted-Pair Interface The copper port provides a shielded RJ-45 connector that supports a maximum segment length of 100 meters. Use only Category 5 cables. Fiber Optic Interface The unit’ s fiber receiver (RX) is to the right of the transmitter (TX). When ...

  • METRObility Optical Systems RADIANCE 10/100PS ACCESS OPTICAL NETWORK UNIT - page 11

    Radiance 10/100Mbps Access Optical Network Unit 11 4 mentary pairs. That is, a -1X model must always be connected to a -1Y . The -1X units are designed to transmit data at a wavelength of 1550nm and receive at 1310nm. Correspondingly , the -1Y units transmit data at 1310nm and receive at 1550nm. Apply Power Power is provided through the desktop pow ...

  • METRObility Optical Systems RADIANCE 10/100PS ACCESS OPTICAL NETWORK UNIT - page 12

    12 Installation Guide three-conductor cord, a maximum of 15 feet in length and a parallel blade, grounding-type attachment plug rated 15A, 125V . • AC 230V (USA): use a UL-listed cord set consisting of a minimum No. 18 A WG, type SVT three-conductor cord, a maximum of 15 feet in length and a T andem blade grounding- type attachment plug rated 15A ...

  • METRObility Optical Systems RADIANCE 10/100PS ACCESS OPTICAL NETWORK UNIT - page 13

    Radiance 10/100Mbps Access Optical Network Unit 13 User Guide This section contains information about the operating featur es of the Radiance 10/100Mbps Access Optical Network Unit. LED Indicators The Radiance Access Optical Network Unit provides several LEDs on the front panel for the visible verification of unit status and proper functionality . ...

  • METRObility Optical Systems RADIANCE 10/100PS ACCESS OPTICAL NETWORK UNIT - page 14

    14 User Guide Far End Fault ................................................................................... Enabled (ON) Link Loss Return .......................................................................... Disabled (OFF) Link Loss Carry Forward ............................................................. Disabled (OFF) Default Software ...

  • METRObility Optical Systems RADIANCE 10/100PS ACCESS OPTICAL NETWORK UNIT - page 15

    Radiance 10/100Mbps Access Optical Network Unit 15 Disabling a port stops the data flow to and from that port. Although data is neither sent nor received, the disabled port continues to accept, process and transmit management packets. However , if LLCF is enabled and the opposite port has no link, management packets will not be transmitted. Remote ...

  • METRObility Optical Systems RADIANCE 10/100PS ACCESS OPTICAL NETWORK UNIT - page 16

    16 User Guide Singlemode Fiber Optic Power Monitors Through software * , you can read the input and output power levels of the singlemode fiber optic port on the Access ONU. Input Power Level The accuracy of the input power monitor is ± 1dBm from -28dBm to -12dBm. The accuracy is ± 2dBm from -31dBm to -29dBm. The monitor is unresponsive below -31 ...

  • METRObility Optical Systems RADIANCE 10/100PS ACCESS OPTICAL NETWORK UNIT - page 17

    Radiance 10/100Mbps Access Optical Network Unit 17 Link Loss Carry Forward (LLCF) * The Access Optical Network Unit incorporates Link Loss Carry Forward as an aid in troubleshooting a remote connection. When LLCF is enabled, the ports do not transmit a link signal until they receive a link signal from the opposite port. W arning: If LLCF is enabled ...

  • METRObility Optical Systems RADIANCE 10/100PS ACCESS OPTICAL NETWORK UNIT - page 18

    18 User Guide Link Loss Return (LLR) The fiber optic port of the Access ONU has been designed with Link Loss Return functionality * for troubleshooting a remote connection. When LLR is enabled, the fiber port’ s transmitter shuts down if its receiver fails to detect a valid receive link. LLR should only be enabled on one end of the link and is ty ...

  • METRObility Optical Systems RADIANCE 10/100PS ACCESS OPTICAL NETWORK UNIT - page 19

    Radiance 10/100Mbps Access Optical Network Unit 19 T opology Solutions Radiance R5000 Radiance Acces Optical Network Unit Customer Premises CO/POP SNMP Control Remote Communications Path Status Reporting Configuration Instructions Used Bandwidth = 0 ...

  • METRObility Optical Systems RADIANCE 10/100PS ACCESS OPTICAL NETWORK UNIT - page 20

    20 User Guide T echnical Specifications Data Rate Data Rate ________ 100Mbps half duplex, 200Mbps full duplex (Fast Ethernet) ______________ 10Mbps half duplex, 20Mbps full duplex (Ethernet) Network Connections T wisted-Pair Interface Connector __________________________________ Shielded RJ-45, 8-pin jack Impedance _________________________________ ...

  • METRObility Optical Systems RADIANCE 10/100PS ACCESS OPTICAL NETWORK UNIT - page 21

    Radiance 10/100Mbps Access Optical Network Unit 21 Singlemode F/O Interface — extended long haul distance support (RA21-1J) Connector _____________________________________________________ SC W avelength _______________________________________________ 1550 nm RX Input Sensitivity ________________________________ -34 dBm minimum Output Power ______ ...

  • METRObility Optical Systems RADIANCE 10/100PS ACCESS OPTICAL NETWORK UNIT - page 22

    22 User Guide Product Safety , EMC and Compliance Statements T his equipment complies with the following requirements: •U L• DOC Class B (emissions) • CSA • EN55022 Class B (emissions) •C E• EN55024: 1998 (immunity) • EN60950 (safety) • IEC 825-1 Classification • FCC Part 15, Class B • Class 1 Laser Product This product shall be ...

  • METRObility Optical Systems RADIANCE 10/100PS ACCESS OPTICAL NETWORK UNIT - page 23

    Radiance 10/100Mbps Access Optical Network Unit 23 W arranty and Servicing Three-Y ear W arranty for the Radiance Access Optical Network Unit Metrobility Optical Systems, Inc. warrants that every Radiance Access Optical Unit will be free from defects in material and workmanship for a period of THREE YEARS from the date of Metrobility shipment. This ...

  • METRObility Optical Systems RADIANCE 10/100PS ACCESS OPTICAL NETWORK UNIT - page 24

    Product Manuals The most recent version of this manual is available online at http://www .metrobility .com/support/manuals.htm To obtain additional copies of this manual, contact your reseller , or call 1.877.526.2278 or 1.603.880.1833 Product Registration To register your product, go to http://www .metrobility .com/support/registration.asp 25 Manc ...

Fabricant METRObility Optical Systems Catégorie Switch

Les documents que nous recevons du fabricant de l'appareilMETRObility Optical Systems RADIANCE 10/100PS ACCESS OPTICAL NETWORK UNIT peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques METRObility Optical Systems
- manuels d’utilisations RADIANCE 10/100PS ACCESS OPTICAL NETWORK UNIT
- fiches produit METRObility Optical Systems
- dépliants
- ou étiquettes-énergie METRObility Optical Systems RADIANCE 10/100PS ACCESS OPTICAL NETWORK UNIT
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation METRObility Optical Systems RADIANCE 10/100PS ACCESS OPTICAL NETWORK UNIT.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation METRObility Optical Systems RADIANCE 10/100PS ACCESS OPTICAL NETWORK UNIT, manuels d’entretien, brefs manuels ou manuels de l’utilisateur METRObility Optical Systems RADIANCE 10/100PS ACCESS OPTICAL NETWORK UNIT. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit METRObility Optical Systems RADIANCE 10/100PS ACCESS OPTICAL NETWORK UNIT.

Manuel d’utilisation complet de l’appareil METRObility Optical Systems RADIANCE 10/100PS ACCESS OPTICAL NETWORK UNIT, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser METRObility Optical Systems RADIANCE 10/100PS ACCESS OPTICAL NETWORK UNIT par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs METRObility Optical Systems RADIANCE 10/100PS ACCESS OPTICAL NETWORK UNIT.

Le manuel d’utilisation complet METRObility Optical Systems, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel METRObility Optical Systems RADIANCE 10/100PS ACCESS OPTICAL NETWORK UNIT - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières METRObility Optical Systems RADIANCE 10/100PS ACCESS OPTICAL NETWORK UNIT, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lMETRObility Optical Systems RADIANCE 10/100PS ACCESS OPTICAL NETWORK UNIT qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil METRObility Optical Systems RADIANCE 10/100PS ACCESS OPTICAL NETWORK UNIT - qui devraient nous aider dans les premières étapes lors de l'utilisation METRObility Optical Systems RADIANCE 10/100PS ACCESS OPTICAL NETWORK UNIT
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de METRObility Optical Systems RADIANCE 10/100PS ACCESS OPTICAL NETWORK UNIT
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service METRObility Optical Systems RADIANCE 10/100PS ACCESS OPTICAL NETWORK UNIT dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de METRObility Optical Systems RADIANCE 10/100PS ACCESS OPTICAL NETWORK UNIT?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec METRObility Optical Systems RADIANCE 10/100PS ACCESS OPTICAL NETWORK UNIT, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec METRObility Optical Systems RADIANCE 10/100PS ACCESS OPTICAL NETWORK UNIT il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)