    Operation Manual LRM 2200SI LASER RANGE FINDER MONOCULAR 105 Sparks Ave., Toronto, ON M2H 2S5, Canada ...

  • Newcon Optik LRM 220SI - page 2

    ii ...

  • Newcon Optik LRM 220SI - page 3

    iii IMPORTANT INFORMATION Read prior to activa tion You have ju st purc hased a sophisti cated electro- optical de vice that emits i nvisible l aser radiat ion. To operate it properly, please, read this manual carefully.  NEVER direct laser beam at the eyes of pe ople or animals  NEVER aim the unit at the Sun or bright sources of light  NE ...

  • Newcon Optik LRM 220SI - page 4

    iv  Caution - use of optical instrum ents such as binoculars, loupes, mirrors, lenses , etc. wi th this product increases eye hazard  Avoid eye exposure to direct la ser beam or its close reflection  Prevent bri ght light f rom focu sing thro ugh the ey epiece ...

  • Newcon Optik LRM 220SI - page 5

    TABLE OF CONTENTS 1.  BRIEF DESCRIPTIO N ............................................. 2  Principle of operation .......................................................... 2  Key Featur es ........................................................................ 3  2.  DEVICE APP EARANCE .......................................... 4 ? ...

  • Newcon Optik LRM 220SI - page 6

    2 10.  CUSTOMER SUP PORT ......................................... 24  11.  QUAL ITY CERTIFICATE ..................................... 25  CAREFULLY READ ALL THE INSTRUCTIONS BEFORE USING THE UNIT ! FAILURE TO OBEY THE INSTRUCTIONS WILL VOID THE WARRANTY AND MA Y CAUSE INJURY! 1. BRIEF DESCRIPTION LRM 2200SI Laser Rang efinder Monocular ...

  • Newcon Optik LRM 220SI - page 7

    3 measurement allows height ca l culation. The unit m easures azimuth simultaneously as we ll. Speed o f an object m oving closer or further from the unit can also be calculated using the time-of-flight pri nciple. Key Features  Three channel optical s olution (optical, laser and receiver) ensures measurem ent accuracy  Original digital circu ...

  • Newcon Optik LRM 220SI - page 8

    4 2 3 4 5 6 7 1 8 2. DEVICE APPEARANCE Fig. 1. Front view 1 - Eyepiece 2 - Objective lens 3 - Laser em itter lens 4 - Receiver lens 5 - M (Mo de) butto n 6 - A (Acti on) but ton 7 - Body of the de vice 8 - Rubber grip ...

  • Newcon Optik LRM 220SI - page 9

    5 Fig.2. Rear view 1 - Eyepiece 10 - Tripod socket 9 - Battery compartment cover 12 - Classification 11 - Identification imprint imprint, shown below 9 11 1 12 10 ...

  • Newcon Optik LRM 220SI - page 10

    6 3. DELIVERY SET Standard delivery set LRM 2200SI is supplied in a set comprised of the following: Qty LRM 2200SI 1 9V Lithium (non-magnetic) battery 1 Soft carrying c ase Cleaning cloth 1 1 Neck strap 1 Operation m anual 1 Warranty card 1 ...

  • Newcon Optik LRM 220SI - page 11

    7 4. SPECIFICATION S Optics Magnificatio n Objective lens diameter Exit pupil diameter Field of view Type of coating 7x 25 mm 3.6 mm 8  Fully multi-coated optics Range Finder Laser Measuring range Accuracy First, last and auto target selectio n Meters/Yards display Last 10 readings recall Reticle Target quality indicator Class 1, eye safe, 905 n ...

  • Newcon Optik LRM 220SI - page 12

    8 Inclinometer Measuring elevation range ±80 o Accuracy ±1 o Speed Detector Measured spee d range 5-400 km /h Accuracy ±2 km/h Power Battery 9V Lithium (non-magnetic) Battery capacity Min 5,000 measurements (Scanning regime ) 'Low Batte ry' indicato r Yes Environmental Operational temperature range Storage temperature range -25 / +50 o ...

  • Newcon Optik LRM 220SI - page 13

    9 5. OPERATION INSTRUCTIONS 1 – Low battery indi cator 2 – Reticle (either -¦- or  ) 3 – Units of measurem ent 4 – Measurement resul t 5 – Target q uality i ndicator 6 – Lase r active indicat or 7 – Setup m ode indicat or 8 – Ready mode indicat or 4 6 2 1 5 3 8 7 Fig. 3. Liquid Crystal Display as seen through the eyepiece ...

  • Newcon Optik LRM 220SI - page 14

    10 Changing b attery To install a battery:  Slide the battery compartm ent cover down (Fig. 2)  Install the battery, observing correct polarity  Do not force the battery while placing back inside the compartment.  Close the compartm ent cover If the battery does not fit the compartment easily, it means that either polarity was reverse d ...

  • Newcon Optik LRM 220SI - page 15

    11 Measuring procedure When the unit is powered off the LCD will appear blank . To activate the unit p ress and hold A bu tton (Fig. 1) for half a second. The word ‘READY’ will appear on the display to indicate the unit is powered on. Pressing the A button (Fi g. 1) in Ready t o Measure m ode will initiate measurement. The result of th e measur ...

  • Newcon Optik LRM 220SI - page 16

    12 surface is more reflective tha n a ro ugh one. L arger targets reflect better than small ones. Ranging a target perpend icular to the laser beam provides better results th an the one positioned under a sharp angle to the beam . Weather con ditions that influen ce air tra nsparency (rain, fog, snow, mist) reduce maximum range. Bright sunny days w ...

  • Newcon Optik LRM 220SI - page 17

    13 Note: Even with target selection logic the unit may not always be able to range the desired target as its reflectivity may be too low to produce enough laser beam refl ections for statistically reliable calculation. A warning will be displayed if th e result is not statistically reliable. See more about target reflectivity in Additional displa y ...

  • Newcon Optik LRM 220SI - page 18

    14 o Distance from meters to yards o Speed from km/h to m ph 2  rEc – allows data recall of the last 10 m easurement results: o CLr – Clears all measurem ents  SEt – allows the user to select the following advanced options: o FrSt – First Target Measurement o LASt – Last Target Measure ment o AUtO – Auto Target Measurement 3 o Ret ...

  • Newcon Optik LRM 220SI - page 19

    15 calibration simi lar to one conducte d during pro duction pro cess. To perform the accuracy correction, select corr from the CAL menu. Perform correc tion accor ding to re quired measurement parameters by pressing Ac tion butt on, see tabl e below: Active mode of measurement ( Std ) Correction parameter Condition D, dE Distance Install unit at 1 ...

  • Newcon Optik LRM 220SI - page 20

    16 Magnetic Nort h (not True Nort h). If the unit detect s large installation errors (u nit is not well levelled or not aimed to the North), then LCD will show resu lt “444” and “99”, which means that correction was not pe rformed d ue to incorrect set up. Compas s calibrat ion If the System was ex posed to a strong m agnetic field or was n ...

  • Newcon Optik LRM 220SI - page 21

    17 Minimal gating distance of 000 m will be initially set, further pressing M button will increase gating distance by 100 m up to 2,100 m. When the de sired distance is reached – select it by pressing Action button. OVER 100M – indicates that gating is active To deactivate gating choose gating v alue zero or switch to the default m ode. Note: T ...

  • Newcon Optik LRM 220SI - page 22

    18 measured in the Scan ning m ode, though both will be quickly displayed, the second one m ay be di fficult to register by e ye. Nevertheless all data is recorded and may be recalled (see Data Recall mode for details.) Data Recall mode In Data Recall mode results of the last 10 measurements can be displayed. Measurement results are save d in on-bo ...

  • Newcon Optik LRM 220SI - page 23

    19 Pressing A button at any moment within the list of recalled results brings the unit to Ready to Measure mode. Choosing cLr at the end of recalled data will erase the device memory. Additional display i nformation Additional indicat ion is displ ayed i n Ready to Measure mode: Y or M Indicates that distance is displayed in ya rds or meters; eleva ...

  • Newcon Optik LRM 220SI - page 24

    20 6. BEST MEASURING TECHNIQUE Laser range finder measures di stance by catching laser beam reflected from the target. Ever ything that improves reflection increases the measurement reliability and maximum range. 1. Use tripod when ranging remote targ ets. The longer is the distance, the greater is the be a m shift due to hand t remor. 2. Aim at a ...

  • Newcon Optik LRM 220SI - page 25

    21 7. STORAGE AN D MAINTENANCE The unit is a s ophisticated precisi on optical i nstrument equi pped with laser and electronics. Ther efore, it should be handled with due care.  Keep away from direct sunlight.  Avoid impacts, jolts, dust, moisture, and sharp changes of temperature.  Do not use the device at temperatures higher than 50 o C ...

  • Newcon Optik LRM 220SI - page 26

    22 8. TROUBLESHOOTING The ranging does not work. The displa y is transparent. Check the charge of the battery. Replace it if it is weak. The ranging mode does n ot work. The display shows res ults of the last measurement or is transp arent. Wait for 16 second s, and press the Actio n button again. Compass show s zero at any direction. Wait for 8 se ...

  • Newcon Optik LRM 220SI - page 27

    23 9. WARRANTY NEWCON warrants this product against defects in m aterial and workmanshi p for one year from the date of the ori ginal pur chase. Longer warranty is available, subject to the terms of the specific sales contract. Should your Newcon product pr ove to be defective during this p eriod, pleas e deliver the product securely packaged in it ...

  • Newcon Optik LRM 220SI - page 28

    24 10. CUSTOMER SUPPORT Should you experien ce any difficulties with your NEWCON OPTIK product, consult this manual first. If the problem remains unresolved, c ontact our cust omer suppo rt departm ent at (416) 663-6963 or toll f ree at 1-877-368-6666 . Our operating hours are 9am-5pm , Monday - Friday , Eastern St andard Tim e. At no tim e should ...

  • Newcon Optik LRM 220SI - page 29

    25 11. QUALITY CERTI FICATE The unit has passed the quality inspection. Production date Serial number Quality Inspector Purchase date ...

  • Newcon Optik LRM 220SI - page 30

    26 ...

  • Newcon Optik LRM 220SI - page 31

    27 ...

  • Newcon Optik LRM 220SI - page 32

    NEWCON OPTIK  Printed in Canada R1 – 02.12 ...

Fabricant Newcon Optik Catégorie Hunting Equipment

Les documents que nous recevons du fabricant de l'appareilNewcon Optik LRM 220SI peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Newcon Optik
- manuels d’utilisations LRM 220SI
- fiches produit Newcon Optik
- dépliants
- ou étiquettes-énergie Newcon Optik LRM 220SI
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Newcon Optik LRM 220SI.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Newcon Optik LRM 220SI, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Newcon Optik LRM 220SI. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Newcon Optik LRM 220SI.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Newcon Optik LRM 220SI, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Newcon Optik LRM 220SI par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Newcon Optik LRM 220SI.

Le manuel d’utilisation complet Newcon Optik, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Newcon Optik LRM 220SI - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Newcon Optik LRM 220SI, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lNewcon Optik LRM 220SI qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Newcon Optik LRM 220SI - qui devraient nous aider dans les premières étapes lors de l'utilisation Newcon Optik LRM 220SI
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Newcon Optik LRM 220SI
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Newcon Optik LRM 220SI dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Newcon Optik LRM 220SI?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Newcon Optik LRM 220SI, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Newcon Optik LRM 220SI il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)