Manuel d’utilisation SAF OPAL Ethernet IP Interface MS6 SERIES

14 pages 8.55 mb
Télécharger

Aller à la page of 14

Summary
  • SAF OPAL Ethernet IP Interface MS6 SERIES - page 1

    Opal Pro to Mod TCP Page 1 Opal Pro MS6 SER IES AB Ethernet I P Interface Users Manual Revision 1.00 ...

  • SAF OPAL Ethernet IP Interface MS6 SERIES - page 2

    Opal Pro to Mod TCP Page 2 ...

  • SAF OPAL Ethernet IP Interface MS6 SERIES - page 3

    Opal Pro to Mod TCP Page 3 FOR YOUR SAFETY Only qualified personnel shoul d install this equipment, after first reading and understanding all the information in this manual. All instructions should be strictly adhered to. The user should consult Brock Solutions or a SAF OPAL Starters supplier for clarification of the contents of t his manual should ...

  • SAF OPAL Ethernet IP Interface MS6 SERIES - page 4

    Opal Pro to Mod TCP Page 4 ...

  • SAF OPAL Ethernet IP Interface MS6 SERIES - page 5

    Opal Pro to Mod TCP Page 5 Table of Conten ts INTRODUCTION .............................................................................................. 6 HARDWARE .................................................................................................... 6 JUMPER SET TINGS ................................................................. ...

  • SAF OPAL Ethernet IP Interface MS6 SERIES - page 6

    Opal Pro to Mod TCP Page 6 Opal Pro to Mod TC P Introduction The Opal Pro can be m onitored and controlled over an Ethernet communication network using the AB Ethernet IP pr otocol. The Opal Pro connects to the Ether net network through and optional Ethernet card that is mounted on the m ain Opal Pro control car d (CA530). Access is g ained to the ...

  • SAF OPAL Ethernet IP Interface MS6 SERIES - page 7

    Opal Pro to Mod TCP Page 7 LED Indicators Two bi-colour (red/green) LED indicators are mount ed beside the network connector. The upper LED indicates the Ethernet interface card stat us. LED State Ethernet Interface Card Status OFF No power Flashing Red Recoverable configuration fault ( card is not configured, contact Br ock Solutions for support) ...

  • SAF OPAL Ethernet IP Interface MS6 SERIES - page 8

    Opal Pro to Mod TCP Page 8 Op al Pro Paramete r Settings The parameters in t he Opal Pro used to con figure the Ehernet inter face card (group 14) ar e only accessible if a Ethernet interface card is inst alled. The parameter sett ings are as follows: Opal Pro Parameter Setting Description 2.02 Comm Module Ethernet Type of interface car d installed ...

  • SAF OPAL Ethernet IP Interface MS6 SERIES - page 9

    Opal Pro to Mod TCP Page 9 15.04 Comm Fault Enable Disable Enable – Opal Pro trips out on a communication fault Disable – Nothing happens on a communication fault 15.05 Comm Fault Time 0.1 to 5.0 secs This is the time sett ing that the Opal Pro uses to detect a communication fault. Bit 15 of the command word must change state twice with in the ...

  • SAF OPAL Ethernet IP Interface MS6 SERIES - page 10

    Opal Pro to Mod TCP Page 10 I/O Configuration The Opal Pro supports 4 input words and 51 output words. Their description is as follows: Input Words (Polled) AB Ethernet IP Name Description Bit 0 – Run Command Bit 1 – Jog Command Bit 2 – Reverse Comm and Bit 3 – Reset Command Bit 4 – DCI/Soft Stop Enable Bit 5 – Reserved Bit 6 – Reserv ...

  • SAF OPAL Ethernet IP Interface MS6 SERIES - page 11

    Opal Pro to Mod TCP Page 11 Output Words (Polled) AB Ethernet IP Name Description Bit 0 – Ready to Run (dr ive is enable and has 3 phase power) Bit 1 –Running (start is regulating) Bit 2 – Full On (star ter is phased fully on) Bit 3 – Up to Speed (st arted is phased fully on and the curr ent is below 105% of nameplate cur rent as set in 13. ...

  • SAF OPAL Ethernet IP Interface MS6 SERIES - page 12

    Opal Pro to Mod TCP Page 12 Relay Status Status of the Relay O utputs Bit 0 – Running Bit 1 – By-Pass Bit 2 – Shorted SCR Bit 3 – Reverse 1.07 Input Word 9 Bit 4 – Faulted 1.08 Input Word 10 Analog Output Analog Output value in Volts X 100 2.01 Input Word 11 Stack Size Opal Pro Stack Size in Amps 2.02 Input Word 12 Comm Module Type 0 – ...

  • SAF OPAL Ethernet IP Interface MS6 SERIES - page 13

    Opal Pro to Mod TCP Page 13 12.01 Input Word 27 Analog Output 16 = Current Refer ence 17 = Current Feedback 18 = Overload level 19 = Phase Angle 13.01 Input Word 28 Motor Amps Motor nameplate cur rent in Amps 13.02 Input Word 29 Motor Volts Motor nameplat e volts in Volts 13.03 Input Word 30 Service Factor Motor nameplate ser vice factor x 100 14.0 ...

  • SAF OPAL Ethernet IP Interface MS6 SERIES - page 14

    Opal Pro to Mod TCP Page 14 NOTE: The Opal Pro must have firmw are version 1.70 or higher. ...

Fabricant SAF OPAL Catégorie Network Card

Les documents que nous recevons du fabricant de l'appareilSAF OPAL Ethernet IP Interface MS6 SERIES peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques SAF OPAL
- manuels d’utilisations Ethernet IP Interface MS6 SERIES
- fiches produit SAF OPAL
- dépliants
- ou étiquettes-énergie SAF OPAL Ethernet IP Interface MS6 SERIES
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation SAF OPAL Ethernet IP Interface MS6 SERIES.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation SAF OPAL Ethernet IP Interface MS6 SERIES, manuels d’entretien, brefs manuels ou manuels de l’utilisateur SAF OPAL Ethernet IP Interface MS6 SERIES. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit SAF OPAL Ethernet IP Interface MS6 SERIES.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil SAF OPAL Ethernet IP Interface MS6 SERIES, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser SAF OPAL Ethernet IP Interface MS6 SERIES par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs SAF OPAL Ethernet IP Interface MS6 SERIES.

Le manuel d’utilisation complet SAF OPAL, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel SAF OPAL Ethernet IP Interface MS6 SERIES - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières SAF OPAL Ethernet IP Interface MS6 SERIES, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lSAF OPAL Ethernet IP Interface MS6 SERIES qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil SAF OPAL Ethernet IP Interface MS6 SERIES - qui devraient nous aider dans les premières étapes lors de l'utilisation SAF OPAL Ethernet IP Interface MS6 SERIES
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de SAF OPAL Ethernet IP Interface MS6 SERIES
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service SAF OPAL Ethernet IP Interface MS6 SERIES dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de SAF OPAL Ethernet IP Interface MS6 SERIES?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec SAF OPAL Ethernet IP Interface MS6 SERIES, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec SAF OPAL Ethernet IP Interface MS6 SERIES il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)