    HOTWIRE  8610 DSLAM INST ALLA TION INSTRUCTIONS Document No. 8610-A2-GN10-10 ...

  • Paradyne 8610 - page 2

    Copyright E 1999 Paradyne Corporation. All rights reserved. Printed in U.S.A. Notice This publication is protected by federal copyright law . No part of this publication may be copied or distributed, transmitted, transcribed, stored in a retrieval system, or translated into any human or computer language in any form or by any means, electronic, mec ...

  • Paradyne 8610 - page 3

    TM 1 Hotwire r 8610 DSLAM Installation Instructions Document Number 8610-A2-GN10-10 May 1999 Product Documentation on the W orld W ide W eb We provide complete product documentation online. This lets you search the documentation for specific topics and print only what you need, reducing the waste of surplus printing. It also helps us maintain compe ...

  • Paradyne 8610 - page 4

    2 About This Document This guide is written for administrators and technicians who install devices at the central office (CO) or at a Network Service Provider (NSP) location adjacent to the CO. It should be used in conjunction with the appropriate Hotwire DSL card User ’ s Guide or Network Configuration Guide, which describes how to plan the data ...

  • Paradyne 8610 - page 5

    3 The 8610 DSLAM accepts the following types of cards: H Management Control Processor (MCP). This is a processor card that administers and provides diagnostic connectivity to the DSL cards. It acts as a mid-level manager and works in conjunction with an SNMP network management system, such as HP OpenView , via its LAN port. It gathers operational s ...

  • Paradyne 8610 - page 6

    4 H Stackable Chassis for DSL Access Growth Each chassis is an independent, standalone system. The 8610 and 8600 chassis are interoperable in a stack. The stackable design provides for six systems to share management access through a single MCP card (for 8610) or MCC card (for 8600) which, in turn, allows an additional slot for a DSL card in each o ...

  • Paradyne 8610 - page 7

    5 Hotwire 8610 DSLAM Components 99-16311 TM TM STA CK POSITION 2 3 6 5 4 1 AC INPUT 1 2 3 ESD ESD 48VDC CLASS 2 OR LIMITED PWR SOURCE 48V A RTN AB B A B DC FUSES T4A, MIN. 48V PWR A ALM FAN B OUT IN SERIAL ALM INTF MCP/1 2 3 MCP/ DSL MANAGEMENT 10 BASE T 8610 MCP 8000 SYSTEM OK Alrm T est TX RX Coll ETHERNET SYSTEM OK Alrm T est TX RX Col 1 2 3 4 E ...

  • Paradyne 8610 - page 8

    6 Preinstallation Considerations Consider the following before performing installation of the 8610 chassis: H Installation Site Y our installation site should be well ventilated, clean, and free of environmental extremes. If you are installing the Hotwire 8610 DSLAM chassis in a central office rack, make sure there is 2 to 3 feet of clearance at th ...

  • Paradyne 8610 - page 9

    7 — 14-foot serial cable and DB25 and DB9 adapters are shipped with the MCP card. For connection to a modem, you will need a NULL modem adapter . If there is adequate maintenance space at the rear of the rack, mount the chassis on the rack before installing cables. If there is inadequate space to do this, install the rear-mounted network connecto ...

  • Paradyne 8610 - page 10

    99-16309 TM TM STACK POSITION 2 3 6 5 4 1 AC INPUT 1 2 3 ESD ESD 48VDC CLASS 2 OR LIMITED PWR SOURCE 48V A RTN AB B A B DC FUSES T4A, MIN. 48V PWR A ALM FAN B OUT IN SERIAL ALM INTF MCP/1 2 3 MCP/ DSL MANAGEMENT 10 BASE T 8610 MCP 8000 SYSTEM OK Alrm Tes t TX RX Coll ETHERNET SYSTEM OK Alrm Test TX RX Col 1 2 3 4 ETHERNET DSL PORT RADSL 8546 SYSTEM ...

  • Paradyne 8610 - page 11

    TM T M STACK POSITION 2 3 6 5 4 1 AC INPUT 1 2 3 E S D E S D 48VDC CLASS 2 OR LIMITED PW R SOURCE 48V A R T N AB B A B DC FUSES T4A, M IN. 48V PW R A ALM FAN B O U T IN S E R IA L A LM IN T F M C P /1 2 3 M CP/ DSL M A N A G E M E N T 10 B A S E T 8610 TM T M STACK POSITION 2 3 6 5 4 1 AC INPUT 1 2 3 E S D E S D 48VDC CLASS 2 OR LIM ITED PW R SOURC ...

  • Paradyne 8610 - page 12

    10 Interconnecting 8610 Systems " Procedur e T o interconnect multiple 8610 systems: 1. Connect the end of an 8-pin modular cable into the Management OUT port of the base chassis. 2. Dress the 8-pin modular cable to the left and under the chassis, behind the foot, and up the side of the unit. 3. Plug the other end of the 8-pin modular cable in ...

  • Paradyne 8610 - page 13

    11 The following illustration shows the designated number for each DSL card slot in a stack. NOTE: This illustration shows a stack of six Hotwire 8610 systems, which is valid for rack mounting. However , the same relationship of software-assigned slot numbers applies to two stacks of three each, mounted on a desk or tabletop and connected by a bus ...

  • Paradyne 8610 - page 14

    19-Inch Rack 23-Inch Rack 98-15451a F ront Rail 99-16314 ESD 12 Installing the 8610 Chassis in a Rack with Threaded Scr ew Holes NOTE: Y ou may want to install the three supplied #4-40 Phillips pan-head screws for the rear T elco connectors on the rear connectors before rack mounting the DSLAM. This will make them readily available when needed. See ...

  • Paradyne 8610 - page 15

    99-16315 Speed Nut F ront Rail ESD 13 Installing the 8610 Chassis in a Rack without Threaded Scr ew Holes " Procedur e T o install the 8610 chassis in a rack that does not have threaded screw holes: 1. Install the mounting brackets on the 8610 chassis. — For a 19-inch rack installation, the notched flange of the mounting bracket is placed ag ...

  • Paradyne 8610 - page 16

    496-15149 14 Center -Mounting the 8610 Chassis in a Rack " Procedur e T o center-mount the 8610 chassis in a rack: 1. Determine the preferred placement of the 8610 chassis in the rack. Then, mark the appropriate locations for the mounting screws on the rack. 2. Reposition the mounting brackets to the center-mount position using the four #8-32 ...

  • Paradyne 8610 - page 17

    15 Supplying Power The Hotwire 8610 DSLAM chassis is available in two versions: H dc power (– 40.0 to – 60.0 Vdc; maximum current draw is 2 amps) — The dc version has two separate dc inputs, A and B, to provide power redundancy . H ac power (100–250V ; 50–60 Hz; maximum current draw is 3 amps @ 1 10 V ac) — The ac version can provide po ...

  • Paradyne 8610 - page 18

    T M T M STACK POSITION 2 3 6 5 4 1 AC INPUT 1 2 3 E S D E S D 48VDC CLASS 2 OR LIMITED PW R SOURCE 48V A R TN AB B A B DC FUSES T4A, M IN. 48V PW R A ALM FAN B O U T IN SE R IA L A LM IN T F M C P /1 2 3 M CP/ DSL M A N A G E M E N T 10 B A S E T 8610 99-16316 RTN –48V A AB B 16 2. Dress the wires under the 8610 chassis to the left behind the sup ...

  • Paradyne 8610 - page 19

    99-16317 TM T M STACK POSITION 2 3 6 5 4 1 AC INPUT 1 2 3 E S D E S D 48VDC CLASS 2 OR LIMITED PW R SOURCE 48V A R TN AB B A B DC FUSES T4A, MIN. 48V PW R A ALM FAN B O U T IN S E R IA L A LM IN T F M C P /1 2 3 M C P/ D SL M A N A G E M E N T 10 B A S E T 8610 RTN –48V A AB B TM T M STACK POSITION 2 3 6 5 4 1 AC INPUT 1 2 3 E S D E S D 48VDC CLA ...

  • Paradyne 8610 - page 20

    TM T M STACK POSITION 2 3 6 5 4 1 AC INPUT 1 2 3 E S D E S D 48VDC CLASS 2 OR LIMITED PW R SOURCE 4 8V A R T N AB B A B DC FUSES T4A, MIN. 48V PW R A ALM FAN B O U T IN S E R IA L A LM IN T F M C P /1 2 3 M CP/ D SL M A N A G E M E N T 10 B A S E T 8610 99-16319 INPUT AC RTN –48V A AB B 48VDC CLASS 2 OR LIMITED PWR SOURCE 18 2. Insert the wires f ...

  • Paradyne 8610 - page 21

    19 When swapping a new card for an old card, it is important to note that the 8610 DSLAM retains the Media Access Control (MAC) address, also referred to as the physical address. This means that the new card will have the same MAC address as the old one. NOTES: — All standalone 8610 chassis (i.e., chassis that are not daisy-chained to other Hotwi ...

  • Paradyne 8610 - page 22

    20 NOTE: For detailed information about the configuration and operation of the circuit card, see the appropriate card User ’ s Guide. V erifying the Installation T o verify the hardware installation, observe the following indicators: H The PWR A and/or PWR B LEDs on the front panel must be in the ON state (green): — If you are using a single ? ...

  • Paradyne 8610 - page 23

    21 NOTE: If you are connecting the Hotwire 8610 DSLAM to a CO POTS splitter , this procedure assumes that the CO POTS splitter shelf is already installed. For information on how to install the CO POTS splitter , refer to the Hotwire POTS Splitter Central Office Installation Instructions , Document No. 5020-A2-GN10. Installing Network Tip and Ring C ...

  • Paradyne 8610 - page 24

    22 Connecting Ethernet Connections to the IPC or Ethernet Hubs Use this procedure for connecting RADSL and MVL cards to the IPC or Ethernet hubs. For other types of cards, refer to the appropriate Installation Instructions. " Procedur e T o connect the DSL cards to the Ethernet hubs or switches: 1. Plug the end of an 8-pin modular cable into t ...

  • Paradyne 8610 - page 25

    23 Connecting to a T erminal or Laptop Computer " Procedur e T o connect the Hotwire 8610 DSLAM chassis to a terminal or laptop computer: 1. Connect the serial cable with 8-pin modular plugs on each end (provided with the MCP card) into the MANAGEMENT SERIAL port of the chassis. 2. Dress the serial cable under the 8610 chassis, to the left and ...

  • Paradyne 8610 - page 26

    24 Connecting to a Modem for Remote Management Before connecting the Hotwire 8610 DSLAM to a dial-up modem, configure the modem with the following settings: H Set the modem for auto answer . For example, A TS0=1 . H T urn off character echo. For example, A TE0. H Enable result codes in originate mode only . For example, A TQ2. H Set the modem to ig ...

  • Paradyne 8610 - page 27

    25 Connecting CO Alarm to the Alarm System The following procedure is optional. Follow this procedure only if you want to connect to a CO alarm system. See 8-Pin Modular Connector for Alarm Relay Interface on page 28 for pin-out information. " Procedur e T o connect the 8610 DSLAM to a CO alarm system: 1. Plug the 8-pin modular cable into the ...

  • Paradyne 8610 - page 28

    26 Symptom Solutions Possible Cause System Alarm LED is ON (on a DSL card) SYSTEM ALM LED is ON and DSL card is inoperative in Slot n . 1. Choose Card Selection from the Main Menu to display the status of each DSL card. 2. If a major alarm is indicated, reset the MCP card ( A-A-F ). Then, reset the DSL card ( A-A-E ). 3. Remove and reinstall the ca ...

  • Paradyne 8610 - page 29

    27 LEDs The following table describes the meaning and states of the LEDs on the front panel of the DSLAM chassis. For individual card LEDs, see the appropriate card Installation Instructions. LED LED is . . . Indicating . . . PWR A Green Off Normal operation for Power Source A. Low , high, or no voltage for Power Source A. PWR B Green Off Normal op ...

  • Paradyne 8610 - page 30

    97-15449 Pin 1 Pin 8 97-15449 Pin 1 Pin 8 28 Pinouts 8-Pin Modular Connector for Alarm Relay Interface The 8-pin interface for the Alarm Relay Interface (ALM INTF) connection has the following pin assignments. Pin Number Use 1 Not used 2 Closed on major alarm 3 Common on major alarm 4 Open on major alarm 5 Closed on minor alarm 6 Common on minor al ...

  • Paradyne 8610 - page 31

    97-15449 Pin 1 Pin 8 97-15449 Pin 1 Pin 8 29 8-Pin Modular Management In and Out Connector The 8-pin interface for the Management In and Out connections has the following pin assignments. Pin Number Use 1 Mgt. Data + 2 Mgt. Data – 3 Fan Alarm 4 Ground 5 Power Alarm A 6 Power Alarm B 7 Mgt. Clk + 8 Mgt. Clk – 8-Pin Modular Serial (Asynchronous T ...

  • Paradyne 8610 - page 32

    99-15388a 99-16049a 30 DB25 Adapter Pinouts The DB25 (RS-232 male) cable adapter is used to convert the 8-pin modular serial interface to a standard RS-232 DB25 interface, which can then be connected to a terminal, computer , or any Data T ermination Equipment (DTE). Connection to a modem requires a null modem adapter . The following table lists th ...

  • Paradyne 8610 - page 33

    26 97-15526 50 1 25 31 T elco 50-Pin Connector Pinouts for DSL Loops and POTS Splitters The three T elco 50-pin receptacles on the rear of the chassis (labeled for Slots 1, 2, 3) provide the 2-wire loop interface from each DSL port to either the POTS splitter card or , if the loop is not being shared with POTS, then to the Main Distribution Frame ( ...

  • Paradyne 8610 - page 34

    32 T echnical Specifications The following table lists the technical specifications for the Hotwire 8610 DSLAM chassis: Specifications Criteria* Physical Dimensions Height: 4.7 inches (1 1.94) Width: 17.2 inches (43.69 cm) Depth: 10.5 inches (26.67 cm) Weight: 9 pounds (4.08 kg) Three chassis can be safely placed on top of each other on a desktop o ...

  • Paradyne 8610 - page 35

    33 Specifications Criteria* Grounding A ground lug is located on the right rear of the Hotwire 8610 DSLAM. It accepts 14 A WG wire. A noninsulated banana jack is located at the left front of the 8610 DSLAM providing a ground for the ESD wrist strap plug. Cooling and Air Handling The internal fan module is installed in the chassis to provide cooling ...

  • Paradyne 8610 - page 36

    34 6. General purpose cables are provided with this product. Special cables, which may be required by the regulatory inspection authority for the installation site, are the responsibility of the customer . 7. When installed in the final configuration, the product must comply with the applicable Safety Standards and regulatory requirements of the co ...

  • Paradyne 8610 - page 37

    35 ! W ARNING: T o Users of Digital Apparatus in Canada: This Class A digital apparatus meets all requirements of the Canadian interference-causing equipment regulations. Cet appareil numérique de la classe A respecte toutes les exigences du règlement sur le matérial brouilleur du Canada. Notice to Users of the Canadian T elephone Network The In ...

  • Paradyne 8610 - page 38

    36 CE Marking When the product is marked with the CE mark, this demonstrates full compliance with the following European Directives: H Directive 72/73/EEC – Council Directive of 19 February 1973 on the harmonization of the laws of the member states relating to electrical equipment designed for use within certain voltage limits, as amended by Dire ...

Fabricant Paradyne Catégorie Network Card

Les documents que nous recevons du fabricant de l'appareilParadyne 8610 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Paradyne
- manuels d’utilisations 8610
- fiches produit Paradyne
- dépliants
- ou étiquettes-énergie Paradyne 8610
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Paradyne 8610.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Paradyne 8610, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Paradyne 8610. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Paradyne 8610.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Paradyne 8610, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Paradyne 8610 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Paradyne 8610.

Le manuel d’utilisation complet Paradyne, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Paradyne 8610 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Paradyne 8610, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lParadyne 8610 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Paradyne 8610 - qui devraient nous aider dans les premières étapes lors de l'utilisation Paradyne 8610
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Paradyne 8610
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Paradyne 8610 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Paradyne 8610?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Paradyne 8610, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Paradyne 8610 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)