  • American Power Conversion AP7922 - page 1

    Switche d Rac k Power D istribution Un it AP7922 Installation and Quick Start ...

  • American Power Conversion AP7922 - page 2

    This manual is available in English on the enclosed CD. Dieses Handbuch ist in Deutsch auf der beiliegenden CD-ROM verfügbar . Este manual está dispon ible en español en el CD-ROM adjunto. Ce manuel est disponib le en français sur le C D-ROM ci-inclus. Questo manuale è disponibil e in italiano nel CD-ROM allegato. Instr ukcja Obsl ugi w jêzyk ...

  • American Power Conversion AP7922 - page 3

    Contents Switched Ra ck PDU Insta llation and Quick Star t i Produ ct Descript ion and Inventor y . . . . . . . . . . . . . . . . . . . . . . 1 AP7922 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Additional documen tation . . . . . . . . . . . . . . . . . . . . . . . . . 2 Inventor y . . . . . . . . . . . . . . . . ...

  • American Power Conversion AP7922 - page 4

    ii Switched Ra ck PDU Insta llation and Quick Star t Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 AP7922 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 Warrant y and Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Limited warranty . . . . . . . . ...

  • American Power Conversion AP7922 - page 5

    Switched Ra ck PDU Insta llation and Quick Star t 1 Pr oduct Description and Inventory AP7922 is a Switched Rac k Power Dist ribution Unit (Rack PDU) t hat dist ributes power to device s in the rack. The use r can turn on, t urn of f, or recycl e power back to t he individu ally contr olled out lets. The Rack PDU also ha s a senso r that measur es ...

  • American Power Conversion AP7922 - page 6

    Product Descripti on and In ventory 2 Switched Rack PDU Installation and Q uick Start Additiona l documentatio n The Rack PDU Us er’ s Gui de and the Rac k PDU Addendum a re avail able on the su pplied CD and on the APC W eb site: www .apc.co m . The User’ s Guide (.doceng usrg uide.pdf) cont ains additi onal informat ion about the fo llowin ...

  • American Power Conversion AP7922 - page 7

    Switched Ra ck PDU Insta llation and Quick Star t 3 How to Install the Rack PDU Installation guidelines • For a Ra ck PDU inst alled i n an enc losed co mmunicati ons rac k, the recommen ded maximum ambie nt tempera ture is 45° C ( 11 3º F). • Instal l the Rack PDU so that i t does not reduce th e air fl ow requir ed for saf e operati on of t ...

  • American Power Conversion AP7922 - page 8

    How to Install the Rack PDU 4 Switched Rack PDU Installation and Q uick Start Attach cor ds to the tray Attach a cord to t he tray by loop ing th e cord and s ecuring i t to the tray , using a wi re tie ( provided) . Cords fro m both banks o f outlet s may be secured to the bot tom tray , or you may a ttach an addi tional t ray (shown on the pr ece ...

  • American Power Conversion AP7922 - page 9

    How to Install the Rack PDU Switched Ra ck PDU Insta llation and Quick Star t 5 For a r ecessed placement : use four flat-he ad scr ews (provid ed) through t he last four ho les of ea ch bracket . 2. Insert caged nut s (provi ded with t he ra ck) on the vertic al mountin g rails above a number at the st art of two U-spa ces in your encl osure and b ...

  • American Power Conversion AP7922 - page 10

    6 Switched Rack PDU Installation and Q uick Start Operation Disp lay inte rfac e Link - Rx/Tx 10 / 100 Status Serial Port Rese t - W ar ning - OK - Overl oad      B2 B1 TOT AL Amps Amps Amps Switch ed Rack PDU     Line Indicator LED: In dicates normal (green), warning (yellow), and alarm (red) conditions for bank 1 (B 1 ) ...

  • American Power Conversion AP7922 - page 11

    Switched Ra ck PDU Insta llation and Quick Star t 7 Quick Configuration Over v iew Y ou must configure t he followi ng TCP/IP sett ings befor e the Rack PDU can oper ate on a net work: • IP addre ss of the Rack P DU • Subnet mask • De fault g atewa y TCP/IP configuration methods Use one of the foll owing methods to define the TCP/IP settings: ...

  • American Power Conversion AP7922 - page 12

    Quick Configuration 8 Switched Rack PDU Installation and Quick Start APC Manageme nt Car d Wizar d Y ou can use the APC Management Card Wizard at a W indows ® 98, W indows NT ® 4.0, W indows 2000, or W indows XP computer to configure a Rack PD U. 1. Insert the APC Switche d Rack PDU Utility CD into a computer on your network. 2. Launch the W izar ...

  • American Power Conversion AP7922 - page 13

    Quick Configur ation Switched Ra ck PDU Insta llation and Quick Star t 9 BOOTP . Y ou can use an RFC95 1 -com plia nt B OOTP ser ver t o co nfig ure the TCP/I P settings f or the Rack PDU. If the BOOTP serv er is pro perly configur ed, the Rac k PDU’ s default setting ( DHCP & BOOTP ) fo r BOOT Mode causes it t o discove r the BOOTP server . ...

  • American Power Conversion AP7922 - page 14

    Quick Configuratio n 10 Switched Ra ck PDU Insta llation and Quick Sta rt DHCP . Y ou can use a RFC2 1 3 1 /RFC2 1 32-compl iant DHCP ser ver to configur e the TCP/I P settin gs for the Rack PDU. 1 . The Rack PDU se nds a DHCP reque st that u ses the f ollowing to ident ify its elf: – V endor Class Identifi er (APC by de fault ) – Client Ide nt ...

  • American Power Conversion AP7922 - page 15

    Quick Configur ation Switched Ra ck PDU Insta llation and Quick Star t 11 Local access to the contr ol console Y ou can use a l ocal comput er to conn ect to th e Rack PDU to ac cess the control console. 1 . Select a serial port at t he local computer , and dis able any s ervice which uses that por t. 2. Use the c onfigura tion cabl e (940-0 1 44) ...

  • American Power Conversion AP7922 - page 16

    Quick Configuratio n 12 Switched Ra ck PDU Insta llation and Quick Sta rt 3. U se T el net to acc ess t he Ra ck PD U at its ne wl y assi gne d I P addr ess. F or e xampl e: telnet 156.205.14.141 4. Use apc for bot h user name and pas sword. 5. See “Contr ol consol e” on this page to f inish the configur ation. Contr ol console After yo u log o ...

  • American Power Conversion AP7922 - page 17

    Switched Ra ck PDU Insta llation and Quick Star t 13 How to Access a Config ur ed Rack PDU Over v iew After t he Rack PDU is runn ing on yo ur network, you can use the interf aces summari zed he re to acce ss the uni t. W eb i nterf ace As your br owser , you can use Microsoft ® I nternet Ex plorer 5. 0 (and higher) or Netsca pe ® 4.0.8 (an d hig ...

  • American Power Conversion AP7922 - page 18

    How to Access a Configured Rack PDU 14 Switched Ra ck PDU Insta llation and Quick Sta rt T elnet/ SSH Y ou can acces s the cont rol consol e through T elne t or Secur e SHell (SSH), depe nding on whic h is enabl ed. An Administ rator c an enable these ac cess metho ds through the T e lnet/S SH option of the Network menu. By defa ult, T elnet is ena ...

  • American Power Conversion AP7922 - page 19

    How to Access a Configu red Rack PDU Switched Ra ck PDU Insta llation and Quick Star t 15 FT P / S C P Y ou can use FTP (ena bled by def ault) or Secure CoPy ( SCP) to tr ansfer new firmwar e to the Rack PDU, o r to acce ss a copy of th e Rack PDU’ s event l ogs. SCP provi des the hi gher secur ity of encr ypted data transmi ssion and i s automat ...

  • American Power Conversion AP7922 - page 20

    16 Switched Ra ck PDU Insta llation and Quick Sta rt How to Recover Fr om a Lost Passwor d Y ou can use a local computer , a computer that connects to t he Rack PDU or other device t hrough the serial p ort to ac cess the c ontrol c onsole. 1 . Select a serial port at t he local computer , and dis able any s ervice that us es that po rt. 2. Connect ...

  • American Power Conversion AP7922 - page 21

    Switched Ra ck PDU Insta llation and Quick Star t 17 How to Download Firmwar e Updates Y ou can use a l ocal comput er that co nnects to the Rack PDU through th e serial port on t he front o f the unit. 1 . Select a serial port at t he local computer , and dis able any s ervice that us es that po rt. 2. Use the c onfigura tion cabl e (940-0 1 44) t ...

  • American Power Conversion AP7922 - page 22

    18 Switched Ra ck PDU Insta llation and Quick Sta rt Specifications AP79 22 Electrical Nominal input vo ltage 230 V Acceptable input voltage ± 1 0% Nominal input voltage Maximum total current draw 32 A Input frequency 47 – 63 Hz Cord le ngth 1 2 ft ( 1 44 in) Input conn ectors IEC 309, 32 A, 230 V , 1 ~ plug Output connectors Sixteen IEC 32 0 C ...

  • American Power Conversion AP7922 - page 23

    Switched Ra ck PDU Insta llation and Quick Star t 19 W arranty and Service Limi ted w arr anty APC warrants the Ra ck PDU to be fr ee from defec ts in mate rials an d workmanshi p for a per iod of two y ears fro m the date o f purchase . Its obligat ion under this warr anty is l imited to repairing or replaci ng, at it s own sole op tion, any s uch ...

  • American Power Conversion AP7922 - page 24

    20 Switched Ra ck PDU Insta llation and Quick Sta rt Life-Support Policy General po licy American Power Conversion (APC) doe s not recommend th e use of any of its p rodu cts in the follow ing situat ions: • In lif e-support applica tions wher e failur e or malfun ction of t he APC product can be rea sonably exp ected to cause fai lure of t he li ...

  • American Power Conversion AP7922 - page 25

    Radio Fr equency Interfer ence USA — FCC This equi pment has be en teste d and found t o comply wit h the limits for a Class A d igital devic e, pursu ant to part 1 5 of the FCC Rules . These limit s are designed to pro vide reas onable pro tection against h armful interfe rence when the equi pment is ope rated in a commercial environme nt. This ...

  • American Power Conversion AP7922 - page 26

    *990-1694-001* APC W orldwide Customer Suppo rt Custome r support fo r this or any other APC product is availa ble at no ch arg e in any of the f ollowing ways : • V isit the APC W eb site to find an swers to f requentl y asked ques tions (F AQs), to ac cess documents in the APC Knowl edge Base, an d to submit customer su pport req uests. – www ...

Fabricant American Power Conversion Catégorie Power Supply

Les documents que nous recevons du fabricant de l'appareilAmerican Power Conversion AP7922 peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques American Power Conversion
- manuels d’utilisations AP7922
- fiches produit American Power Conversion
- dépliants
- ou étiquettes-énergie American Power Conversion AP7922
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation American Power Conversion AP7922.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation American Power Conversion AP7922, manuels d’entretien, brefs manuels ou manuels de l’utilisateur American Power Conversion AP7922. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit American Power Conversion AP7922.

Manuel d’utilisation complet de l’appareil American Power Conversion AP7922, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser American Power Conversion AP7922 par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs American Power Conversion AP7922.

Le manuel d’utilisation complet American Power Conversion, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel American Power Conversion AP7922 - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières American Power Conversion AP7922, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lAmerican Power Conversion AP7922 qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil American Power Conversion AP7922 - qui devraient nous aider dans les premières étapes lors de l'utilisation American Power Conversion AP7922
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de American Power Conversion AP7922
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service American Power Conversion AP7922 dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de American Power Conversion AP7922?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec American Power Conversion AP7922, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec American Power Conversion AP7922 il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)