Manuel d’utilisation Oregon Scientific EMR812HGN

12 pages 0.34 mb
Télécharger

Aller à la page of 12

Summary
  • Oregon Scientific EMR812HGN - page 1

    1 EN MULTI-CHANNEL IN-OUT CABLE FREE THERMO-HYGROMETER MODEL : EMR812HGN USER’S MANUAL INTRODUCTION Congratulations on your purchase of the Multi-Channel In-Out Thermometer / Hygrometer (EMR812HGN) with a 433MHz cable- free thermo-hygro sensor. Enclosed with this package is one (1) main display unit and one (1) cable-free remote thermo-hygro sens ...

  • Oregon Scientific EMR812HGN - page 2

    2 EN A Extra large two-line Liquid Crystal Display (LCD) Multifunction display showing temperature and humidity, max./min. memory, and trend indicators for the main unit and remote sensors. B CHANNEL button - Selects among different channels - Activates remote sensor scanning mode C IN/REMOTE - Selects between the main-unit display and a selected r ...

  • Oregon Scientific EMR812HGN - page 3

    3 EN H Wall-mount holder Supports the remote unit in wall-mounting I Removable table stand For standing the remote unit on a flat surface BEFORE YOU BEGIN To ensure proper functioning of the EMR812HGN follow this setup procedure. For best operation: 1. Assign different channels to different remote units. 2. Insert batteries for remote units before ...

  • Oregon Scientific EMR812HGN - page 4

    4 EN Follow these steps to install / replace batteries: 1. Remove the screws on the battery compartment. 2. Select the channel number on the CHANNEL slide switch. 3. Select the temperature display unit on the ° C/ ° F slide switch. 4. Insert the batteries strictly according to the polarities shown therein. 5. Replace the battery compartment door ...

  • Oregon Scientific EMR812HGN - page 5

    5 EN GETTING STARTED Once batteries are placed in a given remote sensor unit, it will start transmitting information at 40-second intervals. Also, for approximately a 3-minute duration, the main unit will automatically search for signals once batteries are installed. Upon successful reception, the individual channel temperature reading will be disp ...

  • Oregon Scientific EMR812HGN - page 6

    6 EN The unit is in searching mode. Transmission data are securely registered. No signals. THE COMFORT-LEVEL ICONS The comfort level is based on the recorded relative humidity. An indicator will be displayed ot show if the level is comfortable, wet or dry. TEMPERATURE AND HUMIDITY TREND INDICATORS The temperature-trend and humidity-trend indicators ...

  • Oregon Scientific EMR812HGN - page 7

    7 EN To deactivate the remote-sensor scanning mode: ◊ Press any button. MAXIMUM AND MINIMUM TEMPERATURE AND HUMIDITY The maximum and minimum recorded temperature and humidity readings will automatically be stored in the memory. To display the maximum and minimum display memory: 1. Select the channel to be checked. 2. Press MEM/CLEAR once to displ ...

  • Oregon Scientific EMR812HGN - page 8

    8 EN Note: The temperature range is from -50 ° C (-58 ° F) to +70 ° C (158 ° F). If this is the first time you set the limits, the lower limit will start from -50 ° C (-58 ° F) and the upper limit +70 ° C (158 ° F). Otherwise, the reading will start from the temperature last selected. The humidity range is from 2% to 98%. If this is the fir ...

  • Oregon Scientific EMR812HGN - page 9

    9 EN TRANSMISSION COLLISION Signals from other household devices, such as door bells, home security systems and entry controls, may interfere with those of this product and cause temporarily reception failure. This is normal and does not affect the general performance of the product. The transmission and reception of temperature readings will resum ...

  • Oregon Scientific EMR812HGN - page 10

    10 EN THE RESET BUTTON This button is only used when the unit is operating in an unfavorable way or malfunctioning. Use a blunt stylus to hold down the button. All settings will return to their default values. PRECAUTIONS This product is engineered to give you years of satisfactory service if you handle it carefully. Here are a few precautions: 1. ...

  • Oregon Scientific EMR812HGN - page 11

    11 EN General RF Transmission Frequency : 433 MHz No. of Remote unit : Maximum of 3 RF Transmission Range : Maximum 30 meters Temperature compensation : 0.1 ° C to ( 0.2 ° F) Temperature sensing cycle : around 40 seconds Power Main unit : 2 pcs UM-3 or “AA” 1.5V alkaline batteries Remote sensing unit : 2 pcs UM-4 or “AAA” 1.5V alkaline ba ...

  • Oregon Scientific EMR812HGN - page 12

    12 EN EC-DECLARATION OF CONFORMITY This product complies with the essential requirements of Article 3 of the R&TTE 1999 / 5 / EC Directive, if used as intended and the following standards have been applied: Safety of information technology equipment (Article 3.1.a of the R&TTE Directive) Applied Standard EN 60950: 2000 Electromagnetic compa ...

Fabricant Oregon Scientific Catégorie Thermometer

Les documents que nous recevons du fabricant de l'appareilOregon Scientific EMR812HGN peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Oregon Scientific
- manuels d’utilisations EMR812HGN
- fiches produit Oregon Scientific
- dépliants
- ou étiquettes-énergie Oregon Scientific EMR812HGN
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Oregon Scientific EMR812HGN.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Oregon Scientific EMR812HGN, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Oregon Scientific EMR812HGN. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Oregon Scientific EMR812HGN.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Oregon Scientific EMR812HGN, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Oregon Scientific EMR812HGN par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Oregon Scientific EMR812HGN.

Le manuel d’utilisation complet Oregon Scientific, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Oregon Scientific EMR812HGN - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Oregon Scientific EMR812HGN, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lOregon Scientific EMR812HGN qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Oregon Scientific EMR812HGN - qui devraient nous aider dans les premières étapes lors de l'utilisation Oregon Scientific EMR812HGN
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Oregon Scientific EMR812HGN
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Oregon Scientific EMR812HGN dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Oregon Scientific EMR812HGN?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Oregon Scientific EMR812HGN, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Oregon Scientific EMR812HGN il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)