Manuel d’utilisation Topcon COMPUTERIZED TONOMETER

59 pages 1.67 mb
Télécharger

Aller à la page of 59

Summary
  • Topcon COMPUTERIZED TONOMETER - page 1

    INSTRUCTION MANUAL COMPUTERIZED TONOMETER CT - 80 ...

  • Topcon COMPUTERIZED TONOMETER - page 2

    INTRODUCTION Thank you for purchasing the TOPCON Computer- ized Tonometer CT-80. (To get the best use from the instrument, please carefully read these instructions and keep this Instruction Manual in a convenient location for future reference.) This instrument features the following: • An exact, non-contact intraocul ar pressure measurement that ...

  • Topcon COMPUTERIZED TONOMETER - page 3

    DISPLAY FOR SAFE USE In order to encourage the safe use of the product and prevent any danger to the operator and others or damage to properties, important warni ngs are placed on the product and inserted in the instruction manual. We suggest that everyone understand the meaning of the following displays and icons before reading the “Safety Cauti ...

  • Topcon COMPUTERIZED TONOMETER - page 4

    SAFETY CAUTIONS Icons Prevention item Page To avoid electrical shock, do not open the instrument. Refer all servicing to qualified personnel. 45 To avoid electric shocks, do not remove the cov ers from the bottom and top surfaces, TV monitor, measuring unit, etc. 45 To prevent shock hazard, do not allow water or other foreign matter to enter into t ...

  • Topcon COMPUTERIZED TONOMETER - page 5

    SAFETY CAUTIONS Icon Prevention item Page To avoid potential injury, hold the instrument in the proper position. 13 To avoid electrical shock, do not handle the power plug with wet fingers. 14 Never insert your fingers under the measuring head. ∗ Inform the patient of this, too. Careless insertion of fingers may cause injury by pinching. 30 Never ...

  • Topcon COMPUTERIZED TONOMETER - page 6

    USAGE AND MAINTENANCE PURPOSE This tonometer “CT-80” is a precision elec trical device for medical use that must be used under the instruction of a doctor. USER MAINTENANCE To maintain the safety and performance of the equipment, never attempt to do mainte- nance on your own. Ask our serviceman for repair except for the items specified here whi ...

  • Topcon COMPUTERIZED TONOMETER - page 7

    WARNING INDICATIONS AND POSITIONS To ensure the safe usage of this equipment, precaution indications are provided. Abide by the following warning instructions . If any of the following labels are missing, please contact us at the address prin ted on the back cover of this manual. 6 WARNING • To avoid electrical shock, do not open the instrument. ...

  • Topcon COMPUTERIZED TONOMETER - page 8

    CONTENT Introduction 1 Display for Safe Use 2 Safety Cautions 3 Usage and Maintenance 5 Escape Clause 5 Warning Indications and Positions 6 NAMES OF COMPONENTS Main Body Components 8 Control Panel Components 9 Monitor Screen Components 10 Contents of Printer Output 11 Standard Accessories 12 PREPARATIONS How to Install the Instrument 13 How to Conn ...

  • Topcon COMPUTERIZED TONOMETER - page 9

    COMPONENTS MAIN BODY COMPONENTS 8 COMPONENTS Measuring window cap Measuring head Clamping knob Safety stopper knob Control panel External I/O terminal TV Monitor Measuring switch Control lever Power lamp Fixing knob (used to stop movements during removal) Power switch Power cable Adjusting knob Forehead rest Measuring window Measuring nozzle Height ...

  • Topcon COMPUTERIZED TONOMETER - page 10

    CONTROL PANEL COMPONENTS Print sw itch ................... Prints out t he screen readings. When there is no reading, holding the switch down feeds the paper. Range sw itch ................ Switches the range between 0-30 and 0-60. Clear sw itch .................. Deletes a ll the measurement values from the screen. Menu sw itch .................. ...

  • Topcon COMPUTERIZED TONOMETER - page 11

    MONITOR SCREEN COMPONENTS Measurement Screen (Auto mode, alignment) Measurement Screen (Manual mode, alignment OK) Menu Screen 10 COMPONENTS Inner alignment mark Outer alignment mark Alignment bar Alignment dot Measuring range Measurement mode Target eye Inner alignment mark (alignment OK) Outer alignment mark Cursor ...

  • Topcon COMPUTERIZED TONOMETER - page 12

    CONTENTS OF PRINTER OUTPUT 11 COMPONENTS Average eye pressure values Time/Date display Work ID No. Message column Measured eye pressure values ID No. Equipment No. Bar code ...

  • Topcon COMPUTERIZED TONOMETER - page 13

    STANDARD ACCESSORIES The following are the standard accessories. The figures in parentheses are the quantities. Please check to see that all accessories are contained. Power cable (1) Rail cover (2) Printing paper (2) Chinrest pin (2) Chinrest pad (1) Silicone cloth (1) Fuse (2) * Different by destinations Dust cover (1) Cleaning kit (1) Instructio ...

  • Topcon COMPUTERIZED TONOMETER - page 14

    PREPARATIONS HOW TO INSTALL THE INSTRUMENT 1 Fasten the clamping knob. 2 Hold the instrument body firmly at the specified positions and place it on the auto- matic instrument table. For the automatic instrument table, see “OPTIONAL ACCESSORIES” on page 46. 3 After installing the instrument, loosen the fixing knob. Now the body components can be ...

  • Topcon COMPUTERIZED TONOMETER - page 15

    HOW TO CONNECT THE POWER CABLE 1 Make sure the POWER SWITCH is OFF. 2 Attach the power cable to the machine body. 3 Plug the power cable into the 3- pin AC receptacle with grounding. HOW TO CONNECT EXTERNAL I/O TERMINALS RS-232C OUT This machine can be connected to another dev ice, including a personal computer via the RS-232C OUT terminal. 1 Conne ...

  • Topcon COMPUTERIZED TONOMETER - page 16

    INITIAL SETTINGS During the initial setting, date, time, operati ng time of the power save function, RS- 232C, mode of average value, buzzer and message can be set. Preparations 1 Make sure the power cable is connected. For connection, see “HOW TO CONNECT THE POWER CABLE” on page 14. 2 Check the no-patient condition of the instrument and turn t ...

  • Topcon COMPUTERIZED TONOMETER - page 17

    Time/Date Setting Example of operation: Illustrations show time setting. 1 Press on the control panel to get the Menu screen. 2 Press , on the control panel, move the cursor to “DATE/TIME SET” and press MEASUREMENT SWITCH . The Date/Time setting screen is displayed. 3 Make sure that the display “BATTERY → O.K.” appears. 4 Press , on the c ...

  • Topcon COMPUTERIZED TONOMETER - page 18

    5 Press , of the control panel, renew figures and press MEASUREMENT SWITCH . The renewed figures are inputted. 6 Press , of the control panel, move t he cursor to “EXIT” and press MEASUREMENT SWITCH . Setting The Pow er Save Time A time for the power save function to achv ale can be selected from 10, 20, 30 or 60min. For shipment, 10min. is set ...

  • Topcon COMPUTERIZED TONOMETER - page 19

    4 Press MEASUREMENT SWITCH . The Menu screen is displayed. RS-232C INPUT/OUTPUT Settings For shipment, settings are EQUIPMENT (Equipment No.) No.1, FORMAT (communi- cation mode) OFF, and SPEED (communication speed) 2400 Example: Setting the equipment No. 1 Return to the Menu screen. 2 Press , of the control panel, move the cu rsor to “RS-232C MOD ...

  • Topcon COMPUTERIZED TONOMETER - page 20

    3 Press , on the control panel, move the cursor to “EQUIPMENT” and press MEASUREMENT SWITCH . 4 Press , on the control panel, change the equipment No. and press MEASUREMENT SWITCH . 5 Press , on the control panel, move the cursor to “EXIT” and press MEASUREMENT SWITCH . The Menu screen returns. 19 PREPARATIONS “EQUIPMENT” and “WORK ID ...

  • Topcon COMPUTERIZED TONOMETER - page 21

    Setting The Average Value Mode The average value display of the measurement values can be selected from integer and decimal displays. For shipment, the integer display is set. 1 Return to the Menu screen. 2 Press , on the control panel, move the cursor to “AVERAGE MODE” and press MEASUREMENT SWITCH . The Average Value Mode screen is displayed. ...

  • Topcon COMPUTERIZED TONOMETER - page 22

    4 Press MEASUREMENT SWITCH . The Menu screen returns. Setting The Buzzer The buzzer can be turned ON/OFF by pressing the switches on the control panel. 1 Return to the Menu screen. 2 Press , on the control panel, move the cursor to “BUZZER SET” and press MEASUREMENT SWITCH . The Buzzer Setting screen is displayed. 3 Press , on the control panel ...

  • Topcon COMPUTERIZED TONOMETER - page 23

    4 Press MEASUREMENT SWITCH . The Menu screen returns. Message Input You can add a brief message to the printout. 1 Return to the Menu screen. 2 Press , on the control panel, move the cursor to “MESSAGE INPUT” and press MEASUREMENT SWITCH . The Message Input screen is displayed. 3 Press , , , on the control panel to move the blinking icon to a c ...

  • Topcon COMPUTERIZED TONOMETER - page 24

    4 Press MEASUREMENT SWITCH . The character selected by the blinking icon is inputted. 5 Press , , , on the control panel, move the blinking icon in the selection column to “EXIT” and press MEASUREMENT SWITCH . The Menu screen is displayed. HOW TO SET PRINTER PAPER Auto Setting 1 Press the printer cover with your thumb, slide it aside and remove ...

  • Topcon COMPUTERIZED TONOMETER - page 25

    2 Slide the paper roll onto the paper shaft, paying attention to the direction of unwind- ing, and pull out the top of the paper 7-8cm. 3 Insert the paper straight into the printer along the paper guide. 4 When the top of the paper stops inside the printer, press to further insert the paper into the printer. Paper feeding starts when the top of t h ...

  • Topcon COMPUTERIZED TONOMETER - page 26

    7 Return the paper retainer lever back to its original position. 8 Reset the printer cover, holdi ng the top of the paper outside. 25 PREPARATIONS The paper is not fed unless the paper retainer lever is lowered. Use the following 58mm wide printer paper: TF50KS-E2C Using another paper may cause a pr inting noise or thin prints. ...

  • Topcon COMPUTERIZED TONOMETER - page 27

    Manual Setting 1 Press the printer cover with your thumb, slide it aside and remove. 2 Slide the paper roll onto the paper shaft, paying attention to the direction of unwind- ing, and pull out the top of the paper 7 ∼ 8cm. 3 Turn the paper retainer lever in the arrow direction. 4 Cut the paper on the control lever side at about 2cm. 26 PREPARATIO ...

  • Topcon COMPUTERIZED TONOMETER - page 28

    5 Insert the paper straight into the printer along the paper guide. 6 Further insert the paper and draw out the top of the paper from the outlet. 7 Adjust the paper so that it comes out st raight from the outlet, and then lower the pa- per retainer lever. 27 PREPARATIONS The paper does not easily pass through the printer unless it is cut on the con ...

  • Topcon COMPUTERIZED TONOMETER - page 29

    8 Set the printer cover, holding the top of the paper outside. HOW TO RESET FROM POWER SAVE STATUS This machine employs a power save function. If the machine is not used during a set time, the power save function stops supplying power to the monitor and CCD camera. Under the power save status, the POWER lamp of the control panel flashes. 1 Press ME ...

  • Topcon COMPUTERIZED TONOMETER - page 30

    BASIC OPERATIONS PREPARATIONS BEFORE MEASUREMENT Turn ON the Pow er 1 Make sure the power cable is connected. For connection, see “HOW TO CONNECT THE POWER CABLE” on page 14. 2 Make sure the instrument is in the no-patient condition and turn ON the POWER SWITCH . 3 The Title screen is displayed, and then the Measurement screen is displayed. Air ...

  • Topcon COMPUTERIZED TONOMETER - page 31

    Setting the Patient 1 Return to the Measurement screen. 2 Ask the patient to sit in front of the instrument. 3 Adjust the automatic instrument table or t he chair for height so that the patient can put his or her chin on the chinrest in a comfortable position. 4 The patient places his or her chin on t he chinrest and stops his or her forehead at th ...

  • Topcon COMPUTERIZED TONOMETER - page 32

    5 Adjust the height of the chinrest, by operat ing the chinrest handle, so that the tail of the patient's eye becomes level with the height mark of the chinrest post. Setting the Safety Stopper 1 Hold the control lever and pull the machine body towards the operator. 2 Turn the control lever and adjust the height of the measuring nozzle to the ...

  • Topcon COMPUTERIZED TONOMETER - page 33

    4 When the measuring nozzle reaches a position 8 ∼ 10mm from the cornea, release the safety stopper knob. 5 Holding the control lever, try to slightly push out the machine body to make sure the stopper is working. If the machine body does not move forwar d any further, the setting is completed. 32 BASIC OPERATIONS 8 ∼ 10mm ...

  • Topcon COMPUTERIZED TONOMETER - page 34

    MEASUREMENT UNDER AUTO MODE Setting the Measurement Mode The initial status of the measurement mode is AUTO, upon turning the power ON. 1 Return to the Measurement screen. 2 Press on the control panel and change the measurement mode display to AUTO. Setting the Measuring Range In this machine, the measuring range can be switched between 0-30 and 0- ...

  • Topcon COMPUTERIZED TONOMETER - page 35

    Alignment and Measurement The alignment operation can be performed with the control lever. • To move the measuring head vertically, turn the control lever right for raising and left for lowering. 34 BASIC OPERATIONS It is recommended that you do intraocular pressure measure- ments several times. Since the intraocular pressure varies by heart beat ...

  • Topcon COMPUTERIZED TONOMETER - page 36

    1 Hold the control lever and pull the machine body towards the operator. 2 Move the control lever in directions as needed and bring the patient’s eye to the center of the monitor screen. 3 Tell the patient to gaze at the yellow-green light. 4 Move the machine body toward the pati ent and focus the target eye. A vague alignment dot becomes seen re ...

  • Topcon COMPUTERIZED TONOMETER - page 37

    5 Move the machine body in directions as needed in order to get the alignment dot within the inner alignment mark on the monitor screen. 6 Holding the alignment dot within the inner alignment mark, slightly push the machine body toward the patient. When the machine body approaches the tar get eye, the alignment bar and “FOR- WARD” display appea ...

  • Topcon COMPUTERIZED TONOMETER - page 38

    7 After the alignment bar is displayed, push the machine body out a little bit more. When the alignment is adjusted, measur ement is done automatically and the meas- urement value is displayed on the monitor screen. 37 BASIC OPERATIONS When the outer alignment mark is not di splayed, measurement is not possible. Measurement can be done when the out ...

  • Topcon COMPUTERIZED TONOMETER - page 39

    Display of Measurement Values Measurement values are displayed on the monitor screen for up to three measure- ments. From the fourth measurement on, values of earlier measurements are deleted in order. Figure only : Correct measurement Figure in ( ) : Low in reliability ERR : Incorrect measurement OVER : Measurement value exceeding the measuring ra ...

  • Topcon COMPUTERIZED TONOMETER - page 40

    1 Hold the control lever and pull the machine body towards the operator. 2 Move the control lever in directions as needed in order to bring the patient’s ey e to the center of the monitor screen. 3 Tell the patient to gaze at the yellow-green light. 4 Move the machine body toward the patient and focus the target eye. A vague alignment dot becomes ...

  • Topcon COMPUTERIZED TONOMETER - page 41

    6 Holding the alignment dot within the inner alignment mark, slightly push the machine body toward the patient. When the machine body approaches the tar get eye, the alignment bar and the “FORWARD” display appear on the monitor screen. 7 Move the machine body back and forth, with the alignment bar as a reference, while holding the alignment dot ...

  • Topcon COMPUTERIZED TONOMETER - page 42

    DELETING MEASUREMENT VALUES 1 Press on the control panel. All the measurement values of the right and left eyes are deleted and the instrument settings return to their status upon turning the power ON. 41 BASIC OPERATIONS ...

  • Topcon COMPUTERIZED TONOMETER - page 43

    INDIVIDUAL OPERATIONS HOW TO PRINT OUT MEASUREMENT VALUES This machine can print out measurement values with the built-in printer. 1 Return to the Measurement screen. 2 Press on the control panel. Measurement values of the monitor screen are printed out. Upon printing, the measured values ar e deleted automatically from the screen. 42 INDIVIDUAL OP ...

  • Topcon COMPUTERIZED TONOMETER - page 44

    3 Hold the paper and pull it diagonally to cut. HOW TO CORRECT MEASUREMENT VALUES Though the machine is adjusted for displayi ng optimal measurement values, the values can be corrected within a -4 ∼ +3mmHg range. 1 Make sure the power is OFF. 2 Open the control panel lid. 3 Using a screwdriver, turn the “ ” of the select switch. Settings: 0: ...

  • Topcon COMPUTERIZED TONOMETER - page 45

    INPUT/OUTPUT VIA RS-232C Output via RS-232C This machine can output data via the RS- 232C interface to a personal computer or similar device. 1 Make sure the RS-232C OUT is connected. For connection, see “HOW TO CONNECT EXTERNAL I/O TERMINALS” on page 14. 2 Check the settings for data communication. For data communication, see “RS-232C Input/ ...

  • Topcon COMPUTERIZED TONOMETER - page 46

    BEFORE REQUESTING SERVICE CHECKING OPERATIONS Air Check If a problem is suspected, do an air check. If the result is “NG (+)” or “NG (-),” call your dealer. For instructions on how to perform an air check, see “Air Check” on page 29. Checking Operations If a problem is suspected, perform checks following the Check List shown below. If t ...

  • Topcon COMPUTERIZED TONOMETER - page 47

    REFERENCE OPTIONAL ACCESSORIES Automatic instrument table AIT-20 and Table Board Driven by electric power, it can change the hei ght of the instrument as desired so as to enable the patient to undergo measurem ent in a comfortable position. Size ............................... 586(W) × 520(D)mm Table height .................. 675-865mm (differs by ...

  • Topcon COMPUTERIZED TONOMETER - page 48

    RS-232C COMMUNICATION SPECIFICATIONS Connector Types Input terminal: DIN 8-pin (TSC0838-01-2051, Hoshiden) Output terminal: DSUB 9-pin (DE-9S-N, JAE) I/O Terminal Pin Arrangement ⋅ Output terminal: DSUB 9-pin (Pin Nos.1 and 9 are not used.) Pin No. Code Description I/O 2 RD (RXD) Data receiving I 3 SD (TXD) Data transmission O 4 ER (DTR) Data ter ...

  • Topcon COMPUTERIZED TONOMETER - page 49

    Transmission Formula Mode 1, 2, 3 Synchronization Non-synchronous Communication speed 2400/9600 bps Start bit 1 bit Stop bit 2 bit Data length 8 bit Parity None Operating code ASCI code Mode 4, STD1 mode Synchronization Non-synchronous Communication speed 2400/9600 bps Start bit 1 bit Stop bit 1 bit Data length 8 bit Parity None Operating code ASCI ...

  • Topcon COMPUTERIZED TONOMETER - page 50

    Communication format Mode 2: Model name, Type No. 10 byte Time/Date 19 byte Measurement value (right or left eye) average data 9 byte ∗ If ERRs only, transmission is not done. (Example) Communication format Mode 4, STD 1: • Data Transmission Model name, Type No. 15 byte Machine No. 2 byte ROM version 10 byte ID No. 13 byte Work ID No. 13 byte M ...

  • Topcon COMPUTERIZED TONOMETER - page 51

    • Data Receiving Patient ID data 13 byte (Example) Setting RS-232C Communication Conditions In the Menu screen, move the cursor using the , keys on the control panel, and press MEASUREMENT SWITCH . Further, move the cursor to an item to be changed on the screen shown below, and press MEASUREMENT SWITCH . [ S E T →∗∗∗∗ ] is displayed at ...

  • Topcon COMPUTERIZED TONOMETER - page 52

    ⋅ Communication format Format: OFF, MODE 1, MODE 2, MODE 3, MODE 4, (FORMAT) STD 1 (For shipment, “OFF” is set.) MODE 1: When is pressed, communication is done after printing. MODE 2: Data communication is done every measure- ment. MODE 3: When is pressed, communication is done without printing. MODE 4: When is pressed, communication is done ...

  • Topcon COMPUTERIZED TONOMETER - page 53

    MAINTENANCE AND CHECKING ACCURACY MAINTENANCE Cleaning the Measuring Window Glass • To secure auto alignment and correct m easurement values, clean the measuring window glass after each day’s work. • Clean the glass when “CLEAN THE MEASURING WINDOW GLASS” is displayed on the monitor screen. 1 Prepare the ethanol. 2 Using a blower, remove ...

  • Topcon COMPUTERIZED TONOMETER - page 54

    Cleaning the Window Glass inside the Nozzle • When the window glass inside the nozzle becom es stained, it makes the fixation tar- get unclear, causing errors in auto alignm ent and measurement values. If the fixa- tion target is unclear or measurement values with parentheses are frequent, clean the window glass inside the nozzle. • Clean the g ...

  • Topcon COMPUTERIZED TONOMETER - page 55

    Daily Maintenance • This machine must be kept free of dus t; apply the measuring window cap and dust cover when not in use. • When not in use, turn the POWER SWITCH OFF. Ordering Consumable Supplies • When placing an order for consumable supp lies, tell your dealer the product name, part code and quantity. Name Code Chinrest pad 40310 4082 Si ...

  • Topcon COMPUTERIZED TONOMETER - page 56

    Paper Jam in Printer • Remove the printer cover, release the paper retainer lever and remove the jammed paper. Replacing the Fuse 1 Make sure the power is OFF and the power cables are unplugged. 2 Press the fuse holder with a screwdriver and turn it counterclockwise. The fuse holder can be taken out. 55 MAINTENANCE AND CHECKING • If paper is ja ...

  • Topcon COMPUTERIZED TONOMETER - page 57

    3 Replace the fuse with the attached fuse. 4 Press the fuse holder with a screwdriver and turn it clockwise. The fuse holder is now reset. SPECIAL NOTES ON CLEANING Cleaning the Outer Cover • When the outer cover, operation panel and the like become stained, clean them with a dry cloth. If the stain is extreme, a neutral detergent for tableware m ...

  • Topcon COMPUTERIZED TONOMETER - page 58

    When calling please give us the following infor- mation about your unit: ⋅ Machine type: CT-80 ⋅ Manufacturing No. (Shown on the rating plate on the right side of the base.) ⋅ Period of Usage (Please gi ve us the date of pur- chase). ⋅ Description of Problem (as detailed as possible). COMPUTERIZED TONOMETER (CT-80) INSTRUCTION MANUAL Versio ...

  • Topcon COMPUTERIZED TONOMETER - page 59

    COMPUTERIZED TONOMETER CT - 80 TO P C ON AM E R I CA C O RP O R ATI O N CORPORATE OFFICE :37 West Century Road, Paramus, New Jersey 07652, U.S.A. Phone: 201-261-9450 Fax : 201-387-2710 www .topcon.com TOPCON CANA DA INC. 110 Provencher Avenue, Boi sbriand, QC J7G 1N1 CANAD A Phone: 514-430-7771 Fax: 514-430-6457 TOPCON OMNI SYSTEMS, INC. Valley For ...

Fabricant Topcon Catégorie Multi-tool

Les documents que nous recevons du fabricant de l'appareilTopcon COMPUTERIZED TONOMETER peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Topcon
- manuels d’utilisations COMPUTERIZED TONOMETER
- fiches produit Topcon
- dépliants
- ou étiquettes-énergie Topcon COMPUTERIZED TONOMETER
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Topcon COMPUTERIZED TONOMETER.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Topcon COMPUTERIZED TONOMETER, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Topcon COMPUTERIZED TONOMETER. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Topcon COMPUTERIZED TONOMETER.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Topcon COMPUTERIZED TONOMETER, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Topcon COMPUTERIZED TONOMETER par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Topcon COMPUTERIZED TONOMETER.

Le manuel d’utilisation complet Topcon, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Topcon COMPUTERIZED TONOMETER - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Topcon COMPUTERIZED TONOMETER, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lTopcon COMPUTERIZED TONOMETER qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Topcon COMPUTERIZED TONOMETER - qui devraient nous aider dans les premières étapes lors de l'utilisation Topcon COMPUTERIZED TONOMETER
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Topcon COMPUTERIZED TONOMETER
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Topcon COMPUTERIZED TONOMETER dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Topcon COMPUTERIZED TONOMETER?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Topcon COMPUTERIZED TONOMETER, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Topcon COMPUTERIZED TONOMETER il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)