Manuel d’utilisation A&D UA-767 Plus BT

14 pages 0.86 mb
Télécharger

Aller à la page of 14

Summary
  • A&D UA-767 Plus BT - page 1

    D igi tal B lood Pressure M oni tor Model UA-767 BT Instruction Manual 1WMPD4001357A ...

  • A&D UA-767 Plus BT - page 2

    ...

  • A&D UA-767 Plus BT - page 3

    English 1 Contents Dear Customers .................................................................... 2 Preliminary Remarks ............................................................. 2 Precautions ........................................................................... 2 Parts Identification .................................................. ...

  • A&D UA-767 Plus BT - page 4

    English 2 Dear Customers Congratulations on purchasing a st ate-of-the-art A&D blood pressure monitor, one of the most advanced m onitors available today. Designed for ease of use and accuracy, this m onitor will facilitat e your daily blood pressure regimen. We recommend that you read thro ugh this manual carefully before using the device for ...

  • A&D UA-767 Plus BT - page 5

    English 3 Part s Identification Battery Cover 1.5V Batteries (R6P or AA) Battery Compartment Part of Display Pressure Bar Indicator MEMORY Systolic Pressure Diastolic Pressure Pulse Rate Battery Indicator I . H . B . In d ic at o r (Irregular heartbeat indicator) Heart Mark Display Air Connector Plug Air Socket Arm Cuff DC Jack START Button Air Hos ...

  • A&D UA-767 Plus BT - page 6

    English 4 Symbols Symbols Function / Meaning Recommended Action Standby and power on. Battery installation guide Direct current SN Serial number Date of manufacture Type BF: Device, cuff and tubing are designed to provide special protection against electrical shocks. The indicator that appears while measurement is in progress. It blinks when the pu ...

  • A&D UA-767 Plus BT - page 7

    English 5 Using The Monitor Inst alling / Changing The Batteries 1. Slide the battery cover up to open it. 2. Remove the used batteries and insert new batteries into the battery compartment as show n, taking care that the polarities (+) and (-) are correct. 3. Slide the battery cover down to close. Use only R6P, AA batteries. CAUTION Insert the bat ...

  • A&D UA-767 Plus BT - page 8

    English 6 Using The Monitor Att aching The Arm Cuff 1. Wrap the cuff around the upper arm, about 2 - 3 cm above the elbow, as shown. Place the cuff directly against the skin, as clothing may cause a faint pulse, and result in a measurement error. 2. Constriction of the upper arm, caused by rolling up a shirtsleeve, may prevent accurate readings. 3. ...

  • A&D UA-767 Plus BT - page 9

    English 7 Measurement s Model UA-767 BT is designed to detect th e pulse and to inflate the cuff to a systolic pressure level automatically. If your systolic pressure is expec ted to exceed 230 mmHg or you use the optional small cuff, read "Measurem ent with the desired systolic pressure" on the next page. Normal Measurement 1. Place the ...

  • A&D UA-767 Plus BT - page 10

    English 8 Measurements Measurement With The Desired Systolic Pressure If your systolic pressure is expect ed to exceed 230 mmHg or you use the optional small cuff, use this procedure. 1 . P l a c e t h e c u ff o n th e arm (preferably the left arm). 2. Press and hold the START button until a number about 30 to 40 mmHg higher than your expected sys ...

  • A&D UA-767 Plus BT - page 11

    English 9 What Is An Irregular Heartbeat Model UA-767 BT blood pressure monitor provides a blood pressure and pulse rate measurement ev en when an irregular heartbeat occurs. An irregular heart beat is defined as a heart beat that varies by 25% from the average of all heart beats during the blood pressure measurement. It is important that you be re ...

  • A&D UA-767 Plus BT - page 12

    English 10 Reference Material: Journal of Hyperte nsion 1999, Vol 17 No.2 mmHg 110 105 100 95 90 85 80 Optimal 120 130 140 150 160 170 180 Systolic blood pressure mmHg Normal High-normal Grade 1 hypertension (mild ) Grade 2 hypertension (mode rate) Grade 3 hypertension (severe) Diastolic blood pressure About Blood Pressure What Is Blood Pressure? B ...

  • A&D UA-767 Plus BT - page 13

    English 11 Typical fluctuation within a day (Measured every five minutes) PM AM Time Diastolic blood pressure Systolic Diastolic Sleep described in this manual to get to know your normal blood pressure. R egular readings give a more comprehensive bl ood pressure history. Be sure to note date and time when recording your blood pressure. Consult your ...

  • A&D UA-767 Plus BT - page 14

    English 12 Maintenance Do not open the device. It uses delicate electrical components and an intricate air unit that could be da maged. If you cannot fix the problem using the troubleshooting instructi ons, request service from your dealer or from the A&D service group. The A&D service group will provide technical information, spare part s ...

Fabricant A&D Catégorie Blood Pressure Monitor

Les documents que nous recevons du fabricant de l'appareilA&D UA-767 Plus BT peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques A&D
- manuels d’utilisations UA-767 Plus BT
- fiches produit A&D
- dépliants
- ou étiquettes-énergie A&D UA-767 Plus BT
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation A&D UA-767 Plus BT.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation A&D UA-767 Plus BT, manuels d’entretien, brefs manuels ou manuels de l’utilisateur A&D UA-767 Plus BT. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit A&D UA-767 Plus BT.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil A&D UA-767 Plus BT, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser A&D UA-767 Plus BT par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs A&D UA-767 Plus BT.

Le manuel d’utilisation complet A&D, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel A&D UA-767 Plus BT - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières A&D UA-767 Plus BT, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lA&D UA-767 Plus BT qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil A&D UA-767 Plus BT - qui devraient nous aider dans les premières étapes lors de l'utilisation A&D UA-767 Plus BT
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de A&D UA-767 Plus BT
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service A&D UA-767 Plus BT dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de A&D UA-767 Plus BT?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec A&D UA-767 Plus BT, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec A&D UA-767 Plus BT il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)