    V1.0 SM202 00 104 26 EXCEL L PRECISION CO., L T D. DIGI T A L HIGH PRECISION WEIG H ING S CALES USER INSTRUCT I ONS © E x cell Precision L i mited 2004. All rights reser v ed W orld w ide. T he information c ontained herein is the propert y o f E x cell Precision L i mited and i s supplied w ithout liabilit y f or errors or omissions. No part ma y ...

  • Excell Precision DIGITAL HIGH PRECISION WEIGHING SCALES - page 2

    ...

  • Excell Precision DIGITAL HIGH PRECISION WEIGHING SCALES - page 3

    V1.0 SM20 2 00 1 0426 1 EXCEL L PRECISION CO., L T D. T ABLE OF CONTENTS BEFORE USING THE SC A L E .................................................................................................... .3 PRE P A RING T O USE THE SC A L E ............................................................................................ .3 INTRODUCTIO N ... ...

  • Excell Precision DIGITAL HIGH PRECISION WEIGHING SCALES - page 4

    V1.0 SM20 2 00 1 0426 2 EXCEL L PRECISION CO., L T D. 2. REL AY OU T P U T ................................................................................................................ . 23 (1) Relay Outpu t ................................................................................................................. . 23 (2) Relay Pin Descri ...

  • Excell Precision DIGITAL HIGH PRECISION WEIGHING SCALES - page 5

    V1.0 SM20 2 00 1 0426 3 EXCEL L PRECISION CO., L T D. BEFORE USING THE SCALE T o enab l e y o u to u s e this sc a le co r rect l y , w e sugg e st tha t y ou re ad this manu a l ca r ef u l l y . 1. Do not use scale i n areas w ith e x cessi v e w ater and don ’ t spra y the s cale or indicator w ith w ater w hen cleaning. Remo v e all w ater f ...

  • Excell Precision DIGITAL HIGH PRECISION WEIGHING SCALES - page 6

    V1.0 SM20 2 00 1 0426 4 EXCEL L PRECISION CO., L T D. INTRODUCTION 1. F E A T URES 1 . D u al - w eighing uni t s: Kilogram (kg) and pound (lb). 2. Multi-function operation: Full range tare; P r e-tare; Hold funct i on; Net / Gross w eight displa y ; Simp l e counting; Preset w eight v alue and quantit y v alue; Ad j ustable noise f ilter setting f ...

  • Excell Precision DIGITAL HIGH PRECISION WEIGHING SCALES - page 7

    V1.0 SM20 2 00 1 0426 5 EXCEL L PRECISION CO., L T D. 2. SPECIFI C A TIONS The a v ailable ca p acities for selection a r e different and depend on v arious models: Capacit y D i v ision 3 kg (6 lb) 0.2 g (0.0005 lb) 6 kg (12 lb) 0.2 g (0.0005 lb) 7.5 kg (15 lb) 0.5 g (0.001 lb) 15 kg ( 30 lb) 1 g (0.002 lb) 30 kg ( 60 lb) 2 g (0.005 lb) 75 kg ( 60 ...

  • Excell Precision DIGITAL HIGH PRECISION WEIGHING SCALES - page 8

    V1.0 SM20 2 00 1 0426 6 EXCEL L PRECISION CO., L T D. . . . . . . . . . . P cs LCD DISPL A Y SYMBOLS HIGH : Preset High Limit W eight V alue OK : The r ange bet w een Lo w & High Limit Weight V alue LOW : Preset Lo w Limit W eight V alue kg : “ kg ” unit lb : “ lb ” unit Pcs : “ COUN T I NG ” mode indicating the number o f pieces à ...

  • Excell Precision DIGITAL HIGH PRECISION WEIGHING SCALES - page 9

    V1.0 SM20 2 00 1 0426 7 EXCEL L PRECISION CO., L T D. . . . . . . . . . . PT → 0 ← T R ^ / Pcs Pcs KEYBOARD FUNCTION 1. : Units Ke y to c hoo s e the desired unit w eig h t (kg or lb). 2. : Preset High & Lo w Limit v alue. 3. : ∧ ⇒ Data Entr y Ke y , ⇒ Backlight Ke y . 4. : ⇒ Print Ke y to print the total da t a ; ↵ ⇒ Con f i r ...

  • Excell Precision DIGITAL HIGH PRECISION WEIGHING SCALES - page 10

    V1.0 SM20 2 00 1 0426 8 EXCEL L PRECISION CO., L T D. ^ / OPER A TION 1. DISP L A Y B A CKLIGHT Press the k e y to choose the desi r ed di s pla y backlight mode: . ⇒ “ Auto Ba c klight ” mode. W hen the w eight is o v er 10 d iv isions or an y ke y is pressed, the di s pla y backlight w ill be s w itched on. W hen the w eight returns to z er ...

  • Excell Precision DIGITAL HIGH PRECISION WEIGHING SCALES - page 11

    V1.0 SM20 2 00 1 0426 9 EXCEL L PRECISION CO., L T D. I. W eight T otalising v T he totalising f unction can be u s ed up to a ma x imum o f 9999 times be f ore it must be re s et. T he totalising disp l a y is limited to 6 digits ma x imum. II. Recall T otalised W ei g ht V alues 1. Press the k e y to displa y the total number of addition s and th ...

  • Excell Precision DIGITAL HIGH PRECISION WEIGHING SCALES - page 12

    V1.0 SM20 2 00 1 0426 10 EXCEL L PRECISION CO., L T D. (3). Deduction of t he Con t ainer W ei g ht I. The weight of the c o ntainer is unknown ( T are ) II. Recall the semi-auto tare value Press the k e y f ollo w ed b y pressing the ke y ⇒ T he disp l a y sho w s the tare w eight v alue. III. Clear the semi-auto t are W hen the c ontainer is re ...

  • Excell Precision DIGITAL HIGH PRECISION WEIGHING SCALES - page 13

    V1.0 SM20 2 00 1 0426 11 EXCEL L PRECISION CO., L T D. PT IV. The weight of the c o ntainer is known (P r e-set tare) V. Recall the pre-set ta r e value Press the k e y f ollo w ed b y pressing the ke y ⇒ T he disp l a y sho w s the pre-set tare v alue. VI. Clear the p r e-set ta r e value Press the k e y f ollo w ed b y pressing the ke y , then ...

  • Excell Precision DIGITAL HIGH PRECISION WEIGHING SCALES - page 14

    V1.0 SM20 2 00 1 0426 12 EXCEL L PRECISION CO., L T D. ^ / (4). Check W e ighing Press the k e y to enter the check w eighing f unction. Press the k e y to return back to the w eighing mode. I. Pre-set the “ Low limit value ” , “ High limit value ” , and “ the buzzer ” operation Press the k e y to enter the v alue required and step to t ...

  • Excell Precision DIGITAL HIGH PRECISION WEIGHING SCALES - page 15

    V1.0 SM20 2 00 1 0426 13 EXCEL L PRECISION CO., L T D. II. Pre-set the Low limit value only After c ompleting the Lo w limit v alue setting, the di s pla y sho ws . . Press the ke y to complete the s etting, and the disp l a y sho w s v W hen u s ers onl y pre- s et the Lo w limit v alue, the bu zz er setting is f i x ed at: III. High/OK/Low indica ...

  • Excell Precision DIGITAL HIGH PRECISION WEIGHING SCALES - page 16

    V1.0 SM20 2 00 1 0426 14 EXCEL L PRECISION CO., L T D. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4. COUNTING FUNCTION Press the k e y to enter the counting f unction. Press the ke y to return back to the w eighing mode. (1). Sampling NOTE: v T he larger the sample si z e, the more accurate the unit w eight. (The min i mum s ample ...

  • Excell Precision DIGITAL HIGH PRECISION WEIGHING SCALES - page 17

    V1.0 SM20 2 00 1 0426 15 EXCEL L PRECISION CO., L T D. CONFIGUR A TION SETTINGS S w itch on the scale. W h i le the s c ale is c ounting back w ard to z ero, press and hold the ke y until the displa y sho w s the soft w are program v ersion number: “ ” . Release the ke y , the s c ale enters the con f iguration sett i ng mode. is displa y ed. P ...

  • Excell Precision DIGITAL HIGH PRECISION WEIGHING SCALES - page 18

    V1.0 SM20 2 00 1 0426 16 EXCEL L PRECISION CO., L T D. ^ / 1. CHECK-W E IGHING CONFIGU R A TION ♦ F8 (Hold) a f f e c ts access to F 4. I f F 8 is s et, ac c ess to F4 is den i ed. Press the o r ke y to select the F4 function ⇒ the displa y sho w s T Press the ↵ ke y to enter the check w eighing con f iguration Press the ∧ ke y to enter the ...

  • Excell Precision DIGITAL HIGH PRECISION WEIGHING SCALES - page 19

    V1.0 SM20 2 00 1 0426 17 EXCEL L PRECISION CO., L T D. ^ / 2. RS-232 SE T TING ♦ J1 and J3 on the R S-232 i nte r f a c e a r e connected together (sho r t), w hen the RS-232 inte r f ace is connected to a c ompute r . ♦ J2 and J4 on the R S-232 i nte r f a c e arte connected together (sho r t), w hen the RS-232 inte r f ace is connected to a p ...

  • Excell Precision DIGITAL HIGH PRECISION WEIGHING SCALES - page 20

    V1.0 SM20 2 00 1 0426 18 EXCEL L PRECISION CO., L T D. ^ / 3. EXIT CONFIGU R A TION S ETTINGS Press the o r ke y to select the F6 function ⇒ the displa y sho w s Press the ↵ ke y Scale re v erts back to the w eighing mode T A CTION DISPL A Y ...

  • Excell Precision DIGITAL HIGH PRECISION WEIGHING SCALES - page 21

    V1.0 SM20 2 00 1 0426 19 EXCEL L PRECISION CO., L T D. RS-232 AND REL A Y OUTPUT 1. RS-232 OR SERIA L PRINTER OUTPUT (1) RS-23 2 (2 5 P in ‘ D ’ t y pe) Pin Des c rip t ion ˙ J1 - J3 SHO R T ; J 2 - J4 OPEN (de f ault sett i ng) Pin 2 ⇒ RXD Pin 3 ⇒ T XD Pin 7 ⇒ GND ˙ J2 - J4 SHO R T ; J 1 - J2 OPEN Pin 2 ⇒ T XD Pin 3 ⇒ RXD Pin 7 ⇒ ...

  • Excell Precision DIGITAL HIGH PRECISION WEIGHING SCALES - page 22

    V1.0 SM20 2 00 1 0426 20 EXCEL L PRECISION CO., L T D. (3) Da t a Form a t S t able transmission ( ) / Continuous transmission ( ) Press the ↵ ke y t o transmit ( ) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 kg/lb HEAD 1 , HEAD 2 , D A TA UNIT CR LF HEAD 1 ( 2 BY T ES ) HEAD 2 ( 2 BY T ES ) O L - O v erload , Under load T R - T ARE Mode S T - D ...

  • Excell Precision DIGITAL HIGH PRECISION WEIGHING SCALES - page 23

    V1.0 SM20 2 00 1 0426 21 EXCEL L PRECISION CO., L T D. Press the ↵ ke y t o transmit (simple m o de) S/N W T/UNI T ( kg / lb ) - - - - - - - - - - - - - - 0001 1.0000 E Press the ↵ ke y or the M+ key 0002 1.0000 E Press the ↵ ke y or the M+ key 0003 1.0000 E Press the ↵ ke y or the M+ key 0004 1.0000 E Press the ↵ ke y or the M+ key 0005 ...

  • Excell Precision DIGITAL HIGH PRECISION WEIGHING SCALES - page 24

    V1.0 SM20 2 00 1 0426 22 EXCEL L PRECISION CO., L T D. EZ-2 printing mode (Baud rate must be set to 9600). Press the ↵ ke y t o transmit (complete m ode) E Press the ↵ ke y or the M + key E Press the ↵ ke y or the M + ke y E Press the ↵ ke y or t he M + k ey E Press the ↵ ke y t wice t o prin t out t he t o t al < Remarks > : G = GR ...

  • Excell Precision DIGITAL HIGH PRECISION WEIGHING SCALES - page 25

    V1.0 SM20 2 00 1 0426 23 EXCEL L PRECISION CO., L T D. 2. REL A Y OUTPUT (1) Rel a y Output Relay ’ s f unct i on acts as signal output i n the c heck- w eighing mode. W hen an object ’ s w eight v alue reaches one of the setting po i nt s (HI, OK, L O W ) , the re l a y outputs a signal through PIN 1, PIN2, or PIN 3. T o set the check- w eighi ...

  • Excell Precision DIGITAL HIGH PRECISION WEIGHING SCALES - page 26

    V1.0 SM20 2 00 1 0426 24 EXCEL L PRECISION CO., L T D. (4) P o w e r Source Illus t ra t ion T he rela y circuit board can be supplied either b y the e x ternal AC po w er or internal DC po w e r . • Rela y po w ered b y e x ternal AC po w er PIN4 and PIN5 are c onnected w ith AC po w er source; J1 and J2 OPEN ‚ Rela y po w ered b y internal DC ...

Fabricant Excell Precision Catégorie Scale

Les documents que nous recevons du fabricant de l'appareilExcell Precision DIGITAL HIGH PRECISION WEIGHING SCALES peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Excell Precision
- manuels d’utilisations DIGITAL HIGH PRECISION WEIGHING SCALES
- fiches produit Excell Precision
- dépliants
- ou étiquettes-énergie Excell Precision DIGITAL HIGH PRECISION WEIGHING SCALES
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Excell Precision DIGITAL HIGH PRECISION WEIGHING SCALES.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Excell Precision DIGITAL HIGH PRECISION WEIGHING SCALES, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Excell Precision DIGITAL HIGH PRECISION WEIGHING SCALES. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Excell Precision DIGITAL HIGH PRECISION WEIGHING SCALES.

Manuel d’utilisation complet de l’appareil Excell Precision DIGITAL HIGH PRECISION WEIGHING SCALES, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Excell Precision DIGITAL HIGH PRECISION WEIGHING SCALES par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Excell Precision DIGITAL HIGH PRECISION WEIGHING SCALES.

Le manuel d’utilisation complet Excell Precision, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Excell Precision DIGITAL HIGH PRECISION WEIGHING SCALES - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Excell Precision DIGITAL HIGH PRECISION WEIGHING SCALES, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lExcell Precision DIGITAL HIGH PRECISION WEIGHING SCALES qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Excell Precision DIGITAL HIGH PRECISION WEIGHING SCALES - qui devraient nous aider dans les premières étapes lors de l'utilisation Excell Precision DIGITAL HIGH PRECISION WEIGHING SCALES
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Excell Precision DIGITAL HIGH PRECISION WEIGHING SCALES
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Excell Precision DIGITAL HIGH PRECISION WEIGHING SCALES dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Excell Precision DIGITAL HIGH PRECISION WEIGHING SCALES?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Excell Precision DIGITAL HIGH PRECISION WEIGHING SCALES, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Excell Precision DIGITAL HIGH PRECISION WEIGHING SCALES il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)