Manuel d’utilisation Python 400 ESP

24 pages 0.7 mb
Télécharger

Aller à la page of 24

Summary
  • Python 400 ESP - page 1

    © 1999 Directed Electr onics , Inc . Vista, CA N410 10-99 400 ESP Installation Guide ® ...

  • Python 400 ESP - page 2

    2 © 1999 Directed Electr onics , Inc . Vista, CA table o f contents Bitwriter ™ , Code Hopping ™ , DEI ® , Doubleguard ® , ESP ™ , FailSafe ® , Ghost Switch ™ , Learn Routine ™ , Nite- Lite ® , Nuisance Prevention Circuitry ® , NPC ® , Revenger ® , Silent Mode ™ , Soft Chirp ® , Stinger ® , V alet ® , V ehicle Recovery System ...

  • Python 400 ESP - page 3

    © 1999 Directed Electr onics , Inc . Vista, CA 3 what is included ■ The control module (see diagr am) ■ Tw o 471T r emote transmitter s ■ The plug-in status LED ■ The plug-in V alet ® /Progr am switch Primary Harness (H1) Blue V alet ® /Program switch plug Plug-in LED port H2 Door Lock Harness P ort 3-pin Data/Progr am Plug Pre-wir ed Fa ...

  • Python 400 ESP - page 4

    4 © 1999 Directed Electr onics , Inc . Vista, CA installation points to r emember This system has been desi gn ed to provi d e th e ultimate in conveni en ce to both the d ealer an d the en d user . Th e micr opr ocessor at the h eart o f th e system utilizes a sophisticated “Learn Routin e” to pr ogram tr an smitters as well as configur e ope ...

  • Python 400 ESP - page 5

    © 1999 Directed Electr onics , Inc . Vista, CA 5 primary harness (H1), 12-pin connector ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ RED/WHITE (-) 200 mA CHANNEL 2 V ALIDITY OUTPUT RED (+) CONST ANT POWER INPUT BROWN (-) HORN HONK OUTPUT YELLOW (+) SWITCHED IGNITION INPUT BLACK (-) CHASSIS GROUND INPUT VIOLET ...

  • Python 400 ESP - page 6

    6 © 1999 Directed Electr onics , Inc . Vista, CA primary harness (H1) wir e connection guide This wire suppli es a (-) 500 mA gr ound as lon g as th e system is arm ed. This output ceases as soon as th e system is disarmed . Th e oran g e wir e is pre-wir ed to con trol th e DEI ® 8618 starter kill r elay . NOTE: If connecting the orange wire to ...

  • Python 400 ESP - page 7

    © 1999 Directed Electr onics , Inc . Vista, CA 7 IMPORT ANT! Never use this wire to drive anything but a relay or a low-current input! The transis- torized output can only provide 200 mA of current, and connecting directly to a solenoid, motor , or other high-current device will cause it to fail. Connect this wir e to th e option al d om eligh t s ...

  • Python 400 ESP - page 8

    8 © 1999 Directed Electr onics , Inc . Vista, CA Type A (+) polarity s ystem: Wir e relays as sh own. Type B (-) polarity s ystem: Connect th e BLUE H1/6 wir e to the unlock wir e in th e vehicle an d wire th e r elay as shown. ...

  • Python 400 ESP - page 9

    © 1999 Directed Electr onics , Inc . Vista, CA 9 Type C (+) r e versing polarity s ystem: Wir e relays as sh own. Connect this wir e to bar e metal, pr efer ably with a f actory bolt rath er than your own scr ew (screws ten d to eith er strip or loosen with time). W e recomm end gr oun ding all your compon en ts to th e same poin t in th e vehicle ...

  • Python 400 ESP - page 10

    10 © 1999 Directed Electr onics , Inc . Vista, CA Connect this wir e to an i gnition sour ce . This input must show (+)12V with th e k ey in run positi on and d urin g crankin g. M ake sur e that this wir e cann ot be shorted to th e chassis at an y point. This wir e will tri gger th e system if the i gniti on is turned on bef or e th e unit is di ...

  • Python 400 ESP - page 11

    © 1999 Directed Electr onics , Inc . Vista, CA 11 When th e system r eceives the tr an smitter cod e contr ollin g Channel 2 f or lon ger than 1.5 secon ds , th e red/white wire will supply an output as lon g as th e tran smissi on con tinues . This is o ften used to operate a trunk/hatch release or oth er r elay-driven fun cti on s. IMPORT ANT! N ...

  • Python 400 ESP - page 12

    12 © 1999 Directed Electr onics , Inc . Vista, CA harness 2 (H2), (+/-) door lock outputs ______ ______ ______ door lock wiring diagr ams This system can contr ol two comm on power door lock types with out an y ad dition al parts! T o interf ace with som e vehicles or if an actu ator is to be in stalled, you will n eed a 451M Door Lock Relay Satel ...

  • Python 400 ESP - page 13

    © 1999 Directed Electr onics , Inc . Vista, CA 13 IMPORT ANT! Remember that the functions of these wires reverse between Type A and T ype B! This system is common in m an y T oyotas, Nissan s, H on d as and Saturn s , as well as Fords with th e k eyless-entry systems (som e oth er Fords also use T ype B). The switch will have thr ee wir es on it, ...

  • Python 400 ESP - page 14

    14 © 1999 Directed Electr onics , Inc . Vista, CA Interf acin g with a reversin g polarity system r equir es either two r elays or on e 451M (not in clu ded). I t is criti cal to id en tify the pr oper wir es an d locate the m aster switch to in terface pr operly . Locate wires that sh ow voltag e on lock and unlock. Cut on e o f the suspect wir e ...

  • Python 400 ESP - page 15

    © 1999 Directed Electr onics , Inc . Vista, CA 15 In ord er f or this system to contr ol on e or m ore afterm ark et actuators , a 451M or two r elays (option al) ar e n eeded . V ehi cles without f actory power d oor locks r equire th e in stallation o f on e actuator per d oor . This requir es m ount- ing th e d oor lock actuator in si d e the d ...

  • Python 400 ESP - page 16

    16 © 1999 Directed Electr onics , Inc . Vista, CA Door locks are con tr olled by an electrically activated vacuum pump. Som e M er cedes an d A udis use a T ype D system. T est by locking d oors from th e passen ger k ey cylin d er . If all the doors lock, th e vehi cle's door lock system can be contr olled with just two r elays (option al). ...

  • Python 400 ESP - page 17

    © 1999 Directed Electr onics , Inc . Vista, CA 17 tr ansmitter/r eceiv er learn r outine ™ T r ansmitters ar e taugh t to th e system using th e Learn Routin e . This system will learn up to f our tran smitters . Both tran smitters com e factory pr ogr amm ed using Button I f or lock, unlock, an d panic; Button II f or Chann el 2 and Silen t M o ...

  • Python 400 ESP - page 18

    18 © 1999 Directed Electr onics , Inc . Vista, CA Y ou can advance fr om one chann el to an other by r eleasin g th e V alet ® /Pr ogr am switch and tappin g it to advan ce channels an d th en holdin g it. For in stan ce: Y ou have progr ammed Chann el 1 an d you want to pr ogr am Channel 2. Release the V alet ® /Progr am switch. Press it on e t ...

  • Python 400 ESP - page 19

    © 1999 Directed Electr onics , Inc . Vista, CA 19 A rem ote that uses th e OEM Style Configur ati on oper ates similarly to man y f actory keyless en try r emotes . An OEM Style Configur ati on tran smitter allows armin g an d disarming with separ ate button s. Wh en pr ogramm ed f or OEM Style Configur ati on, the tr an smitter button s are assi ...

  • Python 400 ESP - page 20

    20 © 1999 Directed Electr onics , Inc . Vista, CA oper ating settings learn r outine ™ Man y o f the oper atin g settin gs of this unit ar e pr ogramm able . They can be chang ed wh enever n ecessary thr ough a computer-based learn routin e . T o simplify pr ogrammin g, th e DEI Bitwriter (P/N 998T) can be used to chan ge option s as well as loc ...

  • Python 400 ESP - page 21

    © 1999 Directed Electr onics , Inc . Vista, CA 21 Y ou can advance fr om feature to featur e by pr essing an d r eleasin g the V alet ® /Progr am switch th e number o f tim es necessary to g et fr om the featur e you just pr ogr ammed to th e featur e you wish to access. For e x ample , if you just progr amm ed Feature 1 f or passive armin g an d ...

  • Python 400 ESP - page 22

    22 © 1999 Directed Electr onics , Inc . Vista, CA featur e descriptions 1 ACTIVE/P ASSIVE ARMING: When active armin g is selected, th e system will only arm wh en the tr an smitter is used. Wh en set to passive , the system will arm automati cally 30 secon ds after the i gniti on is turn ed off. P assive arming is in di cated by the r api d flashi ...

  • Python 400 ESP - page 23

    © 1999 Directed Electr onics , Inc . Vista, CA 23 Disabling th e Cod e Hoppin g™ featur e lets th e receiver i gn ore th e Cod e Hoppin g™ part o f th e tran smitted wor d. As a r esult, th e unit may have better r an g e with Code H oppin g™ off. r apid r esume logic This DEI system will store its curr en t state to non-volatile m em ory . ...

  • Python 400 ESP - page 24

    24 © 1999 Directed Electr onics , Inc . Vista, CA tr oubleshooting Starter kill does not work: ■ Is th e corr ect starter wire bein g in terrupted? If th e car starts when th e starter kill r elay is completely dis- connected , th e wron g starter wir e has been cut an d interrupted . ■ Is th e yellow wir e connected to “true” i gniti on? ...

Fabricant Python Catégorie Automobile Alarm

Les documents que nous recevons du fabricant de l'appareilPython 400 ESP peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Python
- manuels d’utilisations 400 ESP
- fiches produit Python
- dépliants
- ou étiquettes-énergie Python 400 ESP
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Python 400 ESP.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Python 400 ESP, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Python 400 ESP. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Python 400 ESP.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Python 400 ESP, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Python 400 ESP par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Python 400 ESP.

Le manuel d’utilisation complet Python, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Python 400 ESP - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Python 400 ESP, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lPython 400 ESP qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Python 400 ESP - qui devraient nous aider dans les premières étapes lors de l'utilisation Python 400 ESP
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Python 400 ESP
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Python 400 ESP dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Python 400 ESP?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Python 400 ESP, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Python 400 ESP il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (1)

ефименко виталий

прибор работает 5 мин и отключается подскажите как регулировать таймер?