Manuel d’utilisation Pelican PUV-Basic

24 pages 1.34 mb
Télécharger

Aller à la page of 24

Summary
  • Pelican PUV-Basic - page 1

    • A 5-micron (nominal) sediment filter must be installed upstream of (before) any UV system. • This product is for indoor use only . Keep all components clean and dry . • Clean the sleeve regularly for optimum performance. • Not for use in salt water applications. KE Y INFORMA TION Y OU SHOULD KNO W : Congratulations. By purc hasing this sy ...

  • Pelican PUV-Basic - page 2

    P ot ential Hazar d Saf ety Measur es UV Exposure Never illuminate UV Lamp outside of the UV Chamber . Never look directly at illuminated UV Lamp, even when using protective gear . Always use protective gear , including gloves and UV safety glasses. If accidental exposure occurs, immediately cool affected area and consult ph ysician. Electrical Sho ...

  • Pelican PUV-Basic - page 3

    W ARNING – Alw ays shut-off w ater flow and release water pressure before servicing. T o guard ag ainst injury , basic safety precautions should be observed, including the following: 1. READ AND FOLL O W ALL S AFETY INSTRUCTIONS. 2. D ANGER – T o avoid possible electric shoc k, special care should be taken since water is employed in the use of ...

  • Pelican PUV-Basic - page 4

    INST ALLA TION W ARRANTY MAINTENANCE O VER VIEW T ABLE OF CONTENTS Overview 3 What model do I have? 3 Specifications 4 Components 5 Dimensions and layout 7 Installation 9 Installing the UV system 9 Disinfecting the water lines 1 1 Operation 1 4 Control panel 1 4 T roubleshooting 15 Maintenance 16 Sleeve cleaning and lamp replacement 17 W arranty 20 ...

  • Pelican PUV-Basic - page 5

    INST ALLA TION W ARRANTY MAINTENANCE OPERA TION O VER VIEW WHA T MODEL DO I HA VE? No-tools maintenance Ye s Ye s Ye s Safety cap & special lamp plug Ye s Ye s Ye s Lamp operation indicator Ye s Ye s Ye s Po wer supply operation indicator Ye s Ye s Ye s Reference car d Ye s Ye s Ye s Lamp timer display -- Ye s Ye s Lamp timer reset button -- Ye ...

  • Pelican PUV-Basic - page 6

    INST ALLA TION W ARRANTY MAINTENANCE O VERVIEW SPECIFICA TIONS PUV -Basic PUV -8 PUV -16 Flow Rat es Rated ow for NSF Std 55, Class B 8.9 gpm (33.7 lpm ) 8.9 gpm (33.7 lpm ) 15.8 gpm (59.8 lpm ) Electr ical V oltage 100-240V AC 100-240V AC 100-240V AC Fr equenc y 50-60 Hz 50-60 Hz 50-60 Hz Max. current 0.5 Amp 0.5 Amp 0.85 Amp Max. power consump ...

  • Pelican PUV-Basic - page 7

    INST ALLA TION W ARRANTY MAINTENANCE OPERA TION O VER VIEW 3 2 For replacement components please contact your installer or contact VIQ UA directly for a referral: 1 80 0 265 7246 (Nor th America), 51 9 7 63 1 032, or info@viqua.com. COMPONENTS 4 6 1 Components - PUV -Basic, PUV -8, PUV -16 P ow er supply mounting brac ket All -- Ref erence card All ...

  • Pelican PUV-Basic - page 8

    INST ALLA TION W ARRANTY MAINTENANCE O VERVIEW Lamp (includes O-rings) PUV -Basic, PUV -8 PUV -1 6 602805 602806 O-ring All -- Sleev e bolt All 602665 Sleev e (includes O-rings) PUV -Basic PUV -8 PUV -1 6 602732 602733 UV Chamber (includes Chamber clamp(s), and Ring clamp*). All -- Ring clamp All -- Chamber clamp(s) All -- Solenoid valv e kit (opti ...

  • Pelican PUV-Basic - page 9

    INLET Clearance for lamp removal T o Drain 48” ( 122cm ) OUTLET A B C L D 6 1 2 3 5 4 12 13 11 10 7 14 Ø 16 8 9 L INST ALLA TION W ARRANTY MAINTENANCE OPERA TION O VER VIEW W ARRANTY L Model PUV-Basic 20.5" (52cm) 4" (10cm) 72" (183cm) 8.5" (22cm) 6" (15cm) 54" (137cm) PUV-8 20.5" (52 cm) 4" (10cm) 72" ...

  • Pelican PUV-Basic - page 10

    INST ALLA TION W ARRANTY MAINTENANCE O VER VIEW W ARRANTY MAINTE- NANCE OPERA TION Sample valve: Allows for sampling of raw w ater . Shut-off valve: R equired to allow maintenance of pre-treatment equipment. Pre-treatment (illustrative only): For the UV system to operate ef fecti vely , the water should meet certain water quality parameters, as out ...

  • Pelican PUV-Basic - page 11

    INST ALLA TION O VER VIEW MAINTENANCE OPERA TION Determine appropriate indoor location of the power supply and c hamber , referring to Dimensions and Layout drawing. P ower supply should be installed higher than c hamber away from all w ater sources. Ensure adequate clearance above c hamber to allow for removal of the lamp and sleeve. Insert c hamb ...

  • Pelican PUV-Basic - page 12

    Attac h ground (green/yellow) and strain relief (red) wires from the lamp plug to the ground lug on the c hamber . Secure both wires with loc king screw provided. 12 11 15 Let w ater flow to one faucet or other water outlet, then close the outlet and c hec k for leaks. Proceed to Disinfecting The W ater Lines. Push safety cap into place. Ground lug ...

  • Pelican PUV-Basic - page 13

    INST ALLA TION O VER VIEW MAINTENANCE OPERA TION UV systems disinfect the water using ultraviolet light, treating the w ater as it passes through the system. When there is a risk that water downstream of the UV system has been contaminated, it is critical that these water lines be c hemically disinfected. Disinfection of the water lines is therefor ...

  • Pelican PUV-Basic - page 14

    INST ALLA TION O VERVIEW MAINTENANCE OPERA TION 8 Allow w ater to fill UV c hamber . Let the bleac h sit in the water lines for at least four hours. 11 Go to a water outlet and allow the cold water to flow until you can smell bleac h, then stop the flow. Allow hot water (if present) to flow until you can smell bleac h, then stop the flow. R epeat ...

  • Pelican PUV-Basic - page 15

    INST ALLA TION O VER VIEW MAINTENANCE OPERA TION 19 17 Flush all water outlets until bleac h can no longer be smelled (at least 5 minutes). 18 20 21 16 W ARRANTY 13 ...

  • Pelican PUV-Basic - page 16

    INST ALLA TION O VER VIEW MAINTENANCE OPERA TION Indicat or lights Lamp operating normally W ar ning; lamp will r equire replacement shortly Lamp disconnected; unplug system, reconnect lamp and plug-in system again Lamp failure; replace lamp Lamp inactive due to power supply failure Po wer supply operating normally Air temperature ar ound system is ...

  • Pelican PUV-Basic - page 17

    INST ALLA TION W ARRANTY MAINTENANCE OPERA TION The table below is a list of possible causes and solutions. B efore replacing parts, please contact VIQUA T ec hnical Assist ance f or any ne w troubleshooting tec hniques : 1 -800-265-7246 No power GFCI and/or breaker tripped T ransient voltage surge suppressor (T VSS) damaged Po wer supply damaged R ...

  • Pelican PUV-Basic - page 18

    INST ALLA TION O VER VIEW W ARRANTY MAINTENANCE OPERA TION Sleeve cleaning Minerals in the water slowly form a coating on the sleeve. This coating must be removed because it reduces the amount of UV light reac hing the water , thereby reducing purification performance. Basic models : please clean the sleeve regularly (3-4 times per year , or more o ...

  • Pelican PUV-Basic - page 19

    INST ALLA TION O VER VIEW MAINTENANCE OPERA TION W ARRANTY 4 3 2 6 Let the system cool for 1 0 minutes. 5 1 7 8 Open a tap downstream of the UV unit to release pressure. Then, close this tap. Hold by sleeve bolt to remove lamp/sleeve assembly . Strain relief wires should remain connected. Squeeze tabs 1 2 1 2 9 For sleeve cleaning only: For lamp or ...

  • Pelican PUV-Basic - page 20

    INST ALLA TION O VER VIEW W ARRANTY MAINTENANCE OPERA TION 11 10 13 12 14 Remo ve o-rings and sleeve bolt from sleeve. Reinstall sleeve bolt with 2 new o-rings. Screw lamp into sleeve hand-tight. Caution: Over tightening will break the sleeve. 1 2 1 2 Lamp tab Sleeve bolt 2 1 Make sure lamp/sleeve assembly is centered. Caution: Over tightening will ...

  • Pelican PUV-Basic - page 21

    INST ALLA TION O VER VIEW MAINTENANCE OPERA TION W ARRANTY 18 17 16 Push safety cap into place. 21 22 19 Disinfect the water lines. R efer to Disinfecting the W ater Lines in Installation section. If lamp was replaced and you have a PUV -8 and PUV -16 model: Press and hold Lamp timer reset but ton for 5 seconds. Display should read 365. 20 Chec k f ...

  • Pelican PUV-Basic - page 22

    INST ALLA TION O VERVIEW W ARRANTY MAINTENANCE OPERA TION Our Commitment VIQUA is commit ted to ensuring your experience with our products and organization exceeds your expectations. We have manufactured your UV purification system to the highest quality standards and value you as our customer . Should you need any support, or have questions about ...

  • Pelican PUV-Basic - page 23

    ...

  • Pelican PUV-Basic - page 24

    Printed in Canada. Copyright ©20 14, VIQUA – a T rojan T echnologies Business, Guelph, Ontario, Canada. ...

Fabricant Pelican Catégorie Marine Sanitation System

Les documents que nous recevons du fabricant de l'appareilPelican PUV-Basic peuvent être divisés en plusieurs groupes. Ceux-ci sont, entre autres:
- dessins techniques Pelican
- manuels d’utilisations PUV-Basic
- fiches produit Pelican
- dépliants
- ou étiquettes-énergie Pelican PUV-Basic
Tous sont importants, mais les informations les plus importantes du point de vue de l'utilisation de l'appareil se trouvent dans le manuel d’utilisation Pelican PUV-Basic.

Un groupe de documents appelé manuels d’utilisation est également divisé en types plus spécifiques, tels que: Manuels d’installation Pelican PUV-Basic, manuels d’entretien, brefs manuels ou manuels de l’utilisateur Pelican PUV-Basic. Selon vos besoins, vous devriez chercher le document dont vous avez besoin. Sur notre site, vous pouvez voir le manuel le plus populaire d’utilisation du produit Pelican PUV-Basic.

Manuels d’utilsiation similaires

Manuel d’utilisation complet de l’appareil Pelican PUV-Basic, quelle devrait-elle être?
Le manuel d’utilisation, également appelé le mode d’emploi, ou tout simplement le manuel, est un document technique destiné à aider à utiliser Pelican PUV-Basic par les utilisateurs. Des manuels sont généralement écrits par un rédacteur technique, mais dans un langage accessible à tous les utilisateurs Pelican PUV-Basic.

Le manuel d’utilisation complet Pelican, devrait inclure plusieurs éléments de base. Certains d'entre eux sont moins importants, tels que: la couverture / page de titre ou pages d'auteur. Cependant, la partie restante, devrait nous fournir des informations importantes du point de vue de l'utilisateur.

1. Introduction et des conseils sur la façon d'utiliser le manuel Pelican PUV-Basic - Au début de chaque manuel, nous devrions trouver des indices sur la façon d'utiliser le document. Il doit contenir des informations sur l'emplacement de la table des matières Pelican PUV-Basic, FAQ ou des problèmes les plus fréquents - les points qui sont les plus souvent recherchés par les utilisateurs de chaque manuel
2. Table des matières - index de tous les conseils pour lPelican PUV-Basic qui peuvent être trouvés dans le document courant
3. Conseils sur la façon d'utiliser les fonctions de base de l’appareil Pelican PUV-Basic - qui devraient nous aider dans les premières étapes lors de l'utilisation Pelican PUV-Basic
4. Troubleshooting - séquence systématique des activités qui nous aideront à diagnostiquer et ensuite résoudre les principaux problèmes de Pelican PUV-Basic
5. FAQ - questions fréquemment posées
6. Détails du contact Informations sur l'endroit où chercher le contact avec le fabricant / service Pelican PUV-Basic dans un pays donné, si le problème ne peut être résolu par nous-mêmes.

Avez-vous une question à propos de Pelican PUV-Basic?

Utiliser le formulaire ci-dessous

Si vous n’avez pas résolu votre problème avec Pelican PUV-Basic, avec l'aide du manuel que vous avez trouvé, posez une question en utilisant le formulaire ci-dessous. Si un utilisateur a eu un problème similaire avec Pelican PUV-Basic il est probable qu’il a envie de partager la façon de le résoudre.

Réécrire le texte de l'image

Commentaires (0)